Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plugs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Unsteady heat transfer in turbine blade ducts: Focus on combustor sources

Thermal waves generated by either turbine rotor blades cutting through nonuniform combustor temperature fields or unsteady burning could lead to thermal fatigue cracking in the blades. To determine the magnitude of the thermal oscillation in blades with complex shapes and material compositions, a finite element Galerkin formulation has been developed to study combustor generated thermal wave propagation in a model two-dimensional duct with a uniform plug flow profile. The reflection and transmission of the thermal waves at the entrance and exit boundaries are determined by coupling the finite element solutions at the entrance and exit to the eigenfunctions of an infinitely long adiabatic duct. Example solutions are presented. In general, thermal wave propagation from an air passage into a metallic blade wall is small and not a problem. However, if a thermal barrier coating is applied to a metallic surface under conditions of a high heat transfer, a good impedance match is obtained and a significant portion of the thermal wave can pass into the blade material.

Baumeister, Kenneth J.↗

Channel size influence on the heat flux density at zero net mass flow in the non-linear transport regime between 1.2 and 2.1 K

Porous media and narrow ducts of simple shape at zero net mass flow (ZNMF) are used to investigate the influence of pore size on the entropy/heat convection rate at ZNMF. The study is relevant to the development of specific types of phase separators. Previous work on heat transport by convection is extended to porous media without mass loss. The experimental results show the influence of pore size on heat flux for permeabilities between 10 to the -8th and 10 to the -6th sq cm. ZNMF plug data are found to be similar to results obtained for vapor liquid phase separation.

Frederking, T. H. K.↗

Performance test of a laboratory pump liquid transfer based on the fountain effect

A laboratory scale pump has been tested in detail in order to determine the flow characteristics of a heater-activated all-metal thermomechanical pump (fountain effect pump, FEP). The emphasis is on the functional dependence of the fountain pressure difference versus mass throughput. A modified Vote et al. (1971) power law approximation is employed for a simplified description of the flow rate as a function of the driving force. Flow rates of up to 10 liters/(hr/sq cm) have been obtained despite a large nominal pore size of the porous plug of 2 microns (filtration rating) used for the FEP.

Chen, W. E. W.↗

Space cryogenics components based on the thermomechanical (TM) effect

He II vapor-liquid phase separation (VLPS) is discussed, with emphasis on fluid-related transport phenomena. The VLPS system has been studied for both linear and nonlinear regimes, demonstrating that well-defined convection patterns exist in porous plug phase separators. In the second part, other components based on the thermomechanical effect are discussed in the limit of ideal conditions. Examples considered include the heat pipe transfer of zero net mass flow, liquid transfer pumps based on the fountain effect, mechanocaloric devices for cooling purposes, and He II vortex refrigerators.

Yuan, S. W. K.↗

Development and calibration of buried wire gages for wall shear stress measurements in fluid flow

Special methods were developed to arrange 'Buried Wire Gage' inserts flush to the contoured flow surfaces of instrument plugs of a boundary-layer flow apparatus. The fabrication process was aimed at producing proper bonding of the sensor wire to the substrate surface, without causing excessive surface waviness. A large number of gages were built and first calibrated for the resistance-temperature characteristics. The gages were then installed in a flow calibration apparatus and operated from a constant temperature anemometer system for a series of flow settings to derive the calibration constants of each of the gages. The flow settings included a range of subsonic freestream Mach numbers in order to help establish the gage calibration characteristics for compressible flow fields. This paper provides a description of the buried wire gage technique, an explanation of the method evolved for making proper gages, the procedure for calibrating the gages and the results of measurements performed for determining the calibration constants.

Murthy, Sreedhara V.↗

Performance test of a laboratory pump for liquid transfer based on the fountain effect

A laboratory scale pump which determines the flow characteristics of a heater-activated all-metal thermomechanical fountain-effect pump (FEP) is evaluated. Results are presented on the functional dependence of the fountain pressure difference versus mass throughput. A modified Vote et al. (1971) power law approximation is used to obtain the flow rate as a function of the driving force. Despite a large nominal pore size of the porous plug used for the FEP, flow rates of up to 10 liter/hr sq cm have been obtained.

Chen, W. E. W.↗

Calibration-Tube Dewar

Container maintains reference material for gas chromatography at constant temperature for extended periods. Developed for holding peroxyacetylnitrate (PAN), material unstable at room temperature but stable at 0 degree C. Keeps vial of PAN at this temperature by immersing in mixture of water and ice. Perforated tube surrounds vial, protects from damage by ice but allows cold water to circulate around. Plug with handle removable so ice added through filler tube. O-rings seal joints around removable parts. Substances undergoing phase changes at other temperatures substituted for ice and water if different reference materials and storage temperatures used. Used on research aircraft collecting and analyzing air samples in troposphere and stratosphere.

Herlth, Donald B.↗

Phase Separators And Fountain-Effect Pumps For He 11

Fused-glass microchannel arrays for use as HE 11 phase separators and fountain-effect pumps. Microchannel devices for use in low-gravity storage and cooling systems containing superfluid helium. Phase separators and pumps take advantage of thermomechanical effect peculiar to He 11 in restricted spaces. By creating thermal gradient in porous plug, direction of flow reversed, turning phase separator into pump. However, addition of heat disadvantage. Thermal gradient created by using Peltier effect to transfer heat across array, removing heat from He 11 supply and overcoming undesirable addition of heat.

Whitehouse, Paul L.↗

Vacuum Head Checks Foam/Substrate Bonds

Electromechanical inspection system quickly gives measurements indicating adhesion, or lack thereof, between rigid polyurethane foam and aluminum substrate. Does not damage inspected article, easy to operate, and used to perform "go/no-go" evaluations or as supplement to conventional destructive pull-plug testing. Applies vacuum to small area of foam panel and measures distance through which foam pulled into vacuum. Probe head applied to specimen and evacuated through hose to controller/monitor unit. Digital voltmeter in unit reads deflection of LVDT probe head.

Lloyd, James F.↗

Compact Apparatus Grows Protein Crystals

Laboratory apparatus provides delicately balanced combination of materials and chemical conditions for growth of protein crystals. Apparatus and technique for growth based on hanging-drop method for crystallization of macromolecules. Includes pair of syringes with ganged plungers. One syringe contains protein solution; other contains precipitating-agent solution. Syringes intrude into cavity lined with porous reservoir material saturated with 1 mL or more of similar precipitating-agent solution. Prior to activation, ends of syringes plugged to prevent transport of water vapor among three solutions.

Bugg, Charles E.↗

Caldron For High-Temperature Alloys

Induction-heated caldron melts high-temperature alloys. Prevents sort of contamination of melts occurring during arc melting in ceramic crucibles. Liquefies 200 grams of solid metal components of alloy like niobium aluminum and makes alloy homogeneous in less than 3 minutes. Plugged sleeve constitutes main body of caldron. Coolant flows through sleeve to prevent it from melting. Mandrel-wound induction coils adjusted to tune source of power. Also serves as mold for casting alloys into such shapes as bars.

Geringer, Henry J.↗

Dual passband dichroic plate for X-band

A need arose in the Deep Space Network for a dichroic plate that would simultaneously pass two desired frequency bands in the X-band region. In addition, the plate must be totally reflective for S-band frequencies. A dielectrically loaded dichroic plate is described that was developed to meet this need. The unique microwave properties that the new dichroic plate had to possess were: (1) insertion losses of less than 0.04 dB for X-band uplink frequencies centered at 7167 MHz and for X-band downlink frequencies centered at about 8425 MHz; (2) insertion losses that met the low loss requirements at 30 deg incidence angle simultaneously for both parallel and perpendicular polarizations; (3) total reflectivity at S-band frequencies; and (4) ability to maintain these electrical characteristics while passing 100 kW of CW power at X-band or while reflecting 100 kW of CW power at S-band. The dual passband dichroic plate is a thick metallic plate having an array of periodic round holes filled with Teflon plugs. Test results on an experimental prototype plate indicate that it is technically possible to design a dielectrically filled dichroic plate that meets all of the technical requirements.

Otoshi, T. Y.↗

Shatter cones: Diagnostic impact signatures

Uniquely fractured target rocks known as shatter cones are associated with more than one half the world's 120 or so presently known impact structures. Shatter cones are a form of tensile rock failure in which a positive conical plug separates from a negative outer cup or mold and delicate ornaments radiating from an apex are preserved on surfaces of both portions. Although distinct, shatter cones are sometimes confused with other striated geologic features such as ventifacts, stylolites, cone-in-cone, slickensides, and artificial blast plumes. Complete cones or solitary cones are rare, occurrences are usually as swarms in thoroughly fractured rock. Shatter cones may form in a zone where an expanding shock wave propagating through a target decays to form an elastic wave. Near this transition zone, the expanding primary wave may strike a pebble or other inhomogeneity whose contrasting transmission properties produce a scattered secondary wave. Interference between primary and secondary scattered waves produce conical stress fields with axes perpendicular to the plane of an advancing shock front. This model supports mechanism capable of producing such shatter cone properties as orientation, apical clasts, lithic dependence, and shock pressure zonation. Although formational mechanics are still poorly understood, shatter cones have become the simplest geologic field criterion for recognizing astroblemes (ancient terrestrial impact structures).

Mchone, J. F.↗

Qualification Motor no. 8 (QM-8), volume 1

All inspection and instrumentation data indicate that the QM-8 static test firing conducted 20 January 1989 was successful. Ambient temperature at T-0 was 28 F. With two flights successfully accomplished, this final test in the redesigned solid rocket motor (RSRM) program certified that the design meets motor performance requirements under extreme cold conditions. This test was a prerequisite to the third flight. The entire test article was cold conditioned at 20 to 25 F for approximately 31 days to assure a maximum propellant mean bulk temperature (PMBT) of 40 F, making it the lowest PMBT in the history of the program. This extreme condition also presented the opportunity to certify critical components at low temperatures. Certification of field joint and igniter heaters, adhesive bondline integrity, flex bearing performance, flight instrumentation performance, RSRM seal performance, and LSC and nozzle plug performance was accomplished. Prior to motor ignition, the field joints were maintained between 75 to 130 F, the igniter-to-case joint was maintained between 75 to 123 F, and the case-to-nozzle joint was maintained between 75 to 120 F. QM-8 was tested with induced side loads to simulate the strut loads experienced during ignition and maximum aerodynamic loading conditions. The ability of the safe and arm device to change position from safe-to-arm and arm-to-safe was certified. Ballistics performance was certified at the lower limits. Values were within specification requirements. Nozzle performance was nominal with typical erosion. The use of Fiberite carbon-cloth phenolic was certified. The water deluge system, CO2 quench, and other test equipment performed as planned during all required test operations.

Garecht, D. M.↗

Technical Evaluation Motor 3 (TEM-3)

A primary objective of the technical evaluation motor program is to recover the case, igniter and nozzle hardware for use on the redesigned solid rocket motor flight program. Two qualification objectives were addressed and met on TEM-3. The Nylok thread locking device of the 1U100269-03 leak check port plug and the 1U52295-04 safe and arm utilizing Krytox grease on the barrier-booster shaft O-rings were both certified. All inspection and instrumentation data indicate that the TEM-3 static test firing conducted 23 May 1989 was successful. The test was conducted at ambient conditions with the exception of the field joints (set point of 121 F, with a minimum of 87 F at the sensors), igniter joint (set point at 122 F with a minimum of 87 F at sensors) and case-to-nozzle joint (set point at 114 F with a minimum of 87 F at sensors). Ballistics performance values were within specification requirements. Nozzle performance was nominal with typical erosion. The nozzle and the case joint temperatures were maintained at the heaters controlling set points while electrical power was supplied. The water and the CO2 quench systems prevented damage to the metal hardware. All other test equipment performed as planned, contributing to a successful motor firing. All indications are that the test was a success, and all expected hardware will be refurbished for the RSRM program.

Garecht, Diane↗

Remote sensing and geologic studies of localized dark mantle deposits on the moon

Localized lunar dark mantle deposits (LDMD) are small, smooth low-albedo units of pyroclastic origin commonly found associated with endogenic source craters. Analysis of near-infrared spectra, multispectral images, and radar data obtained for 25 LDMD has led to the identification of three compositional groups of LDMD. Group 1 deposits are composed predominantly of highlands-rich wall rock but also contain a substantial juvenile component, Group 2 deposits are composed largely of mare plug rock material, while Group 3 deposits are rich in a mixture of olivine and pyroxene. Variations in eruption conditions are interpreted to be largely responsible for the varying mineralogy of these three types of deposits.

Hawke, B. R.↗

Dewar to dewar model for superfluid helium transfer

A model has been developed to predict the flow of He II between a source and a receiving dewar. The model uses a finite difference aproximation to integrate the describing equations. The transfer path may contain porous plugs or mechanical pumps, heater sections, heat leaks, constrictions due to valves, and bends. These line elements may occur in any order and in any quantity. The line elements are easily reconfigured by changing the input data. The input consists of the number of finite element cells, the pressure in each dewar, the heat input to each section and the dimensions of each section. The output is the temperature, pressure, flow rate, velocities and heat flux in each section. An internal reference table provides the properties of He II. The model is programmed for a LOTUS work sheet. It converges rapidly and usually requires 10 to 15 iterations. For most applications an iteration takes 30 s on an AT. The predictions agree well with experimental data.

Snyder, H. A.↗

Slip effects associated with Knudsen transport phenomena in porous media

Porous media used in phase separators and thermomechanical pumps have been the subject of characterization efforts based on the Darcy permeability of laminar continuum flow. The latter is not always observed at low speed, in particular at permeabilities below 10 to the -9th/squared cm. The present experimental and theoretical studies address questions of slip effects associated with long mean free paths of gas flow at room temperature. Data obtained are in good agreement, within data uncertainty, with a simplified asymptotic Knudsen equation proposed for porous plugs on the basis of Knudsen's classical flow equation for long mean free paths.

Frederking, T. H. K.↗