Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Experimental and theoretical investigation of three-dimensional turbulent boundary layers and turbulence characteristics inside an axial flow inducer passage

Analytical and experimental investigations of the characteristics of three dimensional turbulent boundary layers in a rotating helical passage of an inducer rotor are reported. Expressions are developed for the velocity profiles in the inner layer, where the viscous effects dominate, in the outer layer, where the viscous effects are small, and in the interference layer, where the end walls influence the flow. The prediction of boundary layer growth is based on the momentum integral technique. The equations derived are general enough to be valid for all turbomachinery rotors with arbitrary pressure gradients. The experimental investigations are carried out in a flat plate inducer 3 feet in diameter. The mean velocity profiles, turbulence intensities and shear stresses, wall shear stress, and limiting streamline angles are measured at various radial and chordwise locations by using rotating probes. The measurements are in general agreement with the predictions. The radial flows are well represented by an expression which includes the effect of stagger angle and radial pressure gradient. The radial flows in the rotor channel are higher than those on a single blade. The collateral region exists only very near the blade surface. The radial component of turbulence intensity is higher than the streamwise component because of the effect of rotation.

Anand, A. K.↗

Ergometer

The bicycle ergometer was designed for use in experiments M171 and M093 and for use in optional exercise by the crewmen. The ergometer allows a crewman to exercise in zero-gravity using either his hands or his feet. It provides a precisely calibrated and, if needed, a programmable standard of work rate for the crewman. The ergometer operates in any of three selectable modes. The set heart rate mode varies the ergometer work rate, as necessary, to achieve and maintain a preselected heart rate. The sequenced heart rate mode is similar to the set heart rate mode except that the heart rate is programmable through five preset levels with a period of time for each level. The set work rate mode delivers a preset work load to the subject.

Lem, J. D.↗

Spiral approach navigation concepts for VTOL aircraft using a microwave landing system

Spiral approaches adjacent to the active runways of CTOL airports have been proposed as a means of effectively interfacing CTOL and VTOL landing operations. Assuming an airport equipped with a Microwave Landing System (MLS), a VTOL aircraft following a spiral approach path might, depending on the specific trajectory, pass alternatively in and out of the linear coverage of the MLS and thereby suffer degraded navigation performance. The objective of this study was to employ essentially state-of-the-art aided inertial navigation concepts to explore the expected navigation performance operating in the environment just described. Results show that aided inertial concepts utilizing simple body-mounted inertia systems may be adequate for an instrument landing if the MLS azimuth and Distance Measuring Equipment (DME) signal coverages extend to within a few feet of the ground.

Mcgee, L. A.↗

Emergency escape device

Modified egress mechanism used to deploy Lunar Roving Vehicle, could be used in shipping, safety exits, amusement parks, and other applications to gently lower people or equipment several hundred feet.

Burch, J. L.↗

A preliminary study of the performance and characteristics of a supersonic executive aircraft

The impact of advanced supersonic technologies on the performance and characteristics of a supersonic executive aircraft was studied in four configurations with different engine locations and wing/body blending and an advanced nonafterburning turbojet or variable cycle engine. An M 2.2 design Douglas scaled arrow-wing was used with Learjet 35 accommodations. All four configurations with turbojet engines meet the performance goals of 5926 km (3200 n.mi.) range, 1981 meters (6500 feet) takeoff field length, and 77 meters per second (150 knots) approach speed. The noise levels of of turbojet configurations studied are excessive. However, a turbojet with mechanical suppressor was not studied. The variable cycle engine configuration is deficient in range by 555 km (300 n.mi) but nearly meets subsonic noise rules (FAR 36 1977 edition), if coannular noise relief is assumed. All configurations are in the 33566 to 36287 kg (74,000 to 80,000 lbm) takeoff gross weight class when incorporating current titanium manufacturing technology.

Mascitti, V. R.↗

Application of airborne infrared technology to monitor building heat loss

The application of airborne infrared technology to the requirements for energy conservation in buildings was studied. Quantitative airborne data of the City of Ypsilanti, Michigan, were collected and processed to identify roof temperatures. A thermal scanner was flown at an altitude of 1,200 feet with two thermal bands 8.2-9.3 micrometers and 10.4-12.5 micrometers recorded by an analog system. Calibration was achieved by standard hot and cold plates. Using a thermal model to interpret ceiling insulation status, environmental factors were found to influence the relation between roof temperature and insulation. These include interior and sky temperatures, roofing materials, and the pitch and orientation of the roof. A follow-up mail survey established the ability to identify insulated and uninsulated houses from the airborne infrared data.

Tanis, F. J.↗

MSFC hot air collectors. Phase 1: Test report

A development test program of 3 hot air flat plate solar collectors is described in detail. The pressure drop versus flow rate performance characteristics for these collectors, mounted in series, was determined under 14 different test conditions each of which was characterized by a unique combination of inlet air temperature and air flow rate. Characteristics of inlet, exit and transfer ducts of these collectors were also determined during this testing. The test results indicate that significant pressure drop occurs at air flow rates greater than 150 standard cubic feet per minute and this drop is not heavily dependent upon inlet air temperature; and inlet, exit and transfer duct characteristics differ sufficiently to suggest that system performance may be enhanced through careful design of each type of duct individually.

Losey, R.↗

Collation of quarterly reports on air flat plate collectors

The solar 2 air flat plate collectors are described. The development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet of collector area are described. Three instrumented panels were completely assembled with glazing and insulation. Manufacture of the last seven prototype collectors was completed in October 1977.

Source record↗

Certain peculiarities of the functioning of the cardiovascular system in bedrest conditions during horizontal and antiorthostatic body positions

The adequate modeling of physiological reactions inherent to the state of weightlessness has become a matter of particular urgency in space medicine. This modeling is necessary for studying the phenomenology and degree of disorders, prognostication of the crew's health, and developing the various preventive measures employed in space flights. A comparison is made of the physiological effects brought about by bed rest in a horizontal and antiorthostatic body position. A study is done of the influence of brief antiorthostatic hypokinesia, simulating the acute period of adaptation to weightlessness, on circulation and on a number of involved analytical systems. The basic model accepted is antiorthostatic hypokinesia with a body position declination angle of 4 deg (head lower than feet). The experiment's duration is dictated by the objectives of the research.

Source record↗

Preliminary design review package on air flat plate collector for solar heating and cooling system

Guidelines to be used in the development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet (10-4 ft x 8 ft panels) of collector area are presented. Topics discussed include: (1) verification plan; (2) thermal analysis; (3) safety hazard analysis; (4) drawing list; (5) special handling, installation and maintenance tools; (6) structural analysis; and (7) selected drawings.

Source record↗

Test report for twinax cable (Rockwell type MB0150-051)

A controlled impedance twisted pair shielded cable was tested to determine the frequency response and effects of mismatched termination. It was found that a long length of this cable, about 100 feet, exhibited a frequency sensitive attenuation roll-off greater than 1.5 db down at 5 MHz. It was also determined that improper termination resulted in losses of 1/2 to 1 db within the frequency range of 200 KHz to greater than 1-1/2 MHz. The test results indicate a possible problem where mismatched connectors are used in video signal cables.

Doland, G. D.↗

The production of ultrathin polyimide films for the solar sail program and Large Space Structures Technology (LSST): A feasibility study

Polyimide membranes of a thickness range from under 0.01 micron m to greater than 1 micron m can be produced at an estimated cost of 50 cents per sq m (plus the cost of the polymer). The polymer of interest is dissolved in a solvent which is solube in water. The polymer or casting solution is allowed to flow down an inclined ramp onto a water surface where a pool of floating polymer develops. The solvent dissolves into the water lowering the surface tension of the water on equently, the contact angle of the polymer pool is very low and the edge of the pool is very thin. The solvent dissolves from this thin region too rapidly to be replenished from the bulk of the pool and a solid polymer film forms. Firm formation is rapid and spontaneous and the film spreads out unaided, many feet from the leading edge of the pool. The driving force for this process is the exothermic solution of the organic solvent from the polymer solution into the water.

Forester, R. H.↗

Computer processing of SAR L-band imagery

The described work in the areas of hydrology and polar ice defines possible uses of automatic picture processing of uncalibrated radar images. The data used in the study were collected with the aid of an L-band synthetic aperture radar mounted in the NASA CV-990 aircraft. The radar was operated at approximately 30,000 feet altitude. One study area used was located in the Beaufort Sea and contained sea ice. The other study area contained lakes on the Alaskan North Slope. The reported investigations demonstrate that certain types of features can be efficiently studied by using simple automatic picture processing techniques applied to uncalibrated radar data.

Bryan, M. L.↗

A search for ultraviolet OH emission from meteors

Observations of hydroxyl (OH) emission from meteors were made during the late summers of 1975 and 1976 from altitudes of 10,600 and 14,200 feet (3.2 km and 4.45 km). The observations were made with OH meteor photometers developed at the NASA-Langley Research Center. Two of the meteors were Perseids, and one was an Alpha Capricornid. The Perseid meteors produced a peak irradiance at a distance of 100 km from the meteors of about 0.00005 erg/sq cm per sec in the OH emission region. The zero-magnitude Alpha Capricornid meteor produced a spectral irradiance at 3100 A of 23 hundred-millionths erg/sq cm per A per sec. This may be indicative of significant amounts of H2O in these meteors.

Harvey, G. A.↗

NASA laser tracker

Beginning in July of 1976, flight tests have been on the Microwave Scanning Beam Landing System (MSBLS) built for NASA. The MSBLS is designed to supply accurate guidance information to the Space Shuttle as it returns from orbit to an aircraft-type runway. Because of the broad coverage (30 by 30 degrees) and high accuracy (0.05 degree in angle, 100 feet in range) of the MSBLS, a flexible reference system with higher accuracy was required. The laser tracker has been fulfilling this requirement.

Perkins, H.↗

Shuttle carrier aircraft flight tests

Since the Space Shuttle will need to be transported from its place of assembly to the launch site, a method has been developed whereby the Shuttle rides piggyback on a modified Boeing 747, called the Shuttle carrier aircraft (SCA). This paper describes tests of the SCA in its mated configuration. Tests include: flutter, found to decrease when fiberglass and wood fairings were added to the base of each supporting pylon; stability and control, found to be acceptable after damping with control pulses; noise and buffet, found high but acceptable; and climb, in which drag was marked but acceptable with the special rated thrust (SRT) power setting. Simulated launch maneuvers were undertaken at an airspeed of 273 KCAS. Transport of the Shuttle takes place with the Shuttle tail cone on, at a cruise speed of 288 KCAS at an altitude of 22,000 feet.

Fulton, F. L., Jr.↗

Aircraft measurement of radio frequency noise at 121.5 MHz, 243MHz and 406MHz

An airborne survey measurement of terrestrial radio-frequency noise over U.S. metropolitan areas has been made at 121.5, 243 and 406 MHz with horizontal-polarization monopole antennas. Flights were at 25,000 feet altitude during the period from December 30, 1976 to January 8, 1977. Radio-noise measurements, expressed in equivalent antenna-noise temperature, indicate a steady-background noise temperature of 572,000 K, at 121.5 MHz, during daylight over New York City. This data is helpful in compiling radio-noise temperature maps; in turn useful for designing satellite-aided, emergency-distress search and rescue communication systems.

Taylor, R. E.↗