Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MUSCLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Beneficial Effects of Metabolic Supression for Adoptation and Survival in Space Environment

NASA in its plans to send humans to distant destination such as Mars faces the health and physiological performance problems caused by microgravity and space radiation. While most of the environmental conditions in spacecraft during flight can be made to mimic terrestrial conditions, microgravity cannot yet be managed. This space environmental factor has a major impact on the body’s biological system forcing alterations, in order to adapt to this new environment. Most space flight and ground-based studies suggest that prolonged exposure to microgravity leads to significant skeletal muscle atrophy, bone loss, and results in suppression of total metabolism. Due to microgravity, unloaded crewmembers lose up to 1.5% of their skeletal mass and 1.8% of bone strength each month during ISS missions. Remarkably many animals, including human-size bears, which are largely inactive during the 6 to 8 months of hibernation, show no loss in bone mass and much less muscle atrophy than would be anticipated over such a prolonged period of physical inactivity. This suggests that while in a suppressed metabolic state animals have unique natural mechanisms to prevent muscle disuse and bone atrophy. The molecular mechanisms underlying these important adaptations are not yet known. Radiation exposure is the second health hazard encountered during spaceflight that can cause radiation sickness, cancer or death. This study provides new evidence that metabolic activity levels play a critical role in radioprotection. Metabolic suppression, as an adaptive response of cells to minimize damage caused by radiation, enables cells to reduce cellular dysfunction and damage, and prolong their survival despite persistent oxidative stress. Thus mechanistic understanding of metabolism offers a means for sustaining astronauts in long-duration missions. The ultimate goals of this study are to demonstrate that induced metabolic suppression in animals and humans will profoundly reduce their sensitivity to the damaging effects of radiation and microgravity as well as other kinds of stresses caused by spaceflight. The beneficial effects of suppressed metabolism induced by different factors such as temperature, nutrition, and medications, will not only mitigate the most detrimental hazards of spaceflight but also radically reduce mission life support requirements and spaceflight logistics.

Galicia, E.↗

Monitoring Biomarkers for Muscular Atrophy Using an Electrochemical Chip for Astronaut Space Health

Skeletal muscle atrophy is a serious health problem for astronauts in long-duration space flight under microgravity conditions. Preventative measures against muscle atrophy require specific exercise and dietary regimens. Preemptive measurements to improve treatment have the potential to streamline these regimens, decreasing their daily footprint and increasing astronaut quality of life. The objective of our proposed project is to (1) develop a fully integrated disposable microelectrode array chip (with the size of a stamp) that can be interfaced with a handheld electronic system for simultaneous detection of the a panel of biomarkers to monitor the progression of skeletal muscle atrophy due to disuse under microgravity in long-duration spaceflights; and (2) use such quantitative information to guide the combined countermeasures of physical exercise and pharmaceuticals (i.e. specific protease inhibitors) so that the intensity, duration and frequency of exercise can be reduced. Note: The presentation includes voice commentary and plays best as a slide show. The voice begins once the presentation starts, and only requires the user to click to the next slide each time. With a run time of ~15 mins.

Biosensor↗

Monitoring Biomarkers for Muscular Atrophy using an Electronic Chip for Astronaut Health

Skeletal muscle atrophy is a serious health problem for astronauts in long-duration space flight under microgravity conditions. Preventative measures against muscle atrophy require specific exercise and dietary regimens. Preemptive measurements to improve treatment have the potential to streamline these regimens, decreasing their daily footprint and increasing astronaut quality of life. The objective of our proposed project is to (1) develop a fully integrated disposable microelectrode array chip (with the size of a stamp) that can be interfaced with a handheld electronic system for simultaneous detection of the a panel of biomarkers to monitor the progression of skeletal muscle atrophy due to disuse under microgravity in long-duration spaceflights; and (2) use such quantitative information to guide the combined countermeasures of physical exercise and pharmaceuticals (i.e. specific protease inhibitors) so that the intensity, duration and frequency of exercise can be reduced.

Biosensing↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive training on one platform without including a treadmill, such as the European Enhanced Exploration Exercise Device (E4D). It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40) who will partake in nominal exercise on the ISS, including running on the treadmill with vibration isolation system 2 (T2), ergometry on the cycle ergometer with vibration isolation and stabilization device (CEVIS), and strength training on the advanced resistive exercise device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. Results: Data collection for this study is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), Results: Eight subjects (2 Active [CEVIS + ARED], 6 Control) have been recruited for this study. Data collection is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight on Astronaut Health and Performance

INTRODUCTION Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis missions to the Moon and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive capabilities on one platform without including a treadmill. The European Enhanced Exploration Exercise Device [E4D] is one such apparatus. It is critical to validate the efficacy of using exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the effectiveness of using nominal ISS exercise devices for an entire mission compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS Crewmembers are assigned to one of three groups: 1) Controls (n ≥ 40), who partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), cycling on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS), and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who exercise on the CEVIS and ARED only (n = 8); and 3) Active Group 2, who perform aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both Active groups are not permitted to perform treadmill exercise for the entirety of their flight. Health and performance markers, including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and after spaceflight. RESULTS Fifteen subjects (4 Active [CEVIS + ARED], 11 Control) have been recruited. Data collection is ongoing. CONCLUSIONS This study will assess the efficacy of using exploration exercise modalities, including removing the treadmill exercise capability or exclusively using the E4D, compared to the nominal ISS exercise regimen across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions. Supported by the NASA Human Research Program and NASA Exploration Capabilities

A N Varanoske↗

MgADP Promotes Myosin Head Movement toward Actin at Low [Ca 2+ ] to Increase Force Production and Ca 2+ -Sensitivity of Contraction in Permeabilized Porcine Myocardial Strips

Myosin cross-bridges dissociate from actin following Mg 2+ -adenosine triphosphate (MgATP) binding. Myosin hydrolyses MgATP into inorganic phosphate (P i ) and Mg 2+ -adenosine diphosphate (ADP), and release of these hydrolysis products drives chemo-mechanical energy transitions within the cross-bridge cycle to power muscle contraction. Some forms of heart disease are associated with metabolic or enzymatic dysregulation of the MgATP-MgADP nucleotide pool, resulting in elevated cytosolic [MgADP] and impaired muscle relaxation. We investigated the mechanical and structural effects of increasing [MgADP] in permeabilized myocardial strips from porcine left ventricle samples. Sarcomere length was set to 2.0 µm at 28 °C, and all solutions contained 3% dextran T-500 to compress myofilament lattice spacing to near-physiological values. Under relaxing low [Ca 2+ ] conditions (pCa 8.0, where pCa = -log 10 [Ca 2+ ]), tension increased as [MgADP] increased from 0-5 mM. Complementary small-angle X-ray diffraction measurements show that the equatorial intensity ratio, I 1,1 /I 1,0 , also increased as [MgADP] increased from 0 to 5 mM, indicating myosin head movement away from the thick-filament backbone towards the thin-filament. Ca 2+ -activated force-pCa measurements show that Ca 2+ -sensitivity of contraction increased with 5 mM MgADP, compared to 0 mM MgADP. These data show that MgADP augments tension at low [Ca 2+ ] and Ca 2+ -sensitivity of contraction, suggesting that MgADP destabilizes the quasi-helically ordered myosin OFF state, thereby shifting the cross-bridge population towards the disordered myosin ON state. Together, these results indicate that MgADP enhances the probability of cross-bridge binding to actin due to enhancement of both thick and thin filament-based activation mechanisms.

60 APPLIED LIFE SCIENCES↗

Orientation and length of mammalian skeletal myocytes in response to a unidirectional stretch

Effects of mechanical forces exerted on mammalian skeletal muscle cells during development were studied using an in vitro model to unidirectionally stretch cultured C2C12 cells grown on silastic membrane. Previous models to date have not studied these responses of the mammalian system specifically. The silastic membrane upon which these cells were grown exhibited linear strain behavior over the range of 3.6-14.6% strain, with a Poisson's ratio of approximately 0.5. To mimic murine in utero long bone growth, cell substrates were stretched at an average strain rate of 2.36%/day for 4 days or 1.77%/day for 6 days with an overall membrane strain of 9.5% and 10.6%, respectively. Both control and stretched fibers stained positively for the contractile protein, alpha-actinin, demonstrating muscle fiber development. An effect of stretch on orientation and length of myofibers was observed. At both strain rates, stretched fibers aligned at a smaller angle relative to the direction of stretch and were significantly longer compared to randomly oriented control fibers. There was no effect of duration of stretch on orientation or length, suggesting the cellular responses are independent of strain rate for the range tested. These results demonstrate that, under conditions simulating mammalian long bone growth, cultured myocytes respond to mechanical forces by lengthening and orienting along the direction of stretch.

Non-NASA Center↗

Interstitial pH, K(+), lactate, and phosphate determined with MSNA during exercise in humans

The purpose of the present study was to use the microdialysis technique to simultaneously measure the interstitial concentrations of several putative stimulators of the exercise pressor reflex during 5 min of intermittent static quadriceps exercise in humans (n = 7). Exercise resulted in approximately a threefold (P < 0.05) increase in muscle sympathetic nerve activity (MSNA) and 13 +/- 3 beats/min (P < 0.05) and 20 +/- 2 mmHg (P < 0.05) increases in heart rate and blood pressure, respectively. During recovery, all reflex responses quickly returned to baseline. Interstitial lactate levels were increased (P < 0.05) from rest (1.1 +/- 0.1 mM) to exercise (1. 6 +/- 0.2 mM) and were further increased (P < 0.05) during recovery (2.0 +/- 0.2 mM). Dialysate phosphate concentrations were 0.55 +/- 0. 04, 0.71 +/- 0.05, and 0.48 +/- 0.03 mM during rest, exercise, and recovery, respectively, and were significantly elevated during exercise. At the onset of exercise, dialysate K(+) levels rose rapidly above resting values (4.2 +/- 0.1 meq/l) and continued to increase during the exercise bout. After 5 min of contractions, dialysate K(+) levels had peaked with an increase (P < 0.05) of 0.6 +/- 0.1 meq/l and subsequently decreased during recovery, not being different from rest after 3 min. In contrast, H(+) concentrations rapidly decreased (P < 0.05) from resting levels (69.4 +/- 3.7 nM) during quadriceps exercise and continued to decrease with a mean decline (P < 0.05) of 16.7 +/- 3.8 nM being achieved after 5 min. During recovery, H(+) concentrations rapidly increased and were not significantly different from baseline after 1 min. This study represents the first time that skeletal muscle interstitial pH, K(+), lactate, and phosphate have been measured in conjunction with MSNA, heart rate, and blood pressure during intermittent static quadriceps exercise in humans. These data suggest that interstitial K(+) and phosphate, but not lactate and H(+), may contribute to the stimulation of the exercise pressor reflex.

Non-NASA Center↗

Contractile function is unaltered in diaphragm from mice lacking calcium release channel isoform 3

Skeletal muscle expresses at least two isoforms of the calcium release channel in the sarcoplasmic reticulum (RyR1 and RyR3). Whereas the function of RyR1 is well defined, the physiological significance of RyR3 is unclear. Some authors have suggested that RyR3 participates in excitation-contraction coupling and that RyR3 may specifically confer resistance to fatigue. To test this hypothesis, we measured contractile function of diaphragm strips from adult RyR3-deficient mice (exon 2-targeted mutation) and their heterozygous and wild-type littermates. In unfatigued diaphragm, there were no differences in isometric contractile properties (twitch characteristics, force-frequency relationships, maximal force) among the three groups. Our fatigue protocol (30 Hz, 0.25 duty cycle, 37 degrees C) depressed force to 25% of the initial force; however, lack of RyR3 did not accelerate the decline in force production. The force-frequency relationship was shifted to higher frequencies and was depressed in fatigued diaphragm; lack of RyR3 did not exaggerate these changes. We therefore provide evidence that RyR3 deficiency does not alter contractile function of adult muscle before, during, or after fatigue.

Non-NASA Center↗

Effect of 17 days of bed rest on peak isometric force and unloaded shortening velocity of human soleus fibers

The purpose of this study was to examine the effect of prolonged bed rest (BR) on the peak isometric force (P0) and unloaded shortening velocity (V0) of single Ca(2+)-activated muscle fibers. Soleus muscle biopsies were obtained from eight adult males before and after 17 days of 6 degrees head-down BR. Chemically permeabilized single fiber segments were mounted between a force transducer and position motor, activated with saturating levels of Ca2+, and subjected to slack length steps. V0 was determined by plotting the time for force redevelopment vs. the slack step distance. Gel electrophoresis revealed that 96% of the pre- and 87% of the post-BR fibers studied expressed only the slow type I myosin heavy chain isoform. Fibers with diameter > 100 microns made up only 14% of this post-BR type I population compared with 33% of the pre-BR type I population. Consequently, the post-BR type I fibers (n = 147) were, on average, 5% smaller in diameter than the pre-BR type I fibers (n = 218) and produced 13% less absolute P0. BR had no overall effect on P0 per fiber cross-sectional area (P0/CSA), even though half of the subjects displayed a decline of 9-12% in P0/CSA after BR. Type I fiber V0 increased by an average of 34% with BR. Although the ratio of myosin light chain 3 to myosin light chain 2 also rose with BR, there was no correlation between this ratio and V0 for either the pre- or post-BR fibers. In separate fibers obtained from the original biopsies, quantitative electron microscopy revealed a 20-24% decrease in thin filament density, with no change in thick filament density. These results raise the possibility that alterations in the geometric relationships between thin and thick filaments may be at least partially responsible for the elevated V0 of the post-BR type I fibers.

STS-78 Shuttle Project↗

Heavy Metal Accumulation in the Intestinal Tapeworm Proteocephalus macrophallus Infecting the Butterfly Peacock Bass (Cichla ocellaris), from Southeastern Brazil

Here we evaluate the potential of heavy metal accumulation of Proteocephalus macrophallus parasitizing the Butterfly Peacock Bass (Cichla ocellaris). A total of 19 fish specimens were collected. From the hosts, samples of intestine, liver, muscle, and parasites were taken. Heavy metal concentrations (Al, As, Ba, Cd, Cr, Fe, Hg, Mg, Mn, Ni, Pb, Ti, and Zn) were obtained using Atomic Absorption Spectrometry. All analyzed elements was found in higher concentrations in the parasites comparing to its host tissues. The bioconcentration factors were higher in the intestine, varying between 5.91 (Ti) to 8.00 (Ba), followed by the muscle, 1.88 (Mg) to 6.39 (Zn), and liver, 1.67 (Al) to 2.02 (Ba). These results show that at the infection site heavy metal concentrations are reduced, since the elements are absorbed directly from the intestinal wall by the parasites. In general, P. macrophallus presents a reasonable capacity of metal accumulation comparing to its hosts.

54 ENVIRONMENTAL SCIENCES↗

Comparison of CT methods for determining graft steatosis in living donor liver transplantation

Purpose: To evaluate and compare the diagnostic performance of non-enhanced computed tomography (NECT) and contrast-enhanced CT (CECT) attenuation indices in the assessment of hepatic steatosis by using biopsy as the reference standard. Materials and methods: This retrospective study was approved by our Institutional Review Board. 55 Potential donors who underwent both NECT and triphasic CECT and core liver biopsy, were included the study. Average attenuation measurements that were obtained from multiple regions in liver, spleen, and psoas muscle on both unenhanced and CECT were used for analysis. Hepatic attenuation measurements were analyzed with and without normalization with the spleen and psoas muscle. Linear regression and receiver operating characteristic (ROC) curve analysis were used to evaluate the statistical association between CT indices and steatosis at histology. Results: Linear regression analysis confirmed the strongest correlation between steatosis and normalized measurements of hepatic attenuation with splenic attenuations on hepatic venous phase of CECT scan (R 0.821; R{sup 2} 0.674 and R 0.816; R{sup 2} 0.665, respectively). The use of ROC curve analysis also demonstrated that normalized measurements of hepatic attenuation with splenic attenuations on hepatic venous phase of CECT showed high diagnostic performance regarding the qualitative distinction of steatosis (AUC values greater than 0.9). Conclusion: Attenuation measurements of liver normalized with spleen on hepatic venous phase may be useful in evaluating steatosis in donor candidates with moderate to severe steatosis who are unacceptable for liver donation. In this manner unnecessary liver biopsy may be avoided in those donor candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oxidized low density lipoprotein increases RANKL level in human vascular cells. Involvement of oxidative stress

Highlights: •Oxidized LDL enhances RANKL level in human smooth muscle cells. •The effect of OxLDL is mediated by the transcription factor NFAT. •UVA, H{sub 2}O{sub 2} and buthionine sulfoximine also increase RANKL level. •All these effects are observed in human fibroblasts and endothelial cells. -- Abstract: Receptor Activator of NFκB Ligand (RANKL) and its decoy receptor osteoprotegerin (OPG) have been shown to play a role not only in bone remodeling but also in inflammation, arterial calcification and atherosclerotic plaque rupture. In human smooth muscle cells, Cu{sup 2+}-oxidized LDL (CuLDL) 10–50 μg/ml increased reactive oxygen species (ROS) and RANKL level in a dose-dependent manner, whereas OPG level was not affected. The lipid extract of CuLDL reproduced the effects of the whole particle. Vivit, an inhibitor of the transcription factor NFAT, reduced the CuLDL-induced increase in RANKL, whereas PKA and NFκB inhibitors were ineffective. LDL oxidized by myeloperoxidase (MPO-LDL), or other pro-oxidant conditions such as ultraviolet A (UVA) irradiation, incubation with H{sub 2}O{sub 2} or with buthionine sulfoximine (BSO), an inhibitor of glutathione synthesis{sub ,} also induced an oxidative stress and enhanced RANKL level. The increase in RANKL in pro-oxidant conditions was also observed in fibroblasts and endothelial cells. Since RANKL is involved in myocardial inflammation, vascular calcification and plaque rupture, this study highlights a new mechanism whereby OxLDL might, by generation of an oxidative stress, exert a deleterious effect on different cell types of the arterial wall.

60 APPLIED LIFE SCIENCES↗

Ginsenoside Rg3 improves cardiac mitochondrial population quality: Mimetic exercise training

Highlights: •Rg3 is an ergogenic aid. •Rg3 improves mitochondrial antioxidant capacity. •Rg3 regulates mitochondria dynamic remodeling. •Rg3 alone matches some the benefits of aerobic exercise. -- Abstract: Emerging evidence indicates exercise training could mediate mitochondrial quality control through the improvement of mitochondrial dynamics. Ginsenoside Rg3 (Rg3), one of the active ingredients in Panax ginseng, is well known in herbal medicine as a tonic and restorative agent. However, the molecular mechanism underlying the beneficial effects of Rg3 has been elusive. In the present study, we compared the effects of Rg3 administration with aerobic exercise on mitochondrial adaptation in cardiac muscle tissue of Sprague–Dawley (SD) rats. Three groups of SD rats were studied: (1) sedentary control, (2) Rg3-treated and (3) aerobic exercise trained. Both aerobic exercise training and Rg3 supplementation enhanced peroxisome proliferator-activated receptor coactivator 1 alpha (PGC-1α) and nuclear factor-E2-related factor 2 (Nrf2) protein levels in cardiac muscle. The activation of PGC-1α led to increased mRNA levels of mitochondrial transcription factor A (Tfam) and nuclear related factor 1(Nrf1), these changes were accompanied by increases in mitochondrial DNA copy number and complex protein levels, while activation of Nrf2 increased levels of phase II detoxifying enzymes, including nicotinamide adenine dinucleotide phosphate:quinone oxidoreductase 1(NQO1), superoxide dismutase (MnSOD) and catalase. Aerobic exercise also enhanced mitochondrial autophagy pathway activity, including increased conversion of LC3-I to LC3-II and greater expression of beclin1 and autophagy-related protein 7 (ATG7), these effects of aerobic exercise are comparable to that of Rg3. These results demonstrate that Rg3 mimics improved cardiac adaptations to exercise by regulating mitochondria dynamic remodeling and enhancing the quantity and quality of mitochondria.

60 APPLIED LIFE SCIENCES↗

Slow and sustained nitric oxide releasing compounds inhibit multipotent vascular stem cell proliferation and differentiation without causing cell death

Highlights: • Multipotent vascular stem cells (MVSCs) proliferate and differentiate. • Nitric oxide inhibits proliferation of MVSCs. • Nitric oxide inhibits MVSC differentiation to mesenchymal-like stem cells (MSCs). • Smooth muscle cells (SMCs) neither de-differentiate nor proliferate. - Abstract: Atherosclerosis is the leading cause of cerebral and myocardial infarction. It is believed that neointimal growth common in the later stages of atherosclerosis is a result of vascular smooth muscle cell (SMC) de-differentiation in response to endothelial injury. However, the claims of the SMC de-differentiation theory have not been substantiated by monitoring the fate of mature SMCs in response to such injuries. A recent study suggests that atherosclerosis is a consequence of multipotent vascular stem cell (MVSC) differentiation. Nitric oxide (NO) is a well-known mediator against atherosclerosis, in part because of its inhibitory effect on SMC proliferation. Using three different NO-donors, we have investigated the effects of NO on MVSC proliferation. Results indicate that NO inhibits MVSC proliferation in a concentration dependent manner. A slow and sustained delivery of NO proved to inhibit proliferation without causing cell death. On the other hand, larger, single-burst NO concentrations, inhibits proliferation, with concurrent significant cell death. Furthermore, our results indicate that endogenously produced NO inhibits MVSC differentiation to mesenchymal-like stem cells (MSCs) and subsequently to SMC as well.

60 APPLIED LIFE SCIENCES↗