Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

QA/QC of the East River, Colorado, discharge and geochemical time series datasets (Almont, BCC, and Pump House) to be used for modeling of hydrogeochemical balance

The following datasets were QA/QC-ed (Quality Assurance/Quality Control): 1. Brush Creek Confluence (BCC) discharge data (from Helen Malenda, USGS, Colorado School of Mines), which were calculated using the pressure transducer data and rating curves. The original 15 min time series data were presented as mean daily discharge. 2. Almont discharge data from United States Geological Survey (USGS). The original data were in 15 min time intervals, and were averaged to mean daily discharge time series. 3. Pump House discharge data as mean daily discharge (downloaded from the SFA portal). 4. BCC and Pump House chemistry data from SFA data portal and/or original spreadsheets provided by Roelof Versteeg. The following challenging QA/QC problems of the datasets were resolved: Missing data with the duration of gaps up to >1 month; Duplicated dates; Anomalies and outliers of discharge and concentrations; Time stamps of measurements of the discharge and concentrations are not aligned (hydrogeochemical balance calculations require the timestamps to be aligned). All QA/QC-ed datasets are given as csv files. The csv files were prepared using the xts files with multiple worksheets, which are also included in the data packages. Figures of the QA/QC-ed datasets are given in the jpeg and pdf formats. The QA/QC-ed datasets have been used to quantify discharge and chemical concentrations in river water in order to understand riverine exports of water and dissolved constituents in the East River watershed. These datasets served as a basis in the presentation given by P. Fox et al. at the 2021 Goldschmidt Conference.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-199: How Number of Control Points Influences the Dynamic IMRT Plan Quality and Deliverability

Purpose: To study the influence of number of control points on plan quality and deliverability. Methods: Five previously treated patients of carcinoma of rectum were selected. Planning target volume (PTV) and organs at risk (OARs) i.e. bladder and bowel were contoured. Dynamic IMRT plans (6MV, 7-fields, 45Gy/25 fractions and prescribed at 95% isodose) were created in Eclipse (Varian medical system, Palo Alto, CA) treatment planning system (TPS) for Varian CL2300C/D linear-accelerator. Base plan was calculated with 166 control points, variable mode (Eclipse Default). For generating other plans, all parameters were kept constant, only number of control points (Fixed mode) was varied as follows: 100, 166 and 200. Then, plan quality was analyzed in terms of maximum and mean dose received by the PTV and OARs. For plan deliverability, TPS calculated fluence was verified with I’matriXX (IBA Dosimetry, Germany) array and compared with TPS dose-plane using gamma index criteria of 3% dose difference and 3mm distance to agreement (DTA). Total number of monitor units (MU) required to deliver a plan was also noted. Results: The maximum variation for the PTV maximum with respect to eclipse default control point (166) was 0.28% (0.14Gy). Similarly, PTV mean varied only up to 0.22 %( 0.11Gy). Bladder maximum and bladder mean varied up to 0.51% (0.24Gy) and 0.16% (0.06Gy). The variation for the bowel maximum and bowel mean was also only 0.39% (0.19Gy) and 0.33% (0.04Gy). Total MU was within 0.32 % (4MU). Average gamma pass rate using different control points for five patients are 98.75±0.33%, 99.37±0.09%, 99.29±0.12%, 98.14±0.13% and 99.25±0.14% respectively. Conclusion: Slight variation (<1%) in PTV and OARs maximum and mean doses was observed with varying number of control points. Monitor unit was also not varied much. Reducing number of control points did not showed any comprise in plan deliverability in terms of gamma index pass rate.

60 APPLIED LIFE SCIENCES↗

Thermomechanical Lift-Off and Recontacting of CdTe Solar Cells

Controlled delamination of thin-film photovoltaics (PV) post-growth can reveal interfaces that are critical to device performance yet are poorly understood because of their inaccessibility within the device stack. In this work, we demonstrate a technique to lift off thin-film solar cells from their glass substrates in a clean, reproducible manner by first laminating a polymeric backsheet to the device and then thermally shocking the system at low temperatures (T ≤ -30 degrees C). To enable clean delamination of diverse thin-film architectures, a theoretical framework is developed and key process control parameters are identified. Focusing on cadmium telluride (CdTe) devices, we show that the lamination temperature and device architecture control the quality of lift-off, while the rate at which the film stack is removed is controlled by the delamination temperature. Crack-free CdTe devices are removed and successfully recontacted, recovering up to 80% of the original device efficiency. The areal density of these devices is ~0.4 kg m -2 , a reduction of over an order of magnitude relative to their initial weight on glass. The framework developed here provides a pathway toward both the development of inexpensive, flexible PV with high specific power and the study of previously buried interfaces in thin-film architectures.

14 SOLAR ENERGY↗

The contributions of microclimatic information in advancing ecosystem science

Drawing upon over 100 years of scholarly work on microclimate, we first present an overview of the history, key references, and critical issues surrounding the collection and utilization of microclimate records in ecosystem studies. We place particular emphasis on addressing specific and pressing issues related to the applications of microclimate at the community-ecosystem-landscape level, excluding those of controlled experiment such as growth chambers and greenhouses. Specifically, we: (1) highlight some key issues concerning the collection, quality assurance/quality control (QA/QC), and utilization of microclimatic data in ecosystem studies; (2) revisit microclimatic responses to the structural changes of ecosystems and landscapes; and (3) emphasize the significance of microclimate in understanding major ecosystem/landscape processes and functions. Vapor pressure deficit (VPD) is particularly emphasized for its calculation and use because of its burgeoning applications in the literature. Case studies for each of the three thematic topics are provided with selected references to demonstrate challenges and solutions. As the scientific community gears up to enhance microclimatic stations, we envision significant increases in the use of smart sensors, wireless access, networking, open databases, and computational capabilities. Understanding and addressing some of the issues raised in this synthesis paper may help advance microclimate research and foster collaboration with other relevant disciplines, such as ecosystem science.

54 ENVIRONMENTAL SCIENCES↗

Ultrasonic Characterization of Ethylene Vinyl Acetate (EVA) Crosslinking for Quality Assurance and Lamination Process Control (US-Xlink)

Module makers strive to cut lamination processing times to enhance production throughput and reduce costs. If overdone, this might lead to poor EVA quality due to incomplete EVA crosslinking and a large concentration of potentially harmful reactants. Those deficiencies are frequently missed during production quality testing as initially their impact on power output is small. Additionally, the crosslinking agent is frequently inhomogeneously dispersed across the EVA foils such that local destructive characterization procedures such as differential scanning calorimetry (DSC), Soxhlet extraction, swelling methods, or mechanical tests provide only a limited amount of information. However, these defects and inhomogeneities can become considerably more important during field operation, dramatically reducing long-term power yield, and increasing LCOE. Examples of typical long-term module degradation modes relating to poor lamination process conditions include cell breakage, corrosion of the metallization, delamination, and local quality deficiencies. To provide reliable material characterization in a manufacturing setting, we devised a non-destructive technology that uses ultrasound to evaluate the quality of interface adhesion and the degree of crosslinking. As a calibration reference, DSC measurements were employed. Although the potential of ultrasonic approaches for this purpose has already been noted, those previous methods were generally limited to local qualitative measurements. Furthermore, variations in EVA thickness and temperature had a substantial impact on them. The solution we propose solves these limitations by employing ultrasonic absorption rather than relying solely on sound velocity data.

14 SOLAR ENERGY↗

Quality Optimization of Commercial FeCrAl Tube Production

The objectives of this report are to summarize the various process parameters and conditions that trigger premature failures during the production steps for Generation II ATF FeCrAl seamless tubes in commercially available manufacturing processes, and to suggest optimized processing routes and parameters to improve the quality and the material yield of commercial tube production. The production process steps include (1) the heat production process, (2) the master bar production process, and (3) the tube reduction process. For heat production, not only chemical composition control but also elimination of solidification defects in the vacuum induction–melted ingot are key. A hot-isostatic press helped in reducing and eliminating the internal, preexisting cracks in the ingot, which could be a source of premature failure (e.g., crack initiation from oxide particles) in the latter part of the tube production process. The master bars were produced by a hot-extrusion process. The area reduction ratio and the extrusion temperature are key to controlling the quality of the master bars and the grain structure. Because of the limited deformation ability of FeCrAl alloys, especially at ambient temperatures, a controlled, uniform grain structure with relatively small grains (<100 µm) is required at the beginning of the tube reduction process. Furthermore, a relatively small amount of area reduction per pass, combined with controlled inter-pass annealing, is important to achieve a reduction in failure events, a highly uniform wall thickness, concentricity, and a high-quality surface finish. Based on the knowledge obtained regarding process conditions, FeCrAl tube production with optimized process parameters is currently in progress. A portion of the final tube inventory was delivered in late June 2017. Cross-sectional microstructural characterization was completed for screening the quality of as-received tubes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In Situ Mechanochemical Modulation of Carbon Nanotube Forest Growth

Ordered synthesis of one-dimensional nanostructures, such as carbon nanotubes (CNTs), involves competition between the growth kinetics of individual structures, their physical entanglement, and intermolecular forces that cause coupling of structures in close proximity. Specifically, CNT synthesis by chemical vapor deposition can directly produce films and fibers by providing CNT growth sites in close proximity such that the CNTs self-align into macroscopic assemblies. Because CNTs are mechanically coupled during these processes, the question arises as to whether or not mechanical forces intrinsic to the formation of CNT ensembles influence the growth kinetics and quality of CNTs, as can be expected from fundamental theories of mechanochemistry. Here, we study how mechanical forces influence CNT growth by applying controlled compression to CNT forests in situ; and relate the outcomes quantitatively to the CNT morphology and lengthening rate. We find that applied forces inhibit the self-organization of CNTs into a forest and accelerate the termination of collective growth. By correlating in situ kinetics measurements with spatial mapping of CNT orientation and density by X-ray scattering, we find that the average growth rate of individual CNTs is also mechanically modulated; specifically, a 100-fold increase in force causes a 4-fold decrease in average CNT lengthening rate. Here, we attribute the slower growth kinetics to a stress-dependent increase of 0.02–0.16 eV in the effective activation energy for CNT growth. Via finite element modeling, we conclude that the force magnitudes that cause remodeling of the growing CNT network are less than the average strengths of adhesive contacts between CNTs. Last, we find that CNT growth rate and orientation can respond dynamically to changes in applied force, further demonstrating the mechanochemical nature of CNT growth and suggesting new approaches to control CNT quality and morphology in situ, with general application to other one-dimensional nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-C-BRD-03: Analysis of Accelerator Generated Text Logs for Preemptive Maintenance

Purpose: To develop a model to analyze medical accelerator generated parameter and performance data that will provide an early warning of performance degradation and impending component failure. Methods: A robust 6 MV VMAT quality assurance treatment delivery was used to test the constancy of accelerator performance. The generated text log files were decoded and analyzed using statistical process control (SPC) methodology. The text file data is a single snapshot of energy specific and overall systems parameters. A total of 36 system parameters were monitored which include RF generation, electron gun control, energy control, beam uniformity control, DC voltage generation, and cooling systems. The parameters were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and the parameter/system specification. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: the value of 1 standard deviation from the mean operating parameter of 483 TB systems, a small fraction (≤ 5%) of the operating range, or a fraction of the minor fault deviation. Results: There were 34 parameters in which synthetic errors were introduced. There were 2 parameters (radial position steering coil, and positive 24V DC) in which the errors did not exceed the limit of the I/MR chart. The I chart limit was exceeded for all of the remaining parameters (94.2%). The MR chart limit was exceeded in 29 of the 32 parameters (85.3%) in which the I chart limit was exceeded. Conclusion: Statistical process control I/MR evaluation of text log file parameters may be effective in providing an early warning of performance degradation or component failure for digital medical accelerator systems. Research is Supported by Varian Medical Systems, Inc.

07 ISOTOPE AND RADIATION SOURCES↗

Reinforcement Learning Control for Buildings Co-Optimizing Energy, Comfort, and Indoor Air Quality: An Annual Assessment

Efficient control of Heating, Ventilation, and Air Conditioning (HVAC) systems is crucial for optimizing energy use and maintaining indoor comfort in buildings. Traditional control methods, such as PID control, cannot handle energy use trade-offs among multiple components in the building energy system at a supervisory level. Reinforcement learning (RL) presents a promising solution, offering adaptive and data-driven control strategies that optimize performance over time. However, RL also faces several challenges, including the conflicts encountered in co-optimizing energy savings, occupant comfort, and indoor air quality, and the requirement for extensive interactions with the environment in training. We proposed a flexible simulation platform that integrates a hybrid model for RL training and designed an RL agent to control the entire central HVAC system, focusing on co-optimizing energy consumption, thermal comfort, and indoor air quality ($\text{CO}_{2}$ and PM2.5 concentrations). Finally, we evaluated the RL agent's performance over an annual cycle. Our findings indicate that the RL agent can effectively manage the HVAC system with 14.7 % energy savings annually and balance multiple objectives, which demonstrates significant potential for improving HVAC system control and sustainability in buildings.

Guo, Fangzhou↗

Hardware-in-the-Loop Co-Simulation Based Validation of Power System Control Applications

Renewables are key enablers for the realization of a sustainable energy supply but grid operators and energy utilities have to mange their intermittent behavior and limited storage capabilities by ensuring the security of supply and power quality. Advanced control approaches, automation concepts, and communication technologies have the potential to address these challenges by providing new intelligent solutions and products. However, the validation of certain aspects of such smart grid systems, especially advanced control and automation concepts is still a challenge. The main aim of this work therefore is to introduce a hardware-in-the-loop co-simulation-based validation framework which allows the simulation of large-scale power networks and control solutions together with real-world components. The application of this concept to a selected voltage control example shows its applicability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Savings of Occupancy-Based Controls in Office Buildings

Variable-air-volume (VAV) systems are used in many office buildings. The terminal’s minimum air flowrate set point is an important parameter that has significant impact on energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum air flowrate at a constant, irrespective of the occupancy status. Such practice may cause energy waste, ventilation and thermal comfort problems. This paper examines the potential of energy savings by occupancy-based controls (OBCs). The sensed occupancy information, either presence or the people count, is used to determine the air flowrate of terminal boxes, the thermostat set points, and the lighting as well. Using EnergyPlus, energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. Simulation results show that for the location of Baltimore, MD, the use of air-side economizer or not does indeed have significant impact on the comparison between the two OBC strategies. The OBC based on the occupant presence has about 13% whole-building energy savings no matter whether the air-side economizer is used in the AHU operation. However, for the OBC based on the people count, the percentage of energy savings increases from 13% for the case of not using air-side economizer to 23% for the case of using air-side economizer.

Occupancy based control, building simulation, adva↗

Establishing a Proficiency Testing Scheme for Drinking Water Radiochemistry

As part of its international water proficiency testing (PT) scheme, 'Aquacheck', the LGC Proficiency Testing Group has established a new water radiochemistry PT scheme. The PT scheme is aimed at laboratories who undertake radiochemical analysis on drinking water samples as part of an environmental monitoring programme. Following a scheme design and feasibility study, the new scheme was established to monitor the laboratory performance of participants undertaking the determination of gross alpha, gross beta and tritium activity. Three rounds of the new water radiochemistry PT scheme are now complete. This paper explains the process of establishing such a scheme, reviews the results so far, and addresses future development of the scheme.

54 ENVIRONMENTAL SCIENCES↗

Probe into Gaseous Pollution and Assessment of Air Quality Benefit under Sector Dependent Emission Control Strategies over Megacities in Yangtze River Delta, China

On February 29th 2012, China published its new National Ambient Air Quality Standard (CH-NAAQS) aiming at revising the standards and measurements for both gaseous pollutants including ozone (O3), nitrogen dioxide (NO2), and sulfur dioxide (SO2), and also particle pollutants including PM10 and PM2.5. In order to understand the air pollution status regarding this new standard, the integrated MM5/CMAQ modeling system was applied over Yangtze River Delta (YRD) within this study to examine the criteria gaseous pollutants listed in the new CH-NAAQS. Sensitivity simulations were also conducted to assess the responses of gaseous pollutants under 8 different sector-dependent emission reduction scenarios in order to evaluate the potential control strategies. 2006 was selected as the simulation year in order to review the air quality condition at the beginning of China’s 11th Five-Year-Plan (FYP, from 2006 to 2010), and also compared with air quality status in 2010 as the end of 11th FYP to probe into the effectiveness of the national emission control efforts. Base case simulation showed distinct seasonal variation for gaseous pollutants: SO2, and NO2 were found to have higher surface concentrations in winter while O3 was found to have higher concentrations in spring and summer than other seasons. According to the analyses focused on 3 megacities within YRD, Shanghai, Nanjing, and Hangzhou, we found different air quality conditions among the cities: NO2 was the primary pollutant that having the largest number of days exceeding the CH-NAAQS daily standard (80 μg/m3) in Shanghai (59 days) and Nanjing (27 days); SO2 was the primary pollutant with maximum number of days exceeding daily air quality standard (150 μg/m3) in Hangzhou (28 days), while O3 exceeding the daily maximum 8-hour standard (160 μg/m3) for relatively fewer days in all the three cities (9 days in Shanghai, 14 days in Nanjing, and 11 days in Hangzhou). Simulation results from predefined potential applicable emission control scenarios suggested significant air quality improvements from emission reduction: 90% of SO2 emission removed from power plant in YRD would be able to reduce more than 85% of SO2 pollution, 85% NOx emission reduction from power plant would reduce more than 60% of NO2 pollution, in terms of reducing the number of days exceeding daily air quality standard. NOx emission reduction from transportation and industry were also found to effectively reduce NO2 pollution but less efficient than emission control from power plants. We also found that multi-pollutants emission control including both NOx and VOC would be a better strategy than independent NOx control over YRD which is China’s 12th Five-Year-Plan (from 2011 to 2015), because O3 pollution would be increased as a side effect of NOx control and counteract NO2 pollution reduction benefit.

Chinese National Air Quality Standard↗

Control of collective network chaos

Under certain conditions, the collective behavior of a large globally-coupled heterogeneous network of coupled oscillators, as quantified by the macroscopic mean field or order parameter, can exhibit low-dimensional chaotic behavior. Recent advances describe how a small set of “reduced” ordinary differential equations can be derived that captures this mean field behavior. Here, we show that chaos control algorithms designed using the reduced equations can be successfully applied to imperfect realizations of the full network. To systematically study the effectiveness of this technique, we measure the quality of control as we relax conditions that are required for the strict accuracy of the reduced equations, and hence, the controller. Although the effects are network-dependent, we show that the method is effective for surprisingly small networks, for modest departures from global coupling, and even with mild inaccuracy in the estimate of network heterogeneity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fault diagnosis and fault tolerant control for T-S fuzzy stochastic distribution systems subject to sensor and actuator faults

The problem of fault diagnosis (FD) and fault tolerant control (FTC) for a class of Takagi-Sugeno (T-S) fuzzy stochastic distribution control (SDC) systems subject to sensor and actuator faults is discussed in this paper. First, fuzzy logic models are used to approximate the output probability density function (PDF). Next, an adaptive augmented state/fault diagnosis observer is proposed to estimate the system state, sensor and the actuator faults simultaneously. New expected weights based on the sensor fault estimation information and a PI-type fuzzy feedback fault tolerant (FT) controller are designed to compensate the effect of sensor fault and actuator fault simultaneously. When the sensor fault occurs, the expected objective is redesigned to compensate the sensor fault. Meanwhile, the PI controller can compensate the effect of actuator fault, and the output PDF of the system can still track the desired PDF after the fault occurs. Finally, an example of quality distribution control in chemical reaction process is given to confirm the effectiveness of the algorithm.

42 ENGINEERING↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new fuel modeling capability, CTFFuel, with a case study on the fuel thermal conductivity degradation

Here, a new fuel modeling capability, CTFFuel, is developed from the subchannel code, CTF. This code is a standalone interface to the CTF fuel rod models, allowing for fuel rod simulations to be run independently from the fluid. This paper provides an overview of the code with a case study on the thermal conductivity degradation of LWR fuels to demonstrate its capabilities. The modeling of fuel thermal conductivity degradation in the code is improved through the addition of new modeling options to account for the irradiation effects via globally defined parameters. After the initial implementation, a variety of order-of-accuracy tests and code comparisons are performed to test software quality. A controlled analysis is allowed by CTFFuel to verify the numerical scheme of CTF’s conduction solution and to benchmark its fuel temperature predictions against FRAPCON-4.0’s. Overall, the software quality and verification procedure ensures that the new model is coded correctly, that it properly interacts with the rest of the code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗