Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Carbon constraint conference: dealing with the climate change conundrum

A report on the carbon constraint conference is given. Papers discussed the US national cap-and-trade program that is on the horizon, managing greenhouse gases, the value of corporate sustainability reporting, balancing the generation portfolio and the use of offsets. 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Arch Coal upgrades a classic West Virginia prep plant

Holden No. 22 coal preparation plant evolves from 1970s 'by zero' technology to modern, efficient fine coal recovery that includes a de-slime dense-media cyclone, compound spiral circuit. 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Western Kentucky revival

Armstrong Coal resurrects idled mines and equipment in a once vital coal mining region. 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Fossil energy, clean coal technology, and FutureGen

Future fossil use will rely heavily on carbon sequestration. Clean coal technologies are being incorporated in the USA, including air pollution control, and will need to incorporate carbon capture and sequestration. The paper ends with an outline of the restructured FutureGen project. 7 figs.

20 FOSSIL-FUELED POWER PLANTS↗

Wisconsin Public Service Corp's Weston 4 earns Power's highest honor

Wisconsin Public Service Corp. placed its world-class Weston 4 into commercial service on June 30 and is now enjoying the benefits of coal-fired supercritical technology's inherently higher efficiency, operating flexibility and lower CO{sub 2} emissions. For its unequalled environmental protection credentials, well-integrated project team, and employing the most advanced coal-fired steam generation technology in the US today, Weston 4 is awarded Power magazine's 2008 Plant of the Year Award. 10 figs., 4 tabs.

20 FOSSIL-FUELED POWER PLANTS↗

Lamar repowering project's creative modeling of old and new wins Marmaduke award

Lamar Light and Power is a municipal utility that has been generating the south eastern Colorado city's electricity since 1920. Rising natural gas and oil costs pushed LL & P to retire its steam plant five years ago and begin hunting for more economic power sources. The answer: repower the existing plant with a state-of-the-art coal-fired circulating fluidized-bed combustor and cross-connect old and new steam turbines. The 120 million dollar project will stabilize the region's electricity rates for many years to come. 10 figs. 1 tab.

20 FOSSIL-FUELED POWER PLANTS↗

Condensate polishers add operating reliability and flexibility

Many of today's advanced steam generators favour either an all-volatile treatment or oxygenated treatment chemistry programme, both of which require strict maintenance of an ultra-pure boiler fedwater ro condensate system. Those requirements are many times at odds with the lower-quality water sources, such as greywater, available for plant makeup and cooling water. Adding a condensate polisher can be a simple, cost-effective solution. 4 figs.

20 FOSSIL-FUELED POWER PLANTS↗

Oh Canada! B.C. ratifies North America's first carbon tax

British Columbia began collecting increased tax revenue on fossil fuels on July 1 with a promise to rebate those taxes through reduced income and business tax rates. This 'revenue recycling' plan makes little progress toward the province's goal to reduce CO{sub 2} emissions 33% by 2020, yet it is hailed by proponents as a legislative milestone. Others believe BC residents are victims of another governmental 'bait and switch' program. This paper examines the legislation. 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Activated carbon injection - a mercury control success story

Almost 100 full-scale activated carbon injection (ACI) systems have been ordered by US electric utilities. These systems have the potential to remove over 90% of the mercury in flue, at a cost below $10,000 per pound of mercury removal. Field trials of ACI systems arm outlined. 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Greenidge multi-pollutant project achieves emissions reduction goals

Performance testing at the Greenridge Multi-Pollutant Project has met or exceeded project goals, indicating that deep emission reduciton sin small, difficult-to-retrofit power plants can be achieved. The technology fitted at the 107 MWe AES Greenridge Unit 4 includes a hybrid selective non-catalytic reduction/selective catalytic reduction system for NOx control (NOxOUT CASCADE) and a Turbosorp circulating fluidized bed dry scrubber system for SO{sub 2}, mercury, SO{sub 3} HC and Hf control. 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Coal-fired power materials

Advances in materials technologies over the last decade that is allowing coal-fired power plants to be built with higher efficiencies than the current generation are described. 2 figs., 2 tabs.

20 FOSSIL-FUELED POWER PLANTS↗

Best of Germany 2008

This supplement discusses German mining equipment and technology under the following sections: mining experience and machinery export; underground mining technology; surface mining technology; materials handling technology; coal and minerals processing technology; power technology; and automation, specialized components and materials. Manufacturers of the different equipment and their contact details are given. 4 figs.

01 COAL, LIGNITE, AND PEAT↗

Air-cooled condensers eliminate plant water use

River or ocean water has been the mainstay for condensing turbine exhaust steam since the first steam turbine began generating electricity. A primary challenge facing today's plant developers, especially in drought-prone regions, is incorporating processes that reduce plant water use and consumption. One solution is to shed the conventional mindset that once-through cooling is the only option and adopt dry cooling technologies that reduce plant water use from a flood to a few sips. A case study at the Astoria Energy plant, New York City is described. 14 figs.

20 FOSSIL-FUELED POWER PLANTS↗

EPA's air program: still hazy after all these years

While the Bush administration is winding down during its final year, several of its major air pollution initiatives have recently unraveled. These casualties were the result of two recent federal court decisions and the Environmental Protection Agency chief's refusal to regulate greenhouse gases under existing laws. These developments make it plain that any important new attempts to regulate air emissions will have to be made by the next president. 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Influence of pH of the impregnation solution on the catalytic properties of Co/{gamma}-alumina for Fischer-Tropsch synthesis

The Co/{gamma}-Al{sub 2}O{sub 3} catalysts were prepared by the slurry impregnation of an aqueous solution of cobalt(II) nitrate precursor. Nitric acid or ammonium hydroxide was added to the cobalt nitrate solution, during impregnation, to give an acidic or basic environment. The changes in the particle size of cobalt species were estimated by X-ray diffraction (XRD) and hydrogen chemisorption. The reduction degree of cobalt oxides was measured by temperature-programmed reduction (TPR). The catalysts prepared under acidic conditions showed a higher reduction degree compared to those prepared at higher pH because of the reduced salt-support interaction. During the Fischer-Tropsch synthesis at 220{sup o}C, employing the catalysts prepared at a different pH (0.80, 4.94, 9.96, and 11.12), a considerable difference in the initial activity was observed, depending upon the cobalt metal surface area. However, after stabilization, all of the catalysts attained a similar level of conversion, possibly because of the active-site rearrangement, deactivation, and wax formation on the catalyst surface. At a higher reaction temperature of 240{sup o}C, the catalysts prepared at lower solution pH exhibited higher conversion than those prepared at higher solution pH. The cobalt species on the catalysts prepared under acidic conditions had a heterogeneous particle size distribution, showing higher steady-state activity, because of the reduced interaction with the support. The product distribution revealed a higher selectivity to C{sub 1} and C{sub 8+} on the catalyst prepared with a higher solution pH. 44 refs., 6 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Comparative study of CO{sub 2} capture by carbon nanotubes, activated carbons, and zeolites

Carbon nanotubes (CNTs), granular activated carbon (GAC), and zeolites were modified by 3-aminopropyl-triethoxysilane (APTS) and were selected as adsorbents to study their physicochemical properties and adsorption behaviors of CO{sub 2} from gas streams. The surface nature of these adsorbents was changed after the modification, which make them adsorb more CO{sub 2} gases. Under the same conditions, the modified CNTs possess the greatest adsorption capacity of CO{sub 2}, followed by the modified zeolites and then the modified GAC. The mechanism of CO{sub 2} adsorption on these adsorbents appears mainly attributable to physical force, which makes regeneration of spent adsorbents at a relatively low temperature become feasible. The APTS-modified CNTs show good performance of CO{sub 2} adsorption as compared to many types of modified carbon and silica adsorbents reported in the literature. This suggests that the APTS-modified CNTs are efficient CO{sub 2} adsorbents and that they possess potential applications for CO{sub 2} capture from gas streams. 27 refs., 11 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

In situ Fourier transform infrared (FTIR) investigation of CO{sub 2} adsorption onto zeolite materials

The adsorption of CO{sub 2} onto five zeolite materials (13X, WEG, AGP, 4A, and 5A) was studied by in situ infrared spectroscopy at 1 atm as a function of the pretreatment temperature (120 and 350{sup o}C) and adsorption temperature (30 and 120{sup o}C). Adsorbed CO{sub 2} surface species identified in the current work include physisorbed CO{sub 2}, bidentate carbonate, bridged bidentate carbonate, monodentate carbonate, and carboxylate. Both pretreatment temperature and CO{sub 2} adsorption temperature affected the type and amount of adsorbed CO{sub 2} species formed. Materials pretreated at 350{sup o}C, as opposed to 120{sup o}C, had more surface adsorption sites available as evidenced from the resulting more intense IR bands. Physisorbed CO{sub 2} was the most abundant species observed. Bridged bidentate carbonate was found to be more stable than bidentate carbonate. Tests involving both CO{sub 2} and H{sub 2}O showed that the two species competed for the same adsorption sites on the zeolite surface. 18 refs., 15 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗