Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Female”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Sustained virological response with intravenous silibinin: individualized IFN-free therapy via real-time modelling of HCV kinetics

Providing here our aims and project background, we note that intravenous silibinin (SIL) is a potent antiviral agent against hepatitis C virus (HCV) genotype-1. In this proof of concept case-study we tested: (i) whether interferon-alfa (IFN)-free treatment with SIL plus ribavirin (RBV) can achieve sustained virological response (SVR); (ii) whether SIL is safe and feasible for prolonged duration of treatment and (iii) whether mathematical modelling of early on-treatment HCV kinetics can guide duration of therapy to achieve SVR. With our method, a 44 year-old female HCV-(genotype-1)-infected patient who developed severe psychiatric adverse events to a previous course of pegIFN+RBV, initiated combination treatment with 1200 mg/day of SIL, 1200 mg/day of RBV and 6000 u/day vitamin D. Blood samples were collected frequently till week 4, thereafter every 1-12 weeks until the end of therapy. The standard biphasic mathematical model with time-varying SIL effectiveness was used to predict the duration of therapy to achieve SVR. Our results show that, based on modelling the observed viral kinetics during the first 3 weeks of treatment, SVR was predicted to be achieved within 34 weeks of therapy. Provided with this information, the patient agreed to complete 34 weeks of treatment. IFN-free treatment with SIL+RBV was feasible, safe and achieved SVR (week-33). In conclusion, we report, for the first time, the use of real-time mathematical modelling of HCV kinetics to individualize duration of IFN-free therapy and to empower a patient to participate in shared decision making regarding length of treatment. SIL-based individualized therapy provides a treatment option for patients who do not respond to or cannot receive other HCV agents and should be further validated.

59 BASIC BIOLOGICAL SCIENCES↗

“Figure‐of‐Eight” Suture‐Button Technique for Fixation of Displaced Anterior Cruciate Ligament Avulsion Fracture

Objective To assess the clinical results of the “figure‐of‐eight” suture‐button technique in the arthroscopic treatment of anterior cruciate ligament (ACL) tibial avulsion fractures. Methods This was a retrospective study reviewing data from September 2013 to June 2019. A total of 27 patients (13 males and 14 females) who underwent arthroscopic “figure‐of‐eight” suture‐button fixation for displaced ACL avulsion fractures were analyzed. The mean age of the patients in the sample was 15.8 years (10–29 years), with a mean follow‐up of 24 months (6–48 months). According to Meyers–McKeever classification, 11 patients were classified as type III and 16 as type IV. All patients were evaluated following the guidelines of the radiological union, the Lysholm knee scoring scale, and the International Knee Documentation Committee (IKDC). Results Fractures were united within 3 months after surgery in all 27 cases. During the last follow‐up, all the anterior drawer and Lachman tests were negative, except in 1 patient whose anterior drawer test was 1° positive. The range of motion was improved from 72.22° ± 27.92° before surgery to 137.78° ± 7.38° at the last follow‐up ( P < 0.05); the Lysholm score was improved from 45.81 ± 10.94 before surgery to 93.04 ± 5.66 at the last follow‐up ( P < 0.05); and the IKDC score was increased from 43.89 ± 11.16 before surgery to 90.26 ± 5.86 at the last follow‐up ( P < 0.05). In 1 patient, an inflammatory reaction was observed at the medial incision of the tibial tubercle; the symptoms disappeared with administration of antibiotics for 1 week. All patients returned to their preinjury physical activities at the last follow‐up. Conclusion The “figure‐of‐eight” suture‐button technique achieves a satisfactory clinical outcome and provides an effective method for the treatment of displaced ACL avulsion fractures.

Kuang, Shi‐da↗

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model

Abstract Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub‐data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm 3 , the mid‐anterior distance was 1.72 ± 0.19 cm, the mid‐posterior distance was 2.00 ± 0.19 cm, the ratio of mid‐anterior to mid‐posterior was 0.87, the mid‐medial distance was 1.26 ± 0.17 cm, the mid‐lateral distance was 1.19 ± 0.16 cm, and the ratio of mid‐medial to mid‐lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 ± 0.32 cm, the transverse diameter was 2.46 ± 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid‐anterior distance was strongly negatively correlated with age, the mid‐anterior distance and the amount of bone resection, the mid‐medial distance and the amount of bone resection, the mid‐lateral distance and the amount of bone resection, the mid‐lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Wu, Shi‐xun↗

In situ embryo rescue for generation of wide intra‐ and interspecific hybrids of Panicum virgatum L.

Summary Wide crosses have been used for decades as a method for transferring novel genetic material and traits in plant breeding. Historically, many products of wide crosses require tedious and inefficient surgical embryo rescue prior to embryo abortion to recover single plantlets. We have utilized transgenic switchgrass ( Panicum virgatum L. cv Alamo) as a pollen donor in conjunction with antibiotic or herbicide selection for recovery of intra‐and interspecific F 1 crosses by using developing ovules from the female parent and selecting for embryogenic cultures derived from the in situ immature embryo. Using this approach, several intravarietial crosses were generated between transgenic Alamo and the switchgrass varieties Kanlow, Blackwell and Cave ‐ in ‐ Rock as well as an interspecific cross with Atlantic coastal panicgrass. This procedure selected F 1 embryogenic callus produced from the developing embryo contained within isolated immature ovules. Several clonal plants were successfully regenerated from each cross. Southern blot, PCR , phenotypic analyses and genomic analysis confirmed F 1 hybrids. Using genotyping‐by‐sequencing shows the hybridization of the recovered plants by determining the ratio of transgressive markers to total compared markers between parents and their potential offspring. The ratio of transgressive markers to total compared markers was significantly lower between parents and their predicted offspring than between parents and offspring unrelated to them. This approach provides the possibility to move useful transgenes into varieties that are recalcitrant to direct transformation which can be optionally segregated thus useful to create new hybrids, as well as recovery of wide crosses that are either difficult or impossible using traditional techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Contrasting anther glucose–6–phosphate dehydrogenase activities between two bean varieties suggest an important role in reproductive heat tolerance

Common beans (Phaseolus vulgaris) are highly sensitive to elevated temperatures, and rising global temperatures threaten bean production. Plants at the reproductive stage are especially susceptible to heat stress due to damage to male (anthers) and female (ovary) reproductive tissues, with anthers being more sensitive to heat. Heat damage promotes early tapetal cell degradation, and in beans this was shown to cause male infertility. In this study, we focus on understanding how changes in leaf carbon export in response to elevated temperature stress contribute to heat-induced infertility. We hypothesize that anther glucose-6-phosphate dehydrogenase (G6PDH) activity plays an important role at elevated temperature and promotes thermotolerance. To test this hypothesis, we compared heat-tolerant and susceptible common bean genotypes using a combination of phenotypic, biochemical, and physiological approaches. Our results identified changes in leaf sucrose export, anther sugar accumulation and G6PDH activity and anther H 2 O 2 levels and antioxidant-related enzymes between genotypes at elevated temperature. Further, anther respiration rate was found to be lower at high temperature in both bean varieties. Overall, our results support the hypothesis that enhanced male reproductive heat tolerance involves changes in the anther oxidative pentose phosphate pathway, which supplies reductants to critical H 2 O 2 scavenging enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Similar local, but different systemic, metabolomics responses of closely related pine subspecies to folivory by caterpillars of the processionary moth

Plants respond locally and systemically to herbivore attack. Most of the research conducted on plant-herbivore relationships at elemental and molecular levels have focused on nutrients or/and certain molecular compounds or specific families of defensive metabolites showing that herbivores tend to select plant individuals or species with higher nutrient concentrations and to avoid those with higher levels of phenolics and terpenes. Unfortunately, the defensive role of phenolics in conifers is still unclear. We performed stoichiometric and metabolomics, local and systemic, analyses in two subspecies of Pinus sylvestris under the herbivorous attack by the caterpillars of the pine processionary moth, an important pest in the Mediterranean Basin. Herbivorous attack was not associated with any of the elements analyzed. Both pine subspecies responded locally to folivory mainly by increasing the concentrations of various terpenes and phenolics. Systemic responses differed between subspecies and most of the metabolites presented intermediate concentrations between those of the affected parts and unattacked trees. Contrary as usually thought, foliar nutrient concentrations did not show to be a main factor of an alleged plant selection by adult female processionary moths for oviposition. Local increases in phenolics were more associated with antioxidant function for protection against oxidative damage produced by folivory. On the other hand, terpenes were directly related to defense against herbivores. Herbivory attack produced a general systemic shift in pines, including both primary and secondary metabolisms, that was, however, less intense and chemically different from the local responses. Subspecies responded similarly locally but differently to folivory at systemic level.

Environmental Molecular Sciences Laboratory↗

Combining multiple models to generate consensus: Application to radiation-induced pneumonitis prediction

The fusion of predictions from disparate models has been used in several fields to obtain a more realistic and robust estimate of the ''ground truth'' by allowing the models to reinforce each other when consensus exists, or, conversely, negate each other when there is no consensus. Fusion has been shown to be most effective when the models have some complementary strengths arising from different approaches. In this work, we fuse the results from four common but methodologically different nonlinear multivariate models (Decision Trees, Neural Networks, Support Vector Machines, Self-Organizing Maps) that were trained to predict radiation-induced pneumonitis risk on a database of 219 lung cancer patients treated with radiotherapy (34 with Grade 2+ postradiotherapy pneumonitis). Each model independently incorporated a small number of features from the available set of dose and nondose patient variables to predict pneumonitis; no two models had all features in common. Fusion was achieved by simple averaging of the predictions for each patient from all four models. Since a model's prediction for a patient can be dependent on the patient training set used to build the model, the average of several different predictions from each model was used in the fusion (predictions were made by repeatedly testing each patient with a model built from different cross-validation training sets that excluded the patient being tested). The area under the receiver operating characteristics curve for the fused cross-validated results was 0.79, with lower variance than the individual component models. From the fusion, five features were extracted as the consensus among all four models in predicting radiation pneumonitis. Arranged in order of importance, the features are (1) chemotherapy; (2) equivalent uniform dose (EUD) for exponent a=1.2 to 3; (3) EUD for a=0.5 to 1.2, lung volume receiving >20-30 Gy; (4) female sex; and (5) squamous cell histology. To facilitate ease of interpretation and prospective use, the fused outcome results for the patients were fitted to a logistic probability function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of radiation dose delivered by cone beam CT and tomosynthesis employed for setup of external breast irradiation

A systematic set of measurements is reported for evaluation of doses to critical organs resulting from cone-beam CT (CB-CT) and cone-beam tomosynthesis (CB-TS) as applied to breast setup for external beam irradiation. The specific focus of this study was on evaluation of doses from these modalities in a setting of volumetric breast imaging for target localization in radiotherapy treatments with the goal of minimizing radiation to healthy organs. Ion chamber measurements were performed in an anthropomorphic female thorax phantom at the center of each breast and lung and on the phantom surface at one anterior and two lateral locations (seven points total). The measurements were performed for three different isocenters located at the center of the phantom and at offset locations of the right and left breast. The dependence of the dose on angle selection for the CB-TS arc was also studied. For the most typical situation of centrally located CB-CT isocenter the measured doses ranged between 3 and 7 cGy, in good agreement with previous reports. Dose measurements were performed for a range of start/stop angles commonly used for CB-TS and the impact of direct and scatter dose on organs at risk was analyzed. All measured CB-TS doses were considerably lower than CB-CT doses, with greater decrease in dose for the organs outside of the beam (up to 98% decrease in dose). Remarkably, offsetting the isocenter towards the ipsilateral breast resulted on average to additional 46% dose reduction to organs at risk. The lowest doses to the contralateral breast and lung were less than 0.1 cGy when they were measured for the offset isocenter. The biggest reduction in dose was obtained by using CB-TS beams that completely avoid the critical organ. For points inside the CB-TS beam, the dose was reduced in a linear relation with distance from the center of the imaging arc. The data indicate that it is possible to reduce substantially radiation doses to the contralateral organs by proper selection of CB-TS angles and imaging field sizes. Our results provide the first systematic study on CB-TS doses from setup imaging for external breast irradiation and can be a useful resource for estimating anticipated radiation doses as a function of the conditions chosen for imaging breast setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skeletal dosimetry in cone beam computed tomography

Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm{sup 3}, with 17x17x17 {mu}m{sup 3} microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens ({approx}8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only {approx}50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

61 RADIATION PROTECTION AND DOSIMETRY↗

Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional radiogenic lethal cancer incidents. According to the decision model calculations, the use of CT is more favorable over the use of radiography alone or radiography with CT by a factor of 13, for low risk 20 yr old patients, to a factor of 23, for high risk patients younger than 80 yr old. The radiography/CT imaging strategy slightly outperforms plain radiography for high and moderate risk patients. Regardless of the patient age, sex, and fracture risk, the higher diagnostic accuracy obtained by the CT examination counterbalances the increase in dose compared to plain radiography or radiography followed by CT only for positive radiographs and renders CT utilization justified and the radiographic screening redundant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reducing radiation dose to selected organs by selecting the tube start angle in MDCT helical scans: A Monte Carlo based study

Purpose: Previous work has demonstrated that there are significant dose variations with a sinusoidal pattern on the peripheral of a CTDI 32 cm phantom or on the surface of an anthropomorphic phantom when helical CT scanning is performed, resulting in the creation of ''hot'' spots or ''cold'' spots. The purpose of this work was to perform preliminary investigations into the feasibility of exploiting these variations to reduce dose to selected radiosensitive organs solely by varying the tube start angle in CT scans. Methods: Radiation dose to several radiosensitive organs (including breasts, thyroid, uterus, gonads, and eye lenses) resulting from MDCT scans were estimated using Monte Carlo simulation methods on voxelized patient models, including GSF's Baby, Child, and Irene. Dose to fetus was also estimated using four pregnant female models based on CT images of the pregnant patients. Whole-body scans were simulated using 120 kVp, 300 mAs, both 28.8 and 40 mm nominal collimations, and pitch values of 1.5, 1.0, and 0.75 under a wide range of start angles (0 deg. - 340 deg. in 20 deg. increments). The relationship between tube start angle and organ dose was examined for each organ, and the potential dose reduction was calculated. Results: Some organs exhibit a strong dose variation, depending on the tube start angle. For small peripheral organs (e.g., the eye lenses of the Baby phantom at pitch 1.5 with 40 mm collimation), the minimum dose can be 41% lower than the maximum dose, depending on the tube start angle. In general, larger dose reductions occur for smaller peripheral organs in smaller patients when wider collimation is used. Pitch 1.5 and pitch 0.75 have different mechanisms of dose reduction. For pitch 1.5 scans, the dose is usually lowest when the tube start angle is such that the x-ray tube is posterior to the patient when it passes the longitudinal location of the organ. For pitch 0.75 scans, the dose is lowest when the tube start angle is such that the x-ray tube is anterior to the patient when it passes the longitudinal location of the organ. Conclusions: Helical MDCT scanning at pitch 1.5 and pitch 0.75 results in ''cold spots'' and ''hot spots'' that are created both at surface and in-depth locations within patients. For organs that have a relatively small longitudinal extent, dose can vary considerably with different start angles. While current MDCT systems do not provide the user with the ability to control the tube start angle, these results indicate that in these specific situations (pitch 1.5 or pitch 0.75, small organs and especially small patients), there could be significant dose savings to organs if that functionality would be provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantification of breast density with dual energy mammography: An experimental feasibility study

Purpose: Breast density, the percentage of glandular breast tissue, has been shown to be a strong indicator of breast cancer risk. A quantitative method to measure breast density with dual energy mammography was investigated using physical phantoms. Methods: The dual energy mammography system used a tungsten anode x-ray tube with a 50 {mu}m rhodium beam filter for low energy images and a 300 {mu}m copper beam filter for high energy images. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Four different phantom studies were used to evaluate the technique. The first study consisted of phantoms with thicknesses of 2.5-8.5 cm in 0.5 cm steps with variable densities centered at a mean of 28%. The second study consisted of phantoms at a fixed thickness of 4.0 cm, which ranged in densities from 0% to 100% in increments of 12.5%. The third study consisted of 4.0 cm thick phantoms at densities of 25%, 50% and 75% each imaged at three areal sizes, approximately 62.5, 125, and 250 cm{sup 2}, in order to assess the effect of breast size on density measurement. The fourth study consisted of step phantoms designed to more closely mimic the shape of a female breast with maximal thicknesses from 3.0 to 7.0 cm at a fixed density of 50%. All images were corrected for x-ray scatter. Results: The RMS errors in breast density measurements were 0.44% for the variable thickness phantoms, 0.64% for the variable density phantoms, 2.87% for the phantoms of different areal sizes, and 4.63% for step phantoms designed to closely resemble the shape of a breast. Conclusions: The results of the phantom studies indicate that dual energy mammography can be used to measure breast density with an RMS error of approximately 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDI{sub vol} to account for differences between scanners

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup

Purpose: To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. Methods: The dose measurements were performed in a female torso phantom for varying scan angles of CBTS. Setup accuracy was measured using three registration methods: Clip centroid localization accuracy and the accuracy of two semiautomatic registration algorithms. The dose to the organs outside of the ipsilateral breast and registration accuracy information were compared to determine the optimal scan angle for CBTS for breast patient setup verification. Isocenter positions at the center of the patient and at the breast-chest wall interface were considered. Results: Image registration accuracy was within 1 mm for the CBTS scan angles {theta} above 20 deg. for some scenarios and as large as 80 deg. for the worst case, depending on the imaged breast and registration algorithm. Registration accuracy was highest based on clip centroid localization. For left and right breast imaging with the isocenter at the chest wall, the dose to the contralateral side of the patient was very low (<0.5 cGy) for all scan angles considered. For central isocenter location, the optimal scan angles were 30 deg. - 50 deg. for the left breast imaging and 40 deg. - 50 deg. for the right breast imaging, with the difference due to the geometric asymmetry of the current clinical imaging system. Conclusions: The optimal scan angles for CBTS imaging were found to be between 10 deg. and 50 deg., depending on the isocenter location and ipsilateral breast. Use of the isocenter at the breast-chest wall locations always resulted in greater accuracy of image registration (<1 mm) at smaller angles (10 deg. - 20 deg.) and at lower doses (<0.1 cGy) to the contralateral organs. For chest wall isocenters, doses delivered to organs outside of the target breast were much smaller than the scattered and leakage doses of the treatment beams. The complete volumetric information of all clips in the region of interest, combined with the small dose to the contralateral organs and the small scan angle, could result in an advantage for small angle CBTS with off center isocenters over simple orthogonal pairs.

60 APPLIED LIFE SCIENCES↗

Comparison of radiation exposure and associated radiation-induced cancer risks from mammography and molecular imaging of the breast

Purpose: Recent studies have raised concerns about exposure to low-dose ionizing radiation from medical imaging procedures. Little has been published regarding the relative exposure and risks associated with breast imaging techniques such as breast specific gamma imaging (BSGI), molecular breast imaging (MBI), or positron emission mammography (PEM). The purpose of this article was to estimate and compare the risks of radiation-induced cancer from mammography and techniques such as PEM, BSGI, and MBI in a screening environment. Methods: The authors used a common scheme for all estimates of cancer incidence and mortality based on the excess absolute risk model from the BEIR VII report. The lifetime attributable risk model was used to estimate the lifetime risk of radiation-induced breast cancer incidence and mortality. All estimates of cancer incidence and mortality were based on a population of 100 000 females followed from birth to age 80 and adjusted for the fraction that survives to various ages between 0 and 80. Assuming annual screening from ages 40 to 80 and from ages 50 to 80, the cumulative cancer incidence and mortality attributed to digital mammography, screen-film mammography, MBI, BSGI, and PEM was calculated. The corresponding cancer incidence and mortality from natural background radiation was calculated as a useful reference. Assuming a 15%-32% reduction in mortality from screening, the benefit/risk ratio for the different imaging modalities was evaluated. Results: Using conventional doses of 925 MBq Tc-99m sestamibi for MBI and BSGI and 370 MBq F-18 FDG for PEM, the cumulative cancer incidence and mortality were found to be 15-30 times higher than digital mammography. The benefit/risk ratio for annual digital mammography was >50:1 for both the 40-80 and 50-80 screening groups, but dropped to 3:1 for the 40-49 age group. If the primary use of MBI, BSGI, and PEM is in women with dense breast tissue, then the administered doses need to be in the range 75-150 MBq for Tc-99m sestamibi and 35 MBq-70 MBq for F-18 FDG in order to obtain benefit/risk ratios comparable to those of mammography in these age groups. These dose ranges should be achievable with enhancements to current technology while maintaining a reasonable examination time. Conclusions: The results of the dose estimates in this study clearly indicate that if molecular imaging techniques are to be of value in screening for breast cancer, then the administered doses need to be substantially reduced to better match the effective doses of mammography.

61 RADIATION PROTECTION AND DOSIMETRY↗

Patient-specific radiation dose and cancer risk estimation in CT: Part I. Development and validation of a Monte Carlo program

Purpose: Radiation-dose awareness and optimization in CT can greatly benefit from a dose-reporting system that provides dose and risk estimates specific to each patient and each CT examination. As the first step toward patient-specific dose and risk estimation, this article aimed to develop a method for accurately assessing radiation dose from CT examinations. Methods: A Monte Carlo program was developed to model a CT system (LightSpeed VCT, GE Healthcare). The geometry of the system, the energy spectra of the x-ray source, the three-dimensional geometry of the bowtie filters, and the trajectories of source motions during axial and helical scans were explicitly modeled. To validate the accuracy of the program, a cylindrical phantom was built to enable dose measurements at seven different radial distances from its central axis. Simulated radial dose distributions in the cylindrical phantom were validated against ion chamber measurements for single axial scans at all combinations of tube potential and bowtie filter settings. The accuracy of the program was further validated using two anthropomorphic phantoms (a pediatric one-year-old phantom and an adult female phantom). Computer models of the two phantoms were created based on their CT data and were voxelized for input into the Monte Carlo program. Simulated dose at various organ locations was compared against measurements made with thermoluminescent dosimetry chips for both single axial and helical scans. Results: For the cylindrical phantom, simulations differed from measurements by -4.8% to 2.2%. For the two anthropomorphic phantoms, the discrepancies between simulations and measurements ranged between (-8.1%, 8.1%) and (-17.2%, 13.0%) for the single axial scans and the helical scans, respectively. Conclusions: The authors developed an accurate Monte Carlo program for assessing radiation dose from CT examinations. When combined with computer models of actual patients, the program can provide accurate dose estimates for specific patients.

60 APPLIED LIFE SCIENCES↗