Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Rapid method to determine 89 Sr/ 90 Sr in large concrete samples

Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90 Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g -1 . The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90 Sr from 5-10 g concrete samples. When, the 89 Sr/ 90 Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90 Sr measured, and then 90Sr determined via 90 Y separated after a period of ingrowth. Another approach allows the immediate determination of 90 Sr in 10 g concrete aliquots without waiting for 90 Y ingrowth, in instances where the shorter lived 89 Sr is unlikely to be encountered.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

A Feature-Based Stochastic Permeability of Shale: Part 1—Validation and Two-Phase Permeability in a Utica Shale Sample

Estimate of permeability plays a crucial role in flow-based studies of fractured tight-rocks. It is well known that most of the flow through tight-rocks (e.g., shales) is controlled by permeable features (e.g., fractures, laminations, etc.), and there is negligible flow through the matrix. However, current approaches in the literature to model permeability of tight-rocks do not account for such features present within the rock ranging from micro-scale to field-scale. Current permeability modeling approach assumes a single continuum without considering the presence of permeable features within the matrix (e.g., micro-fractures) or outside the matrix (e.g., natural fractures). Although the laboratory-measured permeability implicitly captures discrete features present in that sample (e.g., fractures, laminations, micro-fractures), most of the permeability models proposed for shale do not account for these features. Fracture permeability in the literature is typically modeled using an ideal slit assumption; however, this highly overestimates its permeability because fractures in real medium are non-ideal in terms of their porosity and tortuosity, which affect their permeability. Additionally, the transition zone between fracture and matrix also affects the permeability of fracture. Here in this study, part of a two-part series, a new method to predict permeability of fractured shale by discretizing the medium into matrix (inorganic and organic) and fractures is presented. New analytical expressions of permeability are derived to account for non-ideal nature of porous medium and two-phase flow in fractures. Rock feature in each cell of the grid is identified as one of the three elements (organic matter, inorganic matter, or fracture), and permeability of that cell is estimated using a suitable analytical expression. This method allows estimating permeability at any scale of interest and more robustly than by a pure analytical approach. The proposed method is validated against local and global-scale measurements on three fractured samples from laboratory. Finally, the method is used to predict two-phase flow permeability of supercritical CO 2 displacing water within a fracture in a Utica shale sample. The proposed two-phase flow permeability equations can be used as a quick analytical tool to predict relative permeability estimates of two-phase flow in fractured shale samples. In Part 2, the proposed method is used to estimate field-scale permeability through an optimization process that uses field-scale production and other readily available information.

58 GEOSCIENCES↗

Effects of Coatings on the High-Cycle Fatigue Life of Threaded Steel Samples

In this work, high-cycle fatigue is studied for threaded cylindrical high-strength steel samples coated using three different industrial processes: black oxidation, normal-temperature galvanization and high-temperature galvanization. The fatigue performance in air is compared with that of uncoated samples. Microstructural characterization revealed the abundant presence of small cracks in the zinc coating partially penetrating into the steel. This is consistent with the observation of multiple crack initiation sites along the thread in the galvanized samples, which led to crescent type fracture surfaces governed by circumferential growth. In contrast, the black oxidized and uncoated samples exhibited a semicircular segment type fracture surface governed by single-sided growth with a significantly longer fatigue life. Numerical fatigue life prediction based on an extended Paris-law formulation has been conducted on two different fracture cases: 2D axisymmetric multisided crack growth and 3D single-sided crack growth. The results of this upper-bound and lower-bound approach are in good agreement with experimental data and can potentially be used to predict the lifetime of bolted components.

36 MATERIALS SCIENCE↗

Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source

A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O – 3H]{sup +} was observed in the case of individual alkanes (C{sub 5}–C{sub 19}) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Fibrinogen-Specific Sandwich Enzyme-Linked Immunosorbent Assay Microarray Assay for Distinguishing Between Blood Plasma and Serum Samples

We have developed a fibrinogen-specific sandwich ELISA microarray assay for use in qualitatively distinguishing between blood plasma and serum samples. Three capture antibodies, 49D2, HPA001900, and F8512, were evaluated in conjunction with 1D6 as detection antibody, and the data show that 49D2 and, to a lesser extent, F8512 successfully identify previously unknown plasma and serum samples based upon a ~28-fold difference in signal intensity between the sample types. This assay has utility in rapidly identifying previously archived clinical samples with incomplete annotation in a high throughput manner prior to proteomics analyses.

60 APPLIED LIFE SCIENCES↗

Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM

We introduced a novel X-ray microscope system based on scanning electron microscopy using thin film, which enables the measurement of unstained biological samples without damage. An unstained yeast sample was adsorbed under a titanium (Ti)-coated silicon nitride (Si{sub 3}N{sub 4}) film 90 nm thick. The X-ray signal from the film was detected by an X-ray photodiode (PD) placed below the sample. With an electron beam at 2.6 kV acceleration and 6.75 nA current, the yeast image is obtained using the X-ray PD. The image is created by soft X-rays from the Ti layer. The Ti layer is effective in generating the characteristic 2.7-nm wavelength X-rays by the irradiation of electrons. Furthermore, we investigated the electron trajectory and the generation of the characteristic X-rays within the Ti-coated Si{sub 3}N{sub 4} film by Monte Carlo simulation. Our system can be easily utilized to observe various unstained biological samples of cells, bacteria, and viruses.

60 APPLIED LIFE SCIENCES↗

Sample-based synthesis of two-scale structures with anisotropy

A vast majority of natural or synthetic materials are characterized by their anisotropic properties, such as stiffness. Such anisotropy is effected by the spatial distribution of the fine-scale structure and/or anisotropy of the constituent phases at a finer scale. In design, proper control of the anisotropy may greatly enhance the efficiency and performance of synthesized structures. In this paper, we propose a sample-based two-scale structure synthesis approach that explicitly controls anisotropic effective material properties of the structure on the coarse scale by orienting sampled material neighborhoods at the fine scale. We first characterize the non-uniform orientations distribution of the sample structure by showing that the principal axes of an orthotropic material may be determined by the eigenvalue decomposition of its effective stiffness tensor. Such effective stiffness tensors can be efficiently estimated based on the two-point correlation functions of the fine-scale structures. Then we synthesize the two-scale structure by rotating fine-scale structures from the sample to follow a given target orientation field. Finally, the effectiveness of the proposed approach is demonstrated through examples in both 2D and 3D.

42 ENGINEERING↗

Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites was studied. Major organs (brain, lung, liver, kidney, muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. Furthermore, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.

59 BASIC BIOLOGICAL SCIENCES↗

2D-imaging of sampling-probe perturbations in laminar premixed flames using Kr X-ray fluorescence

The perturbation of the temperature field caused by a quartz sampling probe has been investigated in a fuel-rich low-pressure premixed ethylene/oxygen/argon/krypton flame using X-ray fluorescence. The experiments were performed at the 7-BM beamline at the Advanced Photon Source (APS) at the Argonne National Laboratory where a continuous beam of X-rays at 15 keV was used to excite krypton atoms that were added to the unburnt flame gases in a concentration of 5% (by volume). The resulting krypton X-ray fluorescence at 12.65 keV was collected and the spatially resolved signal was subsequently converted into the local temperature of the imaged spot. One and two dimensional scans of the temperature field were obtained by translating the entire flame chamber through a pre-programmed sequence of positions on high precision translation stages and measuring the X-ray fluorescence at each location. Multiple measurements were performed at various separations between the burner surface and probe tip, representing sampling positions from the preheat, reaction, and postflame zones of the low-pressure flame. Distortions of up to 1000 K of the burner-probe centerline flame temperature were found with the tip of the probe in the preheat zone and distortions of up to 500 K were observed with it in the reaction and postflame zones. Furthermore, perturbations of the temperature field have been revealed that radially reach as far as 20 mm from the burner-probe centerline and about 3 mm in front of the probe tip. Finally, these results clearly reveal the limitations of one-dimensional models for predicting flame-sampling experiments and comments are made with regard to model developments and validations based on quantitative speciation data from low-pressure flames obtained via intrusive sampling techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Serum levels of perfluoroalkyl compounds in human maternal and umbilical cord blood samples

Perfluoroalkyl compounds (PFCs) are end-stage metabolic products from industrial flourochemicals used in the manufacture of plastics, textiles, and electronics that are widely distributed in the environment. The objective of the present study was to quantify exposure to perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), perfluorodecanoic acid (PFDeA), perfluorohexane sulfonate (PFHxS), perfluoroheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA) in serum samples collected from pregnant women and the umbilical cord at delivery. Pregnant women (n=101) presenting for second trimester ultrasound were recruited and PFC residue levels were quantified in maternal serum at 24-28 weeks of pregnancy, at delivery, and in umbilical cord blood (UCB; n=105) by liquid chromatography-mass spectrometry. Paired t-test and multiple regression analysis were performed to determine the relationship between the concentrations of each analyte at different sample collection time points. PFOA and PFOS were detectable in all serum samples analyzed including the UCB. PFOS serum levels (mean{+-}S.D.) were significantly higher (p<0.001) in second trimester maternal serum (18.1{+-}10.9 ng/mL) than maternal serum levels at delivery (16.2{+-}10.4 ng/mL), which were higher than the levels found in UCB (7.3{+-}5.8 ng/mL; p<0.001). PFHxS was quantifiable in 46/101 (45.5%) maternal and 21/105 (20%) UCB samples with a mean concentration of 4.05{+-}12.3 and 5.05{+-}12.9 ng/mL, respectively. There was no association between serum PFCs at any time point studied and birth weight. Taken together our data demonstrate that although there is widespread exposure to PFCs during development, these exposures do not affect birth weight.

60 APPLIED LIFE SCIENCES↗

Effect of sample size on the maximum value distribution of fatigue driving forces in metals and alloys

An analytical framework is presented to predict the effects of sample size on the maximum value distribution (MVD) of the driving forces for fatigue crack formation in metals and alloys. The distribution of the maximum driving force for fatigue crack formation over the domain follows the generalized extreme value theory in the limit as the domain size increases to infinity. Here, a simulation-based analysis of microstructure influences on fatigue resistance for polycrystalline metals and alloys is very costly, and reaching those limits is intractable. This work models the MVD of Fatigue Indicator Parameters (FIPs), which serve as surrogate measures for the driving force for fatigue crack formation, at finite sample sizes prior to their convergence to a limiting extreme value distribution. Large-scale crystal plasticity finite element (CPFE) simulations of FCC Al 7075-T6 with microstructure realizations of various sizes are incorporated to calibrate and evaluate the developed framework, and a total of ∼6.5 million grains of Al 7075-T6 are examined. The calibrated analytical solution agrees well with the brute force Monte Carlo simulation results extracted from the CPFE simulations. Furthermore, the developed formulation can predict the MVD of FIPs for different sample sizes using a size-dependent parameter, and it is capable of accurately extrapolating the MVD of FIPs for much larger microstructure sample sizes than the size used for its calibration.

Crystal plasticity↗

Measured CO 2 sorption isotherms with 25 Bakken Petroleum System rock samples from the Lower and Upper Shales, Middle Bakken, and Three Forks formations

Isotherms were measured with 25 Bakken Petroleum System (BPS) rock samples using a magnetic suspension balance at reservoir conditions of 110 °C and pressures up to 345 bar. Samples from four wells represented the Middle Bakken (MB) and Three Forks (TF) production zones, and the Upper Bakken Shale (UBS) and Lower Bakken Shale (LBS) source shales. UBS and LBS CO 2 sorption capacities at 345 bar averaged 12–14 g/kg rock compared to 1.3 to 2.5 g/kg rock for MB and TF. Increasing pressure from 150 to 345 bar resulted in only small increases in CO 2 sorption for all lithofacies. For the UBS and LBS source shales, the higher average total organic carbon (TOC) values (14.7 and 11.4 wt.%) and clay values (25 and 28 wt.%) corresponded to their higher CO 2 sorption values while for the MB and TF samples, lower TOCs (0.3 and 0.5 wt.%) and clay values (8.2 and 18.2 wt.%) corresponded to lower CO 2 sorption values. Here, when all 25 samples (from all lithofacies) were evaluated as a group, sorption capacities were highly correlated with TOC (Spearman's rho values +0.84 to +0.85), with rock density (rho values -0.75 to -0.76), and clay content (rho values +0.66). However, correlations with porosity and thermal maturity (Tmax) were weak. Measured sorption capacities and rock porosities showed that sorption accounted for about 10-times as much CO 2 storage as the available pore space for the UBS and LBS lithofacies. In contrast, the pore space dominated the storage resource of the TF and MB lithofacies.

54 ENVIRONMENTAL SCIENCES↗

On the Importance of Accounting for Competing Risks in Pediatric Brain Cancer: II. Regression Modeling and Sample Size

Purpose: To accurately model the cumulative need for radiotherapy in trials designed to delay or avoid irradiation among children with malignant brain tumor, it is crucial to account for competing events and evaluate how each contributes to the timing of irradiation. An appropriate choice of statistical model is also important for adequate determination of sample size. Methods and Materials: We describe the statistical modeling of competing events (A, radiotherapy after progression; B, no radiotherapy after progression; and C, elective radiotherapy) using proportional cause-specific and subdistribution hazard functions. The procedures of sample size estimation based on each method are outlined. These are illustrated by use of data comparing children with ependymoma and other malignant brain tumors. The results from these two approaches are compared. Results: The cause-specific hazard analysis showed a reduction in hazards among infants with ependymoma for all event types, including Event A (adjusted cause-specific hazard ratio, 0.76; 95% confidence interval, 0.45-1.28). Conversely, the subdistribution hazard analysis suggested an increase in hazard for Event A (adjusted subdistribution hazard ratio, 1.35; 95% confidence interval, 0.80-2.30), but the reduction in hazards for Events B and C remained. Analysis based on subdistribution hazard requires a larger sample size than the cause-specific hazard approach. Conclusions: Notable differences in effect estimates and anticipated sample size were observed between methods when the main event showed a beneficial effect whereas the competing events showed an adverse effect on the cumulative incidence. The subdistribution hazard is the most appropriate for modeling treatment when its effects on both the main and competing events are of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual experiments: Combining realistic neutron scattering instrument and sample simulations

A new sample component is presented for the Monte Carlo, ray-tracing program, McStas, which is widely used to simulate neutron scattering instruments. The new component allows the sample to be described by its material dynamic structure factor, which is separated into coherent and incoherent contributions. The effects of absorption and multiple scattering are treated and results from simulations and previous experiments are compared. The sample component can also be used to treat any scattering material which may be close to the sample and therefore contaminates the total, measured signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aerosol Sample Inhomogeneity with Debris from the Fukushima Daiichi Nuclear Accident

Radionuclide aerosol sampling is a vital component in the detection of nuclear explosions, nuclear accidents, and other radiation releases. This was proven by the detection and tracking of emissions from the Fukushima Daiichi incident across the globe by IMS stations. Two separate aerosol samplers were operated in Richland, WA following the event and debris from the accident were measured at levels well above detection limits. While the atmospheric activity concentration of radionuclides generally compared well between the two stations, they did not agree within uncertainties. This paper includes a detailed study of the aerosol sample homogeneity of 134 Cs and 137 Cs, then relates it to the overall uncertainty of the original measurement. Our results show that sample inhomogeneity adds an additional 5–10% uncertainty to each aerosol measurement and that this uncertainty is in the same range as the discrepancies between the two aerosol sample measurements from Richland, WA.

Gomez, Reynaido↗

Thermoelectric properties and impedance spectroscopy of polycrystalline samples of the beta-gallia rutile intergrowth, (Ga,In){sub 4}(Sn,Ti){sub 5}O{sub 16}

Polycrystalline samples of Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.3 were prepared by solid-state synthesis and characterized to determine their optical properties, thermoelectric properties and electrical impedance. Using diffuse reflectance data and assuming a direct band gap, the band gap of the material ranges from 3.58 eV for y=0 to 3.74 eV for y=0.2. The dc conductivity decreased with increasing Ti content and was thermally activated, ranging from {<=}10{sup -5} S/cm at 300 Degree-Sign C to 0.03 S/cm at 1000 Degree-Sign C for Ga{sub 3}InSn{sub 5}O{sub 16}. The Seebeck coefficient was negative indicating n-type conduction. The activation energies for dc conduction and thermopower were similar, ranging from 1.4{+-}0.1 eV for y=0 to 1.8{+-}0.2 eV for y=0.2, suggesting band conduction. The thermal conductivity of Ga{sub 3}InSn{sub 5}O{sub 16} ranged from 1.1 W/m K at 500 {sup o}C to 0.75 W/m K at 800 Degree-Sign C. The highest figure of merit measured was 2 Multiplication-Sign 10{sup -4} at {approx}900 Degree-Sign C, which is much lower than desired for thermoelectric materials. A comparison of dc conductivity and impedance data indicated a substantial ionic contribution for samples containing titanium. - Graphical abstract: The thermoelectric properties of polycrystalline Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.3 were measured in air at 300-900 Degree-Sign C. The materials are broad-band n-type semiconductors with non-negligible ionic conduction for samples prepared with y>0. The thermoelectric figure of merit is much lower than desired for practical thermoelectric devices. Highlights: Black-Right-Pointing-Pointer Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.2 is a broad-band n-type semiconductor. Black-Right-Pointing-Pointer The conductivity of Ti-containing samples show evidence of an ionic as well as an electronic contribution. Black-Right-Pointing-Pointer The thermal conductivity of polycrystalline Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16} decreases with increasing temperature. Black-Right-Pointing-Pointer The thermoelectric figure of merit for Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16} is lower than desired for practical thermoelectric devices.

36 MATERIALS SCIENCE↗

Doping effect on the structural properties of Cu{sub 1−x}(Ni, Zn, Al and Fe){sub x}O samples (0<x<0.10): An experimental and computational study

In this work, the effect of insertion of transition metal, TM (=Ni, Zn, Al and Fe), ions in Cu{sub 1−x}TM{sub x}O samples (0<x<0.10) prepared via co-precipitation method is studied through experimental and computational methods. The analyses of X-ray diffraction (XRD) patterns using Rietveld refinement show that i) at x=0, all samples present a monoclinic crystal system with space group C2/c and ii) for increasing the TM-doping, Ni and Zn-doped samples show a small amount of spurious phases for concentrations above x=0.05. Based on these results, a defect disorder study for using atomistic computational simulations which is based on the lattice energy minimization technique is employed to predict the location of the dopant ions in the structure. In agreement with XRD data, our computational results indicate that the trivalent (Al and Fe ions) are more favorable to be incorporated into CuO matrix than the divalent (Ni and Zn ions). - Graphical Abstract: The effect of insertion of transition metal, TM (=Ni, Zn, Al and Fe), ions in Cu{sub 1−x}TM{sub x}O samples (0<x<0.10) prepared via co-precipitation method is studied through experimental and computational methods. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗