Neutron reflectometry investigations of interfacial structures of Ti/TiN layers deposited by magnetron sputtering

We report that nanolayered metal-ceramic composite systems provide the possibility to produce new materials with exceptional strength, toughness, and radiation resistance not exhibited by their individual constituents. The unusual behaviors are frequently attributed to the high density of internal interfaces. Most layered structures studied to date contain sharp interfaces and the synthesis of more diffuse interfacial structures, where the interface is graded out of the interface plane, has not been deeply explored. Here we show how neutron reflectometry was used to study the structure of magnetron sputter deposited titanium and titanium nitride (Ti/TiN) layers as a function of deposition parameters: temperature, rate of N 2 flow or pressure, electrical bias applied to the sample, and orientation of the ion source relative to the sample. These different deposition and post-processing strategies resulted in profound changes in the structure of the interfacial region between the two components in Ti/TiN x bilayers. Finally, the results show that temperature and low step-wise N 2 flow rates, but not electrical bias, can form graded interfaces in a controlled manner.

36 MATERIALS SCIENCE↗

Performance evaluation of an energy tuning assembly for neutron spectral shaping

An energy tuning assembly (ETA) was designed here to be fielded at the National Ignition Facility (NIF) to modify the characteristic D-T fusion spectrum to include a prompt fission neutron spectral component. The ETA was characterized at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory to measure the shaped spectrum from an incident deuteron breakup neutron source, test the proposed neutron spectroscopy techniques used to inform the flux measurements at NIF, and validate the ability to predict ETA performance using a Monte Carlo Neutral Particle (MCNP) simulation. Activation foils (i.e., Ni, In, Au, Al) were exposed to a collimated 33-MeV deuteron-breakup beam originating from a tantalum breakup target. The source spectrum absent the ETA was characterized using a set of activation foils and the STAYSL unfolding code. Finally, the ETA-modified spectrum was obtained using activation foil unfolding with a χ 2 ν = 0 . 92 . The ETA-modified unfolded spectrum agreed with the MCNP-simulated prediction in the energy range of 0.1–14 MeV, but exhibited disagreements in the 10 eV–100 keV region. This work demonstrates shaping of the NIF neutron spectrum via the ETA to be a viable path forward for tailored neutron beams at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-249: Neutron Model Upgrade for Radiotherapy Patients Monitoring Using a New Online Detector

Purpose: The purpose of this work is to improve the existing methodology to estimate neutron equivalent dose in organs during radiotherapy treatments, based on a Static Random Access Memory neutron detector (SRAMnd) [1]. This is possible thanks to the introduction of a new digital detector with improved characteristics, which is able to measure online the neutron fluence rate in the presence of an intense photon background [2]. Its reduced size, allows the direct estimation of doses in specific points inside an anthropomorphic phantom (NORMA) without using passive detectors as TLD or CR-39. This versatility will allow not only to improve the existing models (generic abdomen and H and N [1]) but to generate more specific ones for any technique. Methods: The new Thermal Neutron Rate Detector (TNRD), based on a diode device sensitized to thermal neutrons, have been inserted in 16 points of the phantom. These points are distributed to infer doses to specific organs. Simultaneous measurements of these devices and a reference one, located in front of the gantry, have been performed for the mentioned generic treatments, in order to improve the existing model. Results: These new devices have shown more precise since they agree better with Monte Carlo simulations. The comparison of the thermal neutron fluence, measured with TNRD, and the existing models, converted from events to fluence, shows an average improvement of (3.90±3.37) % for H and N and (12.61±9.43) % for abdomen, normalized to the maximum value. Conclusion: This work indicates the potential of these new devices for more precise neutron equivalent dose estimation in organs, as a consequence of radiotherapy treatments. The simplicity of the process makes possible to establish more specific models that will provide a better dose estimation. References[1] Phys Med Biol 2012; 57:6167–6191.[2] A new active thermal neutron detector. Radiat. Prot. Dosim. (in press)

60 APPLIED LIFE SCIENCES↗

Determination of neutron irradiation temperatures of SiC using electrical resistivity method

The irradiation temperature of silicon carbide (SiC) was determined post-irradiation by examination of the recovery of the electrical resistivity due to thermal annealing in a rapid heating/cooling optical furnace. High-purity, high-resistivity grade SiC is routinely used as a passive temperature monitor in neutron irradiation studies at the High Flux Isotope Reactor (HFIR), and this paper presents an alternative automated technique for determination of the irradiation temperature the SiC experienced. Neutron collisions with the atoms results in displaced lattice atoms (interstitials) that act as electron donors yielding a significant decrease in electrical resistivity. The irradiation defects become thermodynamically unstable and start to recombine, when annealed above the irradiation temperature, resulting in a recovery of the electrical resistivity. The resistivity is measured at a fixed elevated temperature above ambient, which is below the target irradiation temperature. When the resistivity is plotted as a function of annealing temperatures, a clear increase is observed due to the recovery of irradiation defects. We have demonstrated that this electrical resistivity measurement of SiC is effective to determine irradiation temperature of SiC. In conclusion, energy levels of various defects in SiC were calculated from Arrhenius plots of electrical conductivity versus inverse temperature.

36 MATERIALS SCIENCE↗

The Transport Properties of Quasi–One-Dimensional Ba 3 Co 2 O 6 (CO 3 ) 0.7

We have performed combined elastic neutron diffuse, electrical transport, specific heat, and thermal conductivity measurements on the quasi–one-dimensional Ba 3 Co 2 O 6 (CO 3 ) 0.7 single crystal to characterize its transport properties. A modulated superstructure of polyatomic CO 3 2- is formed, which not only interferes the electronic properties of this compound, but also reduces the thermal conductivity along the c-axis. Furthermore, a large magnetic entropy is observed to be contributed to the heat conduction. Our investigations reveal the influence of both structural and magnetic effects on its transport properties and suggest a theoretical improvement on the thermoelectric materials by building up superlattice with conducting ionic group.

36 MATERIALS SCIENCE↗

Experimental verification of a method to create a variable energy neutron beam from a monoenergetic, isotropic source using neutron elastic scatter and time of flight

An experiment was performed to determine the neutron energy of near-monoergetic deuterium–deu-terium (D–D) neutrons that elastically scatter in a hydrogenous target. The experiment used two liquid scintillators to perform time of flight (TOF) measurements to determine neutron energy, with the start detector also serving as the scatter target. The stop detector was placed 1.0 m away and at scatter angles of π/6, π/4, and π/3 rad, and 1.5 m at a scatter angle of π/4 rad. When discrete 1 ns increments were implemented, the TOF peaks had estimated errors between 21.2 and 3.6% relative to their expected locations. Full widths at half-maximum (FWHM) ranged between 9.6 and 20.9 ns, or approximately 0.56–0.66 MeV. Monte Carlo simulations were also conducted that approximated the experimental setup and had both D–D and deuterium–tritium (DT) neutrons. The simulated results had errors between -17.2 and 0.0% relative to their expected TOF peaks when 1 ns increments were applied. The largest D–D and D–T FWHMs were 26.7 and 13.7 ns, or approximately 0.85 and 4.98 MeV, respectively. These values, however, can be reduced through manipulation of the dimensions of the system components. Lastly, the results encourage further study of the neutron elastic scatter TOF system with particular interest in application to active neutron interrogation to search for conventional explosives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position sensitive detection of neutrons in high radiation background field

We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e{sup −} radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm{sup 2}) spectroscopic Timepix detector adapted for neutron detection utilizing very thin {sup 10}B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10{sup −4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phenomenological Model for Predicting the Energy Resolution of Neutron-Damaged Coaxial HPGe Detectors

The peak energy resolution of germanium detectors deteriorates with increasing neutron fluence. This is due to hole capture at neutron-created defects in the crystal which prevents the full energy of the gamma-ray from being recorded by the detector. A phenomenological model of coaxial HPGe detectors is developed that relies on a single, dimensionless parameter that is related to the probability for immediate trapping of a mobile hole in the damaged crystal. As this trap parameter is independent of detector dimensions and type, the model is useful for predicting energy resolution as a function of neutron fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of calorimetric assay for operational and accountability measurements of pure plutonium metal

Plutonium pure metal products (PMP) are high purity plutonium metal items produced by electrorefining. The plutonium metal is produced as an approximately 3-kg ring. Accountability measurements for the electro-refining runs are typically balance/weight factor (incoming impure metal), chemistry (pure metal rings), and calorimetric assay or neutron counting of the crucibles and other wastes. The PMP items are qualified for their end use by extensive chemical assay. After PMP materials are made they are often sent to the vault for storage before being sent to the casting process, the next step in the production chain. The chemical assay of PMP items often takes a few weeks; however, before the metal items are allowed into the vault they must be measured. Non-destructive assay personnel measure the metals either by multiplicity neutron counting or calorimetric assay, depending on which instrument is available, thus generating comparisons between non-destructive assay and chemical assay. The suite of measurements, calorimetric assay, chemical assay, and neutron mUltiplicity counting is compared for a large group of PMP items.

36 MATERIALS SCIENCE↗

Bulk texture evolution of nanolamellar Zr–Nb composites processed via accumulative roll bonding

We report that it was recently demonstrated that bulk two-phase 50/50 Zr–Nb nanolayered composites with 90 nm individual layers can be fabricated from an initial coarse-layered composite with 1 mm layers via the severe plastic deformation process of accumulative roll bonding. During the deformation, the Zr phase retained its hcp crystal structure and the Zr–Nb interface remained sharp. Here we use a combination of neutron diffraction and dislocation-based polycrystal plasticity constitutive modeling to assess the evolution of texture and deformation mechanisms over a four order-of-magnitude range in layer thickness. The phase textures in the nanocomposite strongly deviate from that of Zr or Nb rolled in monolithic form, becoming highly peaked and intense. The model suggests that texture development in the Nb phase is associated with multiple slip and contributions from both {1 1 2} <1 1 0> slip and {1 1 0} <1 1 0> slip. Lastly, in the Zr phase the model suggests that the texture develops due to a predominance of prismatic and basal slip.

36 MATERIALS SCIENCE↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lipid bilayer thickness determines cholesterol's location in model membranes

Cholesterol is an essential biomolecule of animal cell membranes, and an important precursor for the biosynthesis of certain hormones and vitamins. It is also thought to play a key role in cell signaling processes associated with functional plasma membrane microdomains (domains enriched in cholesterol), commonly referred to as rafts. In all of these diverse biological phenomena, the transverse location of cholesterol in the membrane is almost certainly an important structural feature. Using a combination of neutron scattering and solid-state 2 H NMR, we have determined the location and orientation of cholesterol in phosphatidylcholine (PC) model membranes having fatty acids of different lengths and degrees of unsaturation. The data establish that cholesterol reorients rapidly about the bilayer normal in all the membranes studied, but is tilted and forced to span the bilayer midplane in the very thin bilayers. The possibility that cholesterol lies flat in the middle of bilayers, including those made from PC lipids containing polyunsaturated fatty acids (PUFAs), is ruled out. Finally, these results support the notion that hydrophobic thickness is the primary determinant of cholesterol's location in membranes.

59 BASIC BIOLOGICAL SCIENCES↗

Growth Strategy of a Hybrid Yb3Rh4Sn13/LaRuSn3 Structure Type: Integrating Thermal Analysis, In Situ Diffraction, and Geometric Descriptors

Remeika phases form a versatile family of cage like intermetallics built from transition metal–centered trigonal prisms linked into three dimensional frameworks that generate two characteristic voids: a large [AX₁₂] cuboctahedral cage hosting the rare earth ion and an [XX′₁₂] icosahedral cage accommodating the tetrel atom. In this work, we present a tool driven approach for targeted solid state synthesis of Remeika phases, integrating differential scanning calorimetry, in situ neutron diffraction, and a geometric tolerance factor that quantifies rare earth size compatibility within these polyhedral cages. When combined with arc melting and metallic flux crystal growth, this framework enables prediction, verification, and isolation of specific Remeika phases. Applying this strategy, we obtain single crystals of the predicted pseudo-perovskite Fe based Remeika compound Yb0.9FeGe3.1. More broadly, this perspective highlights how coupling real time structural probes with simple geometric descriptors provides a general pathway for designing synthesis conditions and accessing potentially metastable structure types in complex intermetallic systems.

36 MATERIALS SCIENCE↗

Ambient and High-Temperature Bulk Characterization of Additively Manufactured Ti-6Al-4V Using Neutron Diffraction

Characterization of the bulk microstructure using neutron diffraction has been applied to investigate the phase fractions and textures of α- and β-phases in Ti-6Al-4V fabricated by additive manufacturing. The microstructure of a specimen cut from a fan structure, built by either electron beam melting (EBM) or selective laser melting, indicated that predominantly the build direction and not the fan angle determines the microstructure. In situ heating experiments of specimens from a rod built using EBM provided insight into the lattice strain, phase fraction, and texture evolution, providing a rich picture of the microstructure changes during heat treatment of additively manufactured Ti-6Al-4V. Finally, a remarkably low weight fraction of β-phase at lower temperatures, deviations from thermal expansion behavior attributed to vanadium repartitioning, as well as texture strengthening were observed.

36 MATERIALS SCIENCE↗

Structural distortion and incommensurate noncollinear magnetism in EuAg 4 As 2

Layered pnictide materials have provided a fruitful platform to study various emergent phenomena, including superconductivity, magnetism, charge density waves, etc. In this work, we report the observation of structural distortion and noncollinear magnetism in layered pnictide EuAg 4 As 2 via transport, magnetization, single crystal x-ray, and neutron diffraction data.EuAg 4 As 2 single crystal shows a structural distortion at 120 K, where two sets of superlattice peaks with the propagation vectors of q 1 =±(0, 0.25, 0.5) and q 2 =±(0.25, 0, 1) emerge. Between 9–15 K, the hexagonal Eu 2+ sublattice enters an unpinned incommensurate magnetic state, with magnetic Bragg reflections pictured as circular sectors. Furthermore, below 9 K, it orders in an incommensurate noncollinear antiferromagnetic state with a well-defined propagation wavevector of (0, 0.1, 0.12) and a very rare magnetic structure, which is helical along the c axis and cycloidal along the b axis with a moment of 6.4 μB/Eu 2+ . Furthermore, rich magnetic phases under magnetic fields, large magnetoresistance, and strong coupling between charge carriers and magnetism in EuAg 4 As 2 are revealed.

36 MATERIALS SCIENCE↗

Observation of Thermally Induced Piezomagnetic Switching in Cu 2 OSeO 3 Polymorph Synthesized under High-Pressure

A polymorph of Cu 2 OSeO 3 with the distorted kagome lattice is successfully obtained using the high-pressure synthesis technique (Cu 2 OSeO 3 -HP). The structural analysis using X-ray and neutron powder diffraction suggests that the tetrahedral Cu 2+ clusters [similar to those in Cu 2 OSeO 3 ambient-pressure phase (Cu 2 OSeO 3 -AP)] exist in Cu 2 OSeO 3 -HP but with three symmetry inequivalent sites. No structural change is observed between 1.5 K and the room temperature. The complex magnetic H-T phase diagram is established based on the temperature- and field-dependent magnetization data, indicating two distinct antiferromagnetic phases at low and intermediate temperatures, in addition to the higher-temperature spin-glass-like phase. The low temperature phase is identified by neutron powder diffraction refinements as a canted noncollinear antiferromagnetic order with a weak ferromagnetic component along the b-axis. Size of the refined ordered moment is ≈1.00(4) µ B in Cu 2 OSeO 3 -HP, indicating a large enhancement compared to that of Cu 2 OSeO 3 -AP (≈0.61 µ B ). By applying a uniaxial stress, finite enhancement of weak ferromagnetic component in the noncollinear antiferromagnetic phase in Cu 2 OSeO 3 -HP is observed, which is the clear evidence of the piezomagnetic effect. Interestingly, the sign of the induced magnetization changes on heating from the low-temperature to the intermediate-temperature phases, indicating a novel piezomagnetic switching effect in this compound.

36 MATERIALS SCIENCE↗