Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROWAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

System to continuously produce carbon fiber via microwave assisted plasma processing

A system to continuously produce fully carbonized or graphitized carbon fibers using microwave-assisted plasma (MAP) processing comprises an elongated chamber in which a microwave plasma is excited in a selected gas atmosphere. Fiber is drawn continuously through the chamber, entering and exiting through openings designed to minimize in-leakage of air. There is a gradient of microwave power within the chamber with generally higher power near where the fiber exits and lower power near where the fiber enters. Polyacrylonitrile (PAN), pitch, or any other suitable organic/polymeric precursor fibers can be used as a feedstock for the inventive system. Oxidized or partially oxidized PAN or pitch or other polymeric fiber precursors are run continuously through a MAP reactor in an inert, non-oxidizing atmosphere to heat the fibers, drive off the unwanted elements such as oxygen, nitrogen, and hydrogen, and produce carbon or graphite fibers faster than conventionally produced carbon fibers.

White, Terry L↗

Apparatus with moderating material for microwave heat treatment of manufactured components

An apparatus for heat treating manufactured components using microwave energy and microwave susceptor material. Heat treating medium such as eutectic salts may be employed. A fluidized bed introduces process gases which may include carburizing or nitriding gases The process may be operated in a batch mode or continuous process mode. A microwave heating probe may be used to restart a frozen eutectic salt bath.

47 OTHER INSTRUMENTATION↗

Near-field scanning microwave microscopy of few-layer graphene.

Near-field microwave microscopy can be used as an alternative to atomic-force microscopy or Raman microscopy in determination of graphene thickness. We evaluated the values of AC impedance for few layer graphene. The impedance of mono and few-layer graphene at 4GHz was found predominantly active. Near-field microwave microscopy allows simultaneous imaging of location, geometry, thickness, and distribution of electrical properties of graphene without device fabrication. Our results may be useful for design of future graphene-based microwave devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theory of Microwave Instability and Coherent Synchrotron Radiation in Electron Storage Rings

Bursting of coherent synchrotron radiation has been observed and in fact used to generate THz radiation in many electron storage rings. In order to understand and control the bursting, we return to the study of the microwave instability. In this paper, we will report on the theoretical understanding, including recent developments, of the microwave instability in electron storage rings. The historical progress of the theories will be surveyed, starting from the dispersion relation of coasting beams, to the work of Sacherer on a bunched beam, and ending with the Oide and Yokoya method of discretization. This theoretical survey will be supplemented with key experimental results over the years. Finally, we will describe the recent theoretical development of utilizing the Laguerre polynomials in the presence of potential-well distortion. This self-consistent method will be applied to study the microwave instability driven the impedances due to the coherent synchrotron radiation. Over the past quarter century, there has been steady progress toward smaller transverse emittances in electron storage rings used for synchrotron light sources, from tens of nm decades ago to the nm range recently. In contrast, there is not much progress made in the longitudinal plane. For an electron bunch in a typical ring, its relative energy spread {sigma}{sub {delta}} remains about 10{sup -3} and its length {sigma}{sub z} is still in between 5 mm to 10 mm. Now the longitudinal emittance ({sigma}{sub {delta}}{sigma}{sub z}) becomes a factor of thousand larger than those in the transverse dimensions. In this paper, we will address questions of: How short a bunch can be? What is the fundamental limit? If there is a limit, is there any mitigation method? Since the synchrotron radiation is so fundamental in electron storage rings, let us start with the coherent synchrotron radiation (CSR).

43 PARTICLE ACCELERATORS↗

Printed circuit board impedance matching step for microwave (millimeter wave) devices

An impedance matching ground plane step, in conjunction with a quarter wave transformer section, in a printed circuit board provides a broadband microwave matching transition from board connectors or other elements that require thin substrates to thick substrate (>quarter wavelength) broadband microwave (millimeter wave) devices. A method of constructing microwave and other high frequency electrical circuits on a substrate of uniform thickness, where the circuit is formed of a plurality of interconnected elements of different impedances that individually require substrates of different thicknesses, by providing a substrate of uniform thickness that is a composite or multilayered substrate; and forming a pattern of intermediate ground planes or impedance matching steps interconnected by vias located under various parts of the circuit where components of different impedances are located so that each part of the circuit has a ground plane substrate thickness that is optimum while the entire circuit is formed on a substrate of uniform thickness.

42 ENGINEERING↗

Distributed coupling and multi-frequency microwave accelerators

A microwave circuit for a linear accelerator has multiple metallic cell sections, a pair of distribution waveguide manifolds, and a sequence of feed arms connecting the manifolds to the cell sections. The distribution waveguide manifolds are connected to the cell sections so that alternating pairs of cell sections are connected to opposite distribution waveguide manifolds. The distribution waveguide manifolds have concave modifications of their walls opposite the feed arms, and the feed arms have portions of two distinct widths. In some embodiments, the distribution waveguide manifolds are connected to the cell sections by two different types of junctions adapted to allow two frequency operation. The microwave circuit may be manufactured by making two quasi-identical parts, and joining the two parts to form the microwave circuit, thereby allowing for many manufacturing techniques including electron beam welding, and thereby allowing the use of un-annealled copper alloys, and hence greater tolerance to high gradient operation.

43 PARTICLE ACCELERATORS↗

Heavy fossil hydrocarbon conversion and upgrading using radio-frequency or microwave energy

Conversion of heavy fossil hydrocarbons (HFH) to a variety of value-added chemicals and/or fuels can be enhanced using microwave (MW) and/or radio-frequency (RF) energy. Variations of reactants, process parameters, and reactor design can significantly influence the relative distribution of chemicals and fuels generated as the product. In one example, a system for flash microwave conversion of HFH includes a source concentrating microwave or RF energy in a reaction zone having a pressure greater than 0.9 atm, a continuous feed having HFH and a process gas passing through the reaction zone, a HFH-to-liquids catalyst contacting the HFH in at least the reaction zone, and dielectric discharges within the reaction zone. The HFH and the catalyst have a residence time in the reaction zone of less than 30 seconds. In some instances, a plasma can form in or near the reaction zone.

Strohm, James J.↗

Microwave Cavity Simulation Using Ansys HFSS

The design of microwave cavity detectors for axion dark matter research is often accomplished using advanced full-wave electromagnetic simulation software tools. These tools provide a cost-effective approach to evaluate a wide variety of cavity configurations, frequency tuning mechanisms, and conductive or dielectric materials and coatings. One simulation software package used for this application is Ansys High Frequency Structure Simulator (HFSS), which is based upon the well-established finite element method. HFSS includes numerous features useful for microwave cavity design such as parametric geometry modeling, adaptive meshing algorithm, curvilinear mesh elements, driven modal and eigenmode matrix solvers, and optimization algorithms. This paper describes the use of the HFSS software to simulate microwave cavities for axion haloscope detectors, with an example tutorial for a cylindrical cavity. Excellent agreement between the simulated and analytical results is shown for the resonant frequency, quality factor, and form factor.

Ansys HFSS, Cavity simulation, finite element mode↗

Microfabricated ion trap chip with an integrated microwave antenna

An ion trap chip, which may be used for quantum information processing and the like, includes an integrated microwave antenna. The antenna is formed as a radiator connected by one of its ends to the center trace of a microwave transmission line and connected by its other end to a current return path through a ground trace of the microwave transmission line. The radiator includes several parallel, coplanar radiator traces connected in series. The radiator traces are connected such that they all carry electric current in the same direction, so that collectively, they simulate a single, unidirectionally flowing sheet of current. In embodiments, induced currents in underlying metallization planes are suppressed by parallel slots that extend in a direction perpendicular to the radiator traces.

Nordquist, Christopher↗

Effect of Catalyst Pretreatment on Methane Conversion under Microwave-assisted and Conventional Thermal Methods

The presentation was delivered from work performed in NETL's Upcycling of Associated Natural Gas FWP Task 4 Benzene, Toluene, Xylene Synthesis via Microwave-assisted catalyst. The objective of this project is to develop a modular, microwave-assisted reactor to upcycle flare gas into valuable chemicals. The presentation discusses important work researchers have performed to compare the pre-treatment of a benchmark Mo/ZSM-5 catalyst under microwaves to traditional thermal heating. Pre-treatment is required to enable to catalyst to produce benzene. This study provided insights into how the exposure impacts the structure and activity of the catalyst and will be used to help design better catalysts.

Abdelsayed, Victor↗

Microwave ignition systems with launcher affixed to or located within a gun spindle

Microwave ignition systems with a launcher affixed to or located within a gun spindle. Use of a planar, impedance matched system that include a launcher affixed to or located within a gun spindle and a receiver affixed the propelling charge, where the receiver is engineered and impedance matched to efficiently deposit energy into the receiving igniter material, may result in significantly better timing and reliability than conventional mechanical gun ignition systems and other microwave ignition systems. A pressure-tolerant feed through system can route the microwave energy to the inside of the breech.

Duque, Amanda Lynn↗

Few-layer graphene characterization by near-field scanning microwave microscopy.

Near-field scanning microwave microscopy is employed for quantitative imaging at 4 GHz of the local impedance for monolayer and few-layer graphene. The microwave response of graphene is found to be thickness dependent and determined by the local sheet resistance of the graphene flake. Calibration of the measurement system and knowledge of the probe geometry allows evaluation of the AC impedance for monolayer and few-layer graphene, which is found to be predominantly active. The use of localized evanescent electromagnetic field in our experiment provides a promising tool for investigations of plasma waves in graphene with wave numbers determined by the spatial spectrum of the near-field. By using near-field microwave microscopy one can perform simultaneous imaging of location, geometry, thickness, and distribution of electrical properties of graphene without a need for device fabrication.

36 MATERIALS SCIENCE↗

Reduced graphene oxide catalytically enhances the rate of cyanate ester curing under variable frequency microwave heating

Here, the curing of Lonza Primaset PT-30 novolac cyanate ester resin and EPON 826 bisphenol-A diglycidyl ether were investigated using convective thermal heating and variable frequency microwave (VFM) heating. The addition of 1 part per hundred reduced graphene oxide (r-GO) to PT-30 novolac cyanate ester increased the VFM cure rate compared to thermal heating. Curing it at 160°C for 240 min with VFM heating resulted in a 55% degree of cure compared to a 26% degree of cure with thermal heating. This observed VFM rate enhancement is due to selective microwave heating of the r-GO particles in the resin resulting in increased r-GO catalytic activity toward cyanate ester curing. It is both a thermal and catalytic effect, the latter of which is absent when r-GO is added to a bisphenol-A diglycidyl ether resin with o-phenylenediamine hardener. Impurities present in the PT-30 matrix do not appear to contribute to its overall cure kinetics, nor do they participate in the observed VFM rate enhancement.

36 MATERIALS SCIENCE↗

Preservation of higher Fe[II] content in borosilicate glass by microwave irradiation in air

Highlights: • Higher Fe[II] absorption within 1000–1200 nm in UV-vis-NIR spectra in microwave (MW) melted glass. • Spectrophotometric methods confirm higher Fe-redox ratio in MW melted glass. • Thermogravimetric analysis (TGA) recorded more weight gain signifying higher stabilisation of Fe[II] in MW melted glass. • Fe 2p{sub 3/2} peak in XPS demonstrates presence of higher FeO concentration in MW glass. • Slow conversation of Fe[II] to Fe[III] in MW heating influencing retention of higher Fe[II]. - Abstract: Existence of high Fe[II] content in glass is a perquisite for achieving high heat absorption property in glass. Present study investigates the capability of microwave (MW) irradiation in retention of higher Fe[II] in glass eliminating the stringent reducing atmosphere requirements in conventional heating. Stabilisation of higher Fe[II] in glass under influence of MW irradiation has been demonstrated, measuring absorbance at >1000 nm in UV–vis-NIR spectra, maintaining identical conditions in MW and in conventional heating. Spectrophotometric methods developing color complex of Fe{sup 2+} with ferrozine and 1, 10 ortho-phenanthroline are used to confirm higher content of Fe[II]. Further, more weight gain in thermo gravimetric analysis, higher isomer shift (>0.89 mm/s) with more relative absorption (% area) for Fe[II] in Mössbauer spectroscopy, and shifting of Fe 2p{sub 3/2} peak in X-ray photoelectron spectroscopy towards lower binding energy further confirm retention of higher FeO under MW irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analytical Morse/long-Range model potential and predicted infrared and microwave spectra for a symmetric top-atom dimer: A case study of CH{sub 3}F–He

Four-dimensional ab initio intermolecular potential energy surfaces (PESs) for CH{sub 3}F–He that explicitly incorporates dependence on the Q{sub 3} stretching normal mode of the CH{sub 3}F molecule and are parametrically dependent on the other averaged intramolecular coordinates have been calculated. Analytical three-dimensional PESs for v{sub 3}(CH{sub 3}F) = 0 and 1 are obtained by least-squares fitting the vibrationally averaged potentials to the Morse/Long-Range potential function form. With the 3D PESs, we employ Lanczos algorithm to calculate rovibrational levels of the dimer system. Following some re-assignments, the predicted transition frequencies are in good agreement with experimental microwave data for ortho-CH{sub 3}F, with the root-mean-square deviation of 0.042 cm{sup −1}. We then provide the first prediction of the infrared and microwave spectra for the para-CH{sub 3}F–He dimer. The calculated infrared band origin shifts associated with the ν{sub 3} fundamental of CH{sub 3}F are 0.039 and 0.069 cm{sup −1} for para-CH{sub 3}F–He and ortho-CH{sub 3}F–He, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Behavior of microwave-heated silicon carbide particles at frequencies of 2.0–13.5 GHz

Silicon carbide is a key material in microwave (MW) processing and is used widely as a thermal insulator and catalytic agent. In this study, we experimentally investigated the temperature dependence of the MW-absorption properties of SiC particles at frequencies of 2.0–13.5 GHz. We heated SiC particles of different sizes using MW radiation. The heating behaviors of the particles were then compared with their MW-absorption properties. The heating behavior of the particles was dependent on their radii; this result was in keeping with theoretical predictions. Furthermore, the β-SiC particles exhibited anomalous behaviors when subjected to microwave heating at temperatures of 1100 °C and higher. These behaviors were attributable to the transformation of β-SiC into the α-phase. The underlying mechanism for this transformation is discussed on the basis of the results of X-ray diffraction analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microwave measurements of the tropolone–formic acid doubly hydrogen bonded dimer

The microwave spectrum was measured for the doubly hydrogen bonded dimer formed between tropolone and formic acid. The predicted symmetry of this dimer was C{sub 2v}(M), and it was expected that the concerted proton tunneling motion would be observed. After measuring 25 a- and b-type rotational transitions, no splittings which could be associated with a concerted double proton tunneling motion were observed. The calculated barrier to the proton tunneling motion is near 15 000 cm{sup −1}, which would likely make the tunneling frequencies too small to observe in the microwave spectra. The rotational and centrifugal distortion constants determined from the measured transitions were A = 2180.7186(98) MHz, B = 470.873 90(25) MHz, C = 387.689 84(22) MHz, D{sub J} = 0.0100(14) kHz, D{sub JK} = 0.102(28) kHz, and D{sub K} = 13.2(81) kHz. The B3LYP/aug-cc-pVTZ calculated rotational constants were within 1% of the experimentally determined values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative measurements of nanoscale permittivity and conductivity using tuning-fork-based microwave impedance microscopy

Here, we report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS 2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-field microwave imaging with small distance modulation.

36 MATERIALS SCIENCE↗