Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

High intensity high charge state ion beam production with an evaporative cooling magnet ECRIS

LECR4 (Lanzhou ECR ion source No. 4) is a room temperature electron cyclotron resonance ion source, designed to produce high current, high charge state ion beams for the SSC-LINAC injector (a new injector for sector separated cyclotron) at the Institute of Modern Physics. LECR4 also serves as a PoP machine for the application of evaporative cooling technology in accelerator field. To achieve those goals, LECR4 ECR ion source has been optimized for the operation at 18 GHz. During 2014, LECR4 ion source was commissioned at 18 GHz microwave of 1.6 kW. To further study the influence of injection stage to the production of medium and high charge state ion beams, in March 2015, the injection stage with pumping system was installed, and some optimum results were produced, such as 560 eμA of O{sup 7+}, 620 eμA of Ar{sup 11+}, 430 eμA of Ar{sup 12+}, 430 eμA of Xe{sup 20+}, and so on. The comparison will be discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Langmuir probe characterization of laser ablation plasmas

For laser ablation plumes that are significantly ionized, Langmuir probes have proved to be a useful tool for measuring the plume shape, ion energy distribution, and electron temperature. Typically in laser ablation plasmas the flow velocity is supersonic, which complicates the interpretation of the current-voltage probe characteristic. In this paper we describe some recent developments on the application of Langmuir probes for laser ablation plume diagnosis. We have investigated the behavior of the probe when it is orientated perpendicular, and parallel, to the plasma flow, and show how an analytical model developed for plasma immersion ion implantation, can quantitatively describe the variation of the ion current with probe bias for the case when the plasma flow is along the probe surface. The ion signal recorded by a probe in the parallel position is proportional to the ion density and the square root of the bias voltage. It is shown that the current varies as m{sub i}{sup -1/2} so that by comparing the ion signals from the parallel and perpendicular positions it is possible to estimate the mass of the ions detected. We have also determined the temporal variation of electron temperature. A planar probe oriented parallel to the plasma flow, where the ion current due to the plasma flow is eliminated, gives a more reliable measurement of T{sub e} (<0.6 eV). The measured T{sub e} is consistent with the measured ion current, which is dependent on T{sub e} when the time taken for an element of plasma to traverse the probe is longer than the time taken for the matrix ion sheath extraction phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Role of Ion Acoustic Instability in the Development of the Azimuthal Current Density Profile in Liner Experiments at 1 MA

Recent work reported on the current density in pulsed-power-driven liners where a vacuum gap was introduced in the power feed connecting the liner to the generator. The resultant gap flashover generates azimuthally localized current-carrying plasma channels, which can create an azimuthal nonuniformity in the current density. The current density evolves during the current pulse, but nonuniformity is observed through the experiment timescale. Magnetohydrodynamic simulation work in 3-D demonstrates the difficulty in reproducing the experimental data within a limited computational domain, and those boundary conditions may dominate this paper. Furthermore, the development of current-driven instabilities in the plasma channels can explain the liner current density evolution, and specifically the ion acoustic instability can account for the main features observed in the experiments.

36 MATERIALS SCIENCE↗

Multilayer Electrodes with Metalized Polymer Current Collector for High-Energy Lithium-Ion Batteries with Extreme-Fast-Charging Capability

The pursuit of batteries capable of extreme fast charging (XFC), that also satisfy high energy and safety criteria, poses a significant challenge to current lithium-ion battery technologies. Additionally, the increasing demand for aluminum (Al) and copper (Cu) in electrification, and vehicle light weighting is driving these metals towards near-critical status in the medium term. This study introduced metalized polymer films by depositing an Al or Cu thin layer onto two sides of a polyethylene terephthalate (PET) film – named mPET/Al and mPET/Cu, as lightweight, cost-effective alternatives to traditional metal current collectors in LIBs. We have utilized current collectors that significantly reduce weight (by 73%), thickness (by 33%), and cost (by 85%) compared to traditional metal foil counterparts. We conducted an extensive evaluation of their mechanical and electrical properties, including in-plane and through-plane resistivities, affirming their suitability for the roll-to-roll battery manufacturing process. Additionally, a novel XFC testing protocol was employed to thoroughly assess the cells' (both half and full-cell) performance across various C-rates and under long-term tests. These advancements have the potential to enhance energy density to 280 Wh/kg at the electrode level under 10-minute charging at 6C. Through testing, including a novel XFC protocol across various C-rates and long-term cycling (up to 1000 cycles) in different cell configurations, we have demonstrated the superior performance of these metalized polymer films. Notably, mPET/Cu and mPET/Al foils exhibited comparable capacities to conventional cells under XFC, with the mPET cells showing a 27% improvement in energy density at 6C and maintaining significant energy density after 1000 cycles. This study underscored the potential of mPET foils to revolutionize the roll-to-roll battery manufacturing process and significantly advance the performance metrics of LIBs in EV applications. Moreover, our results suggest that there is potential to enhance the performance of mPET foils, especially mPET/Al, by optimizing the manufacturing process to achieve higher conductivity.

99 GENERAL AND MISCELLANEOUS↗

Multilayer Electrodes with Metalized Polymer Current Collector for High-Energy Lithium-Ion Batteries with Extreme-Fast-Charging Capability

The pursuit of batteries capable of extreme fast charging (XFC), that also satisfy high energy and safety criteria, poses a significant challenge to current lithium-ion battery technologies. Additionally, the increasing demand for aluminum (Al) and copper (Cu) in electrification, and vehicle lightweighting is driving these metals towards near-critical status in the medium term. This study introduced metalized polymer films by depositing an Al or Cu thin layer onto two sides of a polyethylene terephthalate (PET) film – named mPET/Al and mPET/Cu, as lightweight, cost-effective alternatives to traditional metal current collectors in LIBs.

25 ENERGY STORAGE↗

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

99 GENERAL AND MISCELLANEOUS↗

The Nonlinear Coupling of Electromagnetic Ion Cyclotron and Lower Hybrid Waves in the Ring Current Region: The Magnetic Storm May 1-7 1998

The excitation of lower hybrid waves (LHWs) is a widely discussed mechanism of interaction between plasma species in space, and is one of the unresolved questions of magnetospheric multi-ion plasmas. In this paper we present the morphology, dynamics, and level of LHW activity generated by electromagnetic ion cyclotron (EMIC) waves during the May 2-7, 1998 storm period on the global scale. The LHWs were calculated based on our newly developed self-consistent model that couples the system of two kinetic equations: one equation describes the ring current (RC) ion dynamic, and another equation describes the evolution of EMIC waves. It is found that the LHWs are excited by helium ions due to their mass dependent drift in the electric field of EMIC waves. The level of LHW activity is calculated assuming that the induced scattering process is the main saturation mechanism for these waves. The calculated LHWs electric fields are consistent with the observational data.

Khazanov, G. V.↗

Effects of fast monoenergetic electrons on the ion dynamics near the cathode in a pulsed direct current plasma sheath

A detailed one-dimensional simulation of the ion dynamics of the plasma sheath near a substrate (cathode) in the presence of fast monoenergetic electrons has been carried out in this article. The sheath evolution is investigated by using a fluid model assuming that the ions, plasma electrons and monoenergetic, fast electrons act as three fluids (fluid approach). The effect of the density of fast electrons on the ion density, ion velocity, and ion energy near the cathode and the evolution of the sheath boundary in front of the cathode are separately explored. Also, the variation of the ion velocity and ion density at the vicinity of the cathode as a function of time is investigated in the absence and presence of the electron beam. Results indicate that the presence of fast electrons in the sheath causes significant change in the sheath thickness and therefore basically changes the ion velocity, ion density, and ion impact energy on the cathode compared to the absence of the electron beam case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transverse acceleration of ions on auroral field lines

This paper examines transverse ion heating on auroral field lines associated with current-driven electrostatic ion cyclotron waves theoretically and by numerical simulations. The auroral plasma is assumed to consist of drifting electrons and stationary hydrogen and oxygen ions. Depending on the ratio of the electron drift speed to the thermal speed and the ratio of hydrogen to oxygen concentrations, preferential heating of either hydrogen or oxygen ions can take place. It is found that unless the oxygen ions are a minority species, oxygen transverse heating generally exceeds that of hydrogen ions. Theory and numerical simulations are in good agreement.

Ashour-Abdalla, M.↗

Spiky parallel dc electric fields in the aurora

A series of computer simulations is reported on the detailed shape and distribution of the dc electric fields that result when an external potential drop is applied to a plasma with strong low-frequency turbulence. The structures are shown to depend on the size of the potential drop and upon the shape of the ion turbulence. For the type of turbulence expected for current driven electrostatic ion cyclotrron waves the dc fields seen in the simulations are in good agreement with those observed in the aurora.

Rowland, H. L.↗

Plasma Pressure Distribution of Ions and Electrons in the Inner Magnetosphere During CIR Driven Storms Observed During Arase Era

Here, using Arase observations of the inner magnetosphere during 26 CIR-driven geomagnetic storms with minimum Sym-H between –33 and –86 nT, we investigated ring current pressure development of ions (H + , He + , O + ) and electron during prestorm, main, early recovery and late recovery phases as a function of L-shell and magnetic local time. It is found that during the main and early recovery phase of the storms the ion pressure is asymmetric in the inner magnetosphere, leading to a strong partial ring current. The ion pressure becomes symmetric during the late recovery phase. H + ions with energies of ~20–50 keV and ~50–100 keV contribute more to the ring current pressure during the main phase and early/late recovery phase, respectively. O + ions with energies of ~10–20 keV contribute significantly during main and early recovery phase. These are consistent with previous studies. The electron pressure was found to be asymmetric during the main, early recovery and late recovery phase. The electron pressure peaks from midnight to the dawn sector. Electrons with energy of <50 keV contribute to the ring current pressure during the main and early recovery phase of the storms. Overall, the electron contribution to the total ring current is found to be ~11% during the main and early recovery phases. However, the electron contribution is found to be significant (~22%) in the 03–09 MLT sector during the main and early recovery phase. The results indicate an important role of electrons in the ring current build up.

79 ASTRONOMY AND ASTROPHYSICS↗

A two-dimensional numerical study of ion-acoustic turbulence

We investigate the linear and nonlinear evolution of the current-driven ion-acoustic instability in a collisionless plasma via two-dimensional (2-D) Vlasov–Poisson numerical simulations. We initialise the system in a stable state and gradually drive it towards instability with an imposed, weak external electric field, thus avoiding physically unrealisable super-critical initial conditions. A comprehensive analysis of the nonlinear evolution of ion-acoustic turbulence (IAT) is presented, including the detailed characteristics of the evolution of the particles’ distribution functions, (2-D) wave spectrum and the resulting anomalous resistivity. Our findings reveal the dominance of 2-D quasi-linear effects around saturation, with nonlinear effects, such as particle trapping and nonlinear frequency shifts, becoming pronounced during the later stages of the system's nonlinear evolution. Remarkably, the Kadomtsev–Petviashvili (KP) spectrum is observed immediately after the saturation of the instability. Another crucial and noteworthy result is that no steady saturated nonlinear state is ever reached: strong ion heating suppresses the instability, which implies that the anomalous resistivity associated with IAT is transient and short-lived, challenging earlier theoretical results. Towards the conclusion of the simulation, electron-acoustic waves are triggered by the formation of a double layer and strong modifications to the particle distribution induced by IAT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DEVELOPMENT OF AN APPROACH TO MODELING LOADING AND ELUTION OF SPHERICAL RESORCINOL FORMALDEHYDE ION-EXCHANGE RESIN

The current strategy for removal of cesium from the Hanford waste stream is ion-exchange using spherical Resorcinol-Formaldehyde (sRF) resin. The original resin of choice was granular SuperLig 644 resin and during testing of this resin several operational issues were identified. For example, the granular material had a high angle of internal friction resulting in fragmentation of resin particles along its edges during cycling and adverse hydraulic performance. Efforts to replace SuperLig 644 were undertaken and one candidate was the granular Resorcinol-Formaldehyde (RF) resin where experience with this cation exchanger dates back to the late 1940's. To minimize hydraulic concerns a spherical version of RF was developed and several different chemically produced batches were created. The 5E-370/641 batch of sRF was selected and for the last decade numerous studies have been performed (e.g., batch contact tests, column loading and elution tests). The Waste Treatment Plant (WTP) flowsheet shows that the aqueous phase waste stream will have a wide range of ionic concentrations (e.g., during the loading step 0-3 M free OH, 5+ M Na, 0-1 M K, 0-3 M NO{sub 3}). Several steps are required in the ion-exchange process to achieve the required Cs separation factors: loading, displacement, washing, elution, and regeneration. The sRF resin will be operated over a wide range in pH (i.e., pH of 12-14 during the loading step and pH of 0.01-1 during the elution step). During some of these steps very high levels of counter-ions and co-ions will be present within the aqueous phase. Alternative process feeds are under consideration as well (e.g., sodium levels as high as 8 M and column operation up to 45 C during loading, reduced and recycled HNO{sub 3} during elution). In order to model the performance of sRF resin through an entire ion-exchange cycle, a more robust isotherm model is required. To achieve this more robust isotherm model requires knowledge of the numbers and kinds of fixed ionogenic groups that make up sRF. Recent literature reviews and scoping titration tests strongly indicate that sRF is a polyfunctional cation exchange resin with at least three dominant types of ring groups playing a role in its isotherm behavior over the wide pH range of operations. Also three types of fixed ionogenic acid groups are present: sulfonic (SO{sub 3}H{sup -}) groups; carboxylic (COOH{sup -}) groups, and resorcylic (OH{sup -}) groups. It is this premise that we are working under in the development of a robust isotherm model for sRF over its entire planned pH operating range. The application of prototypic isotherms for modeling ion-exchange column behavior is demonstrated in Section 3 of this report. This preliminary work served to focus the development effort on the use of a mass-action based isotherm. In Section 4 of this report, the foundational material required to develop a robust isotherm model for sRF is provided. The paths taken, and choices made, are given for the reader to better understand our current status with respect to this goal and to highlight our most recent understanding of sRF exchange equilibria. Our ultimate goal is to update the CERMOD code (Aleman and Hamm, 2007) with a robust isotherm model for sRF that spans the entire pH and concentration ranges of planned operations. The isotherm model will then be used in the VERSE-LC code to model an entire ion-exchange cycle.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A time-resolved laser induced fluorescence study on the ion velocity distribution function in a Hall thruster after a fast current disruption

The temporal characteristics of the Xe{sup +} ion axial velocity distribution function (VDF) were recorded in the course of low-frequency discharge current oscillations ({approx}14 kHz) of the 5 kW class PPS X000 Hall thruster. The evolution in time of the ion axial velocity component is monitored by means of a laser induced fluorescence diagnostic tool with a time resolution of 100 ns. As the number of fluorescence photons is very low during such a short time period, a homemade pulse-counting lock-in system was used to perform real-time discrimination between background photons and fluorescence photons. The evolution in time of the ion VDF was observed at three locations along the thruster channel axis after a fast shutdown of the thruster power. The anode discharge current is switched off at 2 kHz during 5 {mu}s without any synchronization with the current oscillation cycle. This approach allows to examine the temporal behavior of the ion VDF during decay and ignition of the discharge as well as during forced and natural plasma oscillations. Measurements show that the distribution function of the axial component of the Xe{sup +} ion does change periodically in time with a frequency close to the current oscillation frequency in both forced and natural cases. The ion density and the mean velocity are found to oscillate, whereas the velocity dispersion stays constant, which indicates that ionization and acceleration layers have identical dynamics. Finally, variations over time in the electric field are for the first time experimentally evidenced in a crossed-field discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-energy dc ion source for low operating pressure

We report on an experimental study of an ion source based on a Penning discharge with a cold hollow cathode in crossed electric and magnetic fields. The minimum vacuum chamber operating pressure was 3 × 10{sup −5} Torr for argon and 5 × 10{sup −5} Torr for hydrogen. The use of a hollow cathode allowed decreasing the discharge operating voltage down to 350 V at a discharge current of ∼100 mA. At a discharge current of 100 mA and beam accelerating voltage of 2 kV, the ion current was 2.5 mA for argon and 8 mA for hydrogen, and the ion beam on-axis current density 170 and 450 μA/cm{sup 2}, respectively. The current-voltage characteristics of the discharge and the radial ion beam current density distribution were measured. The influence of pressure on the discharge parameters and their time stability was investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semi-analytical modeling of the NIO1 source

NIO1 is a compact and versatile negative ion source, with a total current of 130 mA accelerated to 60 keV. Negative ions are created inside the plasma, which is inductively coupled to an external rf cylindrical coil operating in the range of 2 ± 0.2 MHz. The plasma is confined in the source chamber (a 50 mm radius cylinder) by a multipole magnetic field and the ions are extracted through a 3x3 matrix of apertures. The use of cesium, to enhance the negative ion production by H{sub 0} bombardment of the surfaces, is foreseen in a second stage of the operation, so that at present time the source is operating in pure volume configuration. This paper presents a model aimed to describe the main physical phenomena occurring in the source, focusing on the rf coupling with the plasma and the evolution of plasma parameters in the source. With respect to more sophisticated models of negative ion sources here we aimed to develop a fast tool capable of qualitatively describing the response of the system to variations in the basic operating parameters. The findings of this models is finally compared with the first experimental results of NIO1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-382: Influence of Compton Currents On Profile Measurements in Small- Volume Ion Chambers

Purpose: Ionization chambers in electron radiation fields are known to exhibit polarity effects due to Compton currents. Previously we have presented a unique manifestation of this effect observed with a microionization chamber. We have expanded that investigation to include three micro-ionization chambers commonly used in radiation therapy. The purpose of this project is to determine what factors influence this polarity effect for micro-chambers and how it might be mitigated. Methods: Three chambers were utilized: a PTW 31016, an Exradin A-16, and an Exradin A- 26. Beam profile scans were obtained on a Varian TrueBeam linear accelerator in combination with a Wellhofer water phantom for 6, 9, and 12 MeV electrons. Profiles were obtained parallel and perpendicular to the chamber's long axis, with both positive and negative collecting bias. Profiles were obtained with various chamber components shielded by 5 mm of Pb at 6 MeV to determine their relative contributions to this polarity effect. Results: The polarity effect was observed for all three chambers, and the ratio of the polarity effect for the Exradin chambers is proportional to the ratio of chamber volumes. Shielding the stem of both Exradin chambers diminished, but did not remove the polarity effect. However, they demonstrated no out-of-field effect when the cable was shielded with Pb. The PTW chamber demonstrated a significantly reduced polarity effect without any shielding despite its comparable volume with the A-26. Conclusions: The sensitive volume of these micro-chambers is relatively insensitive to collecting polarity. However, charge deposition within the cable can dramatically alter measured ionization profiles. This is demonstrated by the removal of the out-of-field ionization when the cable is shielded for the Exradin chambers. We strongly recommend analyzing any polarity dependence for small-volume chambers used in characterization of electron fields.

07 ISOTOPE AND RADIATION SOURCES↗

Current Collector Corrosion in Ca-Ion Batteries

With significant improvements in electrical energy storage, researchers could change the way energy is generated and used. We report that one emerging approach is to change the cation that shuttles charge from lithium to calcium. Calcium cations, roughly the same size as Na + , have many attributes that make them a desirable charge carrier for energy storage applications, including deposition voltage and a porous passivation layer. However, system level issues, such as corrosion, have yet to be investigated. Corrosion of the current collectors must be considered whenever you change the electrolyte and we show that this is particularly true for calcium based systems. Reversible charge/discharge behavior that is due to corrosion can be seen with stainless steel in electrolytes containing calcium salts. This reversible behavior is similar to what might be expected from materials that are intercalating Ca, making the interpretation of electrochemical data challenging. Lastly, we have found that this corrosion reaction requires either carbon black and/or a transition metal oxide to catalyze the reaction, making it more difficult to detect. Unlike stainless steel, Graphite foil electrodes do not show high voltage reactions and can be used as a tool for testing Ca-ion cathode materials, although some reactions at low potentials have been observed.

25 ENERGY STORAGE↗