Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

WIPP WAC Equivalence Support Measurements for Low-Level Sludge Waste at Los Alamos National Laboratory - 12242

Los Alamos National Laboratory (LANL) uses the Nevada National Security Site (NNSS) as an off-site disposal facility for low-level waste (LLW), including sludge waste. NNSS has issued a position paper that indicates that systems that are not certified by the Carlsbad Field Office (CBFO) for Waste Isolation Pilot Plant (WIPP) disposal of Transuranic (TRU) waste must demonstrate equivalent practices to the CBFO certified systems in order to assign activity concentration values to assayed items without adding in the Total Measurement Uncertainty (TMU) when certifying waste for NNSS disposal. Efforts have been made to meet NNSS requirements to accept sludge waste for disposal at their facility. The LANL LLW Characterization Team uses portable high purity germanium (HPGe) detector systems for the nondestructive assay (NDA) of both debris and sludge LLW. A number of performance studies have been conducted historically by LANL to support the efficacy and quality of assay results generated by the LANL HPGe systems, and, while these detector systems are supported by these performance studies and used with LANL approved procedures and processes, they are not certified by CBFO for TRU waste disposal. Beginning in 2009, the LANL LLW Characterization Team undertook additional NDA measurements of both debris and sludge simulated waste containers to supplement existing studies and procedures to demonstrate full compliance with the NNSS position paper. Where possible, Performance Demonstration Project (PDP) drums were used for the waste matrix and PDP sources were used for the radioactive sources. Sludge drums are an example of a matrix with a uniform distribution of contaminants. When attempting to perform a gamma assay of a sludge drum, it is very important to adequately simulate this uniform distribution of radionuclides in order to accurately model the assay results. This was accomplished by using a spiral radial source tube placement in a sludge drum rather than the standard three source tubes seen in debris PDP drums. Available line sources (Eu-152) were placed in the spiral tubes to further accomplish the desired uniform distribution of radionuclides. The standard PDP drum (PDP matrix drum 005) and PDP sources were used to determine the lower limits of detection (LLD) and TMU. Analysis results for the sludge drum matrix case for two HPGe detectors were tabulated and evaluated. NNSS has accepted the methodology and results of the measurements towards demonstrating equivalence to CBFO certified systems. In conclusion, the WES-WGS and CMR-OPS gamma spectroscopy teams at LANL have defined and performed measurements that serve to establish and demonstrate equivalency with the processes used by CBFO certified NDA systems. The supplemental measurements address four key areas in Appendix A of DOE/WIPP-02-3122: Annual Calibration Confirmation and Performance Check measurements; LLD determination; and TMU definition. For these measurements the containers, matrices and activity loadings are selected to represent items being assayed in real LLW cases. The LLD and the TMU bounding measurements are to be performed one time and will not be required to be repeated in future campaigns. The annual calibration and performance check measurements were performed initially and planned to repeat in annual campaigns in order to maintain NNSS certification. PDP sources and a PDP sludge drum as well as Eu-152 line sources and a spiral sludge drum were used for the measurements. In all cases, the results for accuracy and precision (%R and %RSD, respectively) were within allowable ranges as defined by the WIPP PDP program. LLD (or MDC) results were established for all the ten WIPP reportable radionuclides and U-235, and the MDC for Pu-239 was established in all cases to be well under 100 nCi/g. Useful results for reducing estimated uncertainties were established and an interesting unexpected case of high bias was observed and will be applied toward this end. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decontamination of Irradiated Nuclear Graphite Using High Temperature Molten Salt - 17447

Irradiated graphite is one of the most significant, large volume waste streams in the UK. After shut down of gas cooled reactors there will be ∼96,000 tonnes of nuclear graphite arising from pressure vessels, sealed or unsealed stacks, temporary surface storage and in silos, which may account for up to 30% by ILW volume of any future UK geological disposal facility. High temperature molten salt treatment (HMST) could be considered as a partitioning process of the activation and fission products from irradiated graphite. The main objective of the research is to optimize a specific graphite treatment technology compatible with older, current and future reactors to provide a safe and effective process to decontaminate graphite and reduce the waste inventory. In order to reach that purpose principal radionuclides contained in irradiated samples from Magnox reactors were investigated by germanium (Ge) gamma spectrometry. The next key tasks were to employ treatment at 450 deg. C in LiCl-KCl eutectic which included the following procedures: electrochemical cleaning of the salt, initial cyclic voltammetry (CV) of graphite followed by several steps of chrono-potentiometry (CP) with different current applied and CV was taken after each step. Once the treatment was established, experiments investigating the electro-refinement of the resultant salt mixtures were conducted as well as the comparison of gamma spectroscopy results of graphite before and after the treatment providing the result of total activity reduction of around 60%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benchmarking of activation rate in special core in LR-0 reactor

The experiments focused on the determination of activation reaction rates of selected IRDFF materials activated in a well-defined special core assembled in the LR-0 reactor are presented in the paper. The used core is designed and verified for IRDFF library testing by reactivity characterization, fission rates distribution and also neutron spectra measurement at the center of the core. {sup 23}Na(n,2n), {sup 75}As(n,2n), {sup 89}Y(n,2n) and {sup 90}Zr(n,2n) reaction cross sections were measured in this special core. The presented neutron cross sections were derived from experimentally determined reaction rates of irradiated samples of NaF, As{sub 2}O{sub 3}, Y{sub 2}O{sub 3}, and ZrO{sub 2}. These reaction rates are derived from gamma activities of the activation products of studied activation reactions. Net Peak Areas (NPA) of photons accompanying decay were measured using a semiconductor High Purity Germanium (HPGe) detector. Despite the fact that mentioned reactions have a threshold above 10 MeV, where the neutron spectrum in the special LR-0 core is nearly undistinguishable from {sup 235}U prompt fission neutron spectrum, the measured integral cross sections averaged in LR-0 spectrum were corrected for spectral shift. The obtained values of {sup 235}U spectral average cross section are: (3.84 ± 0.19) μb for {sup 23}Na(n,2n); (0.320 ± 0.015) mb for {sup 75}As(n,2n); (0.171 ± 0.006) mb for {sup 89}Y(n,2n); (0.107 ± 0.005) mb for {sup 90}Zr(n,2n). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of NORM in an Urban Environment using HPGe Measurements and MCNP6 Simulations

This work is part of a larger project aimed at producing an operationally relevant, validated simulation environment that can be used as a 'virtual testbed' for counterterrorism and counterproliferation efforts. Examples of such efforts include searches for illicit radiation sources before and during large special events, such as the presidential nominating conventions, inaugurations, and large sporting events. Once validated by laboratory and field measurements, this testbed can be used to test and validate algorithms and detector systems designed for various search missions in an urban environment. The detection of radioactive sources in a city is greatly complicated by natural background radiation, which emanates from various materials common to an urban environment, such as roadways, sidewalks, and building exteriors. The methods and results offered here represent the conclusion of an effort to characterize the concentration of naturally occurring radioactive material (NORM) in various elements in a controlled, but representative, urban environment. Some of the methods discussed in previous work will be briefly reiterated here, but more detail can be found in the preceding work. The location chosen for this effort was a Military Operations on Urban Terrain (MOUT) environment at the Fort Indiantown Gap (FTIG) National Guard training facility in Pennsylvania. This site was chosen because it replicates a small town where traffic and pedestrian access could be easily controlled, as to not interfere with the background measurements. This endeavor involved over 70 measurements using a high-purity germanium (HPGe) detector designed to ascertain the NORM concentrations in the soil, asphalt roads, gravel lots, concrete intersections, sidewalks, foundations, and walls found throughout the site. The NORM concentrations determined from this work will be incorporated into a large-scale simulation that can be used to investigate various search techniques and algorithms, detector types and setups, and to produce representative synthetic data for future work.

07 ISOTOPE AND RADIATION SOURCES↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Fission Product Monitoring of TRISO Coated Fuel For The Advanced Gas Reactor -1 Experiment

The US Department of Energy has embarked on a series of tests of TRISO-coated particle reactor fuel intended for use in the Very High Temperature Reactor (VHTR) as part of the Advanced Gas Reactor (AGR) program. The AGR-1 TRISO fuel experiment, currently underway, is the first in a series of eight fuel tests planned for irradiation in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). The AGR-1 experiment reached a peak compact averaged burn up of 9% FIMA with no known TRISO fuel particle failures in March 2008. The burnup goal for the majority of the fuel compacts is to have a compact averaged burnup greater than 18% FIMA and a minimum compact averaged burnup of 14% FIMA. At the INL the TRISO fuel in the AGR-1 experiment is closely monitored while it is being irradiated in the ATR. The effluent monitoring system used for the AGR-1 fuel is the Fission Product Monitoring System (FPMS). The FPMS is a valuable tool that provides near real-time data indicative of the AGR-1 test fuel performance and incorporates both high-purity germanium (HPGe) gamma-ray spectrometers and sodium iodide [NaI(Tl)] scintillation detector-based gross radiation monitors. To quantify the fuel performance, release-to-birth ratios (R/B’s) of radioactive fission gases are computed. The gamma-ray spectra acquired by the AGR-1 FPMS are analyzed and used to determine the released activities of specific fission gases, while a dedicated detector provides near-real time count rate information. Isotopic build up and depletion calculations provide the associated isotopic birth rates. This paper highlights the features of the FPMS, encompassing the equipment, methods and measures that enable the calculation of the release-to-birth ratios. Some preliminary results from the AGR-1 experiment are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A software package using a mesh-grid method for simulating HPGe detector efficiencies

Traditional ways of determining the absolute full-energy peak efficiencies of high-purity germanium (HPGe) detectors are often time consuming, cost prohibitive, or not feasible. A software package, KMESS (Kevin's Mesh Efficiency Simulator Software), was developed to assist in predicting these efficiencies. It uses a semiempirical mesh-grid method and works for arbitrary source shapes and counting geometries. The model assumes that any gamma-ray source shape can be treated as a large enough collection of point sources. The code is readily adaptable, has a web-based graphical front-end. and could easily be coupled to a 3D scanner. As will be shown. this software can estimate absolute full-energy peak efficiencies with good accuracy in reasonable computation times. It has applications to the field of gamma-ray spectroscopy because it is a quick and accurate way to assist in performing quantitative analyses using HPGe detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Capture Surrogate Reaction on 75As in Inverse Kinematics Using (d,p(gamma))

The {sup 75}As(d,p{gamma}) reaction in inverse kinematics as a surrogate for neutron capture was performed at Oak Ridge National Laboratory using a deuterated plastic target. The intensity of the 165 keV {gamma}-ray from {sup 76}As in coincidence with ejected protons, from exciting {sup 76}As above the neutron separation energy populating a compound state, was measured. A tight geometry of four segmented germanium clover {gamma}-ray detectors together with eight ORRUBA-type silicon-strip charged-particle detectors was used to optimize geometric acceptance. The preliminary analysis of the {sup 75}As experiment, and the efficacy and future plans of the (d,p{gamma}) surrogate campaign in inverse kinematics, are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

(n,2n) and (n,3n) cross sections of neutron-induced reactions on 150Sm for En from threshold to 35 MeV

Cross-section measurements were made of prompt discrete {gamma}-ray production as a function of incident neutron energy (E{sub n} = 1 to 35 MeV) on a {sup 150}Sm sample fo 1550 mg/cm{sup 2} of Sm{sub 2}O{sub 3} enriched to 95.6% in {sup 150}Sm. Results are compared with enhanced Hauser-Feshbach model calculations including the pre-equilibrium reactions. Energetic neutrons were delivered by the Los Alamos Neutron Science Center facility. The prompt-reaction {gamma} rays were detected with the Compton-suppressed Germanium Array for Neutron Induced Excitations (GEANIE). Incident neutron energies were determined by the time-of-flight technique. Excitation functions for thirteen individual {gamma}-rays up to E{sub x} = 0.8 MeV in {sup 149}Sm and one {gamma}-ray transition between the first excited and ground state in {sup 148}Sm were measured. Partial {gamma}-ray cross sections were calculated using GNASH, an enhanced Hauser-Feshbach statistical nuclear reaction model code, and compared with the experimental results. The particle transmission coefficients were calculated with new systematic 'global' optical model potential parameters. The coupled-channel optical model based on the soft rotor model was employed to calculate the particle transmission coefficients. The pre-equilibrium part of the spin distribution in {sup 150}Sm was calculated using the quantum mechanical theory of Feshbach, Kerman, and Koonin (FKK) and incorporated into the GNASH reaction model code. the partial cross sections for discrete {gamma}-ray cascade paths leading to the ground state in {sup 149}Sm and {sup 148}Sm have been summed (without double counting) to estimate lower limits for reaction cross sections. These lower limits are combined with Hauser-Feshbach model calculations to deduce the reaction channel cross sections. These reaction channel cross sections agree with previously measured experimental and ENDF/B-VII evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NEUTRON MULTIPLICITY AND ACTIVE WELL NEUTRON COINCIDENCE VERIFICATION MEASUREMENTS PERFORMED FOR MARCH 2009 SEMI-ANNUAL DOE INVENTORY

The Analytical Development (AD) Section field nuclear measurement group performed six 'best available technique' verification measurements to satisfy a DOE requirement instituted for the March 2009 semi-annual inventory. The requirement of (1) yielded the need for SRNL Research Operations Department Material Control & Accountability (MC&A) group to measure the Pu content of five items and the highly enrich uranium (HEU) content of two. No 14Q-qualified measurement equipment was available to satisfy the requirement. The AD field nuclear group has routinely performed the required Confirmatory Measurements for the semi-annual inventories for fifteen years using sodium iodide and high purity germanium (HpGe) {gamma}-ray pulse height analysis nondestructive assay (NDA) instruments. With appropriate {gamma}-ray acquisition modeling, the HpGe spectrometers can be used to perform verification-type quantitative assay for Pu-isotopics and HEU content. The AD nuclear NDA group is widely experienced with this type of measurement and reports content for these species in requested process control, MC&A booking, and holdup measurements assays Site-wide. However none of the AD HpGe {gamma}-ray spectrometers have been 14Q-qualified, and the requirement of reference 1 specifically excluded a {gamma}-ray PHA measurement from those it would accept for the required verification measurements. The requirement of reference 1 was a new requirement for which the Savannah River National Laboratory (SRNL) Research Operations Department (ROD) MC&A group was unprepared. The criteria for exemption from verification were: (1) isotope content below 50 grams; (2) intrinsically tamper indicating or TID sealed items which contain a Category IV quantity of material; (3) assembled components; and (4) laboratory samples. Therefore all (SRNL) Material Balance Area (MBA) items with greater than 50 grams total Pu or greater than 50 grams HEU were subject to a verification measurement. The pass/fail criteria of reference 7 stated 'The facility will report measured values, book values, and statistical control limits for the selected items to DOE SR...', and 'The site/facility operator must develop, document, and maintain measurement methods for all nuclear material on inventory'. These new requirements exceeded SRNL's experience with prior semi-annual inventory expectations, but allowed the AD nuclear field measurement group to demonstrate its excellent adaptability and superior flexibility to respond to unpredicted expectations from the DOE customer. The requirements yielded five SRNL items subject to Pu verification and two SRNL items subject to HEU verification. These items are listed and described in Table 1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Summary of Field Measurement on UF6 Cylinders Using Electro-Mechanically Cooled Systems

Measurement of the enrichment of solid state UF6 stored within large metal cylinders is a task commonly performed by plant operators and inspectors. The measurement technologies typically used range from low-resolution, high-efficiency sodium iodide detectors to high-resolution, moderate-efficiency high-purity germanium (HPGe) detectors. The technology used and methods deployed are dependent upon the material being measured, environmental conditions, time constraints, and measurement-precision requirements. Operators and inspectors typically use specially designed, HPGe detectors that are cooled with liquid nitrogen in situations where high-resolution measurements are required. However, the requirement for periodically refilling the system with liquid nitrogen makes remote usage cumbersome and slow. The task of cooling the detector reduces the available time for the inspector to perform other safeguards activities while on site. If the inspector has to reduce the count time for each selected cylinder to ensure that all preselected cylinders are measured during the inspection, the resulting measurement uncertainties may be increased, making it more difficult to detect and verify potential discrepancies in the operator's declarations. However, recent advances in electromechanically cooled HPGe detectors may provide the inspector with an improved verification tool by eliminating the need for liquid nitrogen. This report provides a summary of test results for field measurements performed using electromechanically cooled HPGe detectors on depleted, natural, and low-enriched uranium cylinders. The results of the study provide valuable information to inspectors and operators regarding the capabilities and limitations of electromechanically cooled systems based on true field-measurement conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Neutron capture surrogate reaction on 75As in inverse kinematics using (d,p )

The 75As(d,p ) reaction in inverse kinematics as a surrogate for neutron capture was performed at Oak Ridge National Laboratory using a deuterated plastic target. The intensity of the 165 keV -ray from 76As in coincidence with ejected protons, from exciting 76As above the neutron separation energy populating a compound state, was measured. A tight geometry of four segmented germanium clover -ray detectors together with eight ORRUBA-type silicon-strip charged-particle detectors were used to optimize geometric acceptance. The preliminary analysis of the 75As experiment and the ecacy and future plans of the (d,p ) surrogate campaign in inverse kinematics are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strained-Si/SiGe enhancement mode structures for quantum computing.

Silicon is an ideal system for investigating single electron or isolated donor spins for quantum computation, due to long spin coherence times. Enhancement mode strained-silicon/silicon germanium (sSi/SiGe) devices would offer an as-yet untried path toward electron or electron/donor quantum dot systems. Thin, undoped SiGe dielectrics allow tight electrostatic confinement, as well as potential Lande g-factor engineered spin manipulation. In this talk we summarize recent progress toward sSi/SiGe enhancement mode devices on sSi on insulator, including characterization with X-ray diffraction and atomic force microscopy, as well as challenges faced and progress on integration of either top-down and bottom-up donor placement approaches in a sSi/SiGe enhancement mode structure.

36 MATERIALS SCIENCE↗

A Mechanically-Cooled, Highly-Portable, HPGe-Based, Coded-Aperture Gamma-Ray Imager

Coded-aperture gamma-ray imaging is a mature technology that is capable of providing accurate and quantitative images of nuclear materials. Although it is potentially of high value to the safeguards and arms-control communities, it has yet to be fully embraced by those communities. One reason for this is the limited choice, high-cost, and low efficiency of commercial instruments; while instruments made by research organizations are frequently large and / or unsuitable for field work. In this paper we present the results of a project that mates the coded-aperture imaging approach with the latest in commercially-available, position-sensitive, High Purity Germanium (HPGe) detec-tors. The instrument replaces a laboratory prototype that, was unsuitable for other than demonstra-tions. The original instrument, and the cart on which it is mounted to provide mobility and pointing capabilities, has a footprint of ~ 2/3 m x 2 m, weighs ~ 100 Kg, and requires cryogen refills every few days. In contrast, the new instrument is tripod mounted, weighs of order 25 Kg, operates with a laptop computer, and is mechanically cooled. The instrument is being used in a program that is ex-ploring the use of combined radiation and laser scanner imaging. The former provides information on the presence, location, and type of nuclear materials while the latter provides design verification information. To align the gamma-ray images with the laser scanner data, the Ge imager is fitted and aligned to a visible-light stereo imaging unit. This unit generates a locus of 3D points that can be matched to the precise laser scanner data. With this approach, the two instruments can be used completely independently at a facility, and yet the data can be accurately overlaid based on the very structures that are being measured.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Combining Measurements with Three-Dimensional Laser Scanning System and Coded Aperture Gamma-Ray Imaging System for International Safeguards Applications

Being able to verify the operator's declaration in regard to the technical design of nuclear facilities is an important aspect of every safeguards approach. In addition to visual observation, it is necessary to know if nuclear material is present or has been present in undeclared piping and ducts. The possibility of combining the results from different measurement techniques into one easily interpreted product should optimize the inspection effort and increase safeguards effectiveness. A collaborative effort to investigate the possibility of combining measurements from a three-dimensional (3D) laser scanning system and gamma-ray imaging systems is under way. The feasibility of the concept has been previously proven with different laboratory prototypes of gamma-ray imaging systems. Recently, simultaneous measurements were conducted with a new highly portable, mechanically cooled, High Purity Germanium (HPGe), coded-aperture gamma-ray imager and a 3D laser scanner in an operational facility with complex configuration and different enrichment levels and quantities of uranium. With specially designed software, data from both instruments were combined and a 3D model of the facility was generated that also identified locations of radioactive sources. This paper provides an overview of the technology, describes the measurements, discusses the various safeguards scenarios addressed, and presents results of experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct Observation of Room-Temperature Polar Ordering in Colloidal GeTe Nanocrystals

Ferroelectrics and other materials that exhibit spontaneous polar ordering have demonstrated immense promise for applications ranging from non-volatile memories to microelectromechanical systems. However, experimental evidence of polar ordering and effective synthetic strategies for accessing these materials are lacking for low-dimensional nanomaterials. Here, we demonstrate the synthesis of size-controlled nanocrystals of the polar material germanium telluride (GeTe) using colloidal chemistry and provide the first direct evidence of room-temperature polar ordering in nanocrystals less than 5 nm in size using aberration-corrected transmission electron microscopy. Synchrotron x-ray diffraction and Raman studies demonstrate a sizeable polar distortion and a reversible size-dependent polar phase transition in these nanocrystals. The stability of polar ordering in solution-processible nanomaterials suggests an economical avenue to Tbit/in2-density non-volatile memory devices and other applications.

36 MATERIALS SCIENCE↗

Van der Waals Nanowires with Continuously Variable Interlayer Twist and Twist Homojunctions

Abstract Moiré patterns at van der Waals interfaces between twisted 2D crystals give rise to distinct optoelectronic excitations, as well as, narrowly dispersive bands responsible for correlated electron phenomena. Contrasting with the conventional, mechanically stacked planar twist moirés, recent work shows twisted van der Waals interfaces spontaneously formed in nanowires of layered crystals, where Eshelby twist due to axial screw dislocations stabilizes a chiral structure with small interlayer rotation. Here, the realization of tunable twist in germanium(II) sulfide (GeS) van der Waals nanowires is reported. Tapered nanowires host continuously variable interlayer twist. Homojunctions between dislocated (chiral) and defect‐free (achiral) segments are obtained by triggering the emission of axial dislocations during growth. Measurements across such junctions, implemented here using local absorption and luminescence spectroscopy, provide a convenient tool for detecting twist effects. The results identify a versatile system for 3D twistronics, probing moiré physics, and for realizing moiré architectures without equivalent in planar systems.

Sutter, Peter↗