Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Wake Geometry Measurements and Analytical Calculations on a Small-Scale Rotor Model

An experimental investigation was conducted in the Langley 14- by 22-Foot Subsonic Tunnel to quantify the rotor wake behind a scale model helicopter rotor in forward level flight at one thrust level. The rotor system in this test consisted of a four-bladed fully articulated hub with blades of rectangular planform and an NACA 0012 airfoil section. A laser light sheet, seeded with propylene glycol smoke, was used to visualize the vortex geometry in the flow in planes parallel and perpendicular to the free-stream flow. Quantitative measurements of wake geometric proper- ties, such as vortex location, vertical skew angle, and vortex particle void radius, were obtained as well as convective velocities for blade tip vortices. Comparisons were made between experimental data and four computational method predictions of experimental tip vortex locations, vortex vertical skew angles, and wake geometries. The results of these comparisons highlight difficulties of accurate wake geometry predictions.

Ghee, Terence A.↗

Sputtering of Surfaces by Ion Irradiation: A Comparison of Molecular Dynamics and Binary Collision Approximation Models to Laboratory Measurements

We compare various sputtering simulation methods to experimental results in both the low energy (<1 keV) and high energy (≥1 keV) impact regimes for argon ions impacting a pure copper substrate at normal incidence. Our results indicate that for high energy impacts, both binary collision approximation (BCA) and molecular dynamics methods can be used to generate reasonable predictions for the yield and energy distribution of the sputtered atoms. We also find reasonable agreement between the theoretical and experimental results down to impact energies of 600 eV. However, at 200 eV impact energies, significant discrepancies appear between the experimental and theoretical ejecta energy distributions in the peak position, the width of the energy distribution, and the magnitude of the high energy tail. These discrepancies appear to arise from the experimental results being only for atoms sputtered normal to the substrate surface, whereas the theoretical results are integrated over all 2π solid angles above the surface. Using the BCA code SDTrimSP and limiting the results to only atoms emitted within ±15° of the surface normal brings theory and experiment into reasonable agreement. These results suggest that for low energy impacts, the energy distribution of sputtered atoms is highly dependent on the emission angle of the ejecta.

Solar wind↗

Computational Modeling of Micrometastatic Breast Cancer Radiation Dose Response

Purpose: Prophylactic cranial irradiation (PCI) involves giving radiation to the entire brain with the goals of reducing the incidence of brain metastasis and improving overall survival. Experimentally, we have demonstrated that PCI prevents brain metastases in a breast cancer mouse model. We developed a computational model to expand on and aid in the interpretation of our experimental results. Methods and Materials: MATLAB was used to develop a computational model of brain metastasis and PCI in mice. Model input parameters were optimized such that the model output would match the experimental number of metastases per mouse from the unirradiated group. An independent in vivo–limiting dilution experiment was performed to validate the model. The effect of whole brain irradiation at different measurement points after tumor cells were injected was evaluated in terms of the incidence, number of metastases, and tumor burden and was then compared with the corresponding experimental data. Results: In the optimized model, the correlation between the number of metastases per mouse and the experimental fits was >95. Our attempt to validate the model with a limiting dilution assay produced 99.9% correlation with respect to the incidence of metastases. The model accurately predicted the effect of whole-brain irradiation given 3 weeks after cell injection but substantially underestimated its effect when delivered 5 days after cell injection. The model further demonstrated that delaying whole-brain irradiation until the development of gross disease introduces a dose threshold that must be reached before a reduction in incidence can be realized. Conclusions: Our computational model of mouse brain metastasis and PCI correlated strongly with our experiments with unirradiated mice. The results further suggest that early treatment of subclinical disease is more effective than irradiating established disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observable consequences of event-by-event fluctuations of HBT radii

We explore the effects of event-by-event fluctuations of Hanbury Brown–Twiss (HBT) radii and show how they can be observed experimentally. The relation of measured HBT radii extracted from ensemble-averaged correlation functions to the mean of their event-by-event probability distribution is clarified. Here, we propose a method to experimentally determine the mean and variance of this distribution and test it on an ensemble of fluctuating events generated with the viscous hydrodynamic code VISH2+1. Using the same code, the sensitivity of the mean and variance of the HBT radii to the specific QGP shear viscosity $\eta$/s is studied. We report sensitivity of the mean pion HBT radii and their variances to the temperature dependence of \eta/s near the quark-hadron transition at a level similar (10-20%) to that which was previously observed for elliptic and quadrangular flow of charged hadrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scalable measurement error mitigation via iterative bayesian unfolding

Measurement errors are a significant obstacle to achieving scalable quantum computation. To counteract systematic readout errors, researchers have developed postprocessing techniques known as measurement error mitigation methods. However, these methods face a tradeoff between scalability and returning nonnegative probabilities. In this paper, we present a solution to overcome this challenge. Our approach focuses on iterative Bayesian unfolding, a standard mitigation technique used in high-energy physics experiments, and implements it in a scalable way. We demonstrate our method on experimental Greenberger-Horne-Zeilinger state preparation on up to 127 qubits and on the Bernstein-Vazirani algorithm on up to 26 qubits. Compared to state-of-the-art methods (such as M3), our implementation guarantees valid probability distributions, returns comparable or better-mitigated results, and does so without a noticeable time and memory overhead. Published by the American Physical Society 2024

Pokharel, Bibek (ORCID:0000000342841353)↗

Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction

Purpose: A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. Methods: EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Results: Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. Conclusions: A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method.

60 APPLIED LIFE SCIENCES↗

SU-E-T-491: Importance of Energy Dependent Protons Per MU Calibration Factors in IMPT Dose Calculations Using Monte Carlo Technique

Purpose: In intensity modulated proton therapy (IMPT), energy dependent, protons per monitor unit (MU) calibration factors are important parameters that determine absolute dose values from energy deposition data obtained from Monte Carlo (MC) simulations. Purpose of this study was to assess the sensitivity of MC-computed absolute dose distributions to the protons/MU calibration factors in IMPT. Methods: A “verification plan” (i.e., treatment beams applied individually to water phantom) of a head and neck patient plan was calculated using MC technique. The patient plan had three beams; one posterior-anterior (PA); two anterior oblique. Dose prescription was 66 Gy in 30 fractions. Of the total MUs, 58% was delivered in PA beam, 25% and 17% in other two. Energy deposition data obtained from the MC simulation were converted to Gy using energy dependent protons/MU calibrations factors obtained from two methods. First method is based on experimental measurements and MC simulations. Second is based on hand calculations, based on how many ion pairs were produced per proton in the dose monitor and how many ion pairs is equal to 1 MU (vendor recommended method). Dose distributions obtained from method one was compared with those from method two. Results: Average difference of 8% in protons/MU calibration factors between method one and two converted into 27 % difference in absolute dose values for PA beam; although dose distributions preserved the shape of 3D dose distribution qualitatively, they were different quantitatively. For two oblique beams, significant difference in absolute dose was not observed. Conclusion: Results demonstrate that protons/MU calibration factors can have a significant impact on absolute dose values in IMPT depending on the fraction of MUs delivered. When number of MUs increases the effect due to the calibration factors amplify. In determining protons/MU calibration factors, experimental method should be preferred in MC dose calculations. Research supported by National Cancer Institute grant P01CA021239.

60 APPLIED LIFE SCIENCES↗

Excited state lifetime modulation in semiconductor nanocrystals for super-resolution imaging

Abstract We report on proof of principle measurements of a concept for a super-resolution imaging method that is based on excitation field density-dependent lifetime modulation of semiconductor nanocrystals. The prerequisite of the technique is access to semiconductor nanocrystals with emission lifetimes that depend on the excitation intensity. Experimentally, the method requires a confocal microscope with fluorescence-lifetime measurement capability that makes it easily accessible to a broad optical imaging community. We demonstrate with single particle imaging that the method allows one to achieve a spatial resolution of the order of several tens of nanometers at moderate fluorescence excitation intensity.

36 MATERIALS SCIENCE↗

Increase of the electron mobility in HEMT heterostructures with composite spacers containing AlAs nanolayers

The effect of the hybridization of quantum states on electron transport in a two-barrier quantum well δ-doped through a spacer layer at the limit of heavy doping is shown theoretically and experimentally. A method for increasing the electron mobility in the quantum well by suppressing the tunnel coupling with the donor region through the introduction of an AlAs nanobarrier into the spacer layer is proposed. It is experimentally shown that, in the samples with a shallow quantum well, the AlAs nanobarrier introduced into the spacer layer provides a larger than threefold increase in the electron mobility at low temperatures.

36 MATERIALS SCIENCE↗

Quadratic optimal cooperative control synthesis with flight control application

An optimal control-law synthesis approach is presented that involves simultaneous solution for two cooperating controllers operating in parallel. One controller's structure includes stochastic state estimation and linear feedback of the state estimates, while the other controller involves direct linear feedback of selected system output measurements. This structure is shown to be optimal under the constraint of linear feedback of system outputs in one controller. Furthermore, it is appropriate for flight control synthesis where the full-state optimal stochastic controller can be adjusted to be representative of an optimal control model of the human pilot in a stochastic regulation task. The method is experimentally verified in the case of the selection of pitch-damper gain for optimum pitch tracking, where optimum implies the best subjective pilot rating in the task. Finally, results from application of the method to synthesize a controller for a multivariable fighter aircraft are presented, and implications of the results of this method regarding the optimal plant dynamics for tracking are discussed.

Schmidt, D. K.↗

University Data Management Pilot Utilizing the Nuclear Research Data System

Background In 2022, the Office of Science and Technology Policy (OSTP) issued a memo that significantly reshaped the landscape of access to federally funded research. The memo mandated that all taxpayer-funded research be made available to the public without delay upon publication, without an embargo period, superseding the 2013 OSTP public access policy. This public access policy promotes transparency and the democratization of knowledge, ensuring that the fruits of scientific endeavors funded by federal agencies could be immediately accessed and built upon by scientists, educators, students, and the public at large. To implement the requirements of the OSTP guidance and DOE Public Access Plan, the Office of Nuclear Energy (NE) has implemented public access plan guidance and has identified several areas where better data management practices would further expand public access to important nuclear energy related scientific data, reports, and other technical products. Significant NE supported efforts are already underway for data management and public access to important nuclear energy related data.1 2 To address gaps in data management practices, and improve retention and accessibility of data, NE is actively exploring enhanced data management options utilizing its high-performance computing resources administered by its Nuclear Scientific User Facility Program. A newly piloted system, the Nuclear Research Data System (NRDS) acts as a portal for data collection and dissemination. Nuclear Energy University Program Research and Development Portfolio According to Web of Science, NEUP has produced 2,345 journal publication that have been cited more than 61,000 times3 and countless conference proceedings. These publications are publicly available through OSTI.gov and in the open literature. Additional scientific and technical products including project milestones that are not publications and NEUP project final reports are vetted through OSTI.gov and released once reviewed and approved by DOE. Since 2009, NEUP has awarded close to 1,000 different R&D projects in technical areas across the NE research programs. As of June 2023, 512 NEUP reports are publicly available on OSTI. The underlying data for projects is still held at universities, and data transfer, co-location, and dissemination has not occurred in a systematic way. NEUP data is currently accessible through myriad university-based data repositories, or through direct requests to PIs. The program identified this patchwork of repositories, or often lack of publicly available data, as a significant barrier to an organized, accessible, and comprehensive solution to sharing data with the larger nuclear energy community. Approach The goal of this pilot project is to establish a pathway to a consolidated long-term repository for NEUP project data. To accomplish this goal, the pilot strives to accomplish the following objectives: Establish data collection standards, including a standard set of required supplementary information to contextualize and support raw data files. Work with the HPC group collect and upload information and to modify the NRDS system, as needed, to support a standardized approach. Resolve potential barriers to successful roll out of an expanded data collection strategy, including modifying data management plan guidelines and establishing a document and data release process that accounts for potential intellectual property and/or export control concerns. Results Overall, the pilot was successful in collecting 8,982 raw and processes data files, 220 reports, 56 calibration files, and 5,931 other supplementary documents. Supplementary documents included experimental plans, methods, journal publications and conference proceedings, milestone reports, and final reports. Figure 2 shows the number of data sets and supplementary project information provided by each project. Projects has significantly different input, depending on experimental data produced and completeness of the datasets provided.

Data collection↗

Thermodynamic analysis of turbulent combustion in a spark ignition engine. Experimental evidence

A method independent of physical modeling assumptions is presented to analyze high speed flame photography and cylinder pressure measurements from a transparent piston spark ignition research engine. The method involves defining characteristic quantities of the phenomena of flame propagation and combustion, and estimating their values from the experimental information. Using only the pressure information, the mass fraction curves are examined. An empirical burning law is presented which simulates such curves. Statistical data for the characteristics delay and burning angles which show that cycle to cycle fractional variations are of the same order of magnitude for both angles are discussed. The enflamed and burnt mass fractions are compared as are the rates of entrainment and burning.

Beretta, G. P.↗

An adaptive approach to machine learning for compact particle accelerators

Abstract Machine learning (ML) tools are able to learn relationships between the inputs and outputs of large complex systems directly from data. However, for time-varying systems, the predictive capabilities of ML tools degrade if the systems are no longer accurately represented by the data with which the ML models were trained. For complex systems, re-training is only possible if the changes are slow relative to the rate at which large numbers of new input-output training data can be non-invasively recorded. In this work, we present an approach to deep learning for time-varying systems that does not require re-training, but uses instead an adaptive feedback in the architecture of deep convolutional neural networks (CNN). The feedback is based only on available system output measurements and is applied in the encoded low-dimensional dense layers of the encoder-decoder CNNs. First, we develop an inverse model of a complex accelerator system to map output beam measurements to input beam distributions, while both the accelerator components and the unknown input beam distribution vary rapidly with time. We then demonstrate our method on experimental measurements of the input and output beam distributions of the HiRES ultra-fast electron diffraction (UED) beam line at Lawrence Berkeley National Laboratory, and showcase its ability for automatic tracking of the time varying photocathode quantum efficiency map. Our method can be successfully used to aid both physics and ML-based surrogate online models to provide non-invasive beam diagnostics.

97 MATHEMATICS AND COMPUTING↗

Evaluated Cross Sections of Photoneutron Reactions on the Isotope {sup 116}Sn and Spectra of Neutrons Originating from These Reactions

With the aid of the results obtained by evaluating cross sections of partial photoneutron reactions on the isotope {sup 116}Sn and the energy spectra of neutrons originating from these reactions, the possible reasons for the well-known discrepancies between the results of different photonuclear experiments were studied on the basis of a combinedmodel of photonuclear reactions. On the basis of physical criteria of data reliability and an experimental–theoretical method for evaluating cross sections of partial reactions, it was found that these discrepancies were due to unreliably redistributing neutrons between (γ, 1n), (γ, 2n), and (γ, 3n) reactions because of nontrivial correlations between the experimentally measured energy of neutrons and their multiplicity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms

Purpose: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. Methods: To simulate heterogeneous conditions, four materials were used: Virtual Water™ (VM), BR50/50™, cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR {sup 192}Ir source: TLD-100™, Gafchromic{sup ®} EBT3 film, and an Exradin™ A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the PENELOPE/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision™ TPS software, which includes a grid-based Boltzmann solver Acuros™. The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water™ setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros™ algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. Results: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50™ material producing results similar to the Virtual Water™ results. Our experimental methods agree with the PENELOPE/penEasy simulations for most setups and dosimeters. The TPS relative differences with the Acuros™ algorithm were similar in both experimental and simulated setups. The discrepancy between the BrachyVision™, Acuros™, and TG-43 dose responses in the phantom described by this work exceeded 12% for certain setups. Conclusions: The results derived from the phantom measurements show good agreement with the simulations and TPS calculations, using Acuros™ algorithm. Differences in the dose responses were evident in the experimental results when heterogeneous materials were introduced. These measurements prove the usefulness of the heterogeneous phantom for verification of HDR treatment planning systems based on model-based dose calculation algorithms.

07 ISOTOPE AND RADIATION SOURCES↗

Solvation structure of the halides from x-ray absorption spectroscopy

Three-dimensional models for the aqueous solvation structures of chloride, bromide, and iodide are reported. K-edge extended X-ray absorption fine structure (EXAFS) and Minuit X-ray absorption near edge (MXAN) analyses found well-defined single shell solvation spheres for bromide and iodide. However, dissolved chloride proved structurally distinct, with two solvation shells needed to explain its strikingly different X-ray absorption near edge structure (XANES) spectrum. Final solvation models were as follows: iodide, 8 water molecules at 3.60 ± 0.13 Å and bromide, 8 water molecules at 3.40 ± 0.14 Å, while chloride solvation included 7 water molecules at 3.15 ± 0.10 Å, and a second shell of 7 water molecules at 4.14 ± 0.30 Å. Each of the three derived solvation shells is approximately uniformly disposed about the halides, with no global asymmetry. Time-dependent density functional theory calculations simulating the chloride XANES spectra following from alternative solvation spheres revealed surprising sensitivity of the electronic state to 6-, 7-, or 8-coordination, implying a strongly bounded phase space for the correct structure during an MXAN fit. MXAN analysis further showed that the asymmetric solvation predicted from molecular dynamics simulations using halide polarization can play no significant part in bulk solvation. Classical molecular dynamics used to explore chloride solvation found a 7-water solvation shell at 3.12 (−0.04/+0.3) Å, supporting the experimental result. These experiments provide the first fully three-dimensional structures presenting to atomic resolution the aqueous solvation spheres of the larger halide ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An analytical study of the effect of coolant flow variables on the kinetic energy output of a cooled turbine blade flow

The results of an analytical study to determine the effect of changes in the amount, velocity, injection location, injection angle, and temperature of coolant flow on blade row performance are presented. The results show that the change in output of a cooled turbine blade row relative to the specific output of the uncooled blade row can be positive, negative, or zero. Comparisons between the analytical results and experimental results for four different cases of coolant discharge, all at a coolant temperature ratio of unity, show good agreement for three cases and rather poor agreement for the other. To further test the validity of the method, more experimental data is needed, particularly at different coolant temperature ratios.

Prust, H. W., Jr.↗

Experimental test of the ratio method for nuclear-reaction analysis

Nuclear halos are exotic quantal structures observed far from stability. They are mostly studied through reactions. The ratio of angular cross sections for breakup and scattering is predicted to be independent of the reaction process and to be very sensitive to the halo structure. We test this new observable experimentally for the first time on the collision of 11 Be on C at 22.8 MeV/nucleon and using existing data on Pb at 19.1 MeV/nucleon. The theoretical predictions are verified, which offers the possibility to develop a new spectroscopic tool to study nuclear structure far from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗