Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONOCRYSTALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

RBS-channeling study of radiation damage in Ar{sup +} implanted CuInSe{sub 2} crystals

Chalcopyrite solar cells are reported to have a high tolerance to irradiation by high energy electrons or ions, but the origin of this is not well understood. This work studies the evolution of damage in Ar{sup +}-bombarded CuInSe{sub 2} single crystal using Rutherford backscattering/channeling analysis. Ar{sup +} ions of 30 keV were implanted with doses in the range from 10{sup 12} to 3 × 10{sup 16} cm{sup −2} at room temperature. Implantation was found to create two layers of damage: (1) on the surface, caused by preferential sputtering of Se and Cu atoms; (2) at the layer of implanted Ar, possibly consisting of stacking faults and dislocation loops. The damage in the second layer was estimated to be less than 2% of the theoretical prediction suggesting efficient healing of primary implantation defects.

36 MATERIALS SCIENCE↗

Evaluation of the dosimetric properties of a synthetic single crystal diamond detector in high energy clinical proton beams

Purpose: To investigate the dosimetric properties of a synthetic single crystal diamond Schottky diode for accurate relative dose measurements in large and small field high-energy clinical proton beams.Methods: The dosimetric properties of a synthetic single crystal diamond detector were assessed by comparison with a reference Markus parallel plate ionization chamber, an Exradin A16 microionization chamber, and Exradin T1a ion chamber. The diamond detector was operated at zero bias voltage at all times. Comparative dose distribution measurements were performed by means of Fractional depth dose curves and lateral beam profiles in clinical proton beams of energies 155 and 250 MeV for a 14 cm square cerrobend aperture and 126 MeV for 3, 2, and 1 cm diameter circular brass collimators. ICRU Report No. 78 recommended beam parameters were used to compare fractional depth dose curves and beam profiles obtained using the diamond detector and the reference ionization chamber. Warm-up/stability of the detector response and linearity with dose were evaluated in a 250 MeV proton beam and dose rate dependence was evaluated in a 126 MeV proton beam. Stem effect and the azimuthal angle dependence of the diode response were also evaluated.Results: A maximum deviation in diamond detector signal from the average reading of less than 0.5% was found during the warm-up irradiation procedure. The detector response showed a good linear behavior as a function of dose with observed deviations below 0.5% over a dose range from 50 to 500 cGy. The detector response was dose rate independent, with deviations below 0.5% in the investigated dose rates ranging from 85 to 300 cGy/min. Stem effect and azimuthal angle dependence of the diode signal were within 0.5%. Fractional depth dose curves and lateral beam profiles obtained with the diamond detector were in good agreement with those measured using reference dosimeters.Conclusions: The observed dosimetric properties of the synthetic single crystal diamond detector indicate that its behavior is proton energy independent and dose rate independent in the investigated energy and dose rate range and it is suitable for accurate relative dosimetric measurements in large as well as in small field high energy clinical proton beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-46: Application of a Twin-Detector Method for the Determination of the Mean Photon Energy Em at Points of Measurement in a Water Phantom Surrounding a GammaMed HDR 192Ir Brachytherapy Source

Purpose: In a brachytherapy photon field in water the fluence-averaged mean photon energy Em at the point of measurement correlates with the radiation quality correction factor kQ of a non water-equivalent detector. To support the experimental assessment of Em, we show that the normalized signal ratio NSR of a pair of radiation detectors, an unshielded silicon diode and a diamond detector can serve to measure quantity Em in a water phantom at a Ir-192 unit. Methods: Photon fluence spectra were computed in EGSnrc based on a detailed model of the GammaMed source. Factor kQ was calculated as the ratio of the detector's spectrum-weighted responses under calibration conditions at a 60Co unit and under brachytherapy conditions at various radial distances from the source. The NSR was investigated for a pair of a p-type unshielded silicon diode 60012 and a synthetic single crystal diamond detector 60019 (both PTW Freiburg). Each detector was positioned according to its effective point of measurement, with its axis facing the source. Lateral signal profiles were scanned under complete scatter conditions, and the NSR was determined as the quotient of the signal ratio under application conditions x and that at position r-ref = 1 cm. Results: The radiation quality correction factor kQ shows a close correlation with the mean photon energy Em. The NSR of the diode/diamond pair changes by a factor of two from 0–18 cm from the source, while Em drops from 350 to 150 keV. Theoretical and measured NSR profiles agree by ± 2 % for points within 5 cm from the source. Conclusion: In the presence of the close correlation between radiation quality correction factor kQ and photon mean energy Em, the NSR provides a practical means of assessing Em under clinical conditions. Precise detector positioning is the major challenge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-390: Characterization of the PTW Synthetic Diamond Detector for Radiation Therapy Measurements

Purpose: To investigate the dosimetric properties of new commercially available synthetic single crystal diamond detector under irradiation with therapeutic photon beams from linear accelerators. Methods: A single crystal diamond detector was tested using 6MV photon beam. The detector performance was evaluated for reproducibility, linearity with dose, dose rate dependence, angular dependence, collection efficiency, and measurement of output factors. Lateral field profiles, and percentage depth dose profiles were measured and compared against commercially available detectors. Results: Reproducibility of the detector measurement has a standard deviation of 0.1%. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below ±0.03% in the dose range from 0.1 to 5Gy. In addition, the detector response is dose rate independent, with deviations below 0.1% in the investigated dose rate range from 1 to 10Gy per min. Charge collection efficiency deviations were within 0.07% from 1 to 10Gy. No angular dependence along the radial direction while up to 1.3% angular dependence was observed in the axial direction. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. Conclusions: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical photon beam dosimetry. The agreement with reference dosimeters show that the detector is suitable for measurements for large fields as well as small fields as the ones used for stereotactic radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-BRE-02: Characterization of a New Commercial Single Crystal Diamond Detector in Photon, Electron and Proton Beams

Purpose: Diamond detectors even with superior characteristics have become obsolete due to poor design, selection of crystal and cost. Recently, microDiamond using synthetic single crystal diamond detector (SCDD) is commercially available which is characterized in various radiation beams in this study. Methods: The characteristics of a commercial SCDD model 60019 (PTW) to a 6- and 15-MV photon beams, 6- and 20-MeV electron beams, and 208 MeV proton beams were investigated and compared to the pre-characterized detectors: TN31010 (0.125 cm{sup 3}) and TN30006 (pinpoint) ionization chambers (PTW), EDGE detector (Sun Nuclear Corp), and SFD Stereotactic Dosimetry Diode Detector (IBA). The depth-dose and profiles data were collected for various field sizes and depths. The dose linearity and dose rate dependency were also evaluated. To evaluate the effects of the preirradiation, the diamond detector which had not been irradiated on the day was set up in the water tank and the response to 100 MU was measured every 20 s. The temperature dependency was tested for the range of 4–60 °C. Angular dependency was evaluated in water phantom by rotating the SCDD. Results: For all radiation types and field sizes, the depth-dose data of the diamond chamber showed identical curve to those of ionization chambers. The profile of the diamond detector was very similar to those of the Edge and SFD detectors, although the 0.125 cm{sup 3} and pinpoint chambers showed averaging effects in the penumbrae region. The temperature dependency was within 0.7% in the range of 4–41°C. A dose of 900 cGy and 1200 cGy were needed to stabilize the chamber to the level within 0.5% and 0.2%, respectively. Conclusion: The type 60019 SCDD detector showed suitable characteristics for depth-dose and profile measurements for wide range of field sizes. However, at least 1000 cGy of pre-irradiation is needed for accurate measurements.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-19A-06: Measurements with a New Commercial Synthetic Single Crystal Diamond Detector

Purpose: A commercial version of a synthetic single crystal diamond detector in a Scottky diode configuration was recently released as the new type 60019 microDiamond detector (PTW-Freiburg). In this study we investigate the dosimetric properties of this detector and explore if the use of the microDiamond detector can be expanded to high energy photon beams of up to 15MV and to large field measurements. Methods: Energy dependency was investigated. Photon and electron depth-dose curves were measured. Photon PDDs were measured with the Semiflex type 31010, microLion type 31018, P-Diode type 60016, SRS Diode type 60018, and the microDiamond type 60019 detector. Electron depth-dose curves were measured with a Markus chamber type 23343, an E Diode type 60017 and the microDiamond type 60019 detector (all PTW-Freiburg). Profiles were measured with the E-Diode and microDiamond at dose maximum depths. Results: The microDiamond detector shows no energy dependence in high energy photon or electron dosimetry. Electron PDD measurements with the E-Diode and microDiamond are in good agreement except for the bremsstrahlungs region, where values are about 0.5 % lower with the microDiamond detector. Markus detector measurements agree with E-Diode measurements in this region. For depths larger than dmax, depth-dose curves of photon beams measured with the microDiamond detector are in close agreement to those measured with the microLion detector for small fields and with those measured with a Semiflex 0.125cc ionization chamber for large fields. For profile measurements, microDiamond detector measurements agree well with microLion and P-Diode measurements in the high-dose region and the penumbra region. For areas outside the open field, P-Diode measurements are about 0.5–1.0% higher than microDiamond and microLion measurements. Conclusion: The investigated diamond detector is suitable for a wide range of applications in high energy photon and electron dosimetry and is interesting for relative as well as absolute dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel synthetic single crystal diamond device for in vivo dosimetry

Purpose: Aim of the present work is to evaluate the synthetic single crystal diamond Schottky photodiode developed at the laboratories of “Tor Vergata” University in Rome in a new dosimeter configuration specifically designed for offline wireless in vivo dosimetry (IVD) applications. Methods: The new diamond based dosimeter, single crystal diamond detector (SCDD-iv), consists of a small unwired detector and a small external reading unit that can be connected to commercial electrometers for getting the detector readout after irradiation. Two nominally identical SCDD-iv dosimeter prototypes were fabricated and tested. A basic dosimetric characterization of detector performances relevant for IVD application was performed under irradiation with {sup 60}Co and 6 MV photon beams. Preirradiation procedure, response stability, short and long term reproducibility, leakage charge, fading effect, linearity with dose, dose rate dependence, temperature dependence, and angular response were investigated. Results: The SCDD-iv is simple, with no cables linked to the patient and the readout is immediate. The range of response with dose has been tested from 1 up to 12 Gy; the reading is independent of the accumulated dose and dose rate independent in the range between about 0.5 and 5 Gy/min; its temperature dependence is within 0.5% between 25 and 38 °C, and its directional dependence is within 2% from 0° to 90°. The combined relative standard uncertainty of absorbed dose to water measurements is estimated lower than the tolerance and action level of 5%. Conclusions: The reported results indicate the proposed novel offline dosimeter based on a synthetic single crystal diamond Schottky photodiode as a promising candidate for in vivo dosimetry applications with photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system

Purpose: To evaluate the new commercial PTW-60019 synthetic single-crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW-60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW-60019 measurements. Measured DORs were compared to the new output factor reference values for Gamma Knife Perfexion (0.814 and 0.900 for 4 and 8 mm, respectively). Profiles in the three directions were also measured for the 4 mm beam to evaluate full width at half maximum (FWHM) and penumbra and to compare them with the corresponding Leksell GammaPlan profiles. Results: FWHM and penumbra for PTW-60019 differed from the calculated values by less than 0.2 and 0.3 mm, for the parallel and transversal acquisitions, respectively. GafChromic films showed FWHM and penumbra within 0.1 mm. The output ratio obtained with the PTW-60019 for the 4 mm field was 1.6% greater in transverse direction compared to the nominal value. Comparable differences up to 0.8% and 1.0% for, respectively, GafChromic films and SFD were found. Conclusions: The microDiamond PTW-60019 is a suitable detector for commissioning and routine use of Gamma Knife with good agreement of both DORs and profiles in the three directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields

Purpose: Modern radiotherapy modalities often use small or nonstandard fields to ensure highly localized and precise dose delivery, challenging conventional clinical dosimetry protocols. The emergence of preclinical spatially fractionated synchrotron radiotherapies with high dose-rate, sub-millimetric parallel kilovoltage x-ray beams, has pushed clinical dosimetry to its limit. A commercially available synthetic single crystal diamond detector designed for small field dosimetry has been characterized to assess its potential as a dosimeter for synchrotron microbeam and minibeam radiotherapy. Methods: Experiments were carried out using a synthetic diamond detector on the imaging and medical beamline (IMBL) at the Australian Synchrotron. The energy dependence of the detector was characterized by cross-referencing with a calibrated ionization chamber in monoenergetic beams in the energy range 30–120 keV. The dose-rate dependence was measured in the range 1–700 Gy/s. Dosimetric quantities were measured in filtered white beams, with a weighted mean energy of 95 keV, in broadbeam and spatially fractionated geometries, and compared to reference dosimeters. Results: The detector exhibits an energy dependence; however, beam quality correction factors (k{sub Q}) have been measured for energies in the range 30–120 keV. The k{sub Q} factor for the weighted mean energy of the IMBL radiotherapy spectrum, 95 keV, is 1.05 ± 0.09. The detector response is independent of dose-rate in the range 1–700 Gy/s. The percentage depth dose curves measured by the diamond detector were compared to ionization chambers and agreed to within 2%. Profile measurements of microbeam and minibeam arrays were performed. The beams are well resolved and the full width at halfmaximum agrees with the nominal width of the beams. The peak to valley dose ratio (PVDR) calculated from the profiles at various depths in water agrees within experimental error with PVDR calculations from Gafchromic film data. Conclusions: The synthetic diamond detector is now well characterized and will be used to develop an experimental dosimetry protocol for spatially fractionated synchrotron radiotherapy.

60 APPLIED LIFE SCIENCES↗

Mechanism of AC charge transport in TlSb{sub 1–x}Ga{sub x}S{sub 2} (x = 0 and 0.03)

The dielectric properties and ac electrical conductivity of TlSb{sub 1–x}Ga{sub x}S{sub 2} (x = 0, 0.03) single-crystals have been measured in the frequency range 5 × 10{sup 4} to 3.5 × 10{sup 7} Hz. Experimental data on the frequency dispersion of the dielectric coefficients and electrical conductivity of the TlSb{sub 1–x}Ga{sub x}S{sub 2} (x = 0, 0.03) single crystals have allowed us to identify the nature of the dielectric loss and the mechanism of charge transport and evaluate parameters of localized states in the band gap. The incorporation of gallium atoms into the crystal lattice of TlSbS{sub 2} crystals has been shown to lead to an increase in the Fermi-level density of states and mean hop time and distance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Morphology, structure, and mechanical properties of the surface of PbTe crystals after etching with H{sub 2}O{sub 2}–HBr–ethylene glycol solutions

The morphology and microstructure of PbTe surfaces polished with H{sub 2}O{sub 2}–HBr–ethylene glycol solutions have been studied by atomic force and electron microscopy techniques. The surface of PbTe single crystals after chemical–mechanical and dynamic chemical polishing with bromine-releasing etchants has been examined by optical microscopy and profilometry. The structural perfection and composition of the PbTe surface after chemical treatment have been determined by X-ray diffraction, scanning electron microscopy, and Raman spectroscopy. The mechanical properties of the crystals have been studied using microindentation. Using X-ray microanalysis, we have monitored the concentrations of the host elements (Pb and Te) and possible contamination with chemical compounds present in the etchants and the solutions used to rinse the samples.

36 MATERIALS SCIENCE↗

Structure and Properties of Boron-Doped LiNbO{sub 3} Single Crystals

We have studied the macro-and microstructure and properties of LiNbO{sub 3}〈B〉 crystals in comparison with LiNbO{sub 3}〈Zn〉 and stoichiometric and congruent lithium niobate crystals. The optical characteristics of the LiNbO{sub 3}〈B〉 crystals have been shown to approach those of the stoichiometric LiNbO{sub 3} and LiNbO{sub 3}〈Zn〉 crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Conductivity of Tetragonal Cadmium Diphosphide Crystals

Tetragonal cadmium diphosphide (β-CdP{sub 2}) single crystals with high structural perfection have been grown and their thermal conductivity has been measured. The results indicate that the higher thermal conductivity across the c axis corresponds to the smaller unit-cell parameter of the crystals (a = 5.08 ± 0.01 Å and c = 18.59 ± 0.05 Å). The observed thermal conductivity anisotropy is tentatively attributed to the fact that structural basis of β-CdP{sub 2} is made up of spectral phosphorus chains running in the [100] and [010] directions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Proton Conductivity and Thermal Properties of Ba(H{sub 2}PO{sub 4}){sub 2}

We have grown single crystals of barium dihydrogen phosphate and studied its thermal transformations during heating to 500°C and its electrotransport properties. Ba(H{sub 2}PO{sub 4}){sub 2} (Pccn) has been shown to undergo no phase transitions up to its dehydration temperature. The thermal decomposition of Ba(H{sub 2}PO{sub 4}){sub 2}, accompanied by dehydration, involves two steps, with maximum rates at ~265 and 370°C, and results in the formation of barium dihydrogen pyrophosphate and barium metaphosphate, respectively. The total enthalpy of the endothermic dehydration events is–244.6 J/g. Using impedance spectroscopy, we have studied in detail the proton conductivity of polycrystalline and single-crystal Ba(H{sub 2}PO{sub 4}){sub 2} samples in a controlled atmosphere. Adsorbed water has been shown to have a significant effect on the proton conductivity of Ba(H{sub 2}PO{sub 4}){sub 2} up to 130°C. The proton conductivity of the Ba(H{sub 2}PO{sub 4}){sub 2} single crystals has been shown to be anisotropic. The conductivity anisotropy correlates with specific structural features of the salt. Higher conductivity values, 3 × 10{sup –9} to 2 × 10{sup –7} S/cm in the range 60–160°C, have been observed in the [100] crystallographic direction, exceeding the conductivity along [010] by an order of magnitude. The activation energy for proton conduction is 0.80 eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photoelectric Fields and Band Gap in Doped Lithium Niobate Crystals

Photoinduced light scattering and optical spectroscopy have been used to study the photorefractive effect and determine the band gap in nominally undoped congruent and stoichiometric lithium niobate crystals, as well as in a series of congruent LiNbO{sub 3} crystals doped with Mg, Zn, B, Gd, Y, and Er cations and LiNbO{sub 3} single crystals codoped with Mg:Gd, Mg:Fe, Mg:Y, and Mg:Ta.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exchange Spin Waves in Inhomogeneous Spinel Ferrite Films

This paper examines the effect of dynamic spin pinning at an interlayer boundary on spin wave propagation in monocrystalline manganese ferrite films magnetized along the normal to their surface. We calculate wavenumbers of exchange spin waves, decay parameters, inhomogeneous exchange parameters, and magnon effective masses. The thickness of the spin pinning layer is shown to influence the linewidth of spin wave modes. We demonstrate that, in the competition with magnetocrystalline anisotropy, a significant role is played by “surface anisotropy” in films of various chemical compositions grown by chemical vapor transport under different process conditions.

36 MATERIALS SCIENCE↗

Flux Growth, Thermal Properties, and Luminescence Spectra of (Er,Yb,Lu)Al{sub 3}(BO{sub 3}){sub 4} Solid Solutions

We have studied phase relations in the pseudoquaternary system LuAl{sub 3}(BO{sub 3}){sub 4}–(K{sub 2}Mo{sub 3}O{sub 10}–Al{sub 2}O{sub 3}–B{sub 2}O{sub 3}) in the temperature range 1130 to 900°C. The phase relations were represented in graphical form, as a projection of the formation of solid phases in this range onto the composition triangle at 900°C. Optimal results in terms of high-temperature solution growth have been obtained at 25 wt % LuAl{sub 3}(BO{sub 3}){sub 4} in the growth charge. Undoped and erbium–ytterbium codoped LuAl{sub 3}(BO{sub 3}){sub 4} (LuAB) single crystals have been grown from high-temperature solutions on “pointlike” seeds. The (Er,Yb):LuAB crystals are similar in thermal properties and luminescence spectra to (Er,Yb):YAl{sub 3}(BO{sub 3}){sub 4} and (Er,Yb):GdAl{sub 3}(BO{sub 3}){sub 4} crystals and can be used in diode-pumped lasers operating in the nominally eye-safe spectral region 1.5–1.6 μm.

36 MATERIALS SCIENCE↗