Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Experimental Developments for the Lamb Shift Investigation in Heavy Ions

Novel high-resolution spectrometer setups are presently commissioned for X-ray experiments at the Experimental Storage Ring (ESR) at GSI, Darmstadt, aiming at an accurate determination of QED corrections in the critical field limit via an accurate determination of the ground-state binding energy in a high-Z, H-like ion. Until now for H-like uranium, an accuracy of 1% could be reached in an experiment performed at the electron cooler, due to the deceleration capability of the ESR. A further improvement by almost one order of magnitude is envisaged by a transmission x-ray spectrometer setup in the FOcusing Compensated Asymmetric Laue (FOCAL) geometry, as well as by the implementation of high-resolution microcalorimeter devices.Here we report on the latest commissioning experiment of a two-arm transmission X-ray spectrometer, along with high-performance position-sensitive microstrip germanium detectors. Due to a photon efficiency of only 10{sup -8}, the position sensitivity, as well as the energy and time resolution of segmented solid-state germanium detectors, are absolutely essential for the experiment. In combination with the FOCAL spectrometer, these position-sensitive detectors permit the simultaneous measurement of all energies in the regime of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of Atomic and Molecular Physics for Chinese Scientific Data Community

We will report some progress of Atomic and Molecular Physics in China, especially for national needs such as astrophysics, energy, environment and medical physics research programs etc.. Various theoretical activities and experimental activities have been initiated by Chinese Research Association of Atomic and Molecular Data. For example, in order to manage huge sets of energy levels for atoms (atomic ions) required in our national energy and astrophysical research programs, we focus a manageable set of physical parameters in multichannel quantum defect theory (MQDT) based on which the huge atomic energy levels can be reproduced without missing any one. We also elucidate the physical meanings of such MQDT physical parameters which are related to scattering matrices of electron-ion collisions. Huge sets of collision data can also be managed. The scenario can also be extended to molecular data required in our national environmental research programs. In order to provide benchmark examinations of atomic and molecular data, we also report some progresses of atomic and molecular experimental measurements such as electron scattering experiments, storage ring experiments, laser spectroscopy and molecular beam experiments etc.. In order to pursue precise measurements in physics, there are also some attempts to set up atomic experiments by laser cooling techniques. Some atomic interference experiments are also reported.

74 ATOMIC AND MOLECULAR PHYSICS↗

Precise Lamb Shift Measurements in Hydrogen-Like Heavy Ions--Status and Perspectives

The precise determination of the energy of the Lyman {alpha}1 and {alpha}2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. For the first time, a calorimetric low-temperature detector was applied in an experiment to precisely determine the transition energy of the Lyman lines of lead ions {sup 207}pb{sup 81+} at the Experimental Storage Ring (ESR) at GSI. The detectors consist of silicon thermistors, provided by the NASA/Goddard Space Flight Center, and Pb or Sn absorbers to obtain high quantum efficiency in the energy range of 40-80 keV, where the Doppler-shifted Lyman lines are located. The measured energy of the Lyman {alpha}1 line, E(Ly-{alpha}1, {sup 207}Pb{sup 81+}) = (77937{+-}12{sub stat}{+-}23{sub syst}) eV, agrees within errors with theoretical predictions. The systematic error is mainly due to uncertainties in the non-linear energy calibration of the detectors as well as the relative position of detector and gas-jet target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Type of X-ray Condenser Lenses with Large Apertures Fabricated by Rolling of Structured Films

In order to meet the demand for X-ray lenses with large apertures and, hence, photon flux, a new type of X-ray lenses has been developed: Rolled prismatic X-ray lenses feature a vast number of refracting surfaces to increase transparency and aperture, respectively. Prototypes of such lenses have been fabricated by molding and rolling of a structured polyimide film. In this work, rolled prismatic X-ray lenses are pictured, and results of first tests performed at the ANKA storage ring in Karlsruhe are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microangiography in Living Mice Using Synchrotron Radiation

Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 {mu}m/pixel. The optimal dose of contrast agent is 100 {mu}l per injection and the injecting rate is 33 {mu}l/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43{+-}6.8 {mu}m. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of high-repetition-rate laser pump/x-ray probe methodologies for synchrotron facilities

We describe our implementation of a high repetition rate (54 kHz-6.5 MHz), high power (>10 W), laser system at the 7ID beamline at the Advanced Photon Source for laser pump/x-ray probe studies of optically driven molecular processes. Laser pulses at 1.06 {mu}m wavelength and variable duration (10 or 130 ps) are synchronized to the storage ring rf signal to a precision of {approx}250 fs rms. Frequency doubling and tripling of the laser radiation using nonlinear optical techniques have been applied to generate 532 and 355 nm light. We demonstrate that by combining a microfocused x-ray probe with focused optical laser radiation the requisite fluence (with <10 {mu}J/pulse) for efficient optical excitation can be readily achieved with a compact and commercial laser system at megahertz repetition rates. We present results showing the time-evolution of near-edge x-ray spectra of a well-studied, laser-excited metalloporphyrin, Ni(II)-tetramesitylporphyrin. The use of high repetition rate, short pulse lasers as pump sources will dramatically enhance the duty cycle and efficiency in data acquisition and hence capabilities for laser-pump/x-ray probe studies of ultrafast structural dynamics at synchrotron sources.

36 MATERIALS SCIENCE↗

Excitation of transverse dipole and quadrupole modes in a pure ion plasma in a linear Paul trap to study collective processes in intense beams

Transverse dipole and quadrupole modes have been excited in a one-component cesium ion plasma trapped in the Paul Trap Simulator Experiment (PTSX) in order to characterize their properties and understand the effect of their excitation on equivalent long-distance beam propagation. The PTSX device is a compact laboratory Paul trap that simulates the transverse dynamics of a long, intense charge bunch propagating through an alternating-gradient transport system by putting the physicist in the beam's frame of reference. A pair of arbitrary function generators was used to apply trapping voltage waveform perturbations with a range of frequencies and, by changing which electrodes were driven with the perturbation, with either a dipole or quadrupole spatial structure. The results presented in this paper explore the dependence of the perturbation voltage's effect on the perturbation duration and amplitude. Perturbations were also applied that simulate the effect of random lattice errors that exist in an accelerator with quadrupole magnets that are misaligned or have variance in their field strength. The experimental results quantify the growth in the equivalent transverse beam emittance that occurs due to the applied noise and demonstrate that the random lattice errors interact with the trapped plasma through the plasma's internal collective modes. Coherent periodic perturbations were applied to simulate the effects of magnet errors in circular machines such as storage rings. The trapped one component plasma is strongly affected when the perturbation frequency is commensurate with a plasma mode frequency. The experimental results, which help to understand the physics of quiescent intense beam propagation over large distances, are compared with analytic models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and assembly of a superconducting undulator for the advanced photon source

A prototype superconducting undulator magnet (SCU0) has been built at the Advanced Photon Source (APS) of Argonne National Laboratory (ANL) and has successfully completed both cryogenic performance and magnetic measurement test programs. The SCU0 closed loop, zero-boil-off cryogenic system incorporates high temperature superconducting (HTS) current leads, cryocoolers, a LHe reservoir supplying dual magnetic cores, and an integrated cooled beam chamber. This system presented numerous challenges in the design, fabrication, and assembly of the device. Aspects of this R and D relating to both the cryogenic and overall assembly of the device are presented here. The SCU0 magnet has been installed in the APS storage ring.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cryogenic performance of a cryocooler-cooled superconducting undulator

A cryocooler-cooled superconducting undulator has been installed and operated with beam at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The device consists of a dual-core 42-pole magnet structure that is cooled to 4.2 K with a system of four cryocoolers operating in a zero-boil-off configuration. This effort represents the culmination of a development program to establish concept feasibility and evaluate cryostat design and cryocooler-based refrigeration. Cryostat performance is described including cool-down/warm-up, steady-state operation, cooling margin, and the impact of beam during operation in the APS storage ring. Plans for future devices with longer magnets, which will incorporate lessons learned from the development program, are also discussed.

43 PARTICLE ACCELERATORS↗

Electron gun jitter effects on beam bunching

For routine operation of Beijing Electron Positron Collider II (BEPCII) linac, many factors may affect the beam bunching process directly or indirectly. We present the measurements and analyses of the gun timing jitter, gun high voltage jitter, and beam energy at the exit of the standard acceleration section of the linac quantitatively. Almost 80 mV and more than 200 ps of gun high voltage and time jitters have ever been measured, respectively. It was analyzed that the gun timing jitter produced severe effects on beam energy than the gun high voltage jitter, if the timing jitter exceeded 100 ps which eventually deteriorates both the beam performance and the injection rate to the storage ring.

43 PARTICLE ACCELERATORS↗

Development of soft X-ray polarized light beamline on Indus-2 synchrotron radiation source

This article describes the development of a soft x-ray beamline on a bending magnet source of Indus-2 storage ring (2.5 GeV) and some preliminary results of x-ray absorption spectroscopy (XAS) measurements using the same. The beamline layout is based on a spherical grating monochromator. The beamline is able to accept synchrotron radiation from the bending magnet port BL-1 of the Indus-2 ring with a wide solid angle. The large horizontal and vertical angular acceptance contributes to high photon flux and selective polarization respectively. The complete beamline is tested for ultrahigh vacuum (UHV) ∼ 10{sup −10} mbar. First absorption spectrum was obtained on HOPG graphite foil. Our performance test indicates that modest resolving power has been achieved with adequate photon flux to carry out various absorption experiments.

43 PARTICLE ACCELERATORS↗

Precise method of compensating radiation-induced errors in a hot-cathode-ionization gauge with correcting electrode

To compensate pressure-measurement errors caused by a synchrotron radiation environment, a precise method using a hot-cathode-ionization-gauge head with correcting electrode, was developed and tested in a simulation experiment with excess electrons in the SPring-8 storage ring. This precise method to improve the measurement accuracy, can correctly reduce the pressure-measurement errors caused by electrons originating from the external environment, and originating from the primary gauge filament influenced by spatial conditions of the installed vacuum-gauge head. As the result of the simulation experiment to confirm the performance reducing the errors caused by the external environment, the pressure-measurement error using this method was approximately less than several percent in the pressure range from 10{sup −5} Pa to 10{sup −8} Pa. After the experiment, to confirm the performance reducing the error caused by spatial conditions, an additional experiment was carried out using a sleeve and showed that the improved function was available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The vibrational dependence of dissociative recombination: Rate constants for N{sub 2}{sup +}

Dissociative recombination rate constants are reported with electron temperature dependent uncertainties for the lowest 5 vibrational levels of the N{sub 2}{sup +} ground state. The rate constants are determined from ab initio calculations of potential curves, electronic widths, quantum defects, and cross sections. At 100 K electron temperature, the rate constants overlap with the exception of the third vibrational level. At and above 300 K, the rate constants for excited vibrational levels are significantly smaller than that for the ground level. It is shown that any experimentally determined total rate constant at 300 K electron temperature that is smaller than 2.0 × 10{sup −7} cm{sup 3}/s is likely to be for ions that have a substantially excited vibrational population. Using the vibrational level specific rate constants, the total rate constant is in very good agreement with that for an excited vibrational distribution found in a storage ring experiment. It is also shown that a prior analysis of a laser induced fluorescence experiment is quantitatively flawed due to the need to account for reactions with unknown rate constants. Two prior calculations of the dissociative recombination rate constant are shown to be inconsistent with the cross sections upon which they are based. The rate constants calculated here contribute to the resolution of a 30 year old disagreement between modeled and observed N{sub 2}{sup +} ionospheric densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ortho:para ratio of H{sub 3}{sup +} in laboratory and astrophysical plasmas

The discovery of H{sub 3}{sup +} in the diffuse interstellar medium has dramatically changed our view of the cosmic-ray ionization rate in diffuse molecular clouds. However, another surprise has been that the ortho:para ratio of H{sub 3}{sup +} in these clouds is inconsistent with the temperature derived from the excitation of H{sub 2}, the dominant species in these clouds. In an effort to understand this discrepancy, we have embarked on an experimental program to measure the nuclear spin dependence of the dissociative electron recombination rate of H{sub 3}{sup +} using the CRYRING and TSR ion storage rings. We have also performed the first measurements of the reaction H{sub 3}{sup +}+H{sub 2}→H{sub 2}+H{sub 3}{sup +} below room temperature. This reaction is likely the most common bimolecular reaction in the universe, and plays an important role in interconverting ortho- and para-H{sub 3}{sup +}. Finally, we have constructed a steady-state chemical model for diffuse clouds, which takes into account the spin-dependence of the formation of H{sub 3}{sup +}, its electron recombination, and its reaction with H{sub 2}. We find that the ortho:para ratio of H{sub 3}{sup +} in diffuse clouds is likely governed by a competition between dissociative recombination and thermalization by reactive collisions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dissociative recombination and mutual neutralization of heavier molecular ions: C{sub 10}H{sub 8}{sup +}, WF{sub 5}{sup +}, and C{sub n}F{sub m}{sup +}

Dissociative recombination (DR) rate coefficients for the naphthalene cation, C{sub 10}H{sub 8}{sup +}, and WF{sub 5}{sup +}, and mutual neutralization (MN) rate coefficients for these species and five C{sub n}F{sub m}{sup +} ions, were determined at 300 K using variable electron and neutral density attachment mass spectrometry (VENDAMS). DR proceeds at 9 ± 3 × 10{sup −7} cm{sup 3} s{sup −1} for C{sub 10}H{sub 8}{sup +} and at 6.1 ± 1.4 × 10{sup −7} cm{sup 3} s{sup −1} for WF{sub 5}{sup +}. Consistent with previous results, MN for the polyatomic cations with the halide anions Cl{sup −}, Br{sup −}, and I{sup −} exhibits an approximate μ{sup −1/2} reduced mass dependence of the reactant partners, demonstrating that ion collision velocities influence the rate coefficients. This work is an extension of VENDAMS to systems, where low reactant concentrations are necessary to avoid significant reaction of product ions with the neutral precursor, i.e., conditions not suitable for traditional flowing afterglow measurements, as well as to ions of masses > ∼ 100 Da, which are not amenable to the study of DR in magnetic storage rings. Our results expand the sparse literature on DR and MN of heavier ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Beam based alignment and its relevance in Indus-2

Initially in the Indus-2 storage ring, the closed orbit distortion (COD) could be best corrected to 1.3 mm rms in the horizontal and 0.43 mm rms in the vertical plane. The strength of the corrector magnets required high values for COD correction. This revealed that offsets in COD readout by the beam position monitors (BPMs) played a role in not achieving a rms COD lower than the above value. Thus, the offset between the electrical center of BPMs and the magnetic center of the nearest quadrupole magnet could be estimated using the beam based alignment (BBA) method. It prefers that the quadrupole magnet is able to be controlled individually and active shunt power supply (ASPS) system was designed for this purpose that works efficiently. This paper describes the methodology of BBA, topology of ASPS and its performance, and COD minimization using the measured BPM offsets. After BBA, the COD could be reduced to 0.45 mm rms and 0.2 mm rms in horizontal and vertical planes, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-field transmission x-ray microscope for time-resolved imaging of magnetic nanostructures

Sub-nanosecond magnetization dynamics of small permalloy (Ni{sub 80}Fe{sub 20}) elements has been investigated with a new full-field transmission microscope at the soft X-ray beamline P04 of the high brilliance synchrotron radiation source PETRA III. The soft X-ray microscope generates a flat-top illumination field of 20 μm diameter using a grating condenser. A tilted nanostructured magnetic sample can be excited by a picosecond electric current pulse via a coplanar waveguide. The transmitted light of the sample plane is directly imaged by a micro zone plate with < 65 nm resolution onto a 2D gateable X-ray detector to select one particular bunch in the storage ring that probes the time evolution of the dynamic information successively via XMCD spectromicroscopy in a pump-probe scheme. In the experiments it was possible to generate a homogeneously magnetized state in patterned magnetic layers by a strong magnetic Oersted field pulse of 200 ps duration and directly observe the recovery to the initial flux-closure vortex patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tolerance analyses of a quadrupole magnet for advanced photon source upgrade

Given physics requirements, the mechanical fabrication and assembly tolerances for storage ring magnets can be calculated using analytical methods [1, 2]. However, this method is not easy for complicated magnet designs [1]. In this paper, a novel method is proposed to determine fabrication and assembly tolerances consistent with physics requirements, through a combination of magnetic and mechanical tolerance analyses. In this study, finite element analysis using OPERA is conducted to estimate the effect of fabrication and assembly errors on the magnetic field of a quadrupole magnet and to determine the allowable tolerances to achieve the specified magnetic performances. Based on the study, allowable fabrication and assembly tolerances for the quadrupole assembly are specified for the mechanical design of the quadrupole magnet. Next, to achieve the required assembly level tolerances, mechanical tolerance stackup analyses using a 3D tolerance analysis package are carried out to determine the part and subassembly level fabrication tolerances. This method can be used to determine the tolerances for design of other individual magnets and of magnet strings.

43 PARTICLE ACCELERATORS↗