Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Ga-68 DOTATOC PET/CT-Guided Biopsy and Cryoablation with Autoradiography of Biopsy Specimen for Treatment of Tumor-Induced Osteomalacia

Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome caused by small benign tumors of mesenchymal origin also known as phosphaturic mesenchymal tumors mixed connective tissue variant. Excellent prognosis is expected with eradication of the culprit tumor. These small tumors are notoriously difficult to localize with conventional imaging studies; this often leads to an extensive work up and prolonged morbidity. We report a patient with clinical diagnosis of TIO whose culprit tumor was localized with Ga-68 DOTATOC PET/CT and MRI. Biopsy and cryoablation were performed under Ga-68 DOTATOC PET/CT guidance. Autoradiography of the biopsy specimen was performed and showed in situ correlation between Ga-68 DOTATOC uptake and histopathology with millimeter resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Image-Guided Screw Fixation of Bone Lesions in Cancer Patients: Double-Centre Analysis of Outcomes including Local Evolution of the Treated Focus

AimTo review outcomes and local evolution of treated lesions following percutaneous image-guided screw fixation (PIGSF) of pathological/insufficiency fractures (PF/InF) and impeding fractures (ImF) in cancer patients at two tertiary centres.Materials and methodsThirty-two consecutive patients (mean age 67.5 years; range 33–86 years) with a range of tumours and prognoses underwent PIGSF for non/minimally displaced PF/InF and ImF. Screws were placed under CT/fluoroscopy or cone-beam CT guidance, with or without cementoplasty. Clinical outcomes were assessed using a simple 4-point scale (1 = worse; 2 = stable; 3 = improved; 4 = significantly improved). Local evolution was reviewed on most recent follow-up imaging. Technical success, complications, and overall survival were evaluated.ResultsThirty-six lesions were treated with 74 screws mainly in the pelvis and femoral neck (58.2 %); including 47.2 % PF, 13.9 % InF, and 38.9 % ImF. Cementoplasty was performed in 63.9 % of the cases. Technical success was 91.6 %. Hospital stay was ≤3 days; 87.1 % of lesions were improved at 1-month follow-up; three major complications (early screw-impingement radiculopathy; accelerated coxarthrosis; late coxofemoral septic arthritis) and one minor complication were observed. Unfavourable local evolution at imaging occurred in 3/24 lesions (12.5 %) at mean 8.7-month follow-up, including poor consolidation (one case) and screw loosening (two cases, at least 1 symptomatic). There were no cases of secondary fractures.ConclusionsPIGSF is feasible for a wide range of oncologic patients, offering good short-term efficacy, acceptable complication rates, and rapid recovery. Unfavourable local evolution at imaging may be relatively frequent, and requires close clinico-radiological surveillance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Image-Guided Cryoablation of Challenging Mediastinal Lesions Using Large-Volume Hydrodissection: Technical Considerations and Outcomes

ObjectiveThis study was designed to describe the technique of percutaneous image-guided cryoablation with large-volume hydrodissection for the treatment of challenging mediastinal lesions.MethodsBetween March 2014 and June 2015, three patients (mean age 62.7 years) with four neoplastic anterior mediastinal lesions underwent five cryoablation procedures using large-volume hydrodissection. Procedures were performed under general anaesthesia using CT guidance. Lesion characteristics, hydrodissection and cryoablation data, technical success, complications, and clinical outcomes were assessed using retrospective chart review.ResultsLesions (mean size 2.7 cm; range 2–4.3 cm) were in contact with great vessels (n = 13), trachea (n = 3), and mediastinal nerves (n = 6). Hydrodissection was performed intercostally (n = 4), suprasternally (n = 2), transsternally (n = 1), or via the sternoclavicular joint (n = 1) using 1–3 spinal needles over 13.4 (range 7–26) minutes; 450 ml of dilute contrast was injected (range 300–600 ml) and increased mean lesion-collateral structure distance from 1.9 to 7.7 mm. Vulnerable mediastinal nerves were identified in four of five procedures. Technical success was 100 %, with one immediate complication (recurrent laryngeal nerve injury). Mean follow-up period was 15 months. One lesion demonstrated residual disease on restaging PET-CT and was retreated to achieve complete ablation. At last follow-up, two patients remained disease-free, and one patient developed distant disease after 1 year without local recurrence.ConclusionsCryoablation using large-volume hydrodissection is a feasible technique, enabling safe and effective treatment of challenging mediastinal lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicenter Prospective Clinical Series Evaluating Radiofrequency Ablation in the Treatment of Painful Spine Metastases

BackgroundRadiofrequency ablation (RFA) of vertebral body metastases (VBM) has been reported as safe and effective in retrospective studies. This single-arm prospective multicenter clinical study evaluates RFA in the treatment of painful VBM.MethodsFifty patients with VBM were prospectively enrolled during a 13-month period at eight US centers under an IRB-approved study. Percutaneous RFA was performed under imaging guidance with cement augmentation at the discretion of the operator. Pain, disability and quality of life were evaluated at baseline, prior to discharge, days 3, 7, 30 and 90 using the Numerical Pain Rating Scale, Oswestry Disability Index (ODI), the Functional Assessment of Cancer Therapy-General 7 (FACT-G7) and Functional Assessment of Cancer Therapy Quality-of-Life Measurement in Patients with Bone Pain (FACT-BP). Adverse events were monitored throughout this time interval.ResultsTwenty-six male and 24 female patients (mean age 61.0) underwent 69 treatments (30 thoracic and 39 lumbar). Cement augmentation was performed in 96 % of reported levels. Significant improvement in mean scores for pain, disability and cancer-specific health-related quality of life from baseline to all time intervals was seen. NRPS improved from 5.9 to 2.1 (p < 0.0001). ODI improved from 52.9 to 37.0 (p < 0.08). FACT-G7 improved form 10.9 to 16.2 (p = 0.0001). FACT-BP improved from 22.6 to 38.9 (p < 0.001). No complications related to the procedure were reported.ConclusionRFA with cement augmentation safely and effectively reduces pain and disability rapidly, while increasing quality of life in patients suffering from vertebral body metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hemorrhagic Complications of Percutaneous Cryoablation for Renal Tumors: Results from a 7-year Prospective Study

PurposeCryoablation of renal tumors is assumed to have a higher risk of hemorrhagic complications compared to other ablative modalities. Our purpose was to establish the exact risk and to identify hemorrhagic risk factors.Materials and MethodsThis IRB approved, 7-year prospective study included 261 renal cryoablations. Procedures were under conscious sedation and CT guidance. Pre- and postablation CT was obtained, and hemorrhagic complications were CTCAE tabulated. Age, gender, tumor size, histology, and probes number were tested based on averages or proportions using their exact permutation distribution. “High-risk” subgroups (those exceeding the thresholds of all variables) were tested for each variable alone, and for all combinations of variable threshold values. We compared the subgroup with the best PPV using one variable, with the subgroup with the best PPV using all variables (McNemmar test).ResultsThe hemorrhagic complication rate was 3.5 %. Four patients required transfusions, two required emergent angiograms, one required both a transfusion and angiogram, and two required bladder irrigation for outlet obstruction. Perirenal space hemorrhage was more clinically significant than elsewhere. Univariate risks were tumor size >2 cm, number of probes >2, and malignant histology (P = 0.005, 0.002, and 0.033, respectively). Multivariate analysis showed that patients >55 years with malignant tumors >2 cm requiring 2 or more probes yielded the highest PPV (7.5 %).ConclusionsAlthough older patients (>55 years old) with larger (>2 cm), malignant tumors have an increased risk of hemorrhagic complications, the low PPV does not support the routine use of embolization. Percutaneous cryoablation has a 3.5 % risk of significant hemorrhage, similar to that reported for other types of renal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiologic Placement of Uncovered Stents for the Treatment of Malignant Colonic Obstruction Proximal to the Descending Colon

PurposeTo evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon.Materials and MethodsThis was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructive symptoms or signs within 48 h of stent deployment.ResultsIn total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months.ConclusionsThe radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Injection of Blood Products Versus Gelatin Sponge as a Technique for Local Hemostasis

PurposeTo provide a method of reducing risk of minimally invasive procedures on patients with abnormal hemostasis and evaluate efficacy of direct fresh frozen plasma injection through a procedure needle tract compared to Gelfoam (gelatin sponge) administration.Materials and MethodsEighty patients with elevated international standardized ratio (INR) undergoing minimally invasive procedures using imaging guidance were selected retrospectively. Forty patients had received Gelfoam as a means of tract embolization during the procedure. The other 40 received local fresh frozen plasma (FFP) through the needle tract. The number of complications and clinically significant bleeding events were recorded. A threshold of 30 cc of blood loss after a procedure was used to identify excess bleeding.ResultsNo patients experienced clinically significant bleeding after administration of FFP. Five patients experienced postoperative drops in hemoglobin or hematomas after administration of Gelfoam.ConclusionLocal injection of blood products can reduce postprocedure bleeding in patients undergoing minimally invasive procedures and provides a safe alternative to the use of synthetic fibrin plugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The IR Evolution in Oncology: Tools, Treatments, and Guidelines

Early focus of interventional oncologists was developing tools and imaging guidance, performing “procedures” acting as a skillful technician without knowledge of clinical patient outcomes, beyond post-treatment image findings. Interventional oncologists must deliver “treatments” and not “procedures”, and focus on clinically relevant outcomes, provide clinical continuity of care, which means stand at multidisciplinary tumor boards, see patients in consultation before treatment and for follow-up. Interventional oncologists have fought for the same “market” with surgery in a head to head, bloody competition called red ocean strategy in marketing terms, resulting in many aborted trials. Wide adoption of interventional oncology is facing the challenge to build evidence with overall survival as endpoint in randomized trials while the benefits of a treatment on overall survival are diluted by the effects of possible/inevitable subsequent therapies. Because interventional oncology is a disruptive force in medicine achieving same results as others (surgery) using different, less invasive approaches, patients where surgery is irrelevant can be target with a blue ocean strategy (to propose treatment where there is no competition). Recently interventional oncology has been included in the ESMO guidelines for colorectal cancer with oligometastatic disease with both surgical resection, and thermal ablation classified in the same category called “local ablative treatments”. Interventional oncologists have to shape the future by publications in oncologic journal, by being active members of oncology scientific societies, and use modern public megaphone (blog, video sharing, …) to disseminate information and let society know that interventional is not a me-too product but a disruptive treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses

PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. After placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Self-Expandable, Radioactive Airway Stent Loaded with {sup 125}I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog

PurposeAirway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with {sup 125}I seeds in healthy beagle dog.Materials and MethodsUnder fluoroscopic guidance, forty-eight self-expandable airway stents loaded with {sup 125}I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting.ResultsAll stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of {sup 125}I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope.ConclusionsThis study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with {sup 125}I seeds in healthy beagle dog.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Visualization Using a 50/50 (Contrast Media/Glucose 5% Solution) Technique for Radioembolization as an Alternative to a Standard Sandwich Technique

BackgroundRadioembolization (RE) with {sup 90}yttrium ({sup 90}Y) resin microspheres generally employs a sandwich technique with separate sequential administration of contrast medium (CM), followed by vehicle (e.g., glucose 5% [G5] solution), then {sup 90}Y resin microspheres (in G5), then G5, and then CM again to avoid contact of CM and microspheres under fluoroscopic guidance. This study evaluates the visualization quality and safety of a modified sandwich technique with a 50/50-mixture of CM (Imeron 300) and G5 for administration of {sup 90}Y resin microspheres.Materials and MethodsA retrospective analysis of 81 RE procedures in patients with primary or secondary liver tumors was performed. The quality of angiographic visualization of the hepatic vessels was assessed before the first injection and immediately before the whole dose has been injected. Visualization and flow rate were graded on a 5-point scale: 1 = very good to 5 = not visible/no antegrade flow. Univariate logistic regression models and multiple linear regression models were used to evaluate the prognostic variables associated with visualization and flow scores.ResultsVisualization quality was inversely related to flow rate, the lower the flow rate the better the grade of the visualization. Visualization quality was also inversely related to body-mass-index (BMI). Performing RE with the 50/50-CM/G5 mixture resulted in a mean injection time for 1 GBq of 15 min. No clinically significant adverse events, including radiation-induced liver disease were reported.ConclusionRE with a 50/50-mixture of CM and G5 for administration of {sup 90}Y resin microspheres in a modified sandwich technique is a safe administration alternative and provides good visualization of hepatic vessels, which is inversely dependent on flow rate and BMI. Injection time was reduced compared with our experience with the standard sandwich technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Arterial Embolization Using Cone Beam CT with Tumor Feeding Vessel Detection Software: Impact on Hepatocellular Carcinoma Response

PurposeDedicated tumor feeding vessel detection software (TFVDS) using cone beam CT has shown a higher sensitivity to detect tumor feeding vessels during hepatic arterial embolization (HAE) of hepatocellular carcinoma (HCC) compared to 2D imaging. Our primary hypothesis was that HCC tumors treated with HAE guided by a TFVDS would show more complete response (CR) than when treated with 2D imaging alone. Secondary analysis of the impact on X-ray exposure was performed.Materials and MethodsNineteen males and 8 females (median age: 69 year, 46–85) with 44 tumors (median size: 38 mm, 6–100) treated with selective HAE between January 2013 and December 2014 were included. Exclusion criteria were: extra-hepatic supply, >4 tumors, tumor size >10 cm, and adjunctive local therapy. Baseline patient and procedure characteristics were reviewed. Differences in CR per modified Response Evaluation Criteria in Solid Tumors were assessed by univariate and multivariate analyses for tumor size, number, location, particles size, and use of TFVDS.ResultsMedian imaging follow-up was 20.1 months (2–33). Use of TFVDS (13 patients, 19 tumors) was the only factor predictive of CR (OR = 3.85 [CI95%: 1.09, 13.67], p = 0.04) on univariate analysis but not on multivariate analysis (OR = 3.26 [0.87, 12.23], p = 0.08). A higher rate of CR was observed for HAE using TFVDS guidance versus 2D imaging alone (68.4%, 13–19, vs. 36%, 9–25, p = 0.03). Median dose area product was lower when TFVDS was used (149.7 Gy.cm{sup 2}, 38–365, vs. 227.8 Gy.cm{sup 2}, 85.3–468.6, p = 0.05).ConclusionsHCC embolized with TFVDS may result in improved local tumor response without increasing the dose exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Particle Imaging Guided Real-Time Percutaneous Transluminal Angioplasty in a Phantom Model

PurposeTo investigate the potential of real-time magnetic particle imaging (MPI) to guide percutaneous transluminal angioplasty (PTA) of vascular stenoses in a phantom model.Materials and MethodsExperiments were conducted on a custom-built MPI scanner. Vascular stenosis phantoms consisted of polyvinyl chloride tubes (inner diameter 8 mm) prepared with a centrally aligned cable tie to form ~ 50% stenoses. MPI angiography for visualization of stenoses was performed using the superparamagnetic iron oxide nanoparticle-based contrast agent Ferucarbotran (10 mmol (Fe)/l). Balloon catheters and guidewires for PTA were visualized using custom-made lacquer markers based on Ferucarbotran. Stenosis dilation (n = 3) was performed by manually inflating the PTA balloon with diluted Ferucarbotran. An online reconstruction framework was implemented for real-time imaging with very short latency time.ResultsVisualization of stenosis phantoms and guidance of interventional instruments in real-time (4 frames/s, ~ 100 ms latency time) was possible using an online reconstruction algorithm. Labeling of guidewires and balloon catheters allowed for precise visualization of instrument positions.ConclusionReal-time MPI-guided PTA in a phantom model is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Interventional Radiology (IR) Gender Gap: A Prospective Online Survey by the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)

AimA prospective online survey was conducted by the Cardiovascular Interventional Radiological Society of Europe (CIRSE) to evaluate the gender gap within interventional radiology (IR) and the barriers facing women in IR.Materials and MethodsA questionnaire (“Appendix”) was devised by the authors and the CIRSE communication and publication team and sent electronically to 750 identifiable female members of CIRSE. Responses were collected from 7 August to 24 August 2017.ResultsThe response rate was 19.9% (n = 149) with highest responses from UK (18%), Italy (11%), Germany (11%), Spain (7%), Netherlands (5%), France (5%), Sweden (4%), USA (4%). 91% of the respondents were between 31 and 46 years, 83% work full time, 62% spend > 50% of their working time in IR, and 67% practice in a university or tertiary referral institution. 85% were in the minority in their department. 52% had no leadership role in their department, but 67% expressed willingness to consider a leadership position. Their main concerns were work/family life balance, the risks of radiation exposure, the effect of pregnancy on training and practice and the male-dominated work environment.ConclusionThis survey highlights issues experienced by women in IR. Clear guidance on concerns regarding radiation exposure particularly during pregnancy is needed. Structured and supportive training is required for female IRs who may wish to train or work flexibly. The male-dominated environment is discouraging, and a scheme to promote female IRs would encourage women to take on senior leadership positions and attract more women into the specialty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted CBCT-Guided Needle Insertions: Preliminary Results in a Phantom Model

Aim: To compare robotic-assisted needle insertions performed under CBCT guidance to standard manual needle insertions. Materials and Methods: A homemade robotic prototype was used by two operators to perform robotic and manual needle insertions on a custom-made phantom. Both the operators had no experience with the prototype before starting the trial. The primary endpoint was accuracy (i.e., the minimal distance between the needle tip and the center of the target) between robotic and manual insertions. Secondary endpoints included total procedure time and operators’ radiation exposure. The Wilcoxon test was used. A p value less than 0.05 was considered statistically significant. Results: Thirty-three (17 manual, 16 robotic) needle insertions were performed. Mean accuracy for robotic insertion was 2.3 ± 0.9 mm (median 2.1; range 0.8–4.2) versus 2.3 ± 1 mm (median 2.1; range 0.7–4.4) for manual insertion (p = 0.84). Mean procedure time was 683 ± 57 s (median 670; range 611–849) for the robotic group versus 552 ± 40 s (median 548; range 486–621) for the manual group (p = 0.0002). Mean radiation exposure was 3.25 times less for the robotic insertion on comparison to manual insertion for the operator 1 (0.4 vs 1.3 µGy); and 4.15 times less for the operator 2 (1.9 vs 7.9 µGy). Conclusion: The tested robotic prototype showed accuracy comparable to that achieved with manual punctures coupled to a significant reduction of operators’ radiation exposure. Further, in vivo studies are necessary to confirm the efficiency of the system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗