At least 1,441 records · Page 80

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large-Scale Commercial Carbon Capture Retrofit of the San Juan Generating Station

Enchant Energy, L.L.C. (Enchant) was selected to conduct a Front-End Engineering Design study (FEED) for the addition of a full-scale carbon capture system to remove carbon dioxide from the flue gas emissions of the two coal-fired generating units (total of 847 MW net) at San Juan Generating Station (SJGS), using Mitsubishi Heavy Industries Americas (MHIA) KM CDR Process™. Sargent & Lundy LLC (S&L) was selected as the primary technical lead, and along with various other organizations, were able to support Enchant’s completion of the following FEED tasks: Task 1 – Project Management & Planning; Task 2 – FEED Study; Task 3 - Final FEED Study Package. The FEED study period was between October 15, 2019 to September 30, 2022.

01 COAL, LIGNITE, AND PEAT↗

Mercury Speciation During Vitrification of LAW

n this work, laboratory and engineering-scale tests were conducted that mimic the reactive environment of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) low activity waste (LAW) melter and off-gas system in order to assess the speciation of mercury at select points in the processing system. The experimental protocols, test equipment, feed materials used, and rationale for testing are detailed in the Test Plan for this work. Particular attention was paid to the amount and speciation of mercury in submerged bed scrubber (SBS) solutions, which are intended to be recycled back to the melter feed at the WTP. Results are presented from detailed mercury analysis of these solutions using Environmental Protection Agency (EPA) Method 1630 and modifications to this method for dimethyl mercury and methyl mercury as well as EPA Method 1631 and modifications to this method for total, dissolved, elemental, suspended, and ionic mercury. Testing was conducted in two separate sets of experiments: (1) One set of tests (crucible-scale furnace tests) that involved heating small batches of mercury-spiked melter feed in crucibles to determine the amount of mercury retained in the glass and the species of mercury in the exhaust gases; (2) A second set of tests (DM10 melter tests) was planned that involved creating LAW melter plenum gas compositions using the DM10 melter system, injecting mercury into the off-gas stream, and passing that stream though a reactor that simulates various plenum gas conditions. Operational issues led to the need to use one of the VSL DM100 melters in place of the planned DM10 melter for these tests. The speciation of mercury after exposure to those conditions was monitored. In both sets of tests, the exhaust gases were run through a scrubber that was intended to mimic the LAW SBS in order to determine how much of the mercury exiting the melter would be retained in the primary off-gas system fluids and in what form. After passing through the SBS, the exhaust stream was analyzed to determine particulate, ionic, elemental, and total mercury passing downstream of the SBS. In tests employing gases derived from the DM100 melter that were spiked with elemental mercury, the processing system provided gas temperatures and residence times that are representative of the WTP LAW vitrification system in order to assess the effect of those conditions on mercury speciation. The Decontamination Factor (DF) across the system in the tests with mercury-spiked DM100 melter exhaust was determined using the analytical data from EPA Method 30B (Fluegas Adsorption Mercury Speciation (FAMS TM )) exhaust samples and the amount of mercury detected in the SBS solutions. Mercury species used in melter feed crucible scale tests were divalent (chloride and iodide), monovalent (chloride and fluoride), and elemental mercury. Individual tests included only a single form of mercury in the feed. The results for total mercury mass balances in the crucible tests are also presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spent Crystalline Silicotitanate Storage Study

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable. The testing described herein looks to potential upset process conditions where CST storage may be required before various rinse steps are completed. This study evaluated upset conditions at three sequential processing steps envisioned for TSCR (feed, 0.1 M NaOH rinse, water rinse), and in-column drying with compressed air (normal end step) to assess impacts on the nature of the CST bed. Testing was conducted at the small scale (12-mL bed volume); simulated AP-105 tank waste was used as the feed. Following process disruption, the CST bed was dried in place at 70 °C. Post-dried CST bed physical properties (angle of repose, penetration depth, particle morphological changes) were measured to evaluate how CST moved and flowed. The testing is intended to provide a preliminary assessment of issues that may arise from desiccation of CST with the indicated salt solutions in place. Since these were small-scale tests, the processing conditions will not match full scale conditions exactly; however, the tests do provide insight into the impact of stopping processing at an earlier step than normal. Except for the feed that was dried in-place, all other process stop-conditions showed the CST bed flowed well after drying. At this small scale, CST beds would not present an issue for retrievability. The feed that was dried in place had solidified into a rock-hard monolith with no movement possible. Samples had to be chipped from the surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U-gas +Cool GTL™ - A New Integrated Process for Direct Biomass Conversion to Liquid Fuels

The U-Gas gasification technology, marketed by Sungas, is a proven fluid bed gasification technology for biomass conversion. U-Gas has been tested on a wide variety of biomass feeds including wood and waste streams. The U-Gas Technology has successfully converted wood for more than 20 years in a gasification plant in Skive Denmark at the 150t/d size. GTI has also recently developed the Cool GTL process for converting biogas to high quality gasoline, jet, and diesel fuels. The technoeconomics and LCA for the combination of the two technologies results an integrated optimized process, which will be discussed. The Cool GTL process is still in development and the development should be complete by 2023. Cool GTL converts high CO2 content feeds to synthesis gas with a 2-2.4/1 H2/CO ratio suitable for fuels synthesis. The process is based on a novel, highly stabile CO2/steam reforming catalyst. The 2.0-2.4/1 H2/CO synthesis gas ratio is always achieved, independently of feed CO2 content, by adjusting the amount of water added according to the amount of CO2 in the feed. The reformer catalyst has been tested for 500 hours and shows no measurable deactivation. The product from the reformer then goes directly to a low temperature slurry bed Fischer Tropsch reactor with an integrated finishing hydroisomerization reactor which makes hydrocarbon liquids from the synthesis gas. With this configuration no wax is produced. The technoeconomics and carbon intensity for the integration of UGas and the Cool GTL processes will be compared to other biomass conversion approaches. The use of electrolysis to boost H2 in the feed and increase liquid production will also be analyzed as a potential process improvement with sensitivities to the cost of electricity and the use of renewable electricity.

09 BIOMASS FUELS↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of the Form of Iron on HLW Melt Rate

The primary objective of the work reported herein was to determine the effect of the form of iron in the HLW stream on feed processing rate. Secondary objectives were to determine the effect of iron form on feed properties, glass properties, and carryover from the melter during vitrification. This was accomplished by replacing the Fe(OH) 3 used in a previously tested simulant for C-106/AY-102 actual waste with either goethite (FeO(OH)), hematite (Fe 2 O 3 ), magnetite (Fe 3 O 4 ), or a mixture of iron oxides, and processing the resulting melter feeds on the DM100 melter system. Glass forming additives were combined with the high iron simulant to produce melter feed targeting the HLW-NG-Fe2 glass composition. Melter feed samples also underwent testing for rheological properties and processing rate using a VGF system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulated Waste for Leaching and Filtration Studies--Laboratory Preparation Procedure

This report discusses the simulant preparation procedure for producing multi-component simulants for leaching and filtration studies, including development and comparison activities in accordance with the test plan( ) prepared and approved in response to the Test Specification 24590-WTP-TSP-RT-06-006, Rev 0 (Smith 2006). A fundamental premise is that this approach would allow blending of the different components to simulate a wide variety of feeds to be treated in the Hanford Tank Waste Treatment and Immobilization Plant (WTP). For example, a given feed from the planned feed vector could be selected, and the appropriate components would then be blended to achieve a representation of that particular feed. Using the blending of component simulants allows the representation of a much broader spectrum of potential feeds to the Pretreatment Engineering Platform (PEP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DWPF COAL-CARBON WASTE ACCEPTANCE CRITERIA LIMIT EVALUATION BASED ON EXPERIMENTAL WORK (TANK 48 IMPACT STUDY)

This report summarizes the results of both experimental and modeling studies performed using Sludge Batch 10 (SB10) simulants and FBSR product from Tank 48 simulant testing in order to develop higher levels of coal-carbon that can be managed by DWPF. Once the Fluidized Bed Steam Reforming (FBSR) process starts up for treatment of Tank 48 legacy waste, the FBSR product stream will contribute higher levels of coal-carbon in the sludge batch for processing at DWPF. Coal-carbon is added into the FBSR process as a reductant and some of it will be present in the FBSR product as unreacted coal. The FBSR product will be slurried in water, transferred to Tank Farm and will be combined with sludge and washed to produce the sludge batch that DWPF will process. The FBSR product is high in both water soluble sodium carbonate and unreacted coal-carbon. Most of the sodium carbonate is removed during washing but all of the coal-carbon will remain and become part of the DWPF sludge batch. A paper study was performed earlier to assess the impact of FBSR coal-carbon on the DWPF Chemical Processing Cell (CPC) operation and melter off-gas flammability by combining it with SB10-SB13. The results of the paper study are documented in Ref. 7 and the key findings included that SB10 would be the most difficult batch to process with the FBSR coal present and up to 5,000 mg/kg of coal-carbon could be fed to the melter without exceeding the off-gas flammability safety basis limits. In the present study, a bench-scale demonstration of the DWPF CPC processing was performed using SB10 simulants spiked with varying amounts of coal, and the resulting seven CPC products were fed to the DWPF melter cold cap and off-gas dynamics models to determine the maximum coal that can be processed through the melter without exceeding the off-gas flammability safety basis limits. Based on the results of these experimental and modeling studies, the presence of coal-carbon in the sludge feed to DWPF is found to have both positive (+) and negative (-) impact as summarized below: (-) Coal-carbon is a melter reductant. If excess coal-carbon is present, the resulting melter feed may be too reducing, potentially shortening the melter life. During this study, the Reduction/Oxidation Potential (REDOX) of the melter could be controlled by varying the ratio of nitric and formic acid. (-) The addition of coal-carbon increases the amount of nitric acid added and decreases the amount of formic acid added to control melter REDOX. This means that the CPC with the FBSR product is much more oxidizing than current CPC processing. In this study, adequate formic acid was present in all experiments to reduce mercury and manganese, two of the main goals of CPC processing. (-) Coal-carbon will be oxidized to carbon dioxide or carbon monoxide in the melter. The addition of coal-carbon to the FBSR product will lead to approximately 55% higher offgas production from formate, nitrate and carbon due to the decomposition of the carbon at the maximum levels in this testing. Higher offgas production could lead to higher cold cap coverage or melter foaming which could decrease melt rate. No testing was performed to evaluate the impact of the higher melter offgas flow. (+) The hydrogen production is greatly reduced in testing with coal as less formic acid is added in CPC processing. In the high acid run without coal, the peak hydrogen generation was 15 times higher than in the high acid run with added coal-carbon. (+) Coal-carbon is a less problematic reducing agent than formic acid, since the content of both carbon and hydrogen are important in evaluating the flammability of the melter offgas. Processing with coal-carbon decreases the amount of formic acid added in the CPC, leading to a lower flammability risk in processing with coal-carbon compared to the current DWPF flowsheet. (+) The seven SB10 formulations which were tested during the bench-scale CPC demonstration were all determined to be within the off-gas flammability safety basis limits during the 9X/5X off-gas surge for normal bubbled melter operation. The concentration of coal-carbon in these baseline melter feeds varied widely from 0 to 17,863 ppm, depending on the acid addition strategy used and the extent to which the required reductant (formic acid) was replaced with coal-carbon. All baseline feeds were redox-adjusted and three of them contained TOC higher than the current theoretical TSR limit of 18,900 ppm. (-) Additional coal-carbon was then added to each baseline feed until the calculated off-gas flammability equaled the safety basis limit of 60% of the LFL at the peak of off-gas surge ('max-coal'). In doing so, however, no counterbalancing nitrate was added, thus simulating the scenario where slugs of coal enter the melter as a result of uneven distribution of coal in the slurry.

01 COAL, LIGNITE, AND PEAT↗

A new type of defatted green microalgae exerts dose-dependent nutritional, metabolic, and environmental impacts in broiler chicks

The potential of defatted microalgae from biofuel production in animal feeding remains unclear. The objective of this experiment was to determine the metabolic and environmental impacts of a defatted green microalgal biomass (DGA, Nannochloropsis oceanica, Cellana, Kailua-Kona, HI) in broiler chick diets. Day-old chicks (total = 180) were fed the control diet containing zero, 2, 4, 8, or 16% of DGA for 6 wk to determine the optimal level of DGA inclusion. Compared with chicks fed the control diet, only those fed the 16% DGA diet had lower (P < 0.05) ADG and feed use efficiency. The DGA feeding produced dose-dependent (linear) increases in starter period water intake (P < 0.0001, R 2 = 0.76) and in wk 6 relative weights of heart (P < 0.0001, R 2 = 0.45), liver (P = 0.09, R 2 = 0.19), and intestinal tract (P = 0.02, R 2 = 0.19), retentions of soluble inorganic phosphorus (P = 0.001, R 2 = 0.39) and DNA retention (P = 0.001, R 2 = 0.46), and ileal DNA content (P < 0.0001, R 2 = 0.50). Meanwhile, the DGA feeding led to weak linear decreases (P < 0.05, R 2 = 0.14 to 0.27) in wk 6 tibia weight and length and excretion of soluble inorganic phosphorus. In contrast, the DGA feeding did not affect relative weights of breast, proventriculus, or gizzard, tibial bone strength, or plasma DNA concentrations. In conclusion, this new type of DGA biomass may be supplemented into diets for broilers at 8% without adverse effects if the salt content is decreased.

59 BASIC BIOLOGICAL SCIENCES↗

Methane and Ethane Steam Reforming over MgAl2O4-Supported Rh and Ir Catalysts: Catalytic Implications for Natural Gas Reforming Application

Solar concentrators employed in conjunction with highly efficient micro- and meso-channel reactors offer the potential for cost-effective upgrading of the energy content of natural gas, providing a near-term path towards a future solar-fuel economy with reduced carbon dioxide emissions. To fully exploit the heat and mass transfer advantages offered by micro- and meso-channel reactors, highly active and stable natural gas steam reforming catalysts are required. In this paper, we report the catalytic performance of MgAl2O4-supported Rh (5 wt.%), Ir (5 wt.%), and Ni (15 wt.%) catalysts used for steam reforming of natural gas. Both Rh- and Ir-based catalysts are known to be more active and durable than conventional Ni-based formulations, and recently Ir has been reported to be more active than Rh for methane steam reforming on a turnover basis. Thus, the effectiveness of all three metals to perform natural gas steam reforming was evaluated in this study. Here, the Rh- and Ir-supported catalysts both exhibited higher activity than Ni for steam methane reforming. However, using simulated natural gas feedstock (94.5% methane, 4.0% ethane, 1.0% propane, and 0.5% butane), the Ir catalyst was the least active (on a turnover basis) for steam reforming of higher hydrocarbons (C2+) contained in the feedstock when operated at <750 °C. To further investigate the role of higher hydrocarbons, we used an ethane feed and found that hydrogenolysis precedes the steam reforming reaction and that C–C bond scission over Ir is kinetically slow compared to Rh. Catalyst durability studies revealed the Rh catalyst to be stable under steam methane reforming conditions, as evidenced by two 100-hour duration experiments performed at 850 and 900 °C (steam to carbon [S/C] molar feed ratio = 2.0 mol). However, with the natural gas simulant feed, the Rh catalyst exhibited catalyst deactivation, which we attribute to coking deposits derived from higher hydrocarbons contained in the feedstock. Increasing the S/C molar feed ratio from 1.5 to 2.0 reduced the deactivation rate and stable catalytic performance was demonstrated for 120 h when operated at 850 °C. However, catalytic deactivation was observed when operating at 900 °C. While improvements in steam reforming performance can be achieved through choice of catalyst composition, this study also highlights the importance of considering the effect of higher hydrocarbons contained in natural gas, operating conditions (e.g., temperature, S/C feed ratio), and their effect on catalyst stability. The results of this study conclude that a Rh-supported catalyst was developed that enables very high activities and excellent catalytic stability for both the steam reforming of methane and other higher hydrocarbons contained in natural gas, and under conditions of operation that are amendable to solar thermochemical operations.

03 NATURAL GAS↗

The Ingestion of Fluorescent, Magnetic Nanoparticles for Determining Fluid-uptake Abilities in Insects

Here, fluid-feeding insects ingest a variety of liquids, which are present in the environment as pools, films, or confined to small pores. Studies of liquid acquisition require assessing mouthpart structure and function relationships; however, fluid uptake mechanisms are historically inferred from observations of structural architecture, sometimes unaccompanied with experimental evidence. Here, we report a novel method for assessing fluid-uptake abilities with butterflies (Lepidoptera) and flies (Diptera) using small amounts of liquids. Insects are fed with a 20% sucrose solution mixed with fluorescent, magnetic nanoparticles from filter papers of specific pore sizes. The crop (internal structure used for storing fluids) is removed from the insect and placed on a confocal microscope. A magnet is waved by the crop to determine the presence of nanoparticles, which indicate if the insects are able to ingest fluids. This methodology is used to reveal a widespread feeding mechanism (capillary action and liquid bridge formation) that is potentially shared among Lepidoptera and Diptera when feeding from porous surfaces. In addition, this method can be used for studies of feeding mechanisms among a variety of fluid-feeding insects, including those important in disease transmission and biomimetics, and potentially other studies that involve nano- or micro-sized conduits where liquid transport requires verification.

36 MATERIALS SCIENCE↗

Selectable polarization at X-band

The X-band feeds in the Deep Space Network were upgraded to include selectable polarization in time for the Voyager missions to the outer planets. The modified antenna feed has the following major items added: two circular waveguide rotary joints, drive motor and gear reducer, gear assembly, two microswitches, and a polarization control junction box. The overall length of the feed remains the same because circular waveguide spacing sections were designed into the original feed to readily permit such modifications. There is no significant increase in antenna noise temperature compared to the original feed.

Hartop, R. W.↗

Shuttle orbiter Ku-band radar/communications system design evaluation: High gain antenna/widebeam horn

The physical characteristics of the high gain antenna reflector and feed elements are described. Deficiencies in the sum feed are discussed, and lack of atmospheric venting is posed as a potential problem area. The measured RF performance of the high gain antenna is examined and the high sidelobe levels measured are related to the physical characteristics of the antenna. An examination of the attributes of the feed which might be influenced by temperature extremes shows that the antenna should be insensitive to temperature variations. Because the feed support bipod structure is considered a significant contributor to the high sidelobe levels measured in the azimuth plane, pod relocation, material changes, and shaping are suggested as improvements. Alternate feed designs are presented to further improve system performance. The widebeam horn and potential temperature effects due to the polarizer are discussed as well as in the effects of linear polarization on TDRS acquisition, and the effects of circular polarization on radar sidelobe avoidance. The radar detection probability is analyzed as a function of scan overlap and target range.

Iwasaki, R.↗

Modeling of flexible structures for active control

If a flexible structure has a plane of symmetry, the equations of motion can be split into two uncoupled sets, one for symmetrical motions and one for anti-symmetric motions. If there are m controls, it is often convenient to assign the linear combinations of controls that enter into the m lowest frequency modes and new controls. As an example the feed-support structure of a spacecraft antenna is considered. It is modeled as a tetrahedron made up of flexible bars and connected to the spacecraft by six short flexible legs containing force actuators and displacement sensors. Due to the three-sided symmetry of this structure, both the symmetric and the anti-symmetric equations of motion can be decoupled into two subsystems. The resulting four subsystems are: (1) pitch/fore-aft motions with four degrees of freedom (DOF), two controls, and one output (the fore-aft motion of the feed); (2) vertical motions with three DOF, one control, and one output (the vertical motion of the feed); (3) roll/lateral motions with four DOF, two controls, and one output (the lateral motions of the feed); and (4) yaw motion with one DOF, one control, and no output (the feed does not move during yaw motion).

Bryson, A. E., Jr.↗

Paraboloidal Antenna Radiates Fan Or Pencil Beams

Shape of beam determined by type of feed. Theory and experiments show same paraboloidal antenna reflector used to radiate pencil beam or fan beam, depending on configuration of feed. Although pencil-shaped beam desirable in many applications, fan-shaped beam preferred in some scanning-radar and mapping-radar systems. Experiment performed with paraboloidal reflector having focal length of 48 in. (1.22 m) and diameter of 3.65 m. Shows fan beams generated in this way and not seriously distorted by feed offsets tested. Also shows because reflector in near field of feed, fan beam not necessarily focused by placing feed at focal plane.

Huang, John↗

Geometrical optics design of a compact range Gregorian subreflector system by the principle of the central ray

In recent years, the compact range has become very popular for measuring Radar Cross Section (RCS) and antenna patterns. The compact range, in fact, offers several advantages due to reduced size, a controlled environment, and privacy. On the other hand, it has some problems of its own, which must be solved properly in order to achieve high quality measurement results. For example, diffraction from the edges of the main reflector corrupts the plane wave in the target zone and creates spurious scattering centers in RCS measurements. While diffraction can be minimized by using rolled edges, the field of an offset single reflector compact range is corrupted by three other errors: the taper of the reflected field, the cross polarization introduced by the tilt of the feed and the aperture blockage introduced by the feed itself. These three errors can be eliminated by the use of a subreflector system. A properly designed subreflector system offers very little aperture blockage, no cross-polarization introduced and a minimization of the taper of the reflected field. A Gregorian configuration has been adopted in order to enclose the feed and the ellipsoidal subreflector in a lower chamber, which is isolated by absorbers from the upper chamber, where the main parabolic reflector and the target zone are enclosed. The coupling between the two rooms is performed through a coupling aperture. The first cut design for such a subreflector system is performed through Geometrical Optics ray tracing techniques (GO), and is greatly simplified by the use of the concept of the central ray introduced by Dragone. The purpose of the GO design is to establish the basic dimensions of the main reflector and subreflector, the size of the primary and secondary illuminating surfaces, the tilt angles of the subreflector and feed, and estimate the feed beamwidth. At the same time, the shape of the coupling aperture is initially determined.

Clerici, Giancarlo↗