Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Intense cavitation-assisted electric discharge as a promising tool for water treatment

This study investigates interrelations between one-electrode Cavitation-Assisted Electric Discharge (CAED), two-electrode CAED, and recently discovered Intense CAED (I-CAED). The one-electrode CAED is a self-triggered nanosecond discharge with pulse energy in the micro-Joule range, which can be generated even by a DC voltage. I-CAED consists of a non-equilibrium part within a low-pressure cavitating region and a micro-spark traversing a liquid film. We hypothesize that CAED propagates from the high-voltage electrode as an ionization wave through bubbles of saturated vapor. Subsequently, the streamer-like discharges in the bubbles may form a continuous plasma channel. Inside the cavitating region, the plasma is strongly non-equilibrium, providing an ideal environment for generating chemically unstable species such as hydrogen peroxide (H 2 O 2 ). Plasma of I-CAED spark is characterized by high electron density and near-thermal equilibrium, emitting a continuous ultraviolet spectrum. The combination of these different discharge parts makes I-CAED in water a highly effective tool for the Advanced Oxidation Process, particularly in water disinfection. Experimentally demonstrated Electric Energy per Order value for disinfection of E. coli-contaminated water is as low as 0.135 ± 0.035 kWh/m 3 /order. Estimates show that the implementation of “dry electrodes” configuration reduces the erosion rate of the electrode material by at least one order of magnitude. Spectral analysis reveals that the continuum emission generated by I-CAED in proximity to metal electrodes deviates from the spectra of discharges spatially decoupled from the electrodes. We assume that this spectral divergence is attributable to blackbody-like emission originating from metallic nanoparticles form during the electrode's erosion process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase-Dependent Squeezing in Dual-Comb Interferometry

Manipulating the quantum noise of continuous-wave lasers through squeezing has reshaped optical interferometry. However, progress in optical frequency comb interferometry with pulsed squeezed sources has been limited, despite the role of frequency combs in ultraprecise optical metrology. Here, we introduce a new time-domain approach to characterizing squeezed femtosecond light pulses using dual-comb interferometry. Time-domain interferograms are generated via multiheterodyne beating between the modes of a Kerr soliton-squeezed frequency comb and a coherent state comb. The interferogram noise reveals phase-dependent squeezing and antisqueezing, dipping as much as 3.8 ± 0.2 dB below the shot noise level at alternating zero crossings. We model this nonstationary quantum noise as a periodic optical displacement of the squeezed comb by the coherent comb. These results support a route toward quantum-enhanced dual-comb timing applications and high-speed quantum state tomography with dual-comb interferometers.

Herman, Daniel Issac [University of Colorado, Boul↗

Ultrafast electron diffraction: Visualizing dynamic states of matter

Since the discovery of electron-wave duality, electron scattering instrumentation has developed into a powerful array of techniques for revealing the atomic structure of matter. Beyond detecting local lattice variations in equilibrium structures with the highest possible spatial resolution, recent research efforts have been directed toward the long-sought-after dream of visualizing the dynamic evolution of matter in real time. The atomic behavior at ultrafast timescales carries critical information on phase transition and chemical reaction dynamics, the coupling of electronic and nuclear degrees of freedom in materials and molecules, and the correlation among structure, function, and previously hidden metastable or nonequilibrium states of matter. Ultrafast electron pulses play an essential role in this scientific endeavor, and their generation has been facilitated by rapid technical advances in both ultrafast laser and particle accelerator technologies. Here this review presents a summary of the noteworthy developments in this field in the last few decades. The physics and technology of ultrafast electron beams is presented with an emphasis on the figures of merit most relevant for ultrafast electron diffraction experiments. Recent developments in the generation, manipulation, and characterization of ultrashort electron beams aimed at improving the combined spatiotemporal resolution of these measurements are discussed. The fundamentals of electron scattering from atomic matter and the theoretical frameworks for retrieving dynamic structural information from solid-state and gas-phase samples is described. Essential experimental techniques and several landmark works that have applied these approaches are also highlighted to demonstrate the widening applicability of these methods. Ultrafast electron probes with ever-improving capabilities, combined with other complementary photon-based or spectroscopic approaches, hold tremendous potential for revolutionizing our ability to observe and understand energy and matter at atomic scales.

43 PARTICLE ACCELERATORS↗

Emissions in short-gated ns/ps/fs-LIBS for fuel-to-air ratio measurements in methane-air flames

A study of short-gated 10 nanosecond (ns), 100 picosecond (ps), and 100 femtosecond (fs) laser induced breakdown spectroscopy (LIBS) was conducted for fuel-to-air ratio (FAR) measurements in an atmospheric Hencken flame. The intent of the work is to understand which emission lines are available near the optical range in each pulse width regime and which emission ratios may be favorable for generating equivalence ratio calibration curves. The emission spectra in the range of 550–800 nm for ns-LIBS and ps-LIBS are mostly similar with slightly elevated atomic oxygen lines by ps-LIBS. Spectra from fs-LIBS show the lowest continuum background and prominent individual atomic lines, though have significantly weaker ionic emission from nitrogen. A qualitative explanation based on assumed local thermodynamic equilibrium and electron temperatures calculated by the N I I ( 565 n m ) and N I I ( 594 n m ) emissions is presented. In studying line emission ratios for FAR calculation, it is found that H α <#comment/> ( 656 n m ) / N I I ( 568 n m ) is best for FAR measurements with ns-LIBS and remains viable for ps-LIBS, while H α <#comment/> ( 656 n m ) / O I ( 777 n m ) is optimal for the ps-LIBS and fs-LIBS cases. Due to low continuum background and short time delay for spectra collection, fs-LIBS is very promising for high-speed FAR measurements using short-gated LIBS.

Gragston, Mark (ORCID:0000000324698995)↗

Los Alamos Portable Pulser (LAPP) Marx Bank and Digitizer System Characterization

Over the duration of June 22 nd to July 15 th , I interned at Los Alamos National Laboratory within ISR-2 on the Los Alamos Portable Pulser (LAPP) Program. This program concerns a radar dish used for characterizing signal propagation through earth’s ionosphere. The bulk of my internship consisted of characterizing the delay of a Marx Bank Generator and writing hardware-interface C/C++ code for the pulse-recording Digitizer System.

47 OTHER INSTRUMENTATION↗

Research in nonlinear optics

A theoretical investigation revealed that a steady state mode-locked solution appropriate to ultrashort pulses is induced by Kerr liquids. An experimental investigation using a Q-switched ruby laser passively mode-locked by the insertion of a Kerr liquid verified the theory. Pulses of about 10 to the -11th power sec were generated when the relaxation time of the liquid was temperature tuned to approximately 10 to the -11th power sec.

Yariv, A.↗

Electronic transition CN laser

A 20 kW electric-discharge pumped CN laser oscillating on the A(2) Pi-X(2) Sigma molecular system is presented. Excitation is by a simple longitudinal discharge struck through HCN vapor. Twenty kW peak power is generated in a 150 nsec full-width half-maximum pulse. Two lasing bands were observed in the A-X system: the (0,1) and (0,2) bands near 1.42 and 2.0 microns respectively. Both P and Q branches are active in the two bands, with Q bands stronger. Peak laser energy is 3 mJ. Products of UV photolysis of HCN, electron impact excitation of HCN, and other possible excitation mechanisms and laser efficiency are discussed.

Quick, C. R., Jr.↗

Using Spectral Edge To Measure Doppler Shift

New pulsed-laser ranging systems implement spectral-edge technique making high-resolution measurements of Doppler frequency shift in signals backscattered from targets. Pulsed laser emits at ultraviolet, visible, or infrared wavelength suitable for generation of desired target. Optical filter ("edge" filter) has sharp spectral transmission function such that middle frequency of laser emission lies on steep portion of slope ("edge") on one side of peak. Frequency inferred from relative amplitudes of signal with and without filtering. Intended for use in measuring velocities of solid and diffuse moving targets like wind, clouds, aerosols, or rain. Applications include measurements of wind shear from airports and aircraft.

Korb, Lawrence↗

Nonlinear evolution of electromagnetic ion beam instabilities

A comparative study of the ion/ion right-hand resonant instability and the ion/ion nonresonant instability is carried out to investigate and contrast their properties. Linear analysis demonstrates that the nonresonant instability becomes resonant if the density of the ion beam is sufficiently high. Hybrid simulations show that both the resonant and nonresonant instabilities result in the formation of nonlinear pulses, called pulsations, but with distinct features. For example, the pulsations generated by the resonant instability have a positive correlation with the ion density, while those generated by the nonresonant instability are likely to have a relatively weak negative correlation. The waves generated by the nonresonant instability are subject to a parametric decay instability and tend to form a state of condensate where the turbulence becomes nearly monochromatic.

Akimoto, K.↗

Q-Markov covariance equivalent realization and its application to flexible structure identification

The Q-Markov covariance equivalent realization algorithm is applied to NASA's Minimast structure to identify state-space models for the purpose of designing closed-loop controllers, and laboratory test results are shown for the identification and for the closed-loop performance. The paper also presents for the first time a deterministic formulation of covariance parameters from a pulse response, a stochastic formulation of Markov parameters from a white-noise response, and a simple Q-Markov covariance equivalent realization formulation. This requires only pulse laboratory tests or only white-noise laboratory tests to generate Q-Markov covariance equivalent realizations.

Liu, Ketao↗

A digital boxcar integrator for IMS spectra

When trying to detect or quantify a signal at or near the limit of detectability, it is invariably embeded in the noise. This statement is true for nearly all detectors of any physical phenomena and the limit of detectability, hopefully, occurs at very low signal-to-noise levels. This is particularly true of IMS (Ion Mobility Spectrometers) spectra due to the low vapor pressure of several chemical compounds of great interest and the small currents associated with the ionic detection process. Gated Integrators and Boxcar Integrators or Averagers are designed to recover fast, repetitive analog signals. In a typical application, a time 'Gate' or 'Window' is generated, characterized by a set delay from a trigger or gate pulse and a certain width. A Gated Integrator amplifies and integrates the signal that is present during the time the gate is open, ignoring noise and interference that may be present at other times. Boxcar Integration refers to the practice of averaging the output of the Gated Integrator over many sweeps of the detector. Since any signal present during the gate will add linearly, while noise will add in a 'random walk' fashion as the square root of the number of sweeps, averaging N sweeps will improve the 'Signal-to-Noise Ratio' by a factor of the square root of N.

Cohen, Martin J.↗

Measurements of Turbulence Attenuation by a Dilute Dispersion of Solid Particles in Homogeneous Isotropic Turbulence

This research addresses turbulent gas flows laden with fine solid particles at sufficiently large mass loading that strong two-way coupling occurs. By two-way coupling we mean that the particle motion is governed largely by the flow, while the particles affect the gas-phase mean flow and the turbulence properties. Our main interest is in understanding how the particles affect the turbulence. Computational techniques have been developed which can accurately predict flows carrying particles that are much smaller than the smallest scales of turbulence. Also, advanced computational techniques and burgeoning computer resources make it feasible to fully resolve very large particles moving through turbulent flows. However, flows with particle diameters of the same order as the Kolmogorov scale of the turbulence are notoriously difficult to predict. Some simple flows show strong turbulence attenuation with reductions in the turbulent kinetic energy by up to a factor of five. On the other hand, some seemingly similar flows show almost no modification. No model has been proposed that allows prediction of when the strong attenuation will occur. Unfortunately, many technological and natural two-phase flows fall into this regime, so there is a strong need for new physical understanding and modeling capability. Our objective is to study the simplest possible turbulent particle-laden flow, namely homogeneous, isotropic turbulence with a uniform dispersion of monodisperse particles. We chose such a simple flow for two reasons. First, the simplicity allows us to probe the interaction in more detail and offers analytical simplicity in interpreting the results. Secondly, this flow can be addressed by numerical simulation, and many research groups are already working on calculating the flow. Our detailed data can help guide some of these efforts. By using microgravity, we can further simplify the flow to the case of no mean velocity for either the turbulence or the particles. In fact the addition of gravity as a variable parameter may help us to better understand the physics of turbulence attenuation. The experiments are conducted in a turbulence chamber capable of producing stationary or decaying isotropic turbulence with nearly zero mean flow and Taylor microscale Reynolds numbers up to nearly 500. The chamber is a 410 mm cubic box with the corners cut off to make it approximately spherical. Synthetic jet turbulence generators are mounted in each of the eight corners of the box. Each generator consists of a loudspeaker forcing a plenum and producing a pulsed jet through a 20 mm diameter orifice. These synthetic jets are directed into ejector tubes pointing towards the chamber center. The ejector tubes increase the jet mass flow and decrease the velocity. The jets then pass through a turbulence grid. Each of the eight loudspeakers is forced with a random phase and frequency. The resulting turbulence is highly Isotropic and matches typical behavior of grid turbulence. Measurements of both phases are acquired using particle image velocimetry (PIV). The gas is seeded with approximately 1 micron diameter seeding particles while the solid phase is typically 150 micron diameter spherical glass particles. A double-pulsed YAG laser and a Kodak ES-1.0 10-bit PIV camera provide the PIV images. Custom software is used to separate the images into individual images containing either gas-phase tracers or large particles. Modern high-resolution PIV algorithms are then used to calculate the velocity field. A large set of image pairs are acquired for each case, then the results are averaged both spatially and over the ensemble of acquired images. The entire apparatus is mounted in two racks which are carried aboard NASA's KC-135 Flying Microgravity Laboratory. The rack containing the turbulence chamber, the laser head, and the camera floats freely in the airplane cabin (constrained by competent NASA personnel) to minimize g-jitter.

Eaton, John↗

A Secondary Ion Mass Analyzer for Remote Surface Composition Analysis of the Galilean Moons

Galileo in-situ dust measurements have shown that the Galilean moons are surrounded by tenuous dust clouds formed by collisional ejecta from their icy surfaces, kicked up by impacts of interplanetary micrometeoroids. The majority of the ejecta dust particles have been sensed at altitudes below five between 0.5 and 1 micron, just above the detector threshold, indicating a size distribution decreasing towards bigger particles. their parent bodies. They carry information about the properties of the surface from which they have been kicked up. In particular, these grains may carry organic compounds and other chemicals of biological relevance if they exist on the icy Galilean moons. In-situ analysis of the grain composition with a sophisticated dust analyzer instrument flying on a Jupiter Icy Moons Orbiter can provide important information about geochemical and geophysical processes during the evolutionary histories of these moons which are not accessible with other techniques from an orbiter spacecraft. Thus, spacecraft-based in-situ dust measurements can be used as a diagnostic tool for the analysis of the surface composition of the moons. This way, the in-situ measurements turn into a remote sensing technique by using the dust instrument like a telescope for surface investigation. An instrument capable of very high resolution composition analysis of dust particles is the Cometary Secondary Ion Mass Analyzer (COSIMA). The instrument was originally developed for the Comet Rendezvous and Asteroid Flyby (CRAF) mission and has now been built for ESA'S comet orbiter Rosetta. Dust particles are collected on a target and are later located by an optical microscope camera. A pulsed primary indium ion gun partially ionizes the dust grains. The generated secondary ions are accelerated in an electric field and travel through a reflectron-type time-of-flight ion mass spectrometer.

Krueger, H.↗

Laser Synthesis of Supported Catalysts for Carbon Nanotubes

Four methods of laser assisted catalyst generation for carbon nanotube (CNT) synthesis have been tested. These include pulsed laser transfer (PLT), photolytic deposition (PLD), photothermal deposition (PTD) and laser ablation deposition (LABD). Results from each method are compared based on CNT yield, morphology and structure. Under the conditions tested, the PLT was the easiest method to implement, required the least time and also yielded the best pattemation. The photolytic and photothermal methods required organometallics, extended processing time and partial vacuums. The latter two requirements also held for the ablation deposition approach. In addition to control of the substrate position, controlled deposition duration was necessary to achieve an active catalyst layer. Although all methods were tested on both metal and quartz substrates, only the quartz substrates proved to be inactive towards the deposited catalyst particles.

VanderWal, Randall L.↗

Processing and Synthesis of Pre-Biotic Chemicals in Hypervelocity Impacts

Hypervelocity impacts (HVIs) may have played a significant role in establishing the initial organic inventory for pre-biotic chemistry on the Earth and other planetary bodies. In addition to the delivery of organic compounds intact to planetary surfaces, generally at velocities below approx.20 km/s, HVIs also enable synthesis of new molecules. The cooling post-impact plasma plumes of HVIs in the interstellar medium (ISM), the protosolar nebula (PSN), and the early solar system comprise pervasive conditions for organic synthesis. Such plasma synthesis (PS) can operate over many length scales (from nm-scale dust to planets) and energy scales (from molecular rearrangement to atomization and recondensation). HVI experiments with the flexibility to probe the highest velocities and distinguish synthetic routes are a high priority to understand the relevance of PS to exobiology. We describe here recent studies of PS at small spatial scales and extremely high velocities with pulsed laser ablation (PLA). PLA can simulate the extreme plasma conditions generated in impacts of dust particles at speeds of up to 100 km/s or more. When applied to carbonaceous solids, new and pre-biotically relevant molecular species are formed with high efficiency [1,2].

Brickerhoff, W. B.↗

UAVSAR Active Electronically-Scanned Array

The Uninhabited Airborne Vehicle Synthetic Aperture Radar (UAVSAR) L-band (1.2-1.3 GHz) repeat pass, interferometric synthetic aperture radar (InSAR) used for Earth science applications. Using complex radar images collected during separate passes on time scales of hours to years, changes in surface topography can be measured. The repeat-pass InSAR technique requires that the radar look angle be approximately the same on successive passes. Due to variations in aircraft attitude between passes, antenna beam steering is required to replicate the radar look angle. This paper describes an active, electronically steered array (AESA) that provides beam steering capability in the antenna azimuth plane. The array contains 24 transmit/receive modules generating 2800 W of radiated power and is capable of pulse-to-pulse beam steering and polarization agility. Designed for high reliability as well as serviceability, all array electronics are contained in single 178cm x 62cm x 12 cm air-cooled panel suitable for operation up 60,000 ft altitude.

Sadowy, Gregory↗

Precision Synchronization for Free-Space Quantum Networking

Precision synchronization is vital for robust long-distance quantum networking over fiber and free-space channels for which high-fidelity entanglement swapping between separate sources via an optical Bell state measurement requires temporal overlap of photonic qubits arriving from either source. This challenge is particularly distinct in satellite-based entanglement distribution in which relative motion, channel effects, and propagation delay must be addressed. This work presents a precision synchronization method for free space entanglement distribution, and reports on risk reduction testing in a quantum networking testbed at MIT Lincoln Laboratory. Primary consideration is for a dual-uplink architecture in which photons from entanglement sources at two ground locations interact in an optical Bell-state measurement implemented on a satellite in a low-earth orbit. The control approach uses independent entanglement sources at each ground location supplemented with a synchronization signal for feedback control from a timing discriminant measured at the spacecraft. The approach is being implemented in a laboratory testbed using 1-GHz repetition rate 1550-nm band entanglement sources generating ~10-MHz source entanglement rates with few-ps photon pulse lengths. The paper describes both fundamental architectural considerations and practical implementation details.

quantum↗

Radio frequency passband signal generation using photonics

Devices, methods and systems for generating wideband, high-fidelity arbitrary radio frequency (RF) passband signals are described. A voltage tunable optical filter for arbitrary RF passband signal generation includes a first input configured to receive a broadband optical pulse train, a second input configured to receive a first control voltage representative of an amplitude signal, an electrooptic modulator to receive the broadband optical pulse train and the first control voltage, to modulate the broadband optical pulse train in accordance with the amplitude signal, and to produce two complementary optical outputs that form two arms of an interferometer, an optical delay component to impart an optical path difference into one of the complementary outputs of the electrooptic modulator, and a combiner or a splitter to receive two complementary optical outputs of the electrooptic modulator after impartation of the optical path difference and to produce an output interference pattern of fringes.

Gowda, Apurva Shantharaj↗