Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

A spin- and angle-resolving photoelectron spectrometer

A new type of hemispherical electron energy analyzer that permits angle and spin resolved photoelectron spectroscopy has been developed. The analyzer permits standard angle resolved spectra to be recorded with a two-dimensional detector in parallel with spin detection using a mini-Mott polarimeter. General design considerations as well as technical solutions are discussed and test results from the Au(111) surface state are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Data Acquisition System For Multichannel Spectrometer On Base Of The NGDP Framework

In present work it is proposed to implement the data acquisition system (DAQ COMBAS) for the fragment--separator COMBAS under freely distributed UNIX--like operating system (OS) FreeBSD on base of the ngdp framework, which allows to build modular distributed DAQ. As a CAMAC subsystem the camac package (DLNP JINR) is used, which encapsulates code deals with each supported crate controller into corresponding driver. Authors create the driver kh(4) for the PCI adapter of the CC02 controller (Karazin Kharkov National University). The runtime configurable r2h(1) histogram server module is supposed. The histGUI(1) client module is intended for histograms viewing as well as for r2h(1) runtime control and configurating. The histGUI(1) client will not depend on DAQ and ngdp system libraries, so can be compiled under any OS equipped by the ROOT package.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relationship between neutron yield rate of tokamak plasmas and spectrometer measured flux for different sight lines

A parametric relationship between total neutron yield rate and collimated fluxes related to the brightness (B) of plasma chords ({lambda}) is developed for different emissivity distributions of tokamak plasmas. Specifically, the brightness was expressed as a function of chord coordinates of radial position using a simple model for the emissivity profiles of width parameter w. The functional brightness dependence B({lambda},w) was calculated to examine the relationship between measured flux and deduced yield rate, and its plasma profile dependence. The results were used to determine the chord range of minimum profile sensitivity in order to identify the preferred collimator sight for the determination of yield rate from neutron emission spectroscopy (YNES) measurements. The YNES method is discussed in comparison to conventional methods to determine the total neutron yield rates and related plasma fusion power relying on uncollimated flux measurements and a different calibration base for the flux-yield relationship. The results have a special bearing for tokamaks operating with both deuterium and deuterium-tritium plasmas and future high power machines such as for ITER, DEMO, and IGNITOR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for DVCS measurements using the COMPASS spectrometer at CERN

The study of exclusive reactions like Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP) is one major part of the future COMPASS program to investigate nucleon structure through Generalized Parton Distributions (GPD). The high energy of the muon beam allows to measure the x{sub Bj}-dependence of the t-slope of the DVCS cross section and to study nucleon tomography. The use of positive and negative polarized muon beams allows to determine the Beam Charge and Spin Difference of the DVCS cross sections to access the real part of the Compton form factor related to the dominant GPD H. As a second phase a transversely polarized proton target will be used to collect data to constrain the GPD E. In preparation of the future measurements two DVCS test runs were performed in 2008 and 2009.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron line shape and transmission function of the KATRIN monitor spectrometer

Knowledge of the neutrino mass is of particular interest in modern neutrino physics. Besides the neutrinoless double beta decay and cosmological observation information about the neutrino mass is obtained from single beta decay by observing the shape of the electron spectrum near the endpoint. The KATRIN β decay experiment aims to push the limit on the effective electron antineutrino mass down to 0.2 eV/c{sup 2}. To reach this sensitivity several systematic effects have to be under control. One of them is the fluctuations of the absolute energy scale, which therefore has to be continuously monitored at very high precision. This paper shortly describes KATRIN, the technique for continuous monitoring of the absolute energy scale and recent improvements in analysis of the monitoring data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A lab-based ambient pressure x-ray photoelectron spectrometer with exchangeable analysis chambers

Ambient pressure X-ray photoelectron spectroscopy (APXPS) is a powerful spectroscopy tool that is inherently surface sensitive, elemental, and chemical specific, with the ability to probe sample surfaces under Torr level pressures. Herein, we describe the design of a new lab-based APXPS system with the ability to swap small volume analysis chambers. Ag 3d(5/2) analyses of a silver foil were carried out at room temperature to determine the optimal sample-to-aperture distance, x-ray photoelectron spectroscopy analysis spot size, relative peak intensities, and peak full width at half maximum of three different electrostatic lens modes: acceleration, transmission, and angular. Ag 3d(5/2) peak areas, differential pumping pressures, and pump performance were assessed under varying N{sub 2}(g) analysis chamber pressures up to 20 Torr. The commissioning of this instrument allows for the investigation of molecular level interfacial processes under ambient vapor conditions in energy and environmental research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact multi-plane broadband (0.5-17 keV) spectrometer using a single acid phthalate crystal

Acid phthalate crystals such as KAP crystals are a method of choice to record x-ray spectra in the soft x-ray regime ( E ~ 1 keV) using the large (001) 2 d = 26.63 Å spacing. Reflection from many other planes is possible, and knowledge of the 2d spacing, reflectivity, and resolution for these reflections is necessary to evaluate whether they hinder or help the measurements. Burkhalter et al. [J. Appl. Phys., 52, 4379 (1981)] showed that the (013) reflection has efficiency comparable to the 2nd order reflection (002), and it can overlap the main first order reflection when the crystal bending axis ( b -axis) is contained in the dispersion plane, thus contaminating the main (001) measurement in a convex crystal geometry. We present a novel spectrograph concept that makes these asymmetric reflections helpful by setting the crystal b -axis perpendicular to the dispersion plane. In such an instance, asymmetric reflections do not overlap with the main (001) reflection and each reflection can be used as an independent spectrograph. In this work we demonstrate an achieved spectral range of 0.8-13 keV with a prototype setup. The detector measurements were reproduced with a 3D ray-tracing code.

47 OTHER INSTRUMENTATION↗

Design and implementation of a J -coupled spectrometer for multidimensional structure and relaxation detection at low magnetic fields

In recent years, it has been realized that low and ultra-low field (mT-nT magnetic field range) nuclear magnetic resonance (NMR) spectroscopy can be used for molecular structural analysis. However, spectra are often hindered by lengthy acquisition times or require large sample volumes and high concentrations. Here, we report a low field (50 µT) instrument that employs a linear actuator to shuttle samples between a 1 T prepolarization field and a solenoid detector in a laboratory setting. The current experimental setup is benchmarked using water and 13 C-methanol with a single scan detection limit of 2x10 20 spins (3 μL, 55 M H 2 O) and detection of 2.9x10 19 (200 μL, 617 mM 13 C-methanol) spins with signal averaging. The system has a dynamic range of >3 orders of magnitude. Investigations of room-temperature relaxation dynamics of 13Cmethanol show that sample dilution can be used in lieu of sample heating to acquire spectra with linewidths comparable to high-temperature spectra. These results indicate that the T 1 and T 2 mechanisms are governed by both the proton exchange rate and the dissolved oxygen in the sample. Finally, a 2D correlation spectroscopy (COSY) experiment is reported, performed in the strong coupling regime that resolves the multiple resonances associated with the heteronuclear Jcoupling. The spectrum was collected using 10 times less sample and in less than half the time from previous reports in the strong coupling limit.

47 OTHER INSTRUMENTATION↗

Interpolating individual line-of-sight neutron spectrometer measurements onto the “sky” at the National Ignition Facility (NIF)

Nuclear diagnostics provide measurements of inertial confinement fusion implosions used as metrics of performance for the shot. The interpretation of these measurements for shots with low mode asymmetries requires a way of combining the data to produce a “sky map” where the individual line-of-sight values are used to interpolate to other positions in the sky. These interpolations can provide information regarding the orientation of the low mode asymmetries. We describe the interpolation method, associated uncertainties, and correlations between different metrics, e.g., Tion, down scatter ratio, and hot-spot velocity direction. This work is also related to recently reported studies [H. G. Rinderknecht et al., Phys. Rev. Lett. 124, 145002 (2020) and K. M. Woo et al., Phys. Plasmas 27, 062702 (2020)] of low mode asymmetries. We report an analysis that makes use of a newly commissioned line of sight, a scheme for incorporating multiple neutron spectrum measurement types, and recent work on the sources of implosion asymmetry to provide a more complete picture of implosion performance.

Hartouni, E. P. (ORCID:0000000198694351)↗

A super-resolution technique to analyze single-crystal inelastic neutron scattering measurements using direct-geometry chopper spectrometers

Direct-geometry time-of-flight chopper neutron spectroscopy is instrumental in studying dynamics in liquid, powder, and single crystal systems. We report here that real-space techniques in optical imagery can be adapted to obtain reciprocal-space super resolution dispersion for phonon or magnetic excitations from single-crystal neutron spectroscopy measurements. The procedure to reconstruct super-resolution energy dispersion of excitations relies on an accurate determination of the momentum and energy-dependent point spread function and a dispersion correction technique inspired by an image disparity calculation technique commonly used in stereo imaging. Here by, applying these methods to spinwave dispersion data from a virtual neutron experiment demonstrates ~5-fold improvement over nominal energy resolution.

47 OTHER INSTRUMENTATION↗