Assessment of four strain energy decomposition methods for phase field fracture models using quasi-static and dynamic benchmark cases

Abstract Strain energy decomposition methods in phase field fracture models separate strain energy that contributes to fracture from that which does not. However, various decomposition methods have been proposed in the literature, and it can be difficult to determine an appropriate method for a given problem. The goal of this work is to facilitate the choice of strain decomposition method by assessing the performance of three existing methods (spectral decomposition of the stress or the strain and deviatoric decomposition of the strain) and one new method (deviatoric decomposition of the stress) with several benchmark problems. In each benchmark problem, we compare the performance of the four methods using both qualitative and quantitative metrics. In the first benchmark, we compare the predicted mechanical behavior of cracked material. We then use four quasi-static benchmark cases: a single edge notched tension test, a single edge notched shear test, a three-point bending test, and a L-shaped panel test. Finally, we use two dynamic benchmark cases: a dynamic tensile fracture test and a dynamic shear fracture test. All four methods perform well in tension, the two spectral methods perform better in compression and with mixed mode (though the stress spectral method performs the best), and all the methods show minor issues in at least one of the shear cases. In general, whether the strain or the stress is decomposed does not have a significant impact on the predicted behavior.

Zhang, Shuaifang↗

The ion-ion correlations in organic ionic plastic crystal

Organic ionic plastic crystals (OIPCs) are emerging as promising electrolyte materials for solid-state batteries. However, despite the fast ionic diffusion, OIPCs exhibit relatively low DC conductivity in solid phases caused by strong ion-ion correlations that suppress charge transport. To understand the origin of this suppression, we performed a study of ion dynamics in the OIPC 1-Ethyl-1-methylpyrrolidinium bis (trifluoromethyl sulfonyl) imide [P 12 ][TFSI] utilizing dielectric spectroscopy, light scattering, and Nuclear Magnetic Resonance diffusometry. Comparison of the results obtained in this study with the published earlier results on an OIPC with a completely different structure (Diethyl(methyl)(isobutyl)phosphonium Hexafluorophosphate [P 1,2,2,4 ][PF 6 ]) revealed strong similarities in ion dynamics in both systems. Unlike DC conductivity, which may drop more than ten times between melted and solid phases, diffusion of anions and cations remains high and does not show strong changes at phase transition. The conductivity spectra in the broad frequency range demonstrate unusual shapes in solid phases with an additional step separating fast local ion motions from suppressed long-range charge diffusion controlling DC conductivity. We suggested that in solid phases, anions and cations can jump only between the specific ion sites defined by the crystalline structure. These constraints lead to strong cation-cation and anion-anion correlations strongly suppressing long-range charge transport.

36 MATERIALS SCIENCE↗

Safety Evaluation of Nitric Acid Reactions with Non-Polysaccharide Organic Materials

The hazards of non-polysaccharide materials in a transuranic (TRU) waste drum exposed to nitric acid (HNO 3 ) and metal nitrate salts have been evaluated, focusing on sorbents and on resins used in ion-exchange chromatography. The range of sorbent materials can be grouped into two general categories: 1) a variety of polyacrylate and polyacrylamide compounds that incorporate polar carbonyl functional groups designed to sorb protic (i.e., acidic) substrates and solutions; 2) hydrocarbon based polymers that include polystyrene, polybutadiene, and polyethylene derivatives, which are designed to sorb non-polar organic substrates and solutions. The ion-exchange resins are constructed of hydrocarbon based polymeric networks equipped with pendant ionizable functional groups designed to reversibly sorb/desorb ionic species that are targeted for separation from a mobile phase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Analysis of lunar samples for carbon compounds.

Description of one approach to the analysis for carbon compounds in lunar materials from the Apollo 11 mission. The sequential scheme followed generally accepted organic geochemical practices, but was unusual in its application to a single sample. The procedures of the scheme were designed to minimize handling of the solids and extracts or hydrolysates. The solid lunar sample was retained in all steps of the sequential analysis in the vessel in which it was originally placed. Centrifugation was used to separate solid and liquid phases after extraction or refluxing. Liquids were recovered from solids by decantation.

Kvenvolden, K. A.↗

The moon as a high temperature condensate.

The accretion during condensation mechanism, if it occurs during the early over-luminous stage of the sun, can explain the differences in composition of the terrestrial planets and the moon. An important factor is the variation of pressure and temperature with distance from the sun, and in the case of the moon and captured satellites of other planets, with distance from the median plane. Current estimates of the temperature and pressure in the solar nebula suggest that condensation will not be complete in the vicinity of the terrestrial planets, and that depending on location, iron, magnesium silicates and the volatiles will be at least partially held in the gaseous phase and subject to separation from the dust by solar wind and magnetic effects associated with the transfer of angular momentum just before the sun joins the Main Sequence. Many of the properties of the moon, including the 'enrichment' in Ca, Al, Ti, U, Th, Ba, Sr and the REE and the 'depletion' in Fe, Rb, K, Na and other volatiles can be understood if the moon represents a high temperature condensate from the solar nebula.

Anderson, D. L.↗

Heart-rate pulse-shift detector

Detector circuit accurately separates and counts phase-shift pulses over wide range of basic pulse-rate frequency, and also provides reasonable representation of full repetitive EKG waveform. Single telemeter implanted in small animal monitors not only body temperature but also animal movement and heart rate.

Anderson, M.↗

Ground vibration testing of complex structures

A method of measuring separately the in-phase and quadrature components of the vibration response, designed by APL, was developed and applied. Both analysis and test results show immediately a much improved definition of mode shapes and frequencies. The approach was further developed. It allows the measurement of damping in the different natural modes, and the determination of the exact shape of the normal modes, i.e., to eliminate the coupling effect due to structural damping. It is also expected to be used in flight flutter testing.

Stahle, C. V.↗

Optimal rendezvous in the neighborhood of a circular orbit

The minimum velocity change rendezvous solutions, when the motion may be linearized about a circular orbit, fall into two separate regions; the phase-for-free region and the general region. Phase-for-free solutions are derived from the optimum transfer solutions, require the same velocity change expenditure, but may not be unique. Analytic solutions are presented in two of the three subregions. An algorithm is presented for determining the unique solutions in the general region. Various sources of initial conditions are discussed and three examples presented.

Jones, J. B.↗

Optimal rendezvous in the neighborhood of a circular orbit

The minimum velocity-change rendezvous solutions, when the motion may be linearized about a circular orbit, fall into two separate regions; the phase-for-free region and the general region. Phase-for-free solutions are derived from the optimum transfer solutions, require the same velocity-change expenditure, but may not be unique. Analytic solutions are presented in two of the three subregions. An algorithm is presented for determining the unique solutions in the general region. Various sources of initial conditions are discussed and three examples are presented.

Jones, J. B.↗

Pieces of the ancient lunar crust - Ages and composition of clasts in consortium breccia 67915

The composition and chronology of clasts representing three minor lithologies in consortium breccia 67915 are discussed. The lithologies studied are: sodic ferrogabbro, pristine troctolitic anorthosite (67915,26), and granulitic troctolitic anorthosite (67915,67). These lithologies were presumed to represent samples of the ancient lunar crust. The pristine troctolitic anorthosite, a typical member of the pristine anorthosite suite, contains little or no trapped liquid consistent with its two-phase mineralogy. The plagioclase separates have Ar-39-Ar-40 plateau ages of 4.10 + or - 0.06 b.y., and a final rise in the age pattern may represent a 'memory' of the earlier evolution. The granulitic troctolitic anorthosite, which has 13 times larger REE abundances, displays a continuous rise of the Ar-40/Ar-39 ratio. The last 25 percent of the Ar-39 release data establish a minimum age of over 3.5 b.y., but the Pu-244/Nd chronology suggests an age of about 4.3 b.y. The sodic ferrogabbro samples, which appear to be members of the Mg-gabbronorite group of pristine rocks, show large Ar losses but indicate plateaus in the low-temperature data, suggesting a metamorphic event more recently than 260 m.y. ago, a time that is consistent with the North Ray impact event 50 m.y. ago.

Marti, K.↗

Status of the Jicamarca radar

The capabilities of the large 50-MHz radar at Jicamarca for mesosphere-stratosphere-troposphere MST observations were discussed in some detail. Hence this description will be quite brief and will concentrate on recent improvements in the facility. The radar is located about 20 km from Lima, Peru. It is well shielded by surrounding mountains, and most of the ground clutter is restricted to ranges of 15 km or less. The antenna consists of 18,432 half-wave dipoles (9216 crossed pairs) covering an area of 290 m by 290 m and divided up into 64 independent modules which can be individually phased and/or used as separate antennas in any way desired. The whole array can be steered about 3 degrees from the on-axis position (the limit is the beam width of the individual modules, which cannot be steered), and any polarization can be arranged. Even with this limited steerability it is straightforward to determine vector wind velocities by pointing segments of the antenna in different directions. The radar can also be used as in interferometer.

Farley, T.↗

High thermal capacity cold plate/hot plate

The results of an analytical study to determine the feasibility of a novel two-phase cold plate/hot plate (CPHP) are presented. A key feature of the CPHP is the use of capillary forces to separate the liquid and vapor phases and distribute the liquid over the evaporating/condensing surface. The liquid phase is held by capillary forces in a reservoir and is carried to the evaporating surface by a wick. The reservoir is replenished at intervals from a valved external liquid supply line. In the hot plate mode, liquid accumulates in the reservoir and is removed by an external condensate line. Performance requirements for the device were capability of handling a power density of 4 watts/sq cm, an outlet quality (percentage of vapor flow to total flow) greater than 90 percent, and operation in a 0-g environment. An analytical model of CPHP operation was developed which concentrated on the liquid and vapor flows. It was found that the liquid carrying capillary grooves of rectangular cross-section gave significantly better predicted performance than V-shaped grooves. Using the analytical model, capillary groove width and length, vapor channel dimensions, and other parameters were selected to meet the performance requirements with a 100-percent margin.

Hwangbo, H.↗

Heat-Pipe Array for Large-Area Cooling

High rates of heat transfer anticipated. Prototype evaporative cold plate gathers waste heat from equipment mounted on it. Plate made by welding together flanges of several sections of heat pipe. Since plate separates liquid and vapor phases at inlet and outlet ports, eliminates complexities and uncertainties of two-phase flow in zero gravity. On earth, inlet valve enables plate to operate at relatively-large height differences with other plates in same system.

Edelstein, F.↗

Radiative magnetized thermal conduction fronts

The evolution of plane-parallel magnetized thermal conduction fronts in the interstellar medium (ISM) was studied. Separating the coronal ISM phase and interstellar clouds, these fronts have been thought to be the site of the intermediate-temperature regions whose presence was inferred from O VI absorption-line studies. The front evolution was followed numerically, starting from the initial discontinuous temperature distribution between the hot and cold medium, and ending in the final cooling stage of the hot medium. It was found that, for the typical ISM pressure of 4000 K/cu cm and the hot medium temperature of 10 to the 6th K, the transition from evaporation to condensation in a nonmagnetized front occurs when the front thickness is 15 pc. This thickness is a factor of 5 smaller than previously estimated. The O VI column densities in both evaporative and condensation stages agree with observations if the initial hot medium temperature Th exceeds 750,000 K. Condensing conduction fronts give better agreement with observed O VI line profiles because of lower gas temperatures.

Borkowski, Kazimierz J.↗

Viscosity and mass transport in nonuniform Keplerian disks

A quantitative formalism for Keplerian particulate disk dynamics having its basis in a heuristic description of viscous transport is presently applied to the case of a ring with optical thickness radial gradient. A steady-state velocity distribution solution directly yields both the radial mass transport and the viscosity. The analytical method employed involves the solution of a novel form of the Krook equation through the separation of the phase-space collisional-products distribution into a symmetrical component and a delta function-approachable remainder. While this model is simplified for the case treated, its general approach may be extended to less artificially restricted cases.

Ojakangas, G. W.↗