Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Link Adaptation for Mitigating Earth-To-Space Propagation Effects on the NASA SCaN Testbed

In Earth-to-Space communications, well-known propagation effects such as path loss and atmospheric loss can lead to fluctuations in the strength of the communications link between a satellite and its ground station. Additionally, the typically unconsidered effect of shadowing due to the geometry of the satellite and its solar panels can also lead to link degradation. As a result of these anticipated channel impairments, NASA's communication links have been traditionally designed to handle the worst-case impact of these effects through high link margins and static, lower rate, modulation formats. The work presented in this paper aims to relax these constraints by providing an improved trade-off between data rate and link margin through utilizing link adaptation. More specifically, this work provides a simulation study on the propagation effects impacting NASA's SCaN Testbed flight software-defined radio (SDR) as well as proposes a link adaptation algorithm that varies the modulation format of a communications link as its signal-to-noise ratio fluctuates. Ultimately, the models developed in this work will be utilized to conduct real-time flight experiments on-board the NASA SCaN Testbed.

software defined radio↗

In-Space Networking On NASA's SCaN Testbed

The NASA Space Communications and Navigation (SCaN) Testbed, an external payload onboard the International Space Station, is equipped with three software defined radios (SDRs) and a programmable flight computer. The purpose of the Testbed is to conduct inspace research in the areas of communication, navigation, and networking in support of NASA missions and communication infrastructure. Multiple reprogrammable elements in the end to end system, along with several communication paths and a semi-operational environment, provides a unique opportunity to explore networking concepts and protocols envisioned for the future Solar System Internet (SSI). This paper will provide a general description of the system's design and the networking protocols implemented and characterized on the testbed, including Encapsulation, IP over CCSDS, and Delay-Tolerant Networking (DTN). Due to the research nature of the implementation, flexibility and robustness are considered in the design to enable expansion for future adaptive and cognitive techniques. Following a detailed design discussion, lessons learned and suggestions for future missions and communication infrastructure elements will be provided. Plans for the evolving research on SCaN Testbed as it moves towards a more adaptive, autonomous system will be discussed.

space networks↗

Radiation, Smoke and Clouds Observed in the Southeastern Atlantic With the Research Scanning Polarimeter During ORACLES

The ObseRvations of Aerosols above Clouds and their interactions (ORACLES) project is making a series of field deployments to the southeastern Atlantic with NASA ER-2 and P3 aircraft to acquire both detailed remote sensing observations and in situ measurements of the aerosols and clouds in that region. This area is home to one of the largest low-level cloud decks on Earth that is seasonally affected by vast plumes of smoke from biomass burning, which in effect provides a natural experiment testing the radiative and microphysical interactions between the smoke and the clouds. The downward solar radiation at the surface, or cloud top, is always reduced by the presence of smoke. However, whether the amount of sunlight reflected back out to space is increased, or decreased by the presence of smoke is sensitively dependent on the brightness of the clouds and the fraction of light that the smoke absorbs each time light hits a smoke particle. In this study we use data from the Research Scanning Polarimeter, an along track scanning instrument, that provides measurements of the Stokes parameters I, Q and U at 410, 470, 555, 670, 865, 960, 1590, 1880 and 2260 nm at 150 viewing angles over a range of +/- 60° from nadir for each contiguous sub-aircraft pixel (~ 300 m in size). A retrieval algorithm is applied to the data acquired with a table look up technique, similar to that of the operational POLDER algorithm, to provide a first guess of the complex refractive index, optical depth and size distribution of the smoke particles together with cloud droplet size and optical depth. A subsequent iterative fitting procedure, where the fact that the doubling/adding method allows the construction of the Green's function for the radiative transfer equation, is used to obtain an efficient and statistically optimal estimate of the aerosol and cloud retrieval parameters. These retrieval parameters are evaluated against in situ observations, when available, and the optical depth and intensive lidar variables that are measured by the High Spectral Resolution Lidar 2. Finally, the aerosol and cloud retrievals are used to evaluate the variations in top of the atmosphere, surface/cloud top shortwave radiative forcing and atmospheric absorption that are caused by variations in the smoke and clouds.

Cairns, Brian↗

Updating the Space Communications and Navigation (SCaN) Link Tool Executable Software to Version 5

NASA’s Space Communications and Navigation (SCaN) program is responsible for providing space communication channels in low Earth orbit, geosynchronous orbit, and deep space for a variety of space missions. The SCaN Link Tool is a standalone, executable, and personal computer (PC)-based software operated via a user interface, which provides NASA civil servants and contractors, as well as the public by way of the tool’s inclusion in the NASA Software Catalog, with in-depth satellite communications link analysis capability. Version 4 of the tool was built using PythonTM (Python Software Foundation) with the help of libraries such as NumPy and SciPy for numerical calculations, Matplotlib for graphical visualizations, and PyQt5 for the graphical user interface. It utilizes radiofrequency (RF) and optical communications link analysis calculations to give users the ability to input known link parameters and calculate select link performance outputs. With the development of the next-generation architecture for space satellite communications in the coming decade, NASA will benefit by having more in-depth communications link analysis tools at its disposal. The tool’s update from version 4 to version 5 aims to provide higher output value accuracy, the ability to solve for a more diverse set of output variables, as well as analog and digital repeater capabilities. Options included in the tool’s functionality, such as the ability to save configuration parameter values, graphs, and results, as well as the provision of default parameter values, increase the tool’s versatility. Users will have access to in-depth, accurate communications link analysis as more advanced satellite constellations are designed and deployed by NASA and the growing commercial aerospace community.

Green, Jack L.↗

Results from the Deep Convective Clouds-Based Response Versus Scan-Angle Characterization for the MODIS Reflective Solar Bands

The Terra and Aqua Moderate-Resolution Imaging Spectroradiometer (MODIS) scan mirror reflectance is a function of the angle of incidence (AOI) and was characterized prior to launch by the instrument vendor. The relative change of the prelaunch response versus scan angle (RVS) is tracked and linearly scaled on-orbit using observations at two AOIs of 11.2° and 50.2° corresponding to the moon view and solar diffuser, respectively. As the missions continue to operate well beyond their design life of six years, the assumption of linear scaling between the two AOIs is known to be inadequate in accurately characterizing the RVS, particularly at short wavelengths. Consequently, an enhanced approach of supplementing the on-board measurements with response trends from desert pseudoinvariant calibration sites (PICS) was formulated in MODIS Collection 6 (C6). An underlying assumption for the continued effectiveness of this approach is the long-term (multiyear) and short-term (month to month) stability of the PICS. Previous work has shown that the deep convective clouds (DCC) can also be used to monitor the onorbit RVS performance with less trend uncertainties compared with desert sites. In this paper, the raw sensor response to the DCC is used to characterize the on-orbit RVS on a band and mirror-side basis. These DCC-based RVS results are compared with those of C6 PICS-based RVS, showing an agreement within 2% observed in most cases. The pros and cons of using a DCC-based RVS approach are also discussed in this paper. Although this reaffirms the efficacy of the C6 PICS-based RVS, the DCC-based RVS approach presents itself as an effective alternative for future considerations. Potential applications of this approach to other instruments, such as Suomi National Polarorbiting Partnership, Joint Polar Satellite Systems, and Visible Infrared Imaging Radiometer Suite, are also discussed.

Angal, Amit↗

Probe Compensation in Cylindrical Near-Field Scanning: A Novel Simulation Methodology

Probe pattern compensation is essential in near-field scanning geometry, where there is a greatneed to accurately know far-field pattern at wide angular range. This paper focuses on a novelformulation and computer simulation to determine the precise need for and effect of probecompensation in cylindrical near-field scanning. The methodology is applied to a linear test arrayantenna and the NASA scatterometer radar antenna. The formulation is based on representing theprobe (circular aperture) by its equivalent tangential magnetic currents. The interaction between theprobe equivalent aperture currents and the test antenna fields is obtained with the application ofreciprocity theorem. This allows us to obtain the probe vector output pickup integral which isproportional to the amplitude and phase of the electric field induced in the probe aperture with respectto its position to the test antenna.

Rahmat-Samii, Y↗

Improvements in the on-orbit response versus scan-angle characterization for the MODIS ocean color bands

On-orbit characterization of the response versus scan-angle (RVS) is one of the most challenging aspects of the reflective solar band (RSB) calibration for the MODIS instruments onboard the Terra and Aqua spacecraft. The degradation of the solar diffuser, together with the lack of onboard calibrators (OBCs) to cover additional scan angles, other than the one for the lunar observations, has resulted in the use of Earth view responses from the pseudo-invariant desert sites to track the on-orbit RVS changes. This approach has been implemented in Collection 6 (C6) and C6.1 for bands 1-4, 8 and 9 of both instruments and also band 10 of Terra MODIS. As the missions continue to operate over a decade beyond their designed life and the instrument optics continue to degrade, it is expected that the OBC based RVS currently applied to other bands, specifically the high-gain ocean bands, will be inadequate to maintain the long-term calibration stability. An interband calibration approach is formulated and implemented in this paper. The proposed approach relies on the use of a spectrally matching stable reference band to evaluate the long-term calibration stability of the high-gain ocean bands that typically saturate while viewing the selected calibration deserts. Results from this approach indicate a noticeable drift for Terra MODIS bands 11 and 12 whereas the Aqua bands continue to show excellent temporal stability. These results are consistent with the corrections derived by the NASA Ocean Biology Processing Group (OBPG) and are expected to have minimum impacts on the downstream science products.

MODIS↗

Response versus scan angle derived from polarization testing for JPSS-2 VIIRS

For the VIIRS (Visible Infrared Imaging Radiometer Suite) onboard the JPSS (Joint Polar Satellite System) missions, extensive ground testing is performed to characterize some aspects of the sensor that cannot be measured once the instruments are on-orbit. Two such parameters are the response versus scan angle (RVS) and polarization sensitivity. The pre-launch tests that characterize these parameters share a number of similarities. This paper will show that the polarization test data can be used to generate RVS results that are comparable to the results produced from the RVS test itself. The polarization test data also provides additional information about how the RVS changes with both scan angle and polarization state.

JPSS↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

Rohit Bhartia↗

Individual Beam Size And Length Measurements at the SLC Interaction Point Derived From the Beam Energy Loss During a Beam Beam Deflection Scan

At the Interaction Point (IP) of the SLC Final Focus, beam-beam deflection scans routinely provide a measurement of the sum in quadrature of the electron and positron transverse beam sizes, but no information on the individual beam sizes. During the 1996 SLC run, an upgrade to the Final Focus beam position monitor system allowed a first measurement of the absolute beam energy loss of both beams on each step of the deflection scan. A fit to the energy loss distributions of the two beams provides a measurement not only of the individual transverse beam sizes at the IP but also of the individual bunch lengths.

43 PARTICLE ACCELERATORS↗

Development of Scanning Near-Field Ultrasound Holography as an Add-On Module for AFM systems

The project aimed to develop a standalone module for Atomic Force Microscope systems that the biological and environmental research community could use to image and quantify to a greater extent the interactions between nanoparticles and cells. If successful, it would enable the thousands of biological and environmental researchers with access to atomic force microscopes to perform scanning near field ultrasound holography to image nanoparticle interactions with cells. Over the course of this effort, grantees were able to develop a standalone module capable of performing scanning near field ultrasound holography on a variety of commercial systems. The add-on module was tested on systems from 3 of the major Atomic Force Microscope manufacturers (Veeco, JEOL and Park Systems). Furthermore, the investigators believe that the hardware developed will be capable of performing the technique on any AFM with standard signal access modules. The discrete components previously used to perform the SNFUH technique could cost upward of $\$$40,000. Beyond the cost issue, the components are bulky and cumbersome to work with because of the wiring needed between each of the components when implementing the technique. NanoSonix was able to dramatically reduce both the cost and complexity of implementing SNFUH, developing two functional versions of an add-on module (A&B) using National Instruments hardware as put forth in the proposal. More significantly, NanoSonix exceeded the aims of the proposal by developing completely custom electronics that should enable an almost order of magnitude cost reduction while improving the capability versus the discrete componentry. Because potential biological systems are so complex, biological applications of the technique are very diverse and require very distinct domain knowledge. This inhibits the utilization widespread adoption and penetration of new metrology techniques. Northwestern University and NanoSonix has made it both possible and practical for widespread adoption of the technique through the development of a standalone system with order of magnitude cost reduction and significant reduction in complexity. NanoSonix believes that it can produce the add-on modules and make them available to the academic research community at a price point below $\$$10,000, thereby enabling the biological research community to hardness the over 30,000 AFMs in existence around the world today, approximately 18,000 of which reside in the United States at a very modest incremental cost. Finally, we were able to implement a multi-frequency function generator and simultaneous multi-frequency lock-in amplifier with an internal reference frequency (which significantly simplifies the experimental setup) that it believes could lay the foundation for future non-destructive nanoscale 3-D tomography of buried and embedded sub-structures in cells and tissues. To date, we has been unable to find multiple frequency combinations which yield sufficiently strong mixing at the tip-sample interaction, but believes it is conceptually possible and doing so would enable the use of frequency dependent phase shift to better characterize the subsurface structures. Taken together, we believes that this work has materially advanced the prospects of enabling researchers to develop time-resolved cellular uptake of the nanoparticles used for drug delivery, cancer therapies, gene delivery and gene silencing and to assess cellular uptake of nanoparticles for environmental monitoring/remediation/impact.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Auto-calibrated scanning-angle prism-type total internal reflection microscopy for nanometer-precision axial position determination and optional variable-illumination-depth pseudo total internal reflection microscopy

A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.

36 MATERIALS SCIENCE↗

Automatic tool alignment in a backscatter x-ray scanning system

Technologies pertaining to backscatter x-ray scanning systems are described herein. The backscatter x-ray scanning system includes an x-ray source, which directs collimated x-rays along a plurality of output vectors towards a target. A detector detects diffusely reflected x-rays subsequent to respective collimated x-rays impacting the target, and outputs signals indicative of parameters of the detected x-rays. An image processing system generates an x-ray image based upon parameters of the detected x-rays, wherein each pixel in the image corresponds to a respective output vector. A user selects a particular portion of the image, and a tool is positioned such that its directional axis is coincident with the output vector corresponding to at least one pixel in the portion of the image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CS-Studio Scan System Parallelization

For several years, the Control System Studio (CS-Studio) Scan System has successfully automated the operation of beam lines at the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and Spallation Neutron Source (SNS). As it is applied to additional beam lines, we need to support simultaneous adjustments of temperatures or motor positions. While this can be implemented via virtual motors or similar logic inside the Experimental Physics and Industrial Control System (EPICS) Input/Output Controllers (IOCs), doing so requires a priori knowledge of experimenters requirements. By adding support for the parallel control of multiple process variables (PVs) to the Scan System, we can better support ad hoc automation of experiments that benefit from such simultaneous PV adjustments.

43 PARTICLE ACCELERATORS↗

Automatic tool alignment in a backscatter X-ray scanning system

Technologies pertaining to backscatter x-ray scanning systems are described herein. The backscatter x-ray scanning system includes an x-ray source, which directs collimated x-rays along a plurality of output vectors towards a target. A detector detects diffusely reflected x-rays subsequent to respective collimated x-rays impacting the target, and outputs signals indicative of parameters of the detected x-rays. An image processing system generates an x-ray image based upon parameters of the detected x-rays, wherein each pixel in the image corresponds to a respective output vector. A user selects a particular portion of the image, and a medical device is positioned such that its directional axis is coincident with the output vector corresponding to at least one pixel in the portion of the image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning measurement of Seebeck coefficient of a heated sample

A novel scanning Seebeck coefficient measurement technique is disclosed utilizing a cold scanning thermocouple probe tip on heated bulk and thin film samples. The system measures variations in the Seebeck coefficient within the samples. The apparatus may be used for two dimensional mapping of the Seebeck coefficient on the bulk and thin film samples. This technique can be utilized for detection of defective regions, as well as phase separations in the sub-mm range of various thermoelectric materials.

36 MATERIALS SCIENCE↗

Band Excitation for Scanning Probe Microscopy

The Band Excitation (BE) technique for scanning probe microscopy uses a precisely determined waveform that contains specific frequencies to excite the cantilever or sample in an atomic force microscope to extract more information, and more reliable information from a sample. There are a myriad of details and complexities associated with implementing the BE technique. There is therefore a need to have a user friendly interface that allows typical microscopists access to this methodology. This software enables users of atomic force microscopes to easily: build complex band-excitation waveforms, set-up the microscope scanning conditions, configure the input and output electronics for generate the waveform as a voltage signal and capture the response of the system, perform analysis on the captured response, and display the results of the measurement.

Jesse, Stephen↗