Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOADING RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar radiation on the stringing section, transmits the data to the Transmission Energy Management System, validates its integrity and passes it on to Oncor and ERCOT (Electric Reliability Council of Texas) respective system operations. The iDLR system is automatic and transparent to ERCOT System Operations, i.e., it operates in parallel with all other system status telemetry collected through Supervisory Control and Data Acquisition (SCADA) employed across the company.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of positive plates with various loading levels

The effects of overcharge and total cycling rate on one electrochemically impregnated and four chemically impregnated nickel electrodes are examined. Topics discussed include porosity distribution, electrode corrosion, electrolyte absorption and positive electrode involvement in the decrease in the amount of electrolyte in the separator. The electrochemically impregnated electrode is shown to be superior to all types of conventionally impregnated electrodes regardless of the loading level.

Vanommering, G.↗

Dose Rate Analysis Capability for Actual Spent Fuel Transportation Cask Contents

The approved contents for a U.S. Nuclear Regulatory Commission (NRC) licensed spent nuclear fuel casks are typically based on bounding used nuclear fuel (UNF) characteristics. However, the contents of the UNF canisters currently in storage at independent spent fuel storage installations are considerably heterogeneous in terms of fuel assembly burnup, initial enrichment, decay time, cladding integrity, etc. Used Nuclear Fuel Storage, Transportation & Disposal Analysis Resource and Data System (UNF ST&DARDS) is an integrated data and analysis system that facilitates automated cask-specific safety analyses based on actual characteristics of the as-loaded UNF. The UNF-ST&DARDS analysis capabilities have been recently expanded to include dose rate analysis of as-loaded transportation packages. Realistic dose rate values based on actual canister contents may be used in place of bounding dose rate values to support development of repackaging operations procedures, evaluation of radiation-related transportation risks, and communication with stakeholders. This paper describes the UNF-ST&DARDS dose rate analysis methodology based on actual UNF canister contents and presents sample dose rate calculation results.

Radulescu, Georgeta↗

Orion Entry Handling Qualities Assessments

The Orion Command Module (CM) is a capsule designed to bring crew back from the International Space Station (ISS), the moon and beyond. The atmospheric entry portion of the flight is deigned to be flown in autopilot mode for nominal situations. However, there exists the possibility for the crew to take over manual control in off-nominal situations. In these instances, the spacecraft must meet specific handling qualities criteria. To address these criteria two separate assessments of the Orion CM s entry Handling Qualities (HQ) were conducted at NASA s Johnson Space Center (JSC) using the Cooper-Harper scale (Cooper & Harper, 1969). These assessments were conducted in the summers of 2008 and 2010 using the Advanced NASA Technology Architecture for Exploration Studies (ANTARES) six degree of freedom, high fidelity Guidance, Navigation, and Control (GN&C) simulation. This paper will address the specifics of the handling qualities criteria, the vehicle configuration, the scenarios flown, the simulation background and setup, crew interfaces and displays, piloting techniques, ratings and crew comments, pre- and post-fight briefings, lessons learned and changes made to improve the overall system performance. The data collection tools, methods, data reduction and output reports will also be discussed. The objective of the 2008 entry HQ assessment was to evaluate the handling qualities of the CM during a lunar skip return. A lunar skip entry case was selected because it was considered the most demanding of all bank control scenarios. Even though skip entry is not planned to be flown manually, it was hypothesized that if a pilot could fly the harder skip entry case, then they could also fly a simpler loads managed or ballistic (constant bank rate command) entry scenario. In addition, with the evaluation set-up of multiple tasks within the entry case, handling qualities ratings collected in the evaluation could be used to assess other scenarios such as the constant bank angle maintenance case. The 2008 entry assessment was divided into two sections (see Figure 1). Entry I was the first, high speed portion of a lunar return and Entry II was the second, lower speed portion of a lunar return, which is similar (but not identical) to a typical ISS return.

Bihari, B.↗

Toward Environmentally Friendly Lithium Sulfur Batteries: Probing the Role of Electrode Design in MoS 2 -Containing Li–S Batteries with a Green Electrolyte

While lithium sulfur batteries (Li–S) hold promise as future high energy density low cost energy storage systems, barriers to implementation include low sulfur loading, limited cycle life, and the use of toxic electrolyte solvents. A comprehensive study of Li–S cells in the environmentally benign di(propylene glycol) dimethyl ether (DPGDME)-based electrolyte, using as-prepared MoS 2 nanosheets derived from a facile aqueous microwave synthesis as polysulfide trapping agents, is reported herein for the first time. Conventional coated foil electrodes and binder-free electrodes (BFEs) with various structures are systematically generated and tested to correlate electrode design with the resulting electrochemical behavior. Significantly improved Li–S electrochemistry is demonstrated through the synergy of MoS 2 chemistry and binder-free electrode engineering. In the coating configuration, the MoS 2 -containing cell evinced better rate performance and more stable cyclability than the cell without MoS 2 . In comparison with the coating counterparts, the BFE cells exhibited excellent cycle stability and superior rate capability (10-fold capacities and energy density per electrode weight with 20% higher retention rate) despite 2X higher areal sulfur loading. As a result, the BFE cell improvement can be attributed to the synergistic effect of the i) interconnected macroporous structure of CNT interlayers, providing a conductive framework, and ii) the efficient polysulfide trapping by the MoS 2 nanosheets.

25 ENERGY STORAGE↗

Thermally Stratified Compression Ignition: A new advanced low temperature combustion mode with load flexibility

We introduce a new advanced combustion mode, called Thermally Stratified Compression Ignition (TSCI), which uses direct water injection to control both the average temperature and the temperature distribution prior to ignition, thereby providing cycle-to-cycle control over the start and rate of heat release in Low Temperature Combustion (LTC). Experiments were conducted to fundamentally understand the effects of water injection on heat release in LTC. Our results show that water injection retards the start of combustion due to the latent heat of vaporization of the injected water. Furthermore, for start of water injection timings between 20 and 70 degrees before top dead center, combustion is significantly elongated compared to without water injection. The 10–90% burn duration with 6.6 and 9.0 mg of water per cycle was 77% and 146% longer than without water injection, respectively. Forced thermal stratification result from a direct water injection which reduces the heat release rate by local evaporative cooling. Finally, the load limits with and without water injection were determined experimentally. Without water injection, the load range was 2.3–3.6 bar gross IMEP. By using water injection to control heat release, the load range in TSCI was 2.3–8.4 bar gross IMEP, which is a range expansion of over 350%. These results demonstrate that direct water injection can provide significant improvements to both controllability and the range of operability of LTC, thereby resolving the major challenges associated with HCCI.

20 FOSSIL-FUELED POWER PLANTS↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗

Characterization of Shocked Beryllium

Beryllium metal has many excellent structural properties in addition to its unique radiation characteristics, including: high elastic modulus, low Poisson's ratio, low density, and high melting point. However, it suffers from several major mechanical drawbacks: 1) high anisotropy - due to its hexagonal lattice structure and its susceptibility to crystallographic texturing; 2) susceptibility to impurity-induced fracture - due to grain boundary segregation; and 3) low intrinsic ductility at ambient temperatures thereby limiting fabricability. While large ductility results from deformation under the conditions of compression, the material can exhibit a brittle behavior under tension. Furthermore, there is a brittle to ductile transition at approximately 200 C under tensile conditions. While numerous studies have investigated the low-strain-rate constitutive response of beryllium, the combined influence of high strain rate and temperature on the mechanical behavior and microstructure of beryllium has received limited attention over the last 40 years. Prior studies have focused on tensile loading behavior, or limited conditions of dynamic strain rate and/or temperature. The beryllium used in this study was Grade S200-F (Brush Wellman, Inc., Elmore, OH) material. The work focused on high strain rate deformation and examine the validity of constitutive models in deformation rate regimes, including shock, the experiments were modeled using a Lagrangian hydrocode. Two constitutive strength (plasticity) models, the Preston-Tonks-Wallace (PTW) and Mechanical Threshold Stress (MTS) models, were calibrated using the same set of quasi-static and Hopkinson bar data taken at temperatures from 77K to 873K and strain rates from 0.001/sec to 4300/sec. In spite of being calibrated on the same data, the two models give noticeably different results when compared with the measured wave profiles. These high strain rate tests were conducted using both explosive drive and a gas gun to accelerate the material. Preliminary analysis of the results appears to indicate that, if fractured by the initial shock loading, the S200F Be remains sufficiently intact to support a shear stress following partial release and subsequent shock re-loading of the material. Additional 'arrested' drive shots were designed and tested to minimize the reflected tensile pulse in the sample. These tests were done to both validate the model and to put large shock induced compressive loads into the beryllium sample.

36 MATERIALS SCIENCE↗

Highly Resolved Reference Projections of Building Energy Use for the Contiguous United States: Building Sector Energy Baselines, Projection Methods, and Results

This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Loads assessment of a fixed-bottom offshore wind farm with wake steering

Wake steering via deliberate yaw offset is an emerging wind farm control technique that has the potential to mitigate wake losses and further increase wind farm energy yield. The loads impact of this technique has been studied, but there is limited insight into wind-farm-wide impacts of wake steering. Understanding such impacts is crucial to determining the feasibility of using wake steering in commercial wind farms. To that end, this work investigates the impacts of wake steering on the loads of all turbine components across all turbines in a wind farm operating under a broad set of inflow conditions, including inflow velocity, shear exponent, turbulence class, and inflow angle. This was done by performing FAST.Farm simulations of a 12-turbine wind farm array, excerpted from a larger hypothetical wind farm. The International Energy Agency Wind 15-MW reference wind turbine was modeled atop a monopile substructure, an open-source model that closely approximates the properties of similar commercial options. Wake steering was included via yaw offsets that were computed using an offline optimization with the National Renewable Energy Laboratory tool FLORIS. For each inflow case, the 12-turbine array was simulated with and without wake steering. Results were compared in terms of time-averaged means, standard deviations, ultimate loads, and damage-equivalent loads. The findings show that because wake steering is generally applied at rated wind speeds and below, it is unlikely to drive ultimate loads. For fatigue loads, wake steering does increase the overall fatigue accumulation for some load channels, such as blade-root and shaft bending. This is to be expected when overall power yield increases but may cause the damage accumulation to be more uniform throughout the array. The significance of the added fatigue loading is dependent on how frequent wake steering is utilized in the overall set of inflow conditions across the wind rose.

17 WIND ENERGY↗

Machine learning surrogate of physics-based building-stock simulator for end-use load forecasting

Building energy models are used to simulate heat and mass transfer and estimate end-use load in buildings. With the proliferation of solar photovoltaics on residential and commercial buildings, increasingly, buildings are expected to provide grid services, for which accurate and computationally efficient building energy simulations and end-use load prediction are imperative. Existing building energy simulation tools, however, have significant computational overhead that make them less practical in real-time deployment for optimization, design, uncertainty quantification and control in building energy management systems. Here this article presents a data-driven machine learning model based on light gradient boosting method (LightGBM) as a surrogate for a physics-based simulator for residential buildings to predict end-use load. The machine learning based surrogate model accounts for time-series related variables, seasonality and trend component of end-use load, and history of end-use load. The accuracy of the surrogate model is assessed on the prediction of the load profiles of 100 different houses in Cook County, Illinois, USA. The LightGBM surrogate model is shown to reduce the root-mean-squared error by 53% relative to a reference decision tree (DT) based model reported previously in the literature. Moreover, the model predicts the load spikes and high-ramp rate events throughout the year which are often the Achilles heel of other models in the literature. The machine learning based surrogate model is demonstrated to be computationally efficient, with a ten-fold reduction in the computational time compared to a physics-based building energy simulation, and suitable for uncertainty analysis and real-time control of building characteristics in response to uncertainty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dose-rate distribution of {sup 32}P-glass microspheres for intra-arterial brachytherapy

Purpose: The intra-arterial administration of radioactive glass microspheres is an alternative therapy option for treating primary hepatocellular carcinoma, the main cause of liver cancer death, and metastatic liver cancer, another important kind of cancer induced in the liver. The technique involves the administration of radioactive microspheres in the hepatic artery, which are trapped preferentially in the tumor. Methods: In this work the GEANT4 toolkit was used to calculate the radial dose-rate distributions in water from {sup 32}P-loaded glass microspheres and also from {sup 90}Y-loaded glass microspheres. To validate the toolkit for this application, the authors compared the dose-rate distribution of {sup 32}P and {sup 90}Y point sources in water with data from the International Commission on Radiation Units and Measurements report 72. Results: Tables of radial dose-rate distributions are provided for practical use in brachytherapy planning with these microspheres. Conclusions: The simulations with the microspheres show that the shape of the beta ray energy spectra with respect to the {sup 32}P and {sup 90}Y sources is significantly modified by the glass matrix.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of Physics Models for Phase Transition Kinetics

The time dependence of phase diagrams and how to model rate dependent transitions remains one of the key unanswered questions in physics. When a material is loaded dynamically through equilibrium phase boundaries, it is the kinetics that determines the real time expression of a phase transition. Here we report the atomic and nanosecond-scale quantification of kinetics of shock-driven phase transition in multiple materials. We uniquely make use of a both a simple shock as well as shock-and-hold loading pathways compress different crystalline solids and induce structural phase transitions below melt. Coupling shock loading with time-resolved synchrotron x-ray diffraction (DXRD), we probe the structural transformations of these solids in the short-lived high pressure and temperature states generated. The novelty and power of using DXRD for the assessment of kinetics of phase transitions lies in the ability to discover and identify new phases and to examine kinetics without prior knowledge of a material's phase diagram. Our results provide a quantified expression and a physics model of kinetics of formation of high-pressure phases under shock loading: transition incubation time, evolution, completion time and crystallization rate.

36 MATERIALS SCIENCE↗

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recovery Act: Energy Efficiency of Data Networks through Rate Adaptation (EEDNRA) - Final Technical Report

This Concept Definition Study focused on developing a scientific understanding of methods to reduce energy consumption in data networks using rate adaptation. Rate adaptation is a collection of techniques that reduce energy consumption when traffic is light, and only require full energy when traffic is at full provisioned capacity. Rate adaptation is a very promising technique for saving energy: modern data networks are typically operated at average rates well below capacity, but network equipment has not yet been designed to incorporate rate adaptation. The Study concerns packet-switching equipment, routers and switches; such equipment forms the backbone of the modern Internet. The focus of the study is on algorithms and protocols that can be implemented in software or firmware to exploit hardware power-control mechanisms. Hardware power-control mechanisms are widely used in the computer industry, and are beginning to be available for networking equipment as well. Network equipment has different performance requirements than computer equipment because of the very fast rate of packet arrival; hence novel power-control algorithms are required for networking. This study resulted in five published papers, one internal report, and two patent applications, documented below. The specific technical accomplishments are the following: • A model for the power consumption of switching equipment used in service-provider telecommunication networks as a function of operating state, and measured power-consumption values for typical current equipment. • An algorithm for use in a router that adapts packet processing rate and hence power consumption to traffic load while maintaining performance guarantees on delay and throughput. • An algorithm that performs network-wide traffic routing with the objective of minimizing energy consumption, assuming that routers have less-than-ideal rate adaptivity. • An estimate of the potential energy savings in service-provider networks using feasibly-implementable rate adaptivity. • A buffer-management algorithm that is designed to reduce the size of router buffers, and hence energy consumed. • A packet-scheduling algorithm designed to minimize packet-processing energy requirements. Additional research is recommended in at least two areas: further exploration of rate-adaptation in network switching equipment, including incorporation of rate-adaptation in actual hardware, allowing experimentation in operational networks; and development of control protocols that allow parts of networks to be shut down while minimizing disruption to traffic flow in the network. The research is an integral part of a large effort within Bell Laboratories, Alcatel-Lucent, aimed at dramatic improvements in the energy efficiency of telecommunication networks. This Study did not explicitly consider any commercialization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Centaur Standard Shroud (CSS) static ultimate load structural tests

A series of tests were conducted on the jettisonable metallic shroud used on the Titan/Centaur launch vehicle to verify its structural capabilities and to evaluate its structural interaction with the Centaur stage. A flight configured shroud and the interfacing Titan/Centaur structural assemblies were subjected to tests consisting of combinations of applied axial and shear loads to design ultimate values, including a set of tests on thermal conditions and two dynamic response tests to verify the analytical stiffness model. The strength capabilities were demonstrated at ultimate (125 percent of design limit) loads. It was also verified that the spring rate of the flight configured shroud-to-Centaur forward structural deflections of the specimen became nonlinear, as expected, above limit load values. This test series qualification program verified that the Titan/Centaur shroud and the Centaur and Titan interface components are qualified structurally at design ultimate loads.

Source record↗

A unified creep-plasticity model suitable for thermo-mechanical loading

An experimentally based unified creep-plasticity constitutive model was implemented for 1070 steel. Accurate rate and temperature effects were obtained for isothermal and thermo-mechanical loading by incorporating deformation mechanisms into the constitutive equations in a simple way.

Slavik, D.↗