Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Formal Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Optical model analyses of heavy ion fragmentation in hydrogen targets

Quantum-mechanical optical-model methods for calculating cross sections for the fragmentation of high-energy heavy ions by hydrogen targets are presented. The cross sections are calculated with a knockout-ablation collision formalism which has no arbitrary fitting parameters. Predictions of elemental production cross sections from the fragmentation of 1.2A Ge(V(La-139) nuclei and of isotope production cross sections from the fragmentation of 400A MeV(S-32) nuclei are in good agreement with recently reported experimental measurements.

Townsend, Lawrence W.↗

Reliability and Stability of VLBI-Derived Sub-Daily EOP Models

Recent investigations have shown significant shortcomings in the model which is proposed by the IERS to account for the variations in the Earth s rotation with periods around one day and less. To overcome this, an empirical model can be estimated more or less directly from the observations of space geodetic techniques. The aim of this paper is to evaluate the quality and reliability of such a model based on VLBI observations. Therefore, the impact of the estimation method and the analysis options as well as the temporal stability are investigated. It turned out that, in order to provide a realistic accuracy measure of the model coefficients, the formal errors should be inflated by a factor of three. This coincides with the noise floor and the repeatability of the model coefficients and it captures almost all of the differences that are caused by different estimation techniques. The impact of analysis options is small but significant when changing troposphere parameterization or including harmonic station position variations.

Artz, Thomas↗

Relativistic Navigation: A Theoretical Foundation

We present a theoretical foundation for relativistic astronomical measurements in curved space-time. In particular, we discuss a new iterative approach for describing the dynamics of an isolated astronomical N-body system in metric theories of gravity. To do this, we generalize the Fock-Chandrasekhar method of the weak-field and slow-motion approximation (WFSMA) and develop a theory of relativistic reference frames (RF's) for a gravitationally bounded many-extended-body problem. In any proper RF constructed in the immediate vicinity of an arbitrary body, the N-body solutions of the gravitational field equations are formally presented as a sum of the Riemann-flat inertial space-time, the gravitational field generated by the body itself, the unperturbed solutions for each body in the system transformed to the coordinates of this proper RF, and the gravitational interaction term. We develop the basic concept of a general WFSMA theory of the celestial RF's applicable to a wide class of metric theories of gravity and an arbitrary model of matter distribution. We apply the proposed method to general relativity. Celestial bodies are described using a perfect fluid model; as such, they possess any number of internal mass and current multipole moments that explicitly characterize their internal structures. The obtained relativistic corrections to the geodetic equations of motion arise because of a coupling of the bodies' multiple moments to the surrounding gravitational field. The resulting relativistic transformations between the different RF's extend the Poincare group to the motion of deformable self-gravitating bodies. Within the present accuracy of astronomical measurements we discuss the properties of the Fermi-normal-like proper RF that is defined in the immediate vicinity of the extended compact bodies. We further generalize the proposed approximation method and include two Eddington parameters (gamma, Beta). This generalized approach was used to derive the relativistic equations of satellite motion in the vicinity of the extended bodies. Anticipating improvements in radio and laser tracking technologies over the next few decades, we apply this method to spacecraft orbit determination. We emphasize the number of feasible relativistic gravity tests that may be performed within the context of the parameterized WFSMA. Based on the planeto-centric equations of motion of a spacecraft around the planet, we suggested a new null test of the Strong Equivalence Principle (SEP). The experiment to measure the corresponding SEP violation effect could be performed with the future Mercury Orbiter mission. We discuss other relativistic effects, including the perihelion advance and the redshift and geodetic precession of the orbiter's orbital plane about Mercury, as well as the possible future implementation of the proposed formalism in software codes developed for solar-system orbit determination. All the important calculations are completely documented, and the references contain an extensive list of cited literature.

Turyshev, Slava G.↗

The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be readily detected. The MPh was able to measure dwell times down to 0.067 ± 0.001 s and planned dwell positions separated by 1 mm. The dose calculation carried out by the MPh software was found to be in agreement with values calculated by the treatment planning system within 0.75%. Using the 2D gamma index, the dose map of the MPh plane and measured EBT3 were found to have a pass rate of over 95% when compared to the original plan. Conclusions: The application of this magic phantom quality assurance system to HDR brachytherapy has demonstrated promising ability to perform the verification of treatment plans, based upon the measured dwell positions and times. The introduction of the quantitative position–time gamma index allows for direct comparison of measured parameters against the plan and could be used prior to patient treatment to ensure accurate delivery.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-15: Verifications of Absolute and Relative Dosimetry of a Novel Stereotactic Breast Device: GammaPodTM

Purpose: A dedicated stereotactic breast radiotherapy device, GammaPod, was developed to treat early stage breast cancer. The first clinical unit was installed and commissioned at University of Maryland. We report our methodology of absolute dosimetry in multiple calibration conditions and dosimetric verifications of treatment plans produced by the system. Methods: GammaPod unit is comprised of a rotating hemi-spherical source carrier containing 36 Co-60 sources and a concentric tungsten collimator providing beams of 15 and 25 mm. Absolute dose calibration formalism was developed with modifications to AAPM protocols for unique geometry and different calibration medium (acrylic, polyethylene or liquid water). Breast cup-size specific and collimator output factors were measured and verified with respect to Monte-Carlo simulations for single isocenter plans. Multiple isocenter plans were generated for various target size, location and cup-sizes in phantoms and 20 breast cancer patients images. Stereotactic mini-farmer chamber, OSL and TLD detectors as well as radio-chromic films were used for dosimetric measurements. Results: At the time of calibration (1/14/2016), absolute dose rate of the GammaPod was established to be 2.10 Gy/min in acrylic for 25 mm for sources installed in March 2011. Output factor for 15 mm collimator was measured to be 0.950. Absolute dose calibration was independently verified by IROC-Houston with a TLD/Institution ratio of 0.99. Cup size specific output measurements in liquid water for single isocenter were found to be within 3.0% of MC simulations. Point-dose measurements of multiple isocenter treatment plans were found to be within −1.0 ± 1.2 % of treatment planning system while 2-dimensional gamma analysis yielded a pass rate of 97.9 ± 2.2 % using gamma criteria of 3% and 2mm. Conclusion: The first GammaPod treatment unit for breast stereotactic radiotherapy was successfully installed, calibrated and commissioned for patient treatments. An absolute dosimetry and dosimetric verification protocols were successfully created.

60 APPLIED LIFE SCIENCES↗

Structural and transport properties of double perovskite Dy{sub 2}NiMnO{sub 6}

Highlights: • Sol–gel citrate method is used to prepare the double perovskite Dy{sub 2}NiMnO{sub 6}. • Structure and dielectric relaxation of the sample are studied for nano and bulk phases. • The relaxation mechanism of the sample is modeled by Cole–Cole equation. • With increasing sintering temperature conductivity increases. • Electronic structures and magnetic properties have been studied by DFT calculations. - Abstract: The double perovskite oxide Dy{sub 2}NiMnO{sub 6} (DNMO) is synthesized in nano and bulk phase by the sol–gel citrate method. The Rietveld refinement of X-ray diffraction pattern of the sample at room temperature shows the monoclinic P2{sub 1}/n phase. Dielectric relaxation of the sample is investigated in the impedance and electric modulus formalisms in the frequency range from 50 Hz to 1 MHz and in the temperature range from 253 to 415 K. The Cole–Cole model is used to explain the relaxation mechanism in DNMO. The frequency-dependent maxima in the imaginary part of impedance are found to obey an Arrhenius law with activation energy of 0.346 and 0.344 eV for nano and bulk DNMO, respectively. A significant increase in conductivity of bulk DNMO has been observed than that of the nanoceramic. Electronic structures and magnetic properties of DNMO have been studied by performing first principles calculation based on density functional theory.

36 MATERIALS SCIENCE↗

Systems and methods for determining optimal parameters for dynamic quantum clustering analyses

In the present work, quantum clustering is extended to provide a dynamical approach for data clustering using a time-dependent Schrodinger equation. To expedite computations, we can approximate the time-dependent Hamiltonian formalism by a truncated calculation within a set of Gaussian wave-functions (coherent states) centered around the original points. This allows for analytic evaluation of the time evolution of all such states, opening up the possibility of exploration of relationships among data points through observation of varying dynamical-distances among points and convergence of points into clusters. This formalism may be further supplemented by preprocessing, such as dimensional reduction through singular value decomposition and/or feature filtering. Additionally, the parameters of the analysis can be modified in order to improve the efficiency of the dynamic quantum clustering processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature-Dependent Configurational Entropy Calculations for Refractory High-Entropy Alloys

The cluster expansion formalism for alloys is used to construct surrogate models for three refractory high-entropy alloys (NbTiVZr, HfNbTaTiZr, and AlHfNbTaTiZr). These cluster expansion models are then used along with Monte Carlo methods and thermodynamic integration to calculate the configurational entropy of these refractory high-entropy alloys as a function of temperature. Many solid solution alloy design guidelines are based on the ideal entropy of mixing, which increases monotonically with N , the number of elements in the alloy. However, our results show that at low temperatures, the configurational entropy of these materials is largely independent of N , and the assumption described above only holds in the high-temperature limit. This suggests that alloy design guidelines based on the ideal entropy of mixing require further examination.

36 MATERIALS SCIENCE↗

Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

The declared linear density of 238 U and 235 U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235 U (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This article compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Here, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combined Effects of Hemicolligation and Ion Pairing on Reduction Potentials of Biphenyl Radical Cations

Here, formal reduction potentials of highly oxidizing and short-lived radical cations of substituted biphenyls generated by pulse radiolysis in 1,2-dichloroethane (DCE) were measured using a redox equilibrium ladder method. The effect of halide ion–radical interactions on reduction potentials of biphenyls was examined by utilizing the ability of DCE to release Cl – in the vicinity of the radical cation. The Hammett correlation of measured potentials across a range of over 700 mV shows saturation at high Hammett sigma values. This effect has been explained by both ion-pairing and hemicolligation interactions between biphenyl radical cations and Cl – and appears to modulate reduction potentials by as much as 400 mV. This finding offers a convenient way to manipulate the energetics of electron transfer involving organic redox species.

14 SOLAR ENERGY↗

Coupled Cluster Green's function formulations based on the effective Hamiltonians

In this work, we demonstrate that the effective Hamiltonians obtained with the downfolding procedure based on double unitary coupled cluster (DUCC) ansatz can be used in the context of Green’s function coupled cluster (GFCC) formalism to calculate spectral functions of molecular systems. This combined approach (DUCC-GFCC) provides a significant reduction of numerical effort and good agreement with the corresponding all-orbital GFCC methods in energy windows that are consistent with the choice of active space. These features are demonstrated on the example of two benchmark systems: H 2 O and N 2 , where DUCC-GFCC calculations were performed for active spaces of various sizes.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-447: Electronic Brachytherapy (EBT) Treatment of Cervical Cancer - First Clinical Experience

Purpose: To study the first trial patient in which an electronic brachytherapy (EBT) x-ray source is utilized for treatment of cervical cancer. Methods: During patient treatment, a miniaturized x-ray source was used in combination with a customized titanium tandem and ovoid applicator set. The semi-specialized source was modeled with formalisms outlined by AAMP Task Group 43. Multiple models were used to compensate for variable attenuation conditions as a function of source positions. Varian Brachyvision treatment planning software was utilized on CT data sets for dose calculations prior to treatment delivery. The dose was prescribed to “point A” as defined by American Brachytherapy society. Additional treatments plans were created from those clinically utilized in patient care and were recalculated for an existing Ir-192 source model. Dose volume histograms (DVH) and point dose calculations were compared between the modalities for the clinical condition present in patients treated with EBT. Results: Clinical treatment times, though longer than those typically experienced by Ir-192 users, were manageable. Instantaneous dose rates at personal positions within the treatment vault were lower than those measured during intra operative radiation therapy and breast EBT treatments. Due to lower average photon energy in EBT, dose gradients within the treatment plans were as expected steeper than those observed in Ir-192 based brachytherapy. DVH comparisons between Ir-192 and EBT treatments showed an expected decrease in the integral dose to normal tissues of interest for EBT. In comparing plans created for EBT delivery with those calculated for Ir-192, average dose values for EBT were more than 4%, 11%, and 9% lower at predefined bladder, rectum and “point B” positions, respectively. Conclusion: For the first time, we have demonstrated that the utilizing electronic brachytherapy system for tandem and ovoid based treatment of cancer of the cervix is feasible, and potentially beneficial, in clinical environment.

60 APPLIED LIFE SCIENCES↗

A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR {sup 192}Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.

07 ISOTOPE AND RADIATION SOURCES↗

P–V–T Equation of State of Iridium Up to 80 GPa and 3100 K

In the present study, the high-pressure high-temperature equation of the state of iridium has been determined through a combination of in situ synchrotron X-ray diffraction experiments using laser-heating diamond-anvil cells (up to 48 GPa and 3100 K) and density-functional theory calculations (up to 80 GPa and 3000 K). The melting temperature of iridium at 40 GPa was also determined experimentally as being 4260 (200) K. The results obtained with the two different methods are fully consistent and agree with previous thermal expansion studies performed at ambient pressure. The resulting thermal equation of state can be described using a third-order Birch–Murnaghan formalism with a Berman thermal-expansion model. The present equation of the state of iridium can be used as a reliable primary pressure standard for static experiments up to 80 GPa and 3100 K. A comparison with gold, copper, platinum, niobium, rhenium, tantalum, and osmium is also presented. On top of that, the radial-distribution function of liquid iridium has been determined from experiments and calculations.

36 MATERIALS SCIENCE↗

Formal Solutions for Polarized Radiative Transfer. I. The DELO Family

The discussion regarding the numerical integration of the polarized radiative transfer equation is still open and the comparison between the different numerical schemes proposed by different authors in the past is not fully clear. Aiming at facilitating the comprehension of the advantages and drawbacks of the different formal solvers, this work presents a reference paradigm for their characterization based on the concepts of order of accuracy , stability , and computational cost . Special attention is paid to understand the numerical methods belonging to the Diagonal Element Lambda Operator family, in an attempt to highlight their specificities.

79 ASTRONOMY AND ASTROPHYSICS↗

Aircraft electric field measurements: Calibration and ambient field retrieval

An aircraft locally distorts the ambient thundercloud electric field. In order to determine the field in the absence of the aircraft, an aircraft calibration is required. In this work a matrix inversion method is introduced for calibrating an aircraft equipped with four or more electric field sensors and a high-voltage corona point that is capable of charging the aircraft. An analytic, closed form solution for the estimate of a (3 x 3) aircraft calibration matrix is derived, and an absolute calibration experiment is used to improve the relative magnitudes of the elements of this matrix. To demonstrate the calibration procedure, we analyze actual calibration date derived from a Lear jet 28/29 that was equipped with five shutter-type field mill sensors (each with sensitivities of better than 1 V/m) located on the top, bottom, port, starboard, and aft positions. As a test of the calibration method, we analyze computer-simulated calibration data (derived from known aircraft and ambient fields) and explicitly determine the errors involved in deriving the variety of calibration matrices. We extend our formalism to arrive at an analytic solution for the ambient field, and again carry all errors explicitly.

Koshak, William J.↗

Recent Progress on the Stochastic Objective Decision Aide (SODA) Application

Idaho State University, in collaboration with Idaho National Laboratory, is engaged in development of a simple to use software application that utilizes stochastic techniques for the calculation of radiation doses associated with hypothetical radioactive material releases. This work is being performed through a grant from the U.S. Department of Energy (DOE) Nuclear Safety Research and Development (NSR and D) Program. Initial progress on the application was reported previously. Recent additions to the application are reported here. The Stochastic Objective Decision Aide (SODA) provides an easy to use software application to help decision makers support their judgment about the need or lack of need for safety structures, systems, and components. SODA is not intended to replace traditional design basis accident dose calculation methodology, nor is it intended to replace existing software used to perform formal dose consequence calculations. Rather, SODA is intended to supplement information obtained from existing codes to give a decision maker more information about an accident scenario. SODA also provides a simple method to perform parametric or sensitivity studies on individual input parameters. Non-reactor nuclear facilities operated under the approval authority of the US DOE use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge dose evaluation guidelines. Unmitigated events that sufficiently challenge dose evaluation guidelines merit the selection of safety structures, systems, or components (SSCs) to prevent or mitigate the hazard. Dose consequence calculations traditionally involve use of the 'five-factor' formula: ST = MAR.DR.ARF.RF.LPF where ST is the source term (Bq), MAR is the total available material-at-risk (Bq), DR is the damage ratio (no units), ARF is the airborne release fraction (no units), RF is the respirable fraction (no units), and LPF is the leak path factor (no units). Potential radiation doses are then calculated using: CED = χ/Q.BR.ST.DCF (2) where CED is the committed effective dose (Sv), χ/Q is the plume dispersion (s/m{sup 3}), BR is the breathing rate (m{sup 3}/s), ST is the source term (Bq), and DCF is the dose conversion factor (Sv/Bq). Conservative single value input parameters are typically used to represent ARF, RF, LPF and BR. The traditional methodology, while conservative, can lead to skewed conclusions in the balance between cost and risk reduction resulting in over engineered systems with greater design, construction and operating costs. Rather than using a bounding single point value for each parameter in the dose consequence calculation, SODA uses distributions for some or all of the parameters. Each input parameter distribution is stochastically sampled and the resulting dose consequence calculation is repeated many times to develop a dose consequence distribution. The resulting distribution provides more information for the decision maker to rely upon when determining the need for safety SSCs. The SODA application was developed using MATLAB and it incorporates the use of Monte Carlo techniques as well as a graphical user interface (GUI). The application includes user selection of the governing distribution for parameters such as the MAR, DR, ARF, RF, LPF,χ/Q, BR, and DCF. While MATLAB was used for the development work, the application is distributed as a self-contained executable program. Features of the application include pull down menus with available distributions for the various parameters. The user has the option to plot the input parameter distribution that results from the random sampling process. The resulting dose consequence distribution is automatically analyzed to determine its similarity to well know distributions. This was done using the Bayesian Information Criterion method. If the resulting distribution is sufficiently similar to a well-known distribution, the application provides information about the distributions such as the mean value and other parameters. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-D-201-07: A Survey of Radiation Oncology Residents’ Training and Preparedness to Lead Patient Safety Programs in Clinics

Purpose: Safety and quality has garnered increased attention in radiation oncology, and physicians and physicists are ideal leaders of clinical patient safety programs. However, it is not clear whether residency programs incorporate formal patient safety training and adequately equip residents to assume this leadership role. A national survey was conducted to evaluate medical and physics residents’ exposure to safety topics and their confidence with the skills required to lead clinical safety programs. Methods: Radiation oncology residents were identified in collaboration with ARRO and AAPM. The survey was released in February 2016 via email using REDCap. This included questions about exposure to safety topics, confidence leading safety programs, and interest in training opportunities (i.e. workshops). Residents rated their exposure, skills, and confidence on 4 or 5-point scales. Medical and physics residents responses were compared using chi-square tests. Results: Responses were collected from 56 of 248 (22%) physics and 139 of 690 (20%) medical residents. More than two thirds of all residents had no or only informal exposure to incident learning systems (ILS), root cause analysis (RCA), failure mode and effects analysis (FMEA), and the concept of human factors engineering (HFE). Likewise, 63% of residents had not heard of RO-ILS. Response distributions were similar, however more physics residents had formal exposure to FMEA (p<0.0001) and felt they were adequately trained to lead FMEAs in clinic (p<0.001) than medical residents. Only 36% of residents felt their patient safety training was adequate, and 58% felt more training would benefit their education. Conclusion: These results demonstrate that, despite increasing desire for patient safety training, medical and physics residents’ exposure to relevant concepts is low. Physics residents had more exposure to FMEA than medical residents, and were more confident in leading FMEA. This suggests that increasing resident exposure to specific topics may increase their confidence.

60 APPLIED LIFE SCIENCES↗