Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fossil Fuel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Testing- and Model- Based Optimization of Coal-fired Primary Heater Design for Indirect Supercritical CO 2 Power Cycles (Final Scientific and Technical Report)

The overall objective of this project was to perform the R&D necessary to mitigate the risk associated with the design of a primary heat exchanger for a solid-fired combustion system coupled with an indirect-fired closed-loop Brayton Cycle utilizing supercritical CO 2 . The key technological hurdle was the coupling of a solid-fuel firing system with the primary heater, which poses a singular challenge, which is the management of burner performance and operational conditions in a way to manage heat exchanger tube metal temperatures and temperature ramp rates in the absence of fluid phase change on the inside of the tubes. We designed and built the first ever pseudo power system employing a simple recuperated supercritical CO 2 closed-loop Brayton Cycle coupled to a solid-fuel fired system. Advanced coupled CFD and process modeling were used to design the primary heat exchanger (PHX), which consisted of both radiative and convective sections, to limit tube metal temperatures resulting from the heat release profile of the solid fuel flame near the radiative tubes. The heat exchanger was designed to produce finished CO 2 temperatures of 600 °C a pressure of 20.7 MPa and CO 2 flow of 5.5 kg/s. The constructed PHX was capable of 1.2 MWth heat uptake. During design of the PHX, the modeling showed that most variables influencing flame shape (burner stoichiometric ratio and register velocities and swirl) were not suitable to manage heat flux to the metal surfaces. This is because they substantially increased adiabatic flame temperature through the influence of localized stoichiometric ratio. Excess air and firing rate were the two most powerful variables that could be used to control tube surface temperatures. The coupled system was operated for a total of 407 hours, with the longest continuous run of 248 hours. For 62% of the operational time, the unit was unmanned and in automatic control. The fuels used for the testing included natural gas, two Utah Bituminous coals, woody biomass, and bagasse. During the testing we were able to verify the 1.2 MWth heat uptake and we operated at a finished CO 2 temperature of 607 °C and a pressure of 20.3 MPa simultaneously. The real-time corrosion rate of the Super 304H tube CO 2 surface in the region of the radiative section of the PHX were measured, at an approximate temperature of 550 °C. The two key variables related to corrosion rate are the pressure and flow rate of the CO 2 . A technoeconomic analysis was performed at a scale of 120 MWE. The updated analysis showed that the efficiency of an sCO 2 power producing plant will be related to the pressure drop of the PHX.

01 COAL, LIGNITE, AND PEAT↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This National Energy Technology Laboratory (NETL) study addresses the conceptual design of greenfield pulverized coal (PC) plants intended for flexible rather than high capacity factor baseload operation. The United States has plentiful, low-cost natural gas resources - studies of aggressive decarbonization scenarios of the US energy sector suggest that the variability of carbon-free power can be economically addressed using dispatchable natural gas-fueled generation. Globally, natural gas resources are not as plentiful or low cost; consequently, some regions of the world are anticipated to continue to rely upon coal generation, even as they pursue decarbonization efforts. To support the increased utilization of variable renewable generation in these coal-dependent regions, plant designs must target low-capacity factor coal plants with increased emphasis on flexibility attributes such as start-up times, ramp rates, minimum load, and part-load heat rates. While much work has been performed on the improvement of the flexibility for existing coal plants originally designed for baseload service, little public literature exists on clean sheet design for flexible operation. This conceptual design study aims to define the features, performance characteristics, and costs for greenfield coal plants intended for flexible operation. Quantifying these characteristics provides critical information required by utility owners, grid planners, energy market modelers, and energy policy decision makers in coal-dependent regions of the world to better understand how coal-fired power plants can support a transition to low carbon generation.

20 FOSSIL-FUELED POWER PLANTS↗

Multi-Constituent Airborne Contaminants Capture with Low Cost Oxide Getters and Mitigation of Cathode Poisoning in Solid Oxide Fuel Cell

The technical effort and scientific findings, discussed in this report, documents operational barriers and associated long term performance stability challenges posed by the presence of trace airborne multi-constituent contaminants present in high-temperature electrochemical systems, including Solid Oxide Fuel Cells (SOFCs), Solid Oxide Electrolysis Cells (SOECs), Ion Transport Membranes, and Gas Separation systems. Above systems, offering promises for cleanliness and energy efficiency, face challenges with electrode poisoning stemming from the presence of trace contaminants including gaseous Cr/B/Si vapors in the presence of intrinsic contaminants SO 2 /CO 2 /H 2 O gases. The study indicates that the long-term electrical performance degradation in SOFC systems can be traced to electrochemical, structural, and mechanical changes across cell, stack, and balance of plant components resulting from interactions with trace contaminants leading to increase in both ohmic and non-ohmic polarizations. The degradation primarily results from solid-state and gas-phase materials migration, electrode poisoning, and interactions at the cell and stack levels. Cathode degradation emerges as a significant factor impacting overall SOFC performance, especially related to the presence of intrinsic and extrinsic airborne impurities such as SOx, CrOx(OH)y, SOx, Si(OH)x, and HBOx. Although at trace levels, prolong systems operation at higher airflow (3-10X stoichiometric) allow the accumulation of contaminants within the cell components leading to electrical performance degradation through poisoning and electrode deactivation.

20 FOSSIL-FUELED POWER PLANTS↗

SECARB 2020 Semi-Annual Field Review Reports - Anthropogenic Test

The Southern States Energy Board (SSEB) managed the overall Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III project and the Electric Power Research Institute (EPRI) managed all activities associated with the Anthropogenic Test site. Advanced Resources International, Inc. (ARI) assisted EPRI with the management of site activities. EPRI and ARI followed reporting procedures that included monthly and quarterly technical progress reports, as well as periodic reporting on key field activities. Subsequent sections of this report catalog the field activities and are organized in a semi-annual chronology. The SECARB Anthropogenic Test was the largest demonstration of a fully integrated, pulverized coal-fueled carbon capture and storage (CCS) project in the United States as of 2012 and supports a commercial prototype of CO 2 capture; transportation; subsurface storage; and monitoring, verification, and accounting (MVA); and assessment. The demonstration-scale, post-combustion CO 2 capture facility at Alabama Power Company’s Plant Barry diverted flue gas (25MW equivalent) from its Unit #5 coal burning facility and captured the CO 2 using Mitsubishi Heavy Industries (MHI) KM-CDRTM advanced amine technology. The captured CO2 was compressed at Plant Barry and transported by pipeline to the injection location southeast of Citronelle, Alabama. The Citronelle Project’s geologic storage and MVA sites were located on the flanks of the Citronelle Dome, approximately three miles southeast of the city of Citronelle. The injection zone, the Paluxy Formation, a saline formation that occurs at approximately 9,400 feet and overlies the oil production horizon of the Citronelle oilfield, presents a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The confining zone, the basal shale of the overlying Washita-Fredericksburg Formation, is persistent throughout the Citronelle area and possesses the appropriate criteria to act as an effective CO 2 seal.

01 COAL, LIGNITE, AND PEAT↗

Advanced Anti-Fouling Coatings to Improve the Efficiency of Coal Power Plants

As the total cost of carbon to generate energy has become a global concern, operators are increasingly looking at all parts of the generation cycle to find areas where efficiency gains may be found. It has been long identified that fouling of heat exchangers is a persistent cause of up to 2.5% of global CO 2 emissions. Unfortunately, practice has also demonstrated that unless a powerful economic driver exists to encourage preemptive mitigation of fouling, there will always be a strong tendency for operators to minimize any form of intervention due to high costs and challenges in scheduling downtime. The objective of this proposed research effort was to demonstrate how existing power plants could lower their carbon emissions and significantly improve heat transfer efficiency using new surface treatment materials to control fouling in a variety of heat exchange equipment. The surface treatment material which was optimized and deployed in this effort is now known commercially as HeatX. It is a low-surface energy, water- and oil-repellent, abrasion resistant material which can be applied in-situ to a wide variety of previously worn/used/in-service substrates. Once applied, it provides a barrier against corrosion, scale deposit formation, and biofilm adhesion on the circulating water-containing tube-side. Alternatively, if applied to the tube exterior, the non-wetting nature of the surface was demonstrated to promote dropwise condensation, subsequently lowering condenser backpressure and increasing overall plant efficiency. As part of this cooperative effort, the Department of Energy’s support was crucial to de-risk and demonstrate the concept of HeatX, while validating both the performance and economic benefit in multiple pilot field studies. The HeatX material properties were optimized in this effort for full field applicability to heat exchangers and condensers, and Oceanit developed the necessary procedures and protocols to provide enough material to support extended length, multi-year demonstrations in the power generation, desalination, and refining industries, making this technology broadly applicable and ready for commercial transition. Field deployment case studies at thermal power plants have shown that the HeatX treatment can provide economic savings of up to $15,000 per day for an operator based on avoiding maintenance costs and lowering fuel usage. The complete mitigation of fouling effects can increase the efficiency of equipment by up to 7%, in a field where gains of 0.5% are generally seen as operationally significant. The HeatX treatment has also demonstrated exceptional lifetime and compatibility with a wide variety of seawater and hydrocarbon environments, further increasing both the return on investment and the effective emission reduction. Such efficiency improvements correlate to massive carbon savings. For every 1 GW of capacity, operators can see carbon emissions reductions of 300,000 tons of CO 2 per year. When looking at the bigger picture, improved condenser function across the U.S. has the potential to prevent 221.3 million tons of CO 2 emissions, equivalent to the sequestration capacity of 129 million acres of forest. If applied on a global scale, 1.26 billion metric tons of CO 2 could be averted from the atmosphere, the same amount of carbon sequestrated by 1.5 billion acres of forest annually or 262,000 wind turbines operating annually. As businesses across multiple industries take a more active role in focusing on environmental, social, and governance (ESG) solutions as part of their core business operations, HeatX will be an attractive technology for commercial investment.

01 COAL, LIGNITE, AND PEAT↗

A Study of Propane Combustion in a Spark-Ignited Cooperative Fuel Research (CFR) Engine

Liquefied petroleum gas (LPG), whose primary composition is propane, is a promising candidate for heavy-duty vehicle applications as a diesel fuel alternative due to its CO 2 reduction potential and high knock resistance. To realize diesel-like efficiencies, spark-ignited LPG engines are proposed to operate near knock-limit over a wide range of operating conditions, which necessitates an investigation of fuel-engine interactions that leads to end-gas autoignition with propane combustion. This work presents both experimental and numerical studies of stoichiometric propane combustion in a sparkignited (SI) cooperative fuel research (CFR) engine. Engine experiments are initially conducted at different compression ratio (CR) values, and the effects of CR on engine combustion are characterized. A three-pressure analysis (TPA) model based on the two-zone combustion concept is developed in GT-Power and validated using test results to estimate in-cylinder wall temperatures, residual gas fraction, etc. This model is further utilized to examine end-gas chemistry by enabling the SI turbulent flame combustion and unburned gas chemical kinetics modules. Finally, a three-dimensional (3D) computational fluid dynamic (CFD) model of the CFR engine is developed in CONVERGE, where the G-equation and SAGE detailed chemical kinetics models are implemented for combustion modeling. Here, a 153 species reduced chemical kinetics mechanism derived from the detailed NUIGMech1.1 mechanism based on the ignition delay and laminar flame speed (LFS) studies is used to generate an LFS lookup table and to describe end-gas autoignition chemistry. Multi-cycle Reynolds-averaged Navier-Stokes (RANS) simulations are then performed for the tested CRs, and the numerical model is shown to be capable of predicting the propane combustion characteristics, particularly the end-gas autoignition behavior.

20 FOSSIL-FUELED POWER PLANTS↗

cerf: A Python package to evaluate the feasibility and costs of power plant siting for alternative futures

Long-term electric power sector planning and capacity expansion is a key area of interest to stakeholders across a wide range of organizations because it helps in making informed decisions about investments in infrastructure within the context of potential future vulnerabilities under various natural and human stressors. Future power plant siting costs will depend on a number of factors including the characteristics of the electricity capacity expansion and electricity demand (e.g., fuel mix of future electric power capacity, and the magnitude and geographic distribution of electricity demand growth) as well as the geographic location of power plants. Electricity technology capacity expansion plans modeled to represent alternate future conditions meeting a set of scenario assumptions are traditionally compared against historical trends which may not be consistent with current and future conditions. We present the `cerf` Python package (a.k.a., the Capacity Expansion Regional Feasibility model) which helps evaluate the feasibility and structure of future, scenario-driven electricity capacity expansion plans by siting power plants in areas that have been deemed the least cost option while considering dynamic future conditions. We can use `cerf` to gain insight to research topics such as: 1) under what conditions future projected electricity expansion plans from models such as GCAM-USA are possible to achieve, 2) where and which on-the-ground barriers to siting (e.g., protected areas, cooling water availability) may influence our ability to achieve certain expansions, and 3) how electricity infrastructure build-outs and value may evolve into the future when considering locational marginal pricing (LMP) based on the supply and demand of electricity from a grid operations model.

20 FOSSIL-FUELED POWER PLANTS↗

Intensified Catalytic Conversion of CO2 into High Value Chemicals

The utilization of CO2 produced from power generation plants as a feedstock for creating new valuable products offers a strategy to reduce GHG emissions, offset carbon capture costs, and facilitate the rebalancing of the carbon cycle. After considering the thermodynamic requirement of potential products from CO2 utilization and their market size, formic acid is a desirable target that offers widespread utility in industrial chemical production and chemical energy storage as a liquid fuel. To effectively utilize CO2 from power generation plants, UK proposes an enhanced bimetallic oxide carbon utilization process (EBOCU) that enables electrochemical CO2 conversion to formic acid. The UK intensified electrocatalytic process combines three main components: 1) a novel bimetallic oxide electrocatalyst; 2) a stable electrochemical reactor using robust electrodes; and 3) a pressurized electrochemical reactor. The output from this project showed the economic viability of producing high-value formic acid from CO2 to both offset the cost associated with post-combustion CCS and reduce GHG emissions. This project developed and screened a series engineered catalysts to selectively reduce CO2 directly to formic acid. The best performing catalyst based on formic acid production, stability, and Faradaic efficiency, was immobilized on carbon electrodes, and tested inside a flow through reactor. After lab-scale testing was completed, the experimental data was used to perform a Life-Cycle Analysis (LCA) and conduct an Initial Technical and Economic Feasibility Study. The LCA showed a pathway to a net negative CO2 utilization process with the incorporation of renewable energy, while the TEA showed the potential to produce formic acid below the current commercial price. The UK EBOCU process was successfully demonstrated at the TRL3 level and has a clear pathway to further development and contribution to the nation’s ambitious decarbonization goals.

20 FOSSIL-FUELED POWER PLANTS↗

Controlling pollutant emissions in a high-pressure combustor with fuel-diluent blending

This paper investigates the formation of nitric oxide (NO) and carbon monoxide (CO) emissions as a function of nitrogen (N 2 ) or carbon dioxide (CO 2 ) diluent content, added to a premixed reacting jet in crossflow. Here, reaction characteristics of a rich methane-air jet injected into a lean vitiated crossflow were analyzed at an elevated pressure of 5 atm. The jet was pre-heated and enriched with 0%, 15%, 30%, and 50% mass fraction to quantify the effect on pollutant emissions. Simulated results of the full chemistry Star-CCM+CFD model were verified with data taken in the experimental high-pressure combustion facility, which provides pressure, temperature and velocity profiles, as well as line-of-sight chemiluminescence and exit emission measurements. The analysis revealed the significant influence of the diluent to delay axial combustion; this mixing delay increased the axial flame lift-off and controlled any thermal ignition limitations. Increasing the diluent content increased the timescale for the flame to stabilize, which allowed for greater entrainment of crossflow oxidizer into the axial jet stream, and led to decreased pollutant emissions. Hence, crossflow entrainment is a critical driving force at high diluent content. Local nitric oxide (NO) emission formation in the axial stage was predicted numerically, showing the correlation between diluent addition, axial heat release, and the formation of nitric oxide pollution. The high diluent levels leaned out the jet mixture and delayed axial combustion, while reducing prompt and thermal NOx by mitigating flame hotspots and minimizing the timescale that the products remain at high temperatures.

03 NATURAL GAS↗

Techno-Economic Analysis and Life Cycle Assessment of Alternative Fuels for Locomotives in the U.S. Freight Rail Sector

Freight rail is more energy-efficient than truck transport over long-haul distances, offering a low-energy and emissions-intensive option for transporting freight. This study evaluates techno-economic analysis and life cycle assessment of seven alternative unblended fuels for freight locomotive engines─biodiesel, renewable diesel (RD), bio-oils, methanol, dimethyl ether (DME), ethanol, and ammonia─across 16 fuel pathways utilizing soybean, corn, woody biomass, renewable hydrogen, and waste sources, e.g., sludge, manure, and industrial CO 2 , and compares these to conventional diesel. The minimum fuel selling price (MFSP) ranged from $\$2.05$ to $\$8.27$ per diesel gallon equivalent (2020 US dollars), with biocrude and RDs produced from hydrothermal liquefaction (HTL) of sludge having the lowest MFSPs due to coproduct credits and avoided waste treatment cost. Life cycle GHG emissions ranged from −41 to 53 g of CO 2 e/MJ. RD from waste via HTL achieves negative emissions by diverting sludge/manure from GHG-intensive conventional management. Few pathways such as biocrude, methanol, and DME require additional control for SO X emissions in the refinery, while ethanol, FT-diesel, and bio-oil require additional control for particulate matter emissions. Bio-oil and RD from sludge have lower marginal abatement cost or MAC (–$\$38$/tonne CO 2 lowest) while methanol and ammonia with renewable hydrogen have higher MAC ($\$490$/tonne CO 2 maximum).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Biomass Combustion in a Circulating Fluidized Bed Combustor

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has skyrocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing resulting in higher combustion efficiency and the ability to use lower quality fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions. SO 2 emissions are conveniently controlled through the addition of Ca-based sulphur sorbents within the combustor. This report summarizes the current modeling effort on a 50 kW th CFB combustor with a diameter of 10 cm and a height of 5 m; designed, built, and operated at CanmetENERGY in Ottawa, Canada employing the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The MFiX-PIC model parameters for the simulation are tuned against cold-flow experiments from CanmetENERGY using 9 kg of olivine sand as the inert bed material. It is shown that for the relatively coarse fluid meshes and large parcel sizes necessitated by the scale of the simulation, filter size dependent corrections to the drag law must be incorporated to ensure accuracy of the simulation results. The validated cold flow model is extended to simulate reacting flow with torrefied hardwood as the feedstock and to validate the combustion reaction scheme. The species concentrations at the riser outlet are compared against CanmetENERGY’s experiments and show satisfactory agreement. The simulations demonstrate the ability of MFiX-PIC to accurately capture the physics and chemistry of a circulating fluidized bed combustor at bench scales, which can be further extended to pilot- and industrial-scale systems.

20 FOSSIL-FUELED POWER PLANTS↗

Wet Waste Hydrothermal Liquefaction and Biocrude Upgrading to Hydrocarbon Fuels: 2020 State of Technology

Data from Pacific Northwest National Laboratory’s conversion hydrothermal liquefaction (HTL) program for wet waste was used to update the pathway techno-economic analysis (TEA) for the fiscal year 2020 State of Technology (2020 SOT). The modeled fuel blendstock MFSP for the 2020 SOT is estimated at $4.50/GGE (with ammonia stripping of the AP), a reduction of $0.61/GGE, or 12%, relative to the 2019 SOT (Snowden-Swan et al. 2020). Progress in the HTL area includes increased reactor LHSV from 3.6 to 4.0 and a newly designed staged approach for the sludge pumping and heating, resulting in a 1 cent and 26 cent reduction in modeled MFSP, respectively. The newly designed heat exchanger configuration is less material and capital intensive than the previous SOT, and provides a system design that is more scalable with regard to practical fabrication limitations. Further improvements may be possible with the use of core inserts to enhance tube velocity and heat transfer rates. Biocrude hydrotreating research progress improved weight hourly space velocity (WHSV) from 0.67 to 0.72 hr-1 in the guard bed and from 0.39 to 1.02 hr-1 in the main hydrotreating bed, a 7% and 162% improvement, respectively. Hydrotreating performance was not sacrificed at the higher throughput rates and catalyst activity remained stable over the run. The demonstrated increase in WHSVs reduced the modeled MFSP by $0.34/GGE.

20 FOSSIL-FUELED POWER PLANTS↗

Integrated Turbine Component Cooling Designs Facilitated by Additive Manufacturing and Optimization

This research program involved the development of improved gas turbine cooling by optimizing the combined internal and film cooling configurations used for turbine blades and vanes. Improved cooling of turbine airfoils allows the gas turbines to be operated at higher temperatures which improves efficiency for gas turbine-based power generation. This also facilitates operation with hydrogen-based fuels which inherently generate higher operating temperatures. Designs of the new cooling configurations were based on the added geometric flexibility that is available when using metal additive manufacturing techniques. When making these designs, adjustments were made to account for imperfections occurring in the metal additive manufacturing process. New designs for film cooling holes were developed using computational adjoint gradient optimization techniques which generated a unique film cooling hole with 70% greater film cooling effectiveness compared to conventional shaped film cooling holes. A major factor in improving the film cooling effectiveness were small external protrusions on either side of the new hole which generated vortices that pushed coolant towards the surface and increased the lateral spreading of the coolant. Our studies also included optimization of film cooling holes that can be built with conventional manufacturing techniques and optimizing the internal coolant channels that supply coolant to the film cooling holes. Various internal coolant channel shapes were investigated and designs that maximized the cooling of the airfoil while minimizing pressure losses in the channel flows were identified. Testing and verification of the performance of the final configurations was done with a transonic wind tunnel facility which allowed testing at engine realistic high velocities. Final testing of the combined internal and film cooling configurations was done by incorporating the configurations in Penn State’s National Experimental Turbine (NExT) vane. These tests confirmed the enhanced overall cooling effectiveness provided by the new cooling configuration designs.

03 NATURAL GAS↗

Developing Accelerated Test Protocols and Tuning Microstructures of the Common Materials to Improve Robustness, Reliability, and Endurance of SOFC Cells

This work is built on our prior work where we found that phase transformation in praseodymium nickelates, e.g. Pr 2 NiO 4 (PNO) and (Pr 1-x Nd x ) 2 NiO 4 (PNNO), can be electrochemically driven, and is substantially faster when compared to thermal annealing studies. The first task aims at an attempt to further accelerate the phase transformation in the oxygen electrode by alternating the current input in the cells, which lead to the development of accelerated test protocols (ATPs). ATPs showed up to 60x faster phase transformation and up to 10x faster performance degradation in (Pr 0.50 Nd 0.50 ) 2 NiO 4 electrodes, when compared to long-term operation under constant current density. Furthermore, the phase stable Nd 2 NiO 4 and (La 0.6 Sr 0.4 )(Co 0.8 Fe 0.2 )O 3 (LSCF6482) electrodes were tested in full cells under ATPs, and showed up to 10x faster performance degradation within 1,100 hours in a comparison with long-term thermal annealing studies and electrochemical operation under constant current density. The second task aims at the quantification of the contributions of cell components to the total impedance of a solid oxide fuel cell (SOFC) using electrochemical impedance spectroscopy (EIS) and distribution of relaxation times (DRT). Specifically, the role of gas composition at both anode and cathode was systematically studied, aiming at deconvoluting, identifying and quantifying the contributions of different electrode processes. This was achieved by first tuning the partial pressure of H 2 at the anode and subsequently varying the partial pressure of O 2 at the cathode. The results suggest that, while DRT offers a viable way of deconvoluting different times distributions, additional attention is needed before assigning a peak to a specific electrode process due to the significant overlap of the contributions from the cathode and the anode. Density function theory studies show that both Pr-vacancies and O-defects play a key role on the activity and stability for nickelates towards oxygen reduction reaction. The resident O-interstitials and oxygen ions in the PrO layer form peroxide (O 2 2- ) nearby Pr vacancies. The O 2 2- limits oxygen-ion transport due to the required additional energy to break its O-O bond. We further calculated the formation and segregation energies for different Ln ions (La, Pr, Nd, Pm, Sm, Gd, Tb, Dy, and Ho) in PNO and CeO 2 (111) surfaces. In addition to Nd, Pm and La are suggested as potential dopants in PNO to enhance it stability without decomposition due to their more negative formation energies, lower diffusion energies, and positive separation energies.

01 COAL, LIGNITE, AND PEAT↗

Plasma Ignition and Combustion Stabilization Technology to Improve Flexible Operation, Reliability and Economics of an Existing Coal-Fired Boiler

GE Steam Power, Inc. (GE) proposed to improve reliability, flexibility, and economics of an existing coal-fired power plant by applying a new advanced technology developed by GE, a plasma-assisted pulverized fuel firing system. The objective of this program is to demonstrate the achievement of lower load by improved flame stabilization and therefore lower operating costs in a full-scale field installation at coal-fired electric utility. GE’s Plasma Ignition and Combustion Stabilization System is designed to operate continuously to support low load operation. With the plasma on, the flame will be attached and stable, removing the firing system as a limitation to low load operation. In addition, GE’s exclusively from ABENZ company licensed AC based technology has a 90+% system efficiency compared to all other systems at which are DC and operate with ~75% efficiency. Plant operating costs are lowered by eliminating use of expensive support fuel as well as the ability to operate at lower loads. The utilities’ ability to better match the demand curve will result in significant savings. Maintenance is lower for an AC system than a DC system as it operates at lower current. This eliminates the need for a demineralized cooling water system and provides longer electrode life which translates into both material and labor savings. It is the objective of GE to not only demonstrate the additional low load achievable with a plasma system after best achievable tuning, sensor and software approach has been exhausted, but also the increased stability of the flame at all loads with plasma assistance as well as cost savings at all low loads using plasma instead of oil. Upon successful completion of this project, GE will have sufficient field experience to rapidly deploy the Plasma Technology. The project objectives were achieved through the implementation of plasma ignitor technology at PacifiCorp Hunter Station Unit 3. A plasma ignitor system was retrofitted on ten wall-fired burners, Mill 3-4 combustion system. The Plasma Ignitors installed at Hunter proved that this GE technology is a direct and complete replacement for the original oil ignitors. The Hunter Unit 3 burner management system allows the plasma system to be used in all applications that originally required oil to be burned. This includes any time the Mill 3-4 is started or stopped for any reason including boiler starts, load changes, and low load support.

01 COAL, LIGNITE, AND PEAT↗

Deployment of Dynamic Neural Network Optimization to Minimize Heat Rate During Ramping for Coal Power Plants (Final Technical Report)

Much success was achieved throughout the course of this project. A successful implementation of Dynamic Neural Network Optimization (D-NNO) was coupled with Adaptive Predictive Controls (APC) and a novel hardware installation comprised of an advanced sensor network (ASN) measuring mass-weighted averages of flue gas constituents above the horizontal superheater of a coal-fired utility boiler. From 2019 through 2023 (including an extension due to COVID delays), the team was able to prototype, evaluate, deploy, iterate, and ultimately finalize an advanced closed-loop control D-NNO system which demonstrated the ability to: •improve unit efficiency ~2.0% relative to unoptimized operation (represented as total fuel fired per MWh generated) •improve unit NOx emission rates 10%+ beyond static optimization baselines •improve unit temperature stability as much as 58% and on average 12% •improve operating load stability as much as 35% The culmination of this project has generated an advanced methodology of deploying specially designed recurrent neural networks (long short-term memory, gated recurrent unit, encoder-decoder networks, transformers, etc.), customized trajectory planning and closed-loop optimization modules capable of adapting to live electric grid responses and demands, self-tuning and adaptive expert controls constantly adjusting prediction parameters to real-time unit behavior, and a hardware/software package able to reliably calculate net unit heat rate (NUHR) in real-time using flue gas constituents, machine learning, and known combustion relationships. Through this real-time NUHR value, immediate feedback on system adjustments relative to operating efficiency was available, allowing for rapid improvements to system performance. In addition to development and deployment of the advanced D-NNO system, the approach methodology has been readily commercialized through the project platform Griffin Open Systems, LLC, the D-NNO software platform host. Similar methodologies to those developed by this project have already been deployed at 5 other units across the United States, with another 6 implementations scheduled, and more expected. Over the course of the project, multiple academic papers were submitted and accepted for publication within esteemed academic journals, and PhD students were trained and graduated, as well as undergraduate students becoming involved and participating to project objectives.

01 COAL, LIGNITE, AND PEAT↗

Photoionization of seeded combustion products as a method of enhancing the efficiency of magnetohydrodynamic power generators

Here, in this study, we performed an experimental and computational investigation into the feasibility of utilizing photoionization to enhance the electrical conductivity of seeded oxy-fuel combustion products and improve the performance of magnetohydrodynamic (MHD) power generators. We applied a variety of optical and microwave diagnostics to study the ionization and recombination processes of potassium excited by an excimer laser in a high-velocity oxy-fuel free jet. Computational fluid dynamic (CFD) simulations were performed to model the thermophysical properties and species densities of the free jet. The CFD results were validated with position-dependent potassium concentration measurements. Electron recombination exponential lifetimes were measured through time-resolved microwave transmission. The experimental electron lifetimes were compared with lifetimes calculated from CFD-predicted species densities and literature recombination rates. It was determined that K + or O 2 are the most likely recombination partners for photoionized electrons. Time-resolved fluorescence measurements provided evidence of an ionization pathway involving a two-photon ionization of KOH . Finally, a zero-dimensional chemical kinetic model was developed to assess the fundamental viability of inducing a non-equilibrium electron population to provide a net energy return in combustion-driven MHD power generators. We determined that a high energy return is feasible for targeting electrode boundary layers with ultraviolet photoionization. We also found that photoionization could potentially lower the required temperature of the bulk gas flow.

20 FOSSIL-FUELED POWER PLANTS↗

Preheating and premixing effects on NO x emissions in a high-pressure axially staged combustor

NO x emissions remain a primary concern for modern and future gas turbines, particularly as we progress towards a net-zero carbon future. It is critical to identify novel strategies to mitigate environmental pollutants for both modern turbines operated on natural gas and future turbines projected to use carbon-free fuels (such as hydrogen). In the current study, NO x emissions of a reacting methane-air jet in a vitiated crossflow are experimentally investigated in a model axially staged combustor at 5 atm. The combustion products from the main stage combustor flow into the axial stage at temperatures ranging from 1580 to 1650 °C. The axial stage contains a reacting jet in crossflow, which provides an overall temperature rise ranging from 50 to 220 °C to generate exit temperatures similar to gas turbine engines. The focus of this paper is to explore the effects of flame liftoff and ignition timescales on the NO x contribution of this secondary jet. This is done by varying the premixed level and preheat temperature of the axial jet. The effects are explored at different momentum flux ratios (J), jet equivalence ratios (φ jet ), exit temperatures (T exit ), and main stage (headend) temperatures (T HE ). High-speed CH* chemiluminescence imaging is employed for each test case to determine the flame stabilization point. For a given temperature rise and combustor exit temperature, an increase in ignition delay was observed with a decrease in jet temperature. This provided a NO x benefit, particularly for jets that are injected at or close to an ignitable mixture fraction. Similarly, the coaxial injector caused a significant ignition delay compared to the fully premixed injector; this also led to a NO x benefit. Overall, the results show that a thermally driven delay in the axial stage provides a greater NO x reduction than a mixing delay.

03 NATURAL GAS↗