Recent Developments on Airborne Forward Looking Interferometer for the Detection of Wake Vortices

A goal of these studies was development of the measurement methods and algorithms necessary to detect wake vortex hazards in real time from either an aircraft or ground-based hyperspectral Fourier Transform Spectrometer (FTS). This paper provides an update on research to model FTS detection of wake vortices. The Terminal Area Simulation System (TASS) was used to generate wake vortex fields of 3-D winds, temperature, and absolute humidity. These fields were input to the Line by Line Radiative Transfer Model (LBLRTM), a hyperspectral radiance model in the infrared, employed for the FTS numerical modeling. An initial set of cases has been analyzed to identify a wake vortex IR signature and signature sensitivities to various state variables. Results from the numerical modeling case studies will be presented. Preliminary results indicated that an imaging IR instrument sensitive to six narrow bands within the 670 to 3150 per centimeter spectral region would be sufficient for wake vortex detection. Noise floor estimates for a recommended instrument are a current research topic.

Daniels, Taumi S.↗

The HOSTS Survey for Exozodiacal Dust: Observational Results from the Complete Survey

The Large Binocular Telescope Interferometer (LBTI) enables nulling interferometric observations across the N band (8 to 13 μm) to suppress a star's bright light and probe for faint circumstellar emission. We present and statistically analyze the results from the LBTI/Hunt for Observable Signatures of Terrestrial Systems survey for exozodiacal dust. By comparing our measurements to model predictions based on the solar zodiacal dust in the N band, we estimate a 1σ median sensitivity of 23 zodis times the solar system dust surface density in its habitable zone (HZ; 23 zodis) for early-type stars and 48 zodis for Sun-like stars, where 1 zodi is the surface density of HZ dust in the solar system. Of the 38 stars observed, 10 show significant excess. A clear correlation of our detections with the presence of cold dust in the systems was found, but none with the stellar spectral type or age. The majority of Sun-like stars have relatively low HZ dust levels (best-fit median: 3 zodis, 1σ upper limit: 9 zodis, 95% confidence: 27 zodis based on our N band measurements), while ~20% are significantly more dusty. The solar system's HZ dust content is consistent with being typical. Our median HZ dust level would not be a major limitation to the direct imaging search for Earth-like exoplanets, but more precise constraints are still required, in particular to evaluate the impact of exozodiacal dust for the spectroscopic characterization of imaged exo-Earth candidates.

Exozodiacal dust↗

A system level testbed for a mid-infrared beam-combiner for Terrestrial Planet Finder

Direct optical detection of earth-like planets orbiting nearby stars is the goal of the Terrestrial Planet Finder project. One instrument which may have the capability to detect such small, faint objects in proximity to the parent star is the infra-red nulling interferometer. A four input beam combiner is being built to test apsects of the beam combination and planet detection problem. This paper describes the design developed for a ground testbed.

Martin, Stefan↗

A heterodyne interferometer for angle metrology

We have developed a compact, high-resolution, angle measurement instrument based on a heterodyne interferometer. Common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer set up, an optical mask is used to sample the laser beam reflecting back from four areas on a target surface. From the relative displacement measurements of the target surface areas, we can simultaneously determine angular rotations around two orthogonal axes in a plane perpendicular to the measurement beam propagation direction. The device is used in a testbed for a tracking telescope system where pitch and yaw angle measurements of a flat mirror are performed. Angle noise measurement of the device shows 0.1 nrad/{radical}(Hz) at 1 Hz, at a working distance of 1 m. The operation range and nonlinearity of the device when used with a flat mirror is approximately {+-}0.15 mrad, and 3 {mu}rad rms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical and Experimental Study of Optical Coherence Tomography (OCT) Signals Using an Analytical Transport Model

Optical coherence tomography (OCT) is a non-invasive low coherent interferometric technique that provides cross-sectional images of turbid media. OCT is based on the classical Michelson interferometer where the mirror of the reference arm is oscillating and the signal arm contains a biological sample. In this work, we analyzed theoretically the heterodyne optical signal adopting the so called extended Huygens-Fresnel principle (EHFP). We use simulated OCT images with known optical properties to test an algorithm developed by ourselves to recover the scattering coefficient and we recovered the scattering coefficient with a relative error less than 5% for noisy signals. In addition, we applied this algorithm to OCT images from phantoms of known optical properties; in this case curves were indistinguishable. A revision of the validity of the analytical model applied to our system should be done.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High speed nano-metrology

For manufacturing at the nanometre scale a method for rapid and accurate measurement of the resultant functional devices is required. Although atomic force microscopy (AFM) has the requisite spatial resolution, it is severely limited in scan speed, the resolution and repeatability of vertical and lateral measurements being degraded when speed is increased. Here we present a new approach to AFM that makes a direct and feedback-independent measurement of surface height using a laser interferometer focused onto the back of the AFM tip. Combining this direct height measurement with a passive, feedback-free method for maintaining tip-sample contact removes the constraint on scan speed that comes from the bandwidth of the z-feedback loop. Conventional laser reflection detection is used for feedback control, which now plays the role of minimising tip-sample forces, rather than producing the sample topography. Using the system in conjunction with a rapid scanner, true height images are obtained with areas up to (36 x 36) {mu}m{sup 2} at 1 image/second, suitable for in-line applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Manipulation of the resonance interaction in Mach-Zehnder-Fano interferometers

We study tunable interaction of the resonances in the Mach-Zehnder-Fano interferometers (MZFIs). A discrete Mach-Zehnder interferometer (MZI) with balanced arms supports bound states in the continuum. We demonstrate that doping an impurity in conventional MZIs gives rise to robust high-Q Fano resonances with asymmetric line shapes. By means of the modified Fano-Anderson model and the scattering-matrix approach, we show that the transmission and the intensity spectra of the whole system are very sensitive to both the location and the strength of the impurity. The side-coupled Fano defects induce an interaction with different eigenmodes of the pure MZI loop. We explore this interaction by tuning the parameters of the Fano defects. The observed resonance interaction can be attributed to the Fano-Feshbach resonance. We further provide with a particular physical example of photonic crystal circuit the applicability of our concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Plateau de Bure + 30 m arcsecond whirlpool survey reveals a thick disk of diffuse molecular gas in the M51 galaxy

We present the data of the Plateau de Bure Arcsecond Whirlpool Survey, a high spatial and spectral resolution {sup 12}CO (1-0) line survey of the inner ∼10 × 6 kpc of the M51 system, and the first wide-field imaging of molecular gas in a star-forming spiral galaxy with resolution matched to the typical size of giant molecular clouds (40 pc). We describe the observation, reduction, and combination of the Plateau de Bure Interferometer (PdBI) and IRAM-30 m 'short spacing' data. The final data cube attains 1.''1 resolution over the ∼270'' × 170'' field of view, with sensitivity to all spatial scales from the combination of PdBI and IRAM-30 m data, and a brightness sensitivity of 0.4 K (1σ) in each 5 km s{sup –1}-wide channel map. We find a CO luminosity of 9 × 10{sup 8} K km s{sup –1} pc{sup 2}, corresponding to a molecular gas mass of 4 × 10{sup 9} M {sub ☉} for a standard CO-to-H{sub 2} conversion factor. Unexpectedly, we find that a large fraction of this emission, (50 ± 10)%, arises mostly from spatial scales larger than 36'' ≅ 1.3 kpc. Through a series of tests, we demonstrate that this extended emission does not result from a processing artifact. We discuss its origin in light of the stellar component, the {sup 12}CO/{sup 13}CO ratio, and the difference between the kinematics and structure of the PdBI-only and hybrid synthesis (PdBI + IRAM-30 m) images. The extended emission is consistent with a thick, diffuse disk of molecular gas with a typical scale height of ∼200 pc, substructured in unresolved filaments that fill ∼0.1% of the volume.

79 ASTRONOMY AND ASTROPHYSICS↗

Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS were found to be different due to the difference in the tomosynthesis image reconstruction algorithms. Conclusions: It is feasible to simultaneously generate x-ray differential phase contrast, phase contrast, and absorption contrast tomosynthesis images using a grating-based data acquisition setup. The method shows promise in improving the visibility of several low-density materials and therefore merits further investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote sensing of water vapor features

Water vapor plays a critical role in the atmosphere. It is an important medium of energy exchange between air, land, and water; it is a major greenhouse gas, providing a crucial radiative role in the global climate system; and it is intimately involved in many regional scale atmospheric processes. Our research has been aimed at improving satellite remote sensing of water vapor and better understanding its role in meteorological processes. Our early studies evaluated the current GOES VAS system for measuring water vapor and have used VAS-derived water vapor data to examine pre-thunderstorm environments. Much of that research was described at the 1991 Research Review. A second research component has considered three proposed sensors--the High resolution Interferometer Sounder (HIS), the Multispectral Atmospheric Mapping Sensor (MAMS), and the Advanced Microwave Sounding Unit (AMSU). We have focused on MAMS and AMSU research during the past year and the accomplishments made in this effort are presented.

Fuelberg, Henry E.↗

Optically thin cirrus clouds - Radiative impact on the warm pool

The role of the radiative effects of thin cirrus clouds in the energy balance of the 'warm pool' region is examined with reference to data obtained by the Infrared Interferometer Spectrometer (IRIS) flown on the Nimbus 4 satellite in 1970. First, the IRIS observations and a method for deriving the thin cirrus information are briefly discussed. A simple radiative energy balance model is then developed which is applicable to the mesoscale convective systems in the 'warm pool'. The radiative energy balance model, which does not explicitly account for the transports, is used to demonstrate the net radiative heating produced by the thin cirrus clouds.

Prabhakara, C.↗

Assimilation of IASI and AIRS Data: Information Content and Quality Control

The Infrared Atmospheric Sounding Interferometer (IASI) and Atmospheric Infrared Sounder (AIRS) instruments have two orders of magnitude more channels that the current operational infrared sounder (High Resolution Infra-Red Sounder (HIRS)). This data volume presents a technological challenge for using the data in a data assimilation system. Data reduction will be a necessary for assimilation. It is important to understand the information content of the radiance measurements for data reduction purposes. In this talk, I will discuss issues relating to information content and quality control for assimilation of the AIRS and IASI data.

Joiner, J.↗

To Boldly Go: America's Next Era in Space. The Plasma Universe

Dr. France Cordova, NASA's Chief Scientist, chaired this, the eighth seminar in the Administrator's Seminar Series. She introduced the NASA Administrator, Daniel S. Goldin, who, in turn, introduced the subject of plasma. Plasma, an ionized gas, is a function of temperature and density. We ve learned that, at Jupiter, the radiation is dense. But, Goldin asked, what else do we know? Dr. Cordova then introduced Dr. James Van Allen, for whom the Van Allen radiation belt was named. Dr. Van Allen, a member of the University of Iowa faculty, discussed the growing interest in practical applications of space physics, including radiation fields and particles, plasmas and ionospheres. He listed a hierarchy of magnetic fields, beginning at the top, as pulsars, the Sun, planets, interplanetary medium, and interstellar medium. He pointed out that we have investigated eight of the nine known planets,. He listed three basic energy sources as 1) kinetic energy from flowing plasma such as constitutional solar wind or interstellar wind; 2) rotational energy of the planet, and 3) orbital energy of satellites. He believes there are seven sources of energetic particles and five potential places where particles may go. The next speaker, Dr. Ian Axford of New Zealand, has been associated with the Max Planck Institut fuer Aeronomie and plasma physics. He has studied solar and galactic winds and clusters of galaxies of which there are several thousand. He believes that the solar wind temperature is in the millions of degrees. The final speaker was Dr. Roger Blanford of the California Institute of Technology. He classified extreme plasmas as lab plasmas and cosmic plasmas. Cosmic plasmas are from supernovae remnants. These have supplied us with heavy elements and may come via a shock front of 10(sup 15) electron volts. To understand the physics of plasma, one must learn about x-rays, the maximum energy of acceleration by supernova remnants, particle acceleration and composition of cosmic rays, maximum acceleration, and how fast protons are heated by ions. He asked questions about where high energy cosmic rays are made, what accelerates electrons, radiates gamma rays, makes electronpositron plasma, and finally noted that pulsars are good time keepers, but we need a better understanding of their mechanism and of plasmas, both cosmic and ground-based. In the discussion period, Goldin asked if NASA should put up an x-ray interferometer. The answer was no; gamma rays are of greater interest just now. Goldin also asked what the assembled scientists would like to see for a future mission? They expressed an interest in learning more about the origin of galaxies, cosmic rays, solar systems, planets, the existence of life "out there", gamma ray sources, the nature of gamma ray bursts, and the flow of gases around black holes. The discussion concluded with a suggestion that NASA should communicate to the general public more information regarding actual technological trials and tribulations involved in getting an experiment to work. The speakers thought that this would help non-scientists to better appreciate what it is that NASA does in connection with the benefits that are achieved.

Source record↗

Zernike-like Orthogonal Basis Functions for Wavefront Characterization over Sampled, Irregular Apertures

For optical systems with circular apertures, wavefronts are often analyzed using Zernike polynomials, and individual Zernike functions are associated with familiar optical aberrations. For systems with noncircular apertures, or in practical situations in which wavefronts are measured at a limited number of points in the aperture, the Zernike polynomials are no longer an orthogonal basis for the measured data. Although there are an endless number of ways to create a basis for such measured data, a "Zernike-like" basis is useful to connect with our experience with the usual optical aberrations. In this paper, the steps required to identify a Zernike-like basis for wavefronts over sampled, irregular apertures are presented, based on the Gram-Schmidt orthogonalization technique. The benefits of analyzing optical wavefronts using an orthogonal basis specific to an optical system's aperture shape and wavefront sampling, instead of using the traditional Zernike polynomials, are detailed in two examples, from image-based wavefront sensing on a segmented-aperture telescope (the James Webb Space Telescope Testbed Telescope at Ball Aerospace) and from interferometer characterization for surface metrology of a hexagonal mirror segment.

Aronstein, David L.↗

Binary Black Hole Late Inspiral: Simulations for Gravitational Wave Observations

Coalescing binary black hole mergers are expected to be the strongest gravitational wave sources for ground-based interferometers, such as the LIGO, VIRGO, and GEO600, as well as the spacebased interferometer LISA. Until recently it has been impossible to reliably derive the predictions of General Relativity for the final merger stage, which takes place in the strong-field regime. Recent progress in numerical relativity simulations is, however, revolutionizing our understanding of these systems. We examine here the specific case of merging equal-mass Schwarzschild black holes in detail, presenting new simulations in which the black holes start in the late inspiral stage on orbits with very low eccentricity and evolve for approximately 1200M through approximately 7 orbits before merging. We study the accuracy and consistency of our simulations and the resulting gravitational waveforms, which encompass approximately 14 cycles before merger, and highlight the importance of using frequency (rather than time) to set the physical reference when comparing models. Matching our results to PN calculations for the earlier parts of the inspiral provides a combined waveform with less than half a cycle of accumulated phase error through the entire coalescence. Using this waveform, we calculate signal-to-noise ratios (SNRs) for iLIGO, adLIGO, and LISA, highlighting the contributions from the late-inspiral and merger-ringdown parts of the waveform which can now be simulated numerically. Contour plots of SNR as a function of z and M show that adLIGO can achieve SNR 2 10 for some IMBBHs out to z approximately equals 1, and that LISA can see MBBHs in the range 3 x 10(exp 4) approximately < M/Mo approximately < 10(exp 7) at SNR > 100 out to the earliest epochs of structure formation at z > 15.

Baker, John G.↗

Radio Telescope Focal Container for the Russian VLBI Network of New Generation

This article considers the development of the structure of receivers for Russian radio telescopes. The development of these radio telescopes is undertaken within the project for creating a Russian small-antenna-based radio interferometer of new generation. It is shown that for small antennas (10. 12 meter) the principal unit, which provides the best SNR, is the so-called focal container placed at primary focus. It includes the primary feed, HEMT LNA, and cryogenic cooling system down to 20. K. A new multi-band feed based on traveling wave resonators is used. It has small dimensions, low weight, and allows working with circular polarizations. Thus it can be placed into focal container and cooled with the LNA. A sketch of the focal container, with traveling-wave-resonator feed, and calculations of the expected parameters of the multi-band receiver are presented.

Ipatov, Alexander↗

A Short-Range Distance Sensor with Exceptional Linearity

A sensor has been demonstrated that can measure distance over a total range of about 300 microns to an accuracy of about 0.1 nm (resolution of about 0.01 nm). This represents an exceptionally large dynamic range of operation - over 1,000,000. The sensor is optical in nature, and requires the attachment of a mirror to the object whose distance is being measured. This work resulted from actively developing a white light interferometric system to be used to measure the depths of defects in the Space Shuttle Orbiter windows. The concept was then applied to measuring distance. The concept later expanded to include spectrometer calibration. In summary, broadband (i.e., white) light is launched into a Michelson interferometer, one mirror of which is fixed and one of which is attached to the object whose distance is to be measured. The light emerging from the interferometer has traveled one of two distances: either the distance to the fixed mirror and back, or the distance to the moving mirror and back. These two light beams mix and produce an interference pattern where some wavelengths interfere constructively and some destructively. Sending this light into a spectrometer allows this interference pattern to be analyzed, yielding the net distance difference between the two paths. The unique feature of this distance sensor is its ability to measure accurately distance over a dynamic range of more than one million, the ratio of its range (about 300 microns) to its accuracy (about 0.1 nanometer). Such a large linear operating range is rare and arises here because both amplitude and phase-matching algorithms contribute to the performance. The sensor is limited by the need to attach a mirror of some kind to the object being tracked, and by the fairly small total range, but the exceptional dynamic range should make it of interest.

Simmons, Steven↗