Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Effects of surface initial condition on aqueous corrosion of glass-A study with a model nuclear waste glass

Being a nonequilibrium material, the structure of glass varies with the sample history. Thus, the initial surface condition of a glass can vary with the preparation condition and have a large impact on its reactivity. This paper shows that the aqueous corrosion behavior of international simple glass (ISG) varies depending on the initial surface state. The ISG glass samples were prepared as-polished-only and polished-then-annealed and they were immersed in aqueous solution saturated with soluble SiO 2 at 30°C (modeling a mild condition) and at 90°C (modeling a severe condition). Molecular dynamics simulations were performed to obtain coordination numbers of network formers of ISG to assist oxygen speciation calculations. The surface structures of as-prepared and corroded ISG samples were analyzed using various imaging and spectroscopic techniques. Among these analyses, only the oxygen speciation with x-ray photoelectron spectroscopy showed discernable differences between two uncorroded surfaces with different preparation histories; all other methods could not differentiate the surface preparation history before aqueous corrosion. Such minor difference in chemical structures was found to have a profound impact on corrosion behaviors in the mild condition. In the harsh condition, the surface history dependence was not as drastic as the corrosion in the mild condition. The analysis results of the corroded surfaces suggested that the thickness and structure of the alteration layer formed on ISG in aqueous corrosion can vary with the initial surface state.

nuclear, defects, corrosion↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

Phase diagram features and solidification behaviour of CoCu{sub 2}O{sub 3} at elevated oxygen pressure

A unique behaviour of the phase CoCu{sub 2}O{sub 3} was found both from CALPHAD calculations and directional solidification experiments. For elevated oxygen partial pressure the solidification mode changed from double-peritectic to a congruent melting behaviour with respect to the metals (Cu, Co) and to the oxygen content. This transition predicted by the phase diagram calculations was confirmed by microstructure and phase analyses of samples solidified at oxygen pressures up to 60 bar. A DTA analysis has verified basic features of the phase diagram at normal pressures. - Graphical abstract: A unique behaviour of the phase CoCu{sub 2}O{sub 3} was found both from CALPHAD calculations and directional solidification experiments. For elevated oxygen partial pressure the solidification mode changed from double-peritectic (1 bar O{sub 2}; left figure) to a congruent melting behaviour with respect to the metals (Cu, Co) and to the oxygen content (80 bar O{sub 2}; right figure).

36 MATERIALS SCIENCE↗

Dosimetric measurements of an n-butyl cyanoacrylate embolization material for arteriovenous malformations

Purpose: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. Methods: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derived from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner’s HU calibration curve. Results: The ELAC was 0.0516 ± 0.0063 cm{sup −1} and 0.0580 ± 0.0091 cm{sup −1} for n-BCA without and with tantalum, respectively, compared to 0.0487 ± 0.0009 cm{sup −1} for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of −0.29% and −0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum, respectively; dosimetrically appropriate HU values were estimated to be 79 and 199 HU, respectively. Conclusions: The dosimetric properties of the embolization agents are very close to those of water for a 6 MV beam. Therefore, treating the entire intracranial space as uniform in composition will result in less than 1% dosimetric error for n-BCA emboli smaller than 3.4 cm without added tantalum and n-BCA emboli smaller than 1.1 cm with added tantalum. Furthermore, when effective embolization can be achieved by the neurointerventionalist using n-BCA without tantalum, the dosimetric impact of overriding material properties will be lessened. However, due to the high attenuation of embolization agents with and without added tantalum for diagnostic energies, artifacts may occur that necessitate additional imaging to accurately identify the spatial extent of the region to be treated.

07 ISOTOPE AND RADIATION SOURCES↗

A sensitivity analysis to predict the neutronics behavior of samples irradiated in the VTR rabbit system

We report a low-order neutronics model is developed to carry out hundreds of simulations efficiently and investigate the neutronics behavior of samples being irradiated in a test reactor setting under different geometrical constraints. The low-order model allowed for simulations that yield the expected neutronics behavior of any irradiated sample in any environment and allows for the calculation of highly accurate spatially averaged statistics and idealized spatial distributions in the neutron flux. Several benchmarks are performed to evaluate the performance and limitations of the low-order model revealing many important findings. The low-order model predicted the LHGR in the EBR-II driver fuel to within 2.34% by only simulating the fuel rod by itself, which served as a validation for the model. Sensitivity studies investigated 3% enriched UO 2 and U-10Zr being irradiated in the Versatile Test Reactor rabbit system. The analyses investigated a range of combinations of 15 radii and 5 heights for each sample in the rabbit system. Similar data sets are also provided for irradiations in the Advanced Test Reactor’s B-10 irradiation position, which is a thermal neutron spectrum environment. Generalized fits and fit coefficients are obtained for sample heating, reaction rate densities, and local multiplication rate characteristics, allowing the predictions of the neutronics behavior of the samples based on their geometrical constraints. The analyses and fits laid the groundwork for developing a user-end Multiphysics analysis framework to assist and accelerate irradiation experiment design and optimization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identification of boron clusters in silicon crystal by B1s core-level X-ray photoelectron spectroscopy: A first-principles study

We carried out a comprehensive study on the B1s core-level X-ray photoelectron spectroscopy (XPS) binding energies for B clusters in crystalline Si using a first-principles calculation with careful evaluation of the local potential boundary condition for the model system, where convergence within 0.1 eV was confirmed for the supercell size. For ion-implanted samples, we identified experimental peaks due to B clusters and threefold B as icosahedral B{sub 12} and <001>B-Si defects, respectively. For as-doped samples prepared by plasma doping, it was found that the calculated XPS binding energies for complexes of vacancies and B atoms were consistent with the experimental spectra.

36 MATERIALS SCIENCE↗

Electronic Structure and Optical Properties of Cu 2 ZnGeSe 4 . First-Principles Calculations and Vacuum-Ultraviolet Spectroscopic Ellipsometric Studies

Cu 2 ZnGeSe 4 is of interest for the development of next-generation thin-film photovoltaic technologies. To understand its electronic structure and related fundamental optical properties, we perform first-principles calculations for three structural variations: kesterite, stannite, and primitive-mixed CuAu phases. The calculated data are compared with the room-temperature dielectric functionϵ=ϵ1+iϵ2 spectrum of polycrystalline Cu 2 ZnGeSe 4 determined by vacuum-ultraviolet spectroscopic ellipsometry in the photon-energy range of 0.7 to 9.0 eV. Ellipsometric data are modeled with the sum of eight Tauc-Lorentz oscillators, and the best-fit model yields the band-gap and Tauc-gap energies of 1.25 and 1.19 eV, respectively. A comparison of overall peak shapes and relative intensities between experimental spectra and the calculated ϵ data for three structural variations suggests that the sample may not have a pure (ordered) kesterite phase. We found that the complex refractive index N=n+ik, normal-incidence reflectivity R, and absorption coefficients α are calculated from the modeled ϵ spectrum, which are also compared with those of Cu 2 ZnSnSe 4 . The spectral features for Cu 2 ZnGeSe 4 appear to be weaker and broader than those for Cu 2 ZnSnSe 4 , which is possibly due to more structural imperfections presented in Cu 2 ZnGeSe 4 than Cu 2 ZnSnSe 4 .

14 SOLAR ENERGY↗

High-temperature oxidation kinetics of sponge-based E110 cladding alloy

Two-sided oxidation experiments were recently conducted at 900°C–1200 °C in flowing steam with samples of sponge-based Zr-1Nb alloy E110. Although the old electrolytic E110 tubing exhibited a high degree of susceptibility to nodular corrosion and experienced breakaway oxidation rates in a relatively short time, the new sponge-based E110 demonstrated steam oxidation behavior comparable to Zircaloy-4. Sample weight gain and oxide layer thickness measurements were performed on oxidized E110 specimens and compared to oxygen pickup and oxide layer thickness calculations using the Cathcart-Pawel correlation. Our study shows that the sponge-based E110 follows the parabolic law at temperatures above 1015 °C. At or below 1015 °C, the oxidation rate was very low when compared to Zircaloy-4 and can be represented by a cubic expression. No breakaway oxidation was observed at 1000 °C for oxidation times up to 10,000 s. Arrhenius expressions are given to describe the parabolic rate constants at temperatures above 1015 °C and cubic rate constants are provided for temperatures below 1015 °C. The weight gains calculated by our equations are in excellent agreement with the measured sample weight gains at all test temperatures. In addition to the as-fabricated E110 cladding sample, prehydrided E110 cladding with hydrogen concentrations in the 100–150 wppm range was also investigated. The effect of hydrogen content on sponge-based E110 oxidation kinetics was minimal. No significant difference was found between as-fabricated and hydrided samples with regard to oxygen pickup and oxide layer thickness for hydrogen contents below 150 wppm.

36 MATERIALS SCIENCE↗

MOCMC: Method of Characteristics Moment Closure, a Numerical Method for Covariant Radiation Magnetohydrodynamics

In this work, we present a conservative numerical method for radiation magnetohydrodynamics with frequency-dependent full transport in stationary spacetimes. This method is stable and accurate for both large and small optical depths and radiation pressures. The radiation stress–energy tensor is evolved in flux-conservative form, and closed with a swarm of samples that each transport a multigroup representation of the invariant specific intensity along a null geodesic. In each zone, the enclosed samples are used to efficiently construct a Delaunay triangulation of the unit sphere in the comoving frame, which in turn is used to calculate the Eddington tensor, average source terms, and adaptively refine the sample swarm. Furthermore, radiation four-forces are evaluated in the moment sector in a semi-implicit fashion. The radiative transfer equation is solved in invariant form deterministically for each sample. Since each sample carries a discrete representation of the full spectrum, the cost of evaluating the transport operator is independent of the number of frequency groups, representing a significant reduction of algorithmic complexity for transport in frequency-dependent problems. The major approximation we make in this work is performing scattering in an angle-averaged way. Local adaptivity in samples also makes this scheme more amenable to nonuniform meshes than a traditional Monte Carlo method. We describe the method and present results on a suite of test problems. We find that Method of Characteristics Moment Closure converges at least as ~N -1 , rather than the canonical Monte Carlo N -1/2 , where N is the number of samples per zone.

79 ASTRONOMY AND ASTROPHYSICS↗

Ar-40/Ar-39 Ages of Maskelynite Grains from ALHA 77005

We present Ar-40/Ar-39 measurements for twelve small (20-60 micro-g) maskelynite samples from the heavily shocked martian meteorite ALHA 77005. The reported modal composition for ALHA 77005 is 50-60% olivine (Fa28), 30-40% pyroxene (Wo5Fs23En72), approx.8% maskelynite (An53), and approx.2% opaques by volume [1]). The meteorite is usually classified as a lherzolite. Previous Studies - Ar-40/Ar-39 results from previous work display disturbed release spectra [2,3]. In study [2], Ar-40/Ar-39 measurements on a 52-mg whole-rock sample produced an extremely disturbed release spec-trum, with all calculated apparent ages > 1 Ga, (Fig. 1). In a subsequent study [3], a light and a dark phase were analyzed. A 2.3-mg sample of the light, relatively low-K phase produced a disturbed release spectrum. For the first 20% of the Ar-39(sub K), most of the apparent ages exceeded >1 Ga; the remaining 80% yielded ages between 0.3-0.5 Ga. The integrated age for this phase is 0.9 Ga.

Turrin, B.↗

SLICING AND DICING THE MILKY WAY DISK IN THE SLOAN DIGITAL SKY SURVEY

We use the Stripe 82 proper-motion catalog of Bramich et al. to study the kinematics of Galactic disk stars in the solar neighborhood. We select samples of dwarf stars with reliable spectra and proper motions. They have cylindrical polar radii between 7 {<=} R {<=} 9 kpc, heights from the Galactic plane satisfying |z| {<=} 2 kpc, and span a range of metallicities -1.5 {<=} [Fe/H] {<=} 0. We develop a method for calculating and correcting for the halo contamination in our sample using the distribution of rotational velocities. Two Gaussians representing disk and halo populations are used to fit the radial (v{sub R} ) and vertical (v{sub z} ) velocity distributions via maximum likelihood methods. For the azimuthal velocities (v{sub {phi}}) the same technique is used, except that a skewed non-Gaussian functional form now represents the disk velocity distribution. This enables us to compute the dispersions {sigma}{sub R}, {sigma}{sub z}, {sigma}{sub {phi}}, and cross-terms (the tilt {sigma}{sub Rz} and the vertex deviation {sigma}{sub R{phi}}) of the velocity ellipsoid as a function of height and metallicity. We also investigate the rotation lag of the disk, finding that the more metal-poor stars rotate significantly slower than the metal-rich stars. These samples provide important constraints on heating mechanisms in the Galactic disk and can be used for a variety of applications. We present one such application employing the Jeans equations to provide a simple model of the potential close to the disk. Our model is in excellent agreement with others in the literature and provides an indication that the disk, rather than the halo, dominates the circular speed at the solar neighborhood. We obtain a surface mass density within 1.1 kpc of around 66 M{sub Sun} pc{sup -2} and estimate a local halo density of 0.015 M{sub Sun} pc{sup -3} = 0.57 GeV cm{sup -3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Transport Properties of Polyethylene-Fiber Composites

Composite materials that can both serve as effective shielding materials against cosmic-ray and energetic solar particles in deep space as well as structural materials for habitat and spacecraft remain a critical and mission enabling piece in mission planning and exploration. Polyethylene is known to have excellent shielding properties due to its low density coupled with high hydrogen content. Polyethylene fiber reinforced composites promise to combine this shielding effectiveness with the required mechanical properties of structural materials. Samples of Polyethylene-fiber reinforced epoxy matrix composite 1-5 cm thick were prepared at NASA's Marshall Space Flight Center and tested against 500 MeV/nucleon Fe beam at the HIMAC facility of NIRS in Chiba, Japan. This paper presents measured and calculated results for the radiation transport properties of these samples.

Kaul, Raj K.↗

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Comparison of RESRAD-Derived External Dose to TLD Dose - 18522

At the Nevada National Security Site, external dose at corrective action sites is generally estimated using environmental thermoluminescent dosimeters (TLDs). These devices integrate the penetrating radiation dose at the location being evaluated. Because these devices will also integrate the external dose from natural sources of penetrating radiation (e.g., cosmic rays and naturally occurring radionuclides in soil), the natural background external dose level as measured by TLDs placed in similar but unaffected areas is subtracted from the gross TLD reading. The use of TLDs to estimate the external dose component of the total effective dose was determined to be the most effective method because the TLDs are exposed for an extended time period and TLDs are compliant with Title 10 Code of Federal Regulations Part 835.402, 'Individual Monitoring,' to monitor individual exposures. At sample locations where no TLD results are available (such as subsurface locations), estimated external dose is calculated from a RESRAD-derived external dose using radionuclide activities measured from soil samples. A comparison of estimated external doses from locations where both TLD data and soil sample data are available is presented herein. This comparison demonstrates that estimated external dose using RESRAD and soil sample radionuclide activities generally results in a significantly lower external dose than by using TLD results. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surfactant assisted growth of MgO films on GaN

Thin epitaxial films of <111> oriented MgO on [0001]-oriented GaN were grown by molecular beam epitaxy and pulsed laser deposition using the assistance of a vapor phase surfactant. In both cases, surfactant incorporation enabled layer-by-layer growth and a smooth terminal surface by stabilizing the {l_brace}111{r_brace} rocksalt facet. Metal-insulator-semiconductor capacitor structures were fabricated on n-type GaN. A comparison of leakage current density for conventional and surfactant-assisted growth reveals a nearly 100 Multiplication-Sign reduction in leakage current density for the surfactant-assisted samples. These data verify numerous predictions regarding the role of H-termination in regulating the habit of rocksalt crystals.

36 MATERIALS SCIENCE↗

Space radiation transport properties of polyethylene-based composites

Composite materials that can serve as both effective shielding materials against cosmic-ray and energetic solar particles in deep space, as well as structural materials for habitat and spacecraft, remain a critical and mission enabling component in mission planning and exploration. Polyethylene is known to have excellent shielding properties due to its low density, coupled with high hydrogen content. Polyethylene-fiber reinforced composites promise to combine this shielding effectiveness with the required mechanical properties of structural materials. Samples of polyethylene-fiber reinforced epoxy matrix composite 1-5 cm thick were prepared at the NASA Marshall Space Flight Center and tested against a 500 MeV/nucleon Fe beam at the HIMAC facility of NIRS in Chiba, Japan. This paper presents measured and calculated results for the radiation transport properties of these samples.

Polyethylene/chemistry↗

Effective detection of CO 2 leakage: a comparison of groundwater sampling and pressure monitoring

Shallow aquifer monitoring is likely to be a required aspect to any geologic CO 2 sequestration operation. Collecting groundwater samples and analyzing for geochemical parameters such as pH, alkalinity, total dissolved carbon, and trace metals has been suggested by a number of authors as a possible strategy to detect CO 2 leakage. The effectiveness of this approach, however, will depend on the hydrodynamics of the leak-induced CO 2 plume and the spatial distribution of the monitoring wells relative to the origin of the leak. To our knowledge, the expected effectiveness of groundwater sampling to detect CO 2 leakage has not yet been quantitatively assessed. In this study we query hundreds of simulations developed for the National Risk Assessment Project (US DOE) to estimate risks to drinking water resources associated with CO 2 leaks. The ensemble of simulations represent transient, 3-D multi-phase reactive transport of CO 2 and brine leaked from a sequestration reservoir, via a leaky wellbore, into an unconfined aquifer. Key characteristics of the aquifer, including thickness, mean permeability, background hydraulic gradient, and geostatistical measures of aquifer heterogeneity, were all considered uncertain parameters. Complex temporally-varying CO 2 and brine leak rate scenarios were simulated using a heuristic scheme with ten uncertain parameters. The simulations collectively predict the spatial and temporal evolution of CO 2 and brine plumes over 200 years in a shallow aquifer under a wide range of leakage scenarios and aquifer characteristics. Using spatial data from an existing network of shallow drinking water wells in the Edwards Aquifer, TX, as one illustrative example, we calculated the likelihood of leakage detection by groundwater sampling. In this monitoring example, there are 128 wells available for sampling, with a density of about 2.6 wells per square kilometer. If the location of the leak is unknown a priori, a reasonable assumption in many cases, we found that the leak would be detected in at least one of the monitoring wells in less than 10% of the scenarios considered. This is because plume sizes are relatively small, and so the probability of detection decreases rapidly with distance from the leakage point. For example, 400m away from the leakage point there is less than 20% chance of detection. We then compared the effectiveness of groundwater quality sampling to shallow aquifer and/or reservoir pressure monitoring. For the Edwards Aquifer example, pressure monitoring in the same monitoring well network was found to be even less effective that groundwater quality monitoring. This is presumably due to the unconfined conditions and relatively high permeability, so pressure perturbations quickly dissipate. Although specific results may differ from site to site, this type of analysis should be useful to site operators and regulators when selecting leak detection strategies. Given the spatial characteristics of a proposed monitoring well network, probabilities of leakage detection can be rapidly calculated using this methodology. Although conditions such as these may not be favorable for leakage detection in shallow aquifers, leakage detection could be much more successful in the injection reservoir. We demonstrate proof-of-concept for this hypothesis, presenting a simulation where there is measurable pressure change at the injection well due to overpressurization, fault rupture, and consequent leakage up the fault into intermediate and shallow aquifers. The size of the detectible pressure change footprint is much larger in the reservoir than in either of the overlying aquifers. Further exploration of the range of conditions for which this technique would be successful is the topic of current study.

54 ENVIRONMENTAL SCIENCES↗