Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗

Acoustic Database for Turbofan Engine Core-Noise Sources: Volume - I

In this program, a database of dynamic temperature and dynamic pressure measurements were acquired inside the core of a TECH977 turbofan engine to support investigations of indirect combustion noise. Dynamic temperature and pressure measurements were recorded for engine gas dynamics up to temperatures of 3100 degrees Fahrenheit and transient responses as high as 1000 hertz. These measurements were made at the entrance of the high pressure turbine (HPT) and at the entrance and exit of the low pressure turbine (LPT). Measurements were made at two circumferential clocking positions. In the combustor and inter-turbine duct (ITD), measurements were made at two axial locations to enable the exploration of time delays. The dynamic temperature measurements were made using dual thin-wire thermocouple probes. The dynamic pressure measurements were made using semi-infinite probes. Prior to the engine test, a series of bench, oven, and combustor rig tests were conducted to characterize the performance of the dual wire temperature probes and to define and characterize the data acquisition systems. A measurement solution for acquiring dynamic temperature and pressure data on the engine was defined. A suite of hardware modifications were designed to incorporate the dynamic temperature and pressure instrumentation into the TECH977 engine. In particular, a probe actuation system was developed to protect the delicate temperature probes during engine startup and transients in order to maximize sensor life. A set of temperature probes was procured and the TECH977 engine was assembled with the suite of new and modified hardware. The engine was tested at four steady state operating speeds, with repeats. Dynamic pressure and temperature data were acquired at each condition for at least one minute. At the two highest power settings, temperature data could not be obtained at the forward probe locations since the mean temperatures exceeded the capability of the probes. The temperature data were processed using software that accounts for the effects of convective and conductive heat transfer. The software was developed under previous NASA sponsored programs. Compensated temperature spectra and compensated time histories corresponding to the dynamic temperature of the gas stream were generated. Auto-spectral and cross-spectral analyses of the data were performed to investigate spectral features, acoustic circumferential mode content, signal coherence, and time delays. The dynamic temperature data exhibit a wideband and fairly flat spectral content. The temperature spectra do not change substantially with operating speed. The pressure spectra in the combustor and ITD exhibit generally similar shapes and amplitudes, making it difficult to identify any features that suggest the presence of indirect combustion noise. Cross-spectral analysis reveal a strong correlation between pressure and temperature fluctuations in the ITD, but little correlation between temperature fluctuations at the entrance of the HPT and pressure fluctuations downstream of it. Temperature fluctuations at the entrance of the low pressure turbine were an order of magnitude smaller than those at the entrance to the high pressure turbine. Time delay analysis of the temperature fluctuations in the combustor was inconclusive, perhaps due to the substantial mixing that occurs between the upstream and downstream locations. Time delay analysis of the temperature fluctuations in the ITD indicate that they convect at the mean flow speed. Analysis of the data did not reveal any convincing indications of the presence of indirect combustion noise. However, this analysis has been preliminary and additional exploration of the data is recommended including the use of more sophisticated signal processing to explore subtle issues that have been revealed but which are not yet fully understood or explained.

Aeroacoustics↗

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

NV centers↗

Experimental verification of propeller noise prediction

Results of experimental measurements of the sound fields of 1/4-scale general aviation propellers are presented and experimental wake surveys and pressure signatures obtained are compared with theoretical predictions. Experiments were performed primarily on a 1C160 propeller model mounted in front of a symmetric body in an anechoic wind tunnel, and measured the thrust and torque produced by propeller at different rotation speeds and tunnel velocities, wakes at three axial distances, and sound pressure at various azimuths and tip speeds with advance ratio or tunnel velocity constant. Aerodynamic calculations of blade loading were performed using airfoil section characteristics and a modified strip analysis procedure. The propeller was then modeled as an array of point sound sources with each point characterized by the force and volume of the corresponding propeller section in order to obtain the acoustic characteristics. Measurements are found to agree with predictions over a wide range of operating conditions, tip speeds and propeller nacelle combinations, without the use of adjustable constants.

Succi, G. P.↗

Blocked impurity band hybrid infrared focal plane arrays for astronomy

High-performance infrared hybrid focal plane arrays using 10- x 50-element Si:As blocked-impurity-band (BIB) detectors (cutoff wavelength = 28 microns) and matching switched MOSFET multiplexers have been developed and characterized for space astronomy. Use of impurity-band-conduction technology provides detectors which are nuclear-radiation-hard and free of the many anomalies associated with conventional silicon photoconductive detectors. Emphasis in the present work is on recent advances in detector material quality which have led to significantly improved detector and hybrid characteristics. Results demonstrating increased quantum efficiency (particularly at short-wavelength infrared), obtained by varying the BIB detector properties (infrared active layer thickness and arsenic doping profile), are summarized. Measured read noise and dark current for different temperatures are reported. The hybrid array performance achieved demonstrates that BIB detectors are well suited for use in astronomical instrumentation.

Reynolds, D. B.↗

Follow-on Low Noise Fan Aerodynamic Study

The focus of the project was to investigate the effects of turbulence models on the prediction of rotor wake structures. The Advanced Ducted Propfan Analysis (ADPAC) code was modified through the incorporation of the Spalart-Allmaras one-equation turbulence model. Suitable test cases were solved numerically using ADPAC employing the Spalart-Allmaras turbulence model and another prediction code for comparison. A near-wall spacing study was also completed to determine the adequate spacing of the first computational cell off the wall. Solutions were also collected using two versions of the algebraic Baldwin-Lomax turbulence model in ADPAC. The effects of the turbulence model on the rotor wake definition was examined by obtaining ADPAC solutions for the Low Noise Fan rotor-only steady-flow case using the standard algebraic Baldwin-Lomax turbulence model, a modified version of the Baldwin-Lomax turbulence model and the one-equation Spalart-Allmaras turbulence model. The results from the three different turbulence modeling techniques were compared with each other and the available experimental data. These results include overall rotor performance, spanwise exit profiles, and contours of axial velocity taken along constant axial locations and along blade-to-blade surfaces. Wake characterizations were also performed on the experimental and ADPAC predicted results including the definition of a wake correlation function. Correlations were evaluated for wake width and wake depth. Similarity profiles of the wake shape were also compared between all numerical solutions and experimental data.

Heidegger, Nathan J.↗

Automating Bayesian inference and design to quantify acoustic particle levitation

Self-propulsion of micro- and nanoparticles powered by ultrasound provides an attractive strategy for the remote manipulation of colloidal matter using biocompatible energy inputs. Quantitative understanding of particle motion and its dependence on size, shape, and composition requires accurate characterization of the acoustic field, which depends sensitively on the experimental setup. Here, we show how automated experiments based on Bayesian inference and design can accurately and efficiently characterize the acoustic field within resonant chambers used to propel acoustic nanomotors. Repeated cycles of observation, inference, and design (OID) are guided by a physical model that describes the rate at which levitating particles approach the nodal plane. Using video microscopy, we observe the relaxation of tracer particles to this plane following the application of the acoustic field. We use sequential Monte Carlo methods to infer model parameters such as the amplitude and frequency of the resonant chamber while accounting for particle-level measurement noise and population-level heterogeneity in the field. Guided by simulated outcomes, we select the optimal design for the next experiment as to maximize the information gain in the relevant parameters. We show how this iterative process serves to discriminate between competing hypotheses and efficiently converges to accurate parameter estimates using only few automated experiments. We discuss the need for model criticism to ensure the validity of the guiding model throughout automated cycles of observation, inference, and design. Furthermore, this work demonstrates how Bayesian methods can learn the parameters of nonlinear, hierarchical models used to describe video microscopy data of active colloids.

42 ENGINEERING↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

A Hankel singular value approach for identification of low level dynamics in flexible structures

The intensity of dynamics in a flexible structure is characterized by its Hankel singular values. Low level dynamics may be caused by generic properties of a structure or by its actuator and sensor configurations. In the latter case, it is shown that the dynamics can significantly be amplified by small perturbations of actuator and/or sensor configurations. In the presented examples, the variations of sensor configuration of 0.05 or less caused an increase of Hankel singular values of order 1000. This approach is useful for model reduction and model order determination in the presence of noise.

Gawronski, W.↗

Multiple-Path-Length Optical Absorbance Cell

An optical absorbance cell that offers a selection of multiple optical path lengths has been developed as part of a portable spectrometric instrument that measures absorption spectra of small samples of water and that costs less than does a conventional, non-portable laboratory spectrometer. The instrument is intended, more specifically, for use in studying colored dissolved organic matter (CDOM) in seawater, especially in coastal regions. Accurate characterization of CDOM is necessary for building bio-optical mathematical models of seawater. The multiple path lengths of the absorption cell afford a wide range of sensitivity needed for measuring the optical absorbances associated with the wide range of concentrations of CDOM observed in nature. The instrument operates in the wavelength range of 370 to 725 nm. The major subsystems of the instrument (see figure) include a color-balanced light source; the absorption cell; a peristaltic pump; a high-precision, low-noise fiber optic spectrometer; and a laptop or other personal computer. A fiber-optic cable transmits light from the source to the absorption cell. Other optical fibers transmit light from the absorption cell to the spectrometer,

Source record↗

Testing and characterization of an IR CBIRD FPA

High performance IR cameras are in great demand for a variety of applications, including defense (e.g. night vision, missile detection) and space (e.g. imaging at IR wavelengths). IR focal plane arrays (FPAs) are an essential component of IR cameras. An FPA is a collection of detectors at the focal plane of an imaging device, where each detector can be thought of a pixel in the image it is detecting. The FPA in this study is based on Complimentary Barrier Infrared Detectors (CBIRDs). The CBIRD FPA was tested by imaging flat black body targets at three different temperatures, 20ºC, 25ºC, and 30ºC, with images captured using SEIR software. The important figures of merit for an IR FPA, Noise Equivalent Difference Temperature (NEDT), Noise Equivalent Irradiance (NEI), detectivity (D*), responsivity, and quantum Efficiency (QE), were extracted from the image data for each individual detector using a MATLAB program, as was the array Modulation Transfer Function MTF. The test results show a mean NEDT of 16.98mK and an MTF of about 0.34 at the Nyquist frequency. Overall, the array performs well in the MWIR range and takes quality IR images.

Das, Tanya↗

Primary Velocity and Orbital Phase Effects on Planetary Detectability from Small Epoch Number Data Sets

Cross-correlation analyses of high-resolution spectroscopic data have recently shown great success in directly detecting planetary signals and enabling the characterization of their atmospheres. One such technique aims to observe a system at multiple epochs and combine the measured planetary radial velocities from each epoch into a measurement of the planetary Keplerian orbital velocity K {sub p}, constituting a direct detection of the planetary signal. Recent work has shown that in few-epoch (∼5) data sets, unintended structure can arise at a high level, obscuring the planetary detection. In this work, we look to simulations to examine whether there are ways to reduce this structured noise in few-epoch data sets by careful planning of observations. The choice of observation date allows observers to select the primary (stellar) velocity through a set systemic velocity and chosen barycentric velocity and the planetary orbital phase so we focus on the effects of these two parameters. We find that epochs taken when the primary velocity is near zero and the stellar lines remain relatively fixed to the telluric rest-frame greatly reduce the level of structured noise and allow for much stronger planetary detections, on average more than twice the significance of detections made with epochs using randomly selected primary velocities. Following these results, we recommend that observers looking to build up high-resolution multi-epoch data sets target nights when their system has a near-zero primary velocity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of the mutual coherence function for a moving source

The acoustic radiation of a randomly fluctuating source in motion is characterized analytically to determine the mutual coherence function (MCF). A far-field relation is derived via a series of invertible transformations, and a higher-dimension Radon transformation is performed to reconstruct the MCF; explicit formulas for computing the MCF from the transformed radiation data are provided. The technique is applied to the cases of an axisymmetric line source of finite extent moving at constant velocity along a line and a spatially incoherent line source. Applications to X-ray tomography and analysis of the noise emitted by a moving jet aircraft are suggested.

Chow, P. L.↗

Transitioning from Stage-III to Stage-IV: Cosmology from galaxy×CMB lensing and shear×CMB lensing (Final Report for Grant SC0021429 "Cosomology with Galaxy and CMB Surveys: Mitigating Systematic Effects Through Combining Datasets")

We examine the cosmological constraining power from two cross-correlation probes between galaxy and cosmic microwave background (CMB) surveys: the cross-correlation of lens galaxy density with CMB lensing convergence $\langle δ_g$$^κ\text{CMB}\rangle$, and source galaxy weak lensing shear with CMB lensing convergence $\langle^{γκ}$$_{\text{CMB}}\rangle$. These two cross-correlation probes provide an independent cross-check of other large-scale structure constraints and are insensitive to galaxy-only or CMB-only systematic effects. In addition, when combined with other large-scale structure probes, the cross-correlations can break degeneracies in cosmological and nuisance parameters, improving both the precision and robustness of the analysis. In this work, we study how the constraining power of $\langle δ_g$$^κ\text{CMB}\rangle + \langle^{γκ}$$_{\text{CMB}}\rangle$ changes from Stage-III (ongoing) to Stage-IV (future) surveys. Given the flexibility in selecting the lens galaxy sample, we also explore systematically the impact on cosmological constraints when we vary the redshift range and magnitude limit of the lens galaxies using mock galaxy catalogs. We find that in our setup, the contribution to cosmological constraints from $\langle δ_g$$^κ\text{CMB}\rangle$ and $\langle^{γκ}$$_{\text{CMB}}\rangle$ are comparable in the Stage-III data sets; but in Stage-IV surveys, the noise in$\langle δ_g$$^κ\text{CMB}\rangle$ becomes subdominant to cosmic variance, preventing $\langle δ_g$$^κ\text{CMB}\rangle$ to further improve the constraints. This implies that to maximize the cosmological constraints from future $\langle δ_g$$^κ\text{CMB}\rangle$ + $\langle^{γκ}$$_{\text{CMB}}\rangle$ analyses, we should focus more on the requirements on$^{γκ}$$_{\text{CMB}}\rangle$ instead of$\langle δ_g$$^κ\text{CMB}\rangle$. Furthermore, the selection of the lens sample should be optimized in terms of our ability to characterize its redshift or galaxy bias instead of its number density.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Measurement Technology at NASA Langley Research Center

Instrumentation systems have always been essential components of world class wind tunnels and laboratories. Langley continues to be on the forefront of the development of advanced systems for aerospace applications. This paper will describe recent advances in selected measurement systems which have had significant impact on aerospace testing. To fully understand the aerodynamics and aerothermodynamics influencing aerospace vehicles, highly accurate and repeatable measurements need to be made of critical phenomena. However, to maintain leadership in a highly competitive world market, productivity enhancement and the development of new capabilities must also be addressed aggressively. The accomplishment of these sometimes conflicting requirements has been the challenge of advanced measurement developers. However, several new technologies have recently matured to the point where they have enabled the achievement of these goals. One of the critical areas where advanced measurement systems are required is flow field velocity measurements. These measurements are required to correctly characterize the flowfield under study, to quantify the aerodynamic performance of test articles and to assess the effect of aerodynamic vehicles on their environment. Advanced measurement systems are also making great strides in obtaining planar measurements of other important thermodynamic quantities, including species concentration, temperature, pressure and the speed of sound. Langley has been on the forefront of applying these technologies to practical wind tunnel environments. New capabilities in Projection Moire Interferometry and Acoustics Array Measurement systems have extended our capabilities into the model deformation, vibration and noise measurement arenas. An overview of the status of these techniques and recent applications in practical environments will be presented in this paper.

Antcliff, Richard R.↗

Software Defined GPS Receiver for International Space Station

JPL is providing a software defined radio (SDR) that will fly on the International Space Station (ISS) as part of the CoNNeCT project under NASA's SCaN program. The SDR consists of several modules including a Baseband Processor Module (BPM) and a GPS Module (GPSM). The BPM executes applications (waveforms) consisting of software components for the embedded SPARC processor and logic for two Virtex II Field Programmable Gate Arrays (FPGAs) that operate on data received from the GPSM. GPS waveforms on the SDR are enabled by an L-Band antenna, low noise amplifier (LNA), and the GPSM that performs quadrature downconversion at L1, L2, and L5. The GPS waveform for the JPL SDR will acquire and track L1 C/A, L2C, and L5 GPS signals from a CoNNeCT platform on ISS, providing the best GPS-based positioning of ISS achieved to date, the first use of multiple frequency GPS on ISS, and potentially the first L5 signal tracking from space. The system will also enable various radiometric investigations on ISS such as local multipath or ISS dynamic behavior characterization. In following the software-defined model, this work will create a highly portable GPS software and firmware package that can be adapted to another platform with the necessary processor and FPGA capability. This paper also describes ISS applications for the JPL CoNNeCT SDR GPS waveform, possibilities for future global navigation satellite system (GNSS) tracking development, and the applicability of the waveform components to other space navigation applications.

software defined radio (SDR)↗

Characterizing the GOES-R (GOES-16) Geostationary Lightning Mapper (GLM) On-Orbit Performance

Two overlapping efforts help to characterize the GLM performance, the Post Launch Test (PLT) phase to validate the predicted pre-launch instrument performance and the Post Launch Product Test (PLPT) phase to validate the lightning detection product used in forecast and warning decision-making. This paper documents the calibration and validation plans and activities for the first 6 months of GLM on-orbit testing and validation commencing with first light on 4 January 2017. The PLT phase addresses image quality, on-orbit calibration, RTEP threshold tuning, image navigation, noise filtering, and solar intrusion assessment, resulting in a GLM calibration parameter file. The PLPT includes four main activities, the Reference Data Comparisons (RDC), Algorithm Testing (AT), Instrument Navigation and Registration Testing (INRT), and Long Term Baseline Testing (LTBT). Field campaigns are also designed to contribute valuable insights into the GLM performance capabilities. The PLPT tests each contribute to the beta, provisional, and fully validated GLM data.

validation↗

Compensator design for stability enhancement with collocated controllers

A continuum model rather than a finite element model is used. The optimal compensator design is formulated as a stochastic regulator problem and is shown to be solvable by the general infinite-dimensional theory developed by the author despite the lack of exponential stabilizability. Infinite-dimensional steady-state Riccati equations characterizing the feedback control gain and the Kalman filter gain operators can be solved explicitly. The associated performance indexes including the mean-square control-effort are calculated in closed form. As a first approximation, the compensator transfer function can be realized as a bank of bandpass filters in parallel centered at the undamped mode frequencies. Numerical calculations for the gain and bandwidths for a typical configuration are presented. The performance of the compensator is evaluated when in fact in the true model there is no actuator noise. The theoretical problem involved is to show that the infinite-dimensional stochastic process is asymptotically stationary. It is possible to calculate the steady-state covariance in closed form and thereby calculate performance indexes of interest explicitly, facilitating the choice of optimal design parameters.

Balakrishnan, A. V.↗