Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.

60 APPLIED LIFE SCIENCES↗

Comparison of sparse domain approaches for 4D SPECT dynamic image reconstruction

Purpose: Dynamic imaging (DI) provides additional diagnostic information in emission tomography in comparison to conventional static imaging at the cost of being computationally more challenging. Dynamic single photon emission computed tomography (SPECT) reconstruction is particularly difficult because of the limitations in the sampling geometry present in most existing scanners. We have developed an algorithm Spline Initialized Factor Analysis of Dynamic Structures (SIFADS) that is a matrix factorization method for reconstructing the dynamics of tracers in tissues and blood directly from the projections in dynamic cardiac SPECT, without first resorting to any 3D reconstruction. Methods: SIFADS is different from "pure" factor analysis in dynamic structures (FADS) in that it employs a dedicated spline-based pre-initialization. In this paper, we analyze the convergence properties of SIFADS and FADS using multiple metrics. The performances of the two approaches are evaluated for numerically simulated data and for real dynamic SPECT data from canine and human subjects. Results: For SIFADS, metrics analyzed for reconstruction algorithm convergence show better features of the metric curves vs iterations. In addition, SIAFDS provides better tissue segmentations than that from pure FADS. Measured computational times are also typically better for SIFADS implementations than those with pure FADS. Conclusion: The analysis supports the utility of the pre-initialization of a factorization algorithm for better dynamic SPECT image reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-222: Feasibility Study of MRI-Only Proton Therapy Planning

Purpose: To assess the dosimetric equivalence of MRI based proton planning vs. single energy x-ray CT. Methods: 8 glioblastoma patients were imaged with CT and MRI after surgical resection. T1-weighted 3DMPRAGE was used to delineate the GTV, which was subsequently rigidly registered to the CT volume. A pseudoCT was generated from the aligned MRI by combining segmentation and atlas-based approaches. The spatial resolution both for pseudo- and real CT was 0.6×0.6×2.5mm. Three orthogonal proton beams were simulated on the pseudoCT. Two co-planar beams were set on the axial plane. The third one was planned parallel to the cranio-caudal (CC) direction. Each beam was set to cover the GTV at 98% of the nominal dose (18Gy). The proton plan was copied and transferred to the real CT, including aperture/compensator geometry. Dose comparison between pseudoCT and CT plan was performed beam-by-beam by quantifying the range shift of dose profile on each slice of the GTV. The GTV’s V{sub 98} was computed for the CT. Results: For beams in axial plane the median absolute value of the range shift was 0.3mm, with 0.9mm and 1.4mm as 95th percentile and maximum, respectively. Worst scenarios were found for the CC beam, where we measured 1.1mm (median), 2.7mm (95thpercentile) and 5mm (maximum). Regardless the direction, beams passing through the surgical site, where metal (Titanium MRI-compatible) staples were present, were mostly affected by range shift. GTV’s V{sub 98} for CT was not lower than 99.3%. Conclusion: The study showed the clinical feasibility of an MRI-alone proton plan. Advantages include the possibility to rely on better soft tissue contrast for target and organs at risk delineation without the need of further CT scan and image registration. Additional investigation is required in presence of metal implants along the beam path and to account for partial volume effects due to slice thickness.

60 APPLIED LIFE SCIENCES↗

EVOLUTION OF A MAGNETIC FLUX ROPE AND ITS OVERLYING ARCADE BASED ON NONLINEAR FORCE-FREE FIELD EXTRAPOLATIONS

Dynamic phenomena indicative of slipping reconnection and magnetic implosion were found in a time series of nonlinear force-free field (NLFFF) extrapolations for the active region 11515, which underwent significant changes in the photospheric fields and produced five C-class flares and one M-class flare over five hours on 2012 July 2. NLFFF extrapolation was performed for the uninterrupted 5 hour period from the 12 minute cadence vector magnetograms of the Helioseismic and Magnetic Imager on board the Solar Dynamic Observatory. According to the time-dependent NLFFF model, there was an elongated, highly sheared magnetic flux rope structure that aligns well with an Hα filament. This long filament splits sideways into two shorter segments, which further separate from each other over time at a speed of 1-4 km s{sup –1}, much faster than that of the footpoint motion of the magnetic field. During the separation, the magnetic arcade arching over the initial flux rope significantly decreases in height from ∼4.5 Mm to less than 0.5 Mm. We discuss the reality of this modeled magnetic restructuring by relating it to the observations of the magnetic cancellation, flares, a filament eruption, a penumbra formation, and magnetic flows around the magnetic polarity inversion line.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Multimodal Few-Shot Analytics for Electron Micrographs

Recent advances in materials data analytics have provided new avenues for determining process-structure-property (PSP) linkages in a variety of materials. Machine learning techniques including few-shot learning have increased the efficiency of classifying microscopy images for the purposes of material characterization. Attempts at creating a multimodal approach can provide further improvements to current models and help extract more salient features from data. In this vein, raw spectrum data was taken to provide an additional modality to our current pyCHIP classifier. Modifications in segmentation also show potential in improving the accuracy of the pyCHIP classifier. Classifier output was analyzed using network graphs and unsupervised clustering algorithms such as spectral clustering to detect better segmentation methods than the current “chipping” approach. We suggest that the chip selection process can be automated in the future using a combination of these techniques to enable high-throughput analyses.

36 MATERIALS SCIENCE↗

Interactive contour delineation of organs at risk in radiotherapy: Clinical evaluation on NSCLC patients

Purpose: Accurate delineation of organs at risk (OARs) on computed tomography (CT) image is required for radiation treatment planning (RTP). Manual delineation of OARs being time consuming and prone to high interobserver variability, many (semi-) automatic methods have been proposed. However, most of them are specific to a particular OAR. Here, an interactive computer-assisted system able to segment various OARs required for thoracic radiation therapy is introduced. Methods: Segmentation information (foreground and background seeds) is interactively added by the user in any of the three main orthogonal views of the CT volume and is subsequently propagated within the whole volume. The proposed method is based on the combination of watershed transformation and graph-cuts algorithm, which is used as a powerful optimization technique to minimize the energy function. The OARs considered for thoracic radiation therapy are the lungs, spinal cord, trachea, proximal bronchus tree, heart, and esophagus. The method was evaluated on multivendor CT datasets of 30 patients. Two radiation oncologists participated in the study and manual delineations from the original RTP were used as ground truth for evaluation. Results: Delineation of the OARs obtained with the minimally interactive approach was approved to be usable for RTP in nearly 90% of the cases, excluding the esophagus, which segmentation was mostly rejected, thus leading to a gain of time ranging from 50% to 80% in RTP. Considering exclusively accepted cases, overall OARs, a Dice similarity coefficient higher than 0.7 and a Hausdorff distance below 10 mm with respect to the ground truth were achieved. In addition, the interobserver analysis did not highlight any statistically significant difference, at the exception of the segmentation of the heart, in terms of Hausdorff distance and volume difference. Conclusions: An interactive, accurate, fast, and easy-to-use computer-assisted system able to segment various OARs required for thoracic radiation therapy has been presented and clinically evaluated. The introduction of the proposed system in clinical routine may offer valuable new option to radiation oncologists in performing RTP.

60 APPLIED LIFE SCIENCES↗

First Sagittarius A* Event Horizon Telescope Results. IV. Variability, Morphology, and Black Hole Mass

In this paper we quantify the temporal variability and image morphology of the horizon-scale emission from Sgr A*, as observed by the EHT in 2017 April at a wavelength of 1.3 mm. We find that the Sgr A* data exhibit variability that exceeds what can be explained by the uncertainties in the data or by the effects of interstellar scattering. The magnitude of this variability can be a substantial fraction of the correlated flux density, reaching ~100% on some baselines. Through an exploration of simple geometric source models, we demonstrate that ring-like morphologies provide better fits to the Sgr A* data than do other morphologies with comparable complexity. We develop two strategies for fitting static geometric ring models to the time-variable Sgr A* data; one strategy fits models to short segments of data over which the source is static and averages these independent fits, while the other fits models to the full data set using a parametric model for the structural variability power spectrum around the average source structure. Both geometric modeling and image-domain feature extraction techniques determine the ring diameter to be 51.8 ± 2.3 μas (68% credible intervals), with the ring thickness constrained to have an FWHM between ~30% and 50% of the ring diameter. To bring the diameter measurements to a common physical scale, we calibrate them using synthetic data generated from GRMHD simulations. This calibration constrains the angular size of the gravitational radius to be ${4.8}_{-0.7}^{+1.4}$ μas, which we combine with an independent distance measurement from maser parallaxes to determine the mass of Sgr A* to be ${4.0}_{-0.6}^{+1.1}\times {10}^{6}$ M⊙.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments and treatment time. Varian Medical Systems; NIH grant R01CA188300; NIH grant R43CA183390.

60 APPLIED LIFE SCIENCES↗

Digital twins and deep learning segmentation of defects in monolayer MX 2 phases

Developing methods to understand and control defect formation in nanomaterials offers a promising route for materials discovery. Monolayer MX 2 phases represent a particularly compelling case for defect engineering of nanomaterials due to the large variability in their physical properties as different defects are introduced into their structure. However, effective identification and quantification of defects remain a challenge even as high-throughput scanning transmission electron microscopy methods improve. This study highlights the benefits of employing first principles calculations to produce digital twins for training deep learning segmentation models for defect identification in monolayer MX 2 phases. Around 600 defect structures were obtained using density functional theory calculations, with each monolayer MX 2 structure being subjected to multislice simulations for the purpose of generating the digital twins. Several deep learning segmentation architectures were trained on this dataset, and their performances evaluated under a variety of conditions such as recognizing defects in the presence of unidentified impurities, beam damage, grain boundaries, and with reduced image quality from low electron doses. Further, this digital twin approach allows benchmarking different deep learning architectures on a theory dataset, which enables the study of defect classification under a broad array of finely controlled conditions. It thus opens the door to resolving the underpinning physical reasons for model shortcomings and potentially chart paths forward for automated discovery of materials defect phases in experiments.

36 MATERIALS SCIENCE↗

VANO: a volume-object image annotation system

Volume-object annotation system (VANO) is a cross-platform image annotation system that enables one to conveniently visualize and annotate 3D volume objects including nuclei and cells. An application of VANO typically starts with an initial collection of objects produced by a segmentation computation. The objects can then be labeled, categorized, deleted, added, split, merged and redefined. VANO has been used to build high-resolution digital atlases of the nuclei of Caenorhabditis elegans at the L1 stage and the nuclei of Drosophila melanogaster’s ventral nerve cord at the late embryonic stage.

59 BASIC BIOLOGICAL SCIENCES↗

A computerized scheme for lung nodule detection in multiprojection chest radiography

Purpose: Our previous study indicated that multiprojection chest radiography could significantly improve radiologists' performance for lung nodule detection in clinical practice. In this study, the authors further verify that multiprojection chest radiography can greatly improve the performance of a computer-aided diagnostic (CAD) scheme. Methods: Our database consisted of 59 subjects, including 43 subjects with 45 nodules and 16 subjects without nodules. The 45 nodules included 7 real and 38 simulated ones. The authors developed a conventional CAD scheme and a new fusion CAD scheme to detect lung nodules. The conventional CAD scheme consisted of four steps for (1) identification of initial nodule candidates inside lungs, (2) nodule candidate segmentation based on dynamic programming, (3) extraction of 33 features from nodule candidates, and (4) false positive reduction using a piecewise linear classifier. The conventional CAD scheme processed each of the three projection images of a subject independently and discarded the correlation information between the three images. The fusion CAD scheme included the four steps in the conventional CAD scheme and two additional steps for (5) registration of all candidates in the three images of a subject, and (6) integration of correlation information between the registered candidates in the three images. The integration step retained all candidates detected at least twice in the three images of a subject and removed those detected only once in the three images as false positives. A leave-one-subject-out testing method was used for evaluation of the performance levels of the two CAD schemes. Results: At the sensitivities of 70%, 65%, and 60%, our conventional CAD scheme reported 14.7, 11.3, and 8.6 false positives per image, respectively, whereas our fusion CAD scheme reported 3.9, 1.9, and 1.2 false positives per image, and 5.5, 2.8, and 1.7 false positives per patient, respectively. The low performance of the conventional CAD scheme may be attributed to the high noise level in chest radiography, and the small size and low contrast of most nodules. Conclusions: This study indicated that the fusion of correlation information in multiprojection chest radiography can markedly improve the performance of CAD scheme for lung nodule detection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multidimensional profiling of cell surface proteins and nuclear markers

Cell membrane proteins play an important role in tissue architecture and cell-cell communication. We hypothesize that segmentation and multidimensional characterization of the distribution of cell membrane proteins, on a cell-by-cell basis, enable improved classification of treatment groups and identify important characteristics that can otherwise be hidden. We have developed a series of computational steps to (i) delineate cell membrane protein signals and associate them with a specific nucleus; (ii) compute a coupled representation of the multiplexed DNA content with membrane proteins; (iii) rank computed features associated with such a multidimensional representation; (iv) visualize selected features for comparative evaluation through heatmaps; and (v) discriminate between treatment groups in an optimal fashion. The novelty of our method is in the segmentation of the membrane signal and the multidimensional representation of phenotypic signature on a cell-by-cell basis. To test the utility of this method, the proposed computational steps were applied to images of cells that have been irradiated with different radiation qualities in the presence and absence of other small molecules. These samples are labeled for their DNA content and E-cadherin membrane proteins. We demonstrate that multidimensional representations of cell-by-cell phenotypes improve predictive and visualization capabilities among different treatment groups, and identify hidden variables.

60 APPLIED LIFE SCIENCES↗

POINT-SPREAD FUNCTIONS FOR THE EXTREME-ULTRAVIOLET CHANNELS OF SDO/AIA TELESCOPES

We present the stray-light point-spread functions (PSFs) and their inverses we characterized for the Atmospheric Imaging Assembly (AIA) EUV telescopes on board the Solar Dynamics Observatory (SDO) spacecraft. The inverse kernels are approximate inverses under convolution. Convolving the original Level 1 images with them produces images with improved stray-light characteristics. We demonstrate the usefulness of these PSFs by applying them to two specific cases: photometry and differential emission measure (DEM) analysis. The PSFs consist of a narrow Gaussian core, a diffraction component, and a diffuse component represented by the sum of a Gaussian-truncated Lorentzian and a shoulder Gaussian. We determined the diffraction term using the measured geometry of the diffraction pattern identified in flare images and the theoretically computed intensities of the principal maxima of the first few diffraction orders. To determine the diffuse component, we fitted its parameterized model using iterative forward-modeling of the lunar interior in the SDO/AIA images from the 2011 March 4 lunar transit. We find that deconvolution significantly improves the contrast in dark features such as miniature coronal holes, though the effect was marginal in bright features. On a percentage-scattering basis, the PSFs for SDO/AIA are better by a factor of two than that of the EUV telescope on board the Transition Region And Coronal Explorer mission. A preliminary analysis suggests that deconvolution alone does not affect DEM analysis of small coronal loop segments with suitable background subtraction. We include the derived PSFs and their inverses as supplementary digital materials.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster — Thur Eve — 70: Automatic lung bronchial and vessel bifurcations detection algorithm for deformable image registration assessment

Purpose: To investigate an automatic bronchial and vessel bifurcations detection algorithm for deformable image registration (DIR) assessment to improve lung cancer radiation treatment. Methods: 4DCT datasets were acquired and exported to Varian treatment planning system (TPS) EclipseTM for contouring. The lungs TPS contour was used as the prior shape for a segmentation algorithm based on hierarchical surface deformation that identifies the deformed lungs volumes of the 10 breathing phases. Hounsfield unit (HU) threshold filter was applied within the segmented lung volumes to identify blood vessels and airways. Segmented blood vessels and airways were skeletonised using a hierarchical curve-skeleton algorithm based on a generalized potential field approach. A graph representation of the computed skeleton was generated to assign one of three labels to each node: the termination node, the continuation node or the branching node. Results: 320 ± 51 bifurcations were detected in the right lung of a patient for the 10 breathing phases. The bifurcations were visually analyzed. 92 ± 10 bifurcations were found in the upper half of the lung and 228 ± 45 bifurcations were found in the lower half of the lung. Discrepancies between ten vessel trees were mainly ascribed to large deformation and in regions where the HU varies. Conclusions: We established an automatic method for DIR assessment using the morphological information of the patient anatomy. This approach allows a description of the lung's internal structure movement, which is needed to validate the DIR deformation fields for accurate 4D cancer treatment planning.

60 APPLIED LIFE SCIENCES↗

Heterodyne frequency-domain multispectral diffuse optical tomography of breast cancer in the parallel-plane transmission geometry

Purpose: The authors introduce a state-of-the-art all-optical clinical diffuse optical tomography (DOT) imaging instrument which collects spatially dense, multispectral, frequency-domain breast data in the parallel-plate geometry. Methods: The instrument utilizes a CCD-based heterodyne detection scheme that permits massively parallel detection of diffuse photon density wave amplitude and phase for a large number of source–detector pairs (10{sup 6}). The stand-alone clinical DOT instrument thus offers high spatial resolution with reduced crosstalk between absorption and scattering. Other novel features include a fringe profilometry system for breast boundary segmentation, real-time data normalization, and a patient bed design which permits both axial and sagittal breast measurements. Results: The authors validated the instrument using tissue simulating phantoms with two different chromophore-containing targets and one scattering target. The authors also demonstrated the instrument in a case study breast cancer patient; the reconstructed 3D image of endogenous chromophores and scattering gave tumor localization in agreement with MRI. Conclusions: Imaging with a novel parallel-plate DOT breast imager that employs highly parallel, high-resolution CCD detection in the frequency-domain was demonstrated.

60 APPLIED LIFE SCIENCES↗

A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model

A computer-aided detection (CAD) system for the selection of lung nodules in computer tomography (CT) images is presented. The system is based on region growing (RG) algorithms and a new active contour model (ACM), implementing a local convex hull, able to draw the correct contour of the lung parenchyma and to include the pleural nodules. The CAD consists of three steps: (1) the lung parenchymal volume is segmented by means of a RG algorithm; the pleural nodules are included through the new ACM technique; (2) a RG algorithm is iteratively applied to the previously segmented volume in order to detect the candidate nodules; (3) a double-threshold cut and a neural network are applied to reduce the false positives (FPs). After having set the parameters on a clinical CT, the system works on whole scans, without the need for any manual selection. The CT database was recorded at the Pisa center of the ITALUNG-CT trial, the first Italian randomized controlled trial for the screening of the lung cancer. The detection rate of the system is 88.5% with 6.6 FPs/CT on 15 CT scans (about 4700 sectional images) with 26 nodules: 15 internal and 11 pleural. A reduction to 2.47 FPs/CT is achieved at 80% efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accurate determination of segmented X-ray detector geometry

Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. Furthermore, we show that the refined detector geometry greatly improves the results of experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗