Non-Destructive Study of Bulk Crystallinity and Elemental Composition of Natural Gold Single Crystal Samples by Energy-Resolved Neutron Imaging

Energy-resolved neutron imaging enables non-destructive analyses of bulk structure and elemental composition, which can be resolved with high spatial resolution at bright pulsed spallation neutron sources due to recent developments and improvements of neutron counting detectors. This technique, suitable for many applications, is demonstrated here with a specific study of ~5–10mm thick natural gold samples. Through the analysis of neutron absorption resonances the spatial distribution of palladium (with average elemental concentration of ~0.4 atom% and ~5 atom%) is mapped within the gold samples. At the same time, the analysis of coherent neutron scattering in the thermal and cold energy regimes reveals which samples have a single-crystalline bulk structure through the entire sample volume. A spatially resolved analysis is possible because neutron transmission spectra are measured simultaneously on each detector pixel in the epithermal, thermal and cold energy ranges. With a pixel size of 55μm and a detector-area of 512 by 512 pixels, a total of 262,144 neutron transmission spectra are measured concurrently. The results of our experiments indicate that high resolution energy-resolved neutron imaging is a very attractive analytical technique in cases where other conventional nondestructive methods are ineffective due to sample opacity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient Full-Field Vibration Measurements and Operational Modal Analysis Using Neuromorphic Event-Based Imaging

Traditional vibration measurement typically requires physically attached sensors, such as accelerometers and strain gauges. However, these discrete-point sensors provide only low spatial resolution vibration measurements, potentially foregoing valuable structural information such as localized damage. Noncontact optical measurement methods such as laser vibrometers can achieve high spatial resolution vibration measurements but only through time-consuming sequential measurements and are not cost-effective. As an alternative to traditional vibration measurement methods, digital video cameras are relatively low-cost, agile, and offer noncontact, simultaneous high spatial resolution measurements where every pixel on the structure becomes a measurement point. However, regular digital video cameras are frame-based where each pixel simultaneously performs temporally uniform (synchronous) measurements containing large amounts of redundant (background) data, which consumes considerable resources for video data measurement, management, and processing. To alleviate such a challenge, this work explores the use of event-based neuromorphic imagers, specifically silicon retinas, an efficient alternative to traditional frame-based video cameras, to perform full-field vibration measurements and operational modal analysis. By imitating biological vision, each silicon retina pixel independently and asynchronously records only intensity change events that contain structural motion information while excluding redundant (background) information. Such an asynchronous event-based data measurement mechanism allows for structural motion to be captured on the microsecond scale in an extremely data-efficient manner, which could benefit real-time vibration measurement and control applications. This study takes the first step toward these applications by formulating an existing video frame-based full-field operational modal analysis technique in the event-based, asynchronous silicon retina measurement framework. Specifically, local phase-based motion extraction and blind source separation are used to automatically and efficiently extract full-field vibration and dynamics parameters from silicon retina measurements. The developed method is validated by laboratory experiments on a bench-scale cantilever beam.

42 ENGINEERING↗

Performance of the EBIT calorimeter spectrometer

The EBIT calorimeter spectrometer (ECS) is a new high-resolution, broadband x-ray spectrometer that has recently been installed at the Electron Beam Ion Trap Facility (EBIT) at the Lawrence Livermore National Laboratory. The ECS is an entirely new production class spectrometer that replaces the XRS/EBIT spectrometer that has been operating at EBIT since 2000. The ECS utilizes a 32-pixel x-ray calorimeter array from the XRS instrument on the Suzaku x-ray observatory. Eighteen of the pixels are optimized for the 0.1-10 keV band and yield 4.5 eV full width at half maximum energy resolution and 95% quantum efficiency at 6 keV. In addition, the ECS includes 14 detector pixels that are optimized for the high-energy band with a bandpass from 0.5 to over 100 keV with 34 eV resolution and 32% quantum efficiency at 60 keV. The ECS detector array is operated at 50 mK using a five stage cryogenic system that is entirely automated. The instrument takes data continuously for over 65 h with a 2.5 h recycle time. The ECS is a nondispersive, broadband, highly efficient spectrometer that is one of the prime instruments at the EBIT facility. The instrument is used for studies of absolute cross sections, charge exchange recombination, and x-ray emission from nonequilibrium plasmas, among other measurements in our laboratory astrophysics program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of the Crab Pulsar above 25 GeV with the MAGIC Telescope

The 17 m diameter Cherenkov telescope MAGIC, located on the Canary Island of La Palma, has the lowest trigger threshold among operating Cherenkov telescopes; this makes it a very promising tool for the detection of the pulsed gamma-ray ({gamma}-ray) emission from ground. Recently, a new analog summation trigger concept, which allows reducing the threshold even further, has been designed and implemented. The analog signals of patches in the camera, comprising 18 pixels each, are summed up in the analog mode. In order to prevent triggers from photomultiplier (PMT) afterpulses, the individual pixel signals are clipped at a preset amplitude level and then added up. The average FWHM of the time duration of signals induced by cosmic rays is 2.6 ns. This allows one to keep the coincidence time window very small and thus to strongly suppress accidental triggers. In the usual digital trigger designs, the signal should be above a certain threshold from each individual pixel to contribute to the trigger. In the summation trigger all low amplitude signals in a given patch in the camera are summed up and fully contribute to the trigger.The new trigger concept provides a low cost trigger for Cherenkov telescopes and it is very effective and stable. This trigger system for the MAGIC telescope was installed in October 2007 and was successfully used in the detection of the Crab Pulsar above 25 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polymer/carbon nanotube composite patterns via laser induced forward transfer

Direct and high spatial resolution printing of polymer/carbon nanotube (CNT) composite layers has been demonstrated by means of laser induced forward transfer (LIFT). Laser irradiation of composite target materials, such as poly(acrylic acid)/CNT and polyvinylpyrrolidone/CNT, enabled dry deposition of well resolved composite pixels onto glass substrates. The dispersion of the CNT into the deposited composite pixels was investigated by transmission electron microscopy. The LIFT technique was also employed for the accurate deposition of polymer/CNT composite pixels onto aluminum microelectrodes for the fabrication of chemical sensors based on polymer/CNT compounds.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

'Edge illumination' in X-ray Phase Contrast Imaging

In the late '90s, the concept of 'edge illumination' was developed at ELETTRA in Italy as an alternative method to increase the phase sensitivity of an imaging system. The main idea was to be able to reproduce the fine angular selection of 'analyzer' crystals without actually using a crystal, as this would allow employing the method with divergent and polychromatic (i.e. conventional) x-ray sources. It was observed that this could be achieved by illuminating only the edges of the detector pixels, and that the method's sensitivity could be progressively increased by illuminating smaller pixel fractions closer to its physical edge. A few years later the idea was adapted for use with a conventional source by means of two sets of x-ray masks ('coded aperture' masks), which enabled obtaining the same effect for each row (or column) of pixels of an area detector illuminated by a cone beam. This article reviews the method and presents recent examples of application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiometric calibration and SNR calculation of a SWIR imaging telescope

Radiometric calibration of an imaging telescope is usually made using a uniform illumination sphere in a laboratory. In this study, we used the open-sky images taken during bright day conditions to calibrate our telescope. We found a dark signal offset value and a linear response coefficient value for each pixel by using three different algorithms. Then we applied these coefficients to the taken images, and considerably lowered the image non-uniformity. Calibration can be repeated during the operation of telescope with an object that has better uniformity than open-sky. Also SNR (Signal to Noise Ratio) of each pixel was calculated from the open-sky images using the temporal mean and standard deviations. It is found that SNR is greater than 80 for all pixels even at low light levels.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams

Traditional projection x-ray imaging utilizes only the information from the primary photons. Low-angle coherent scatter images can be acquired simultaneous to the primary images and provide additional information. In medical applications scatter imaging can improve x-ray contrast or reduce dose using information that is currently discarded in radiological images to augment the transmitted radiation information. Other applications include non-destructive testing and security. A system at the Canadian Light Source synchrotron was configured which utilizes multiple pencil beams (up to five) to create both primary and coherent scatter projection images, simultaneously. The sample was scanned through the beams using an automated step-and-shoot setup. Pixels were acquired in a hexagonal lattice to maximize packing efficiency. The typical pitch was between 1.0 and 1.6 mm. A Maximum Likelihood-Expectation Maximization-based iterative method was used to disentangle the overlapping information from the flat panel digital x-ray detector. The pixel value of the coherent scatter image was generated by integrating the radial profile (scatter intensity versus scattering angle) over an angular range. Different angular ranges maximize the contrast between different materials of interest. A five-beam primary and scatter image set (which had a pixel beam time of 990 ms and total scan time of 56 min) of a porcine phantom is included. For comparison a single-beam coherent scatter image of the same phantom is included. The muscle-fat contrast was 0.10 {+-} 0.01 and 1.16 {+-} 0.03 for the five-beam primary and scatter images, respectively. The air kerma was measured free in air using aluminum oxide optically stimulated luminescent dosimeters. The total area-averaged air kerma for the scan was measured to be 7.2 {+-} 0.4 cGy although due to difficulties in small-beam dosimetry this number could be inaccurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position sensitive detection of neutrons in high radiation background field

We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e{sup −} radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm{sup 2}) spectroscopic Timepix detector adapted for neutron detection utilizing very thin {sup 10}B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10{sup −4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A disposable x-ray camera based on mass produced complementary metal-oxide-semiconductor sensors and single-board computers

We have integrated mass-produced commercial complementary metal-oxide-semiconductor (CMOS) image sensors and off-the-shelf single-board computers into an x-ray camera platform optimized for acquisition of x-ray spectra and radiographs at energies of 2–6 keV. The CMOS sensor and single-board computer are complemented by custom mounting and interface hardware that can be easily acquired from rapid prototyping services. For single-pixel detection events, i.e., events where the deposited energy from one photon is substantially localized in a single pixel, we establish ∼20% quantum efficiency at 2.6 keV with ∼190 eV resolution and a 100 kHz maximum detection rate. The detector platform’s useful intrinsic energy resolution, 5-μm pixel size, ease of use, and obvious potential for parallelization make it a promising candidate for many applications at synchrotron facilities, in laser-heating plasma physics studies, and in laboratory-based x-ray spectrometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threshold selection for classification of MR brain images by clustering method

Given a grey-intensity image, our method detects the optimal threshold for a suitable binarization of MR brain images. In MR brain image processing, the grey levels of pixels belonging to the object are not substantially different from the grey levels belonging to the background. Threshold optimization is an effective tool to separate objects from the background and further, in classification applications. This paper gives a detailed investigation on the selection of thresholds. Our method does not use the well-known method for binarization. Instead, we perform a simple threshold optimization which, in turn, will allow the best classification of the analyzed images into healthy and multiple sclerosis disease. The dissimilarity (or the distance between classes) has been established using the clustering method based on dendrograms. We tested our method using two classes of images: the first consists of 20 T2-weighted and 20 proton density PD-weighted scans from two healthy subjects and from two patients with multiple sclerosis. For each image and for each threshold, the number of the white pixels (or the area of white objects in binary image) has been determined. These pixel numbers represent the objects in clustering operation. The following optimum threshold values are obtained, T = 80 for PD images and T = 30 for T2w images. Each mentioned threshold separate clearly the clusters that belonging of the studied groups, healthy patient and multiple sclerosis disease.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvement of diffraction efficiency of three-dimensional magneto-optic spatial light modulator with magnetophotonic crystal

We have developed three-dimensional magneto-optic spatial light modulators (3D-MOSLMs) that use magnetic domains as submicron scale pixels to represent holograms. Our display system uses a submicron-scale magnetic pixel array on an amorphous TbFe film to create a wide viewing angle hologram. However, in previous work the reconstructed images had a low intensity and a low optical contrast; brightness of the reconstructed image was 4.4 × 10{sup −2 }cd/m{sup 2} with 532 nm illumination light at 10.8 mW/cm{sup 2}, while display standard ISO13406 recommends 100 cd/m{sup 2} or more. In this paper, we describe our development of a 3D-MOSLM composed of an artificial magnetic lattice structure of magnetophotonic crystals (MPCs). The MPCs enhance the diffraction efficiency of reconstructed 3D images and reduce the power consumption for controlling the magnetic pixels by a light localization effect. We demonstrate reconstructed 3D images using the MPC and show significant brightness improvement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A spatial light modulator that uses scattering in a cholesteric liquid crystal

When a cholesteric liquid crystal (helical pitch: 5 μm) was sandwiched between two glass plates with no alignment coating (gap: 20 μm), a random-domain texture appeared and a strong light scattering took place. This translucent texture turned to a transparent homeotropic phase when an electric voltage of 20 V was applied to the liquid crystal layer. This phase transition was used for constructing a spatial light modulator that needed no polarizers. Indium-tin-oxide electrodes (0.8 mm square) were arranged on a glass substrate to create a 20 × 20 pixel array (20 mm square). The liquid crystal was injected into a gap (20 μm thickness) between this substrate and another glass plate with a uniform electrode (ground). The transmittance of the pixels was originally below 10% and decreased to 0% by 7 V application because of increase in the scattering loss. As the voltage was raised, the transmittance increased gradually in the 7–17 V range and then rapidly in the 17–20 V range, attaining 40% at 27 V. Various transmittance distributions or gray-scale images were attainable by applying a suitable voltage (7–27 V) to each pixel. The transmission range of this spatial light modulator extended from ultraviolet (350 nm) to infrared wavelengths (>800 nm). Owing to this wide transmission range as well as capability of the polarizer-free operation, this spatial light modulator is useful to control a lamp spectrum in spectroscopic measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential beneficial effects of electron-hole plasmas created in silicon sensors by XFEL-like high intensity pulses for detector development

There is a compelling need for a high frame rate imaging detector with a wide dynamic range, from single x-rays/pixel/pulse to >10{sup 6} x-rays/pixel/pulse, that is capable of operating at both x-ray free electron laser (XFEL) and 3rd generation sources with sustained fluxes of > 10{sup 11} x-rays/pixel/s [1, 2, 3]. We propose to meet these requirements with the High Dynamic Range Pixel Array Detector (HDR-PAD) by (a) increasing the speed of charge removal strategies [4], (b) increasing integrator range by implementing adaptive gain [5], and (c) exploiting the extended charge collection times of electron-hole pair plasma clouds that form when a sufficiently large number of x-rays are absorbed in a detector sensor in a short period of time [6]. We have developed a measurement platform similar to the one used in [6] to study the effects of high electron-hole densities in silicon sensors using optical lasers to emulate the conditions found at XFELs. Characterizations of the employed tunable wavelength laser with picosecond pulse duration have shown Gaussian focal spots sizes of 6 ± 1 µm rms over the relevant spectrum and 2 to 3 orders of magnitude increase in available intensity compared to previous measurements presented in [6]. Results from measurements on a typical pixelated silicon diode intended for use with the HDR-PAD (150 µm pixel size, 500 µm thick sensor) are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-energy x-ray detector calibration for T e and impurity density (n Z ) measurements of MCF plasmas

Here, soft x-ray detection with the new "multi-energy" PILATUS3 detector systems holds promise as a magnetically confined fusion (MCF) plasma diagnostic for ITER and beyond. The measured x-ray brightness can be used to determine impurity concentrations, electron temperatures, n 2 e Z eff products, and to probe the electron energy distribution. However, in order to be effective, these detectors which are really large arrays of detectors with photon energy gating capabilities must be precisely calibrated for each pixel. The energy-dependence of the detector response of the multi-energy PILATUS3 system with 100 K pixels has been measured at Dectris Laboratory. X-rays emitted from a tube under high voltage bombard various elements such that they emit x-ray lines from Zr-Lα to Ag-Kα between 1.8 and 22.16 keV. Each pixel on the PILATUS3 can be set to a minimum energy threshold in the range from 1.6 to 25 keV. This feature allows a single detector to be sensitive to a variety of x-ray energies, so that it is possible to sample the energy distribution of the x-ray continuum and line-emission. PILATUS3 can be configured for 1D or 2D imaging of MCF plasmas with typical spatial energy and temporal resolution of 1 cm, 0.6 keV, and 5 ms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 5- μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering

Here, we have developed a charge-coupled device (CCD) with 5 μm × 45 μm pixels on high-resistivity silicon. The fully depleted 200 μm-thick silicon detector is back-illuminated through a 10 nm-thick in situ doped polysilicon window and is thus highly efficient for soft through > 8 keV hard X-rays. The device described here is a 1.5 megapixel CCD with 2496 × 620 pixels. The pixel and camera geometry was optimized for Resonant Inelastic X-ray Scattering (RIXS) and is particularly advantageous for spectrometers with limited arm lengths. In this article, we describe the device architecture, construction and operation, and its performance during tests at the Advance Light Source (ALS) 8.0.1 RIXS beamline. The improved spectroscopic performance, when compared with a current standard commercial camera, is demonstrated with a ~280 eV (C K ) X-ray beam on a graphite sample. Readout noise is typically 3-6 electrons and the point spread function for soft C K X-rays in the 5 μm direction is 4.0 μm ± 0.2 μm. Finally, the measured quantum efficiency of the CCD is greater than 75% in the range from 200 eV to 1 keV.

36 MATERIALS SCIENCE↗

Machine learning to analyze images of shocked materials for precise and accurate measurements

A supervised machine learning algorithm, called locally adaptive discriminant analysis (LADA), has been developed to locate boundaries between identifiable image features that have varying intensities. LADA is an adaptation of image segmentation, which includes techniques that find the positions of image features (classes) using statistical intensity distributions for each class in the image. In order to place a pixel in the proper class, LADA considers the intensity at that pixel and the distribution of intensities in local (nearby) pixels. This paper presents the use of LADA to provide, with statistical uncertainties, the positions and shapes of features within ultrafast images of shock waves. We demonstrate the ability to locate image features including crystals, density changes associated with shock waves, and material jetting caused by shock waves. This algorithm can analyze images that exhibit a wide range of physical phenomena because it does not rely on comparison to a model. LADA enables analysis of images from shock physics with statistical rigor independent of underlying models or simulations.

47 OTHER INSTRUMENTATION↗

Soft X-ray spectroscopy with transition-edge sensors at Stanford Synchrotron Radiation Lightsource beamline 10-1

We present results obtained with a new soft X-ray spectrometer based on transition-edge sensors (TESs) composed of Mo/Cu bilayers coupled to bismuth absorbers. This spectrometer simultaneously provides excellent energy resolution, high detection efficiency, and broadband spectral coverage. The new spectrometer is optimized for incident X-ray energies below 2 keV. Each pixel serves as both a highly sensitive calorimeter and an X-ray absorber with near unity quantum efficiency. We have commissioned this 240-pixel TES spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 10-1 (BL 10-1) and used it to probe the local electronic structure of sample materials with unprecedented sensitivity in the soft X-ray regime. As mounted, the TES spectrometer has a maximum detection solid angle of 2 × 10 –3 sr. The energy resolution of all pixels combined is 1.5 eV full width at half maximum at 500 eV. We describe the performance of the TES spectrometer in terms of its energy resolution and count-rate capability and demonstrate its utility as a high throughput detector for synchrotron-based X-ray spectroscopy. Here, the results from initial X-ray emission spectroscopy and resonant inelastic X-ray scattering experiments obtained with the spectrometer are presented.

47 OTHER INSTRUMENTATION↗