Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Emulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Implementations and Evaluations of Wind Turbine Inertial Controls With FAST and Digital Real-Time Simulations

This paper presents a novel simulation approach to evaluate new ancillary service controls in the context of large-scale wind power integration. We adopt and compare different types of turbine inertial control methods with the proposed modifications to cope with realistic wind conditions in the field. The simulation procedure is started with the software-based simulation, in which we employ the high-fidelity wind turbine simulator FAST that models a real three-bladed controls advanced research turbine (CART3). The advantages of using FAST are that it can provide convincing simulation results and address the interactions between turbine electrical and mechanical systems. The developed controller model is then rapidly prototyped for the real-time simulation with the hardware-in-the-loop scheme. CART3 will respond to a virtual frequency event triggered in the emulated electric grid modeled in a digital real-time simulator. The introduced simulation platform streamlines the procedure of designing turbine auxiliary controls, and these simulations results give insights on the turbine controls and their impacts on the interconnected power system, as well as the effects on turbine mechanical components. For example, the results indicate that the inertial controls tend to reduce the out-of-plane mechanical loadings in region 2, while such loadings are dominated by the pitch actions in region 3.

17 WIND ENERGY↗

Generic Multi-Frequency Modelling of Converter-Connected Renewable Energy Generators Considering Frequency and Sequence Couplings

Frequency and sequence couplings can compromise the trustworthiness of multi-frequency models for converter-based systems. There have been effective attempts to address the couplings mainly by linearized averaged models. Only a few studies have been conducted on practical optimization of such models with enormous matrices and experimental results. This paper provides a generic theory for coupling patterns and proposes a multi-frequency modelling method to detect and address only the main couplings in the sequence domain for converter-connected renewable energy generators. The proposed generic model is based on empirical tests using small-signal perturbations and adopting Fourier transform on the switching converter response. The proposed theory and modelling methodology are verified using a 7MVA grid emulator for voltage perturbation tests on a 2MVA photo-voltaic converter. Accordingly, the couplings can exist in more generic forms, including multiples of perturbation and fundamental frequencies. To the best of our knowledge, the patterns with the multiples of the perturbation frequency have been overlooked in the literature. Furthermore, the mirror frequency concept is valid for all coupling patterns and is included in the proposed model. Besides, the proposed patterns and the environment noise levels have been practical criteria for selecting the main couplings.

frequency and sequence couplings↗

Extension of the Generic Multi-Frequency Modelling Method for Type 3 Wind Turbines

Reflecting potential non-linearities of converter-based systems, especially frequency and sequence couplings, is an ongoing challenge for linearized multi-frequency models. Besides, design details are required to develop such models, which either are the intellectual property of manufacturers or require experimental tests. The generic multi-frequency modelling method has been proposed to fill this gap; however, it is only developed for converter-connected systems, e.g., Type 4 Wind Turbines (WT). This paper proposes to extend the application of the generic multi-frequency modelling method for Type 3 WTs. In this way, a theory for patterns of the couplings in Type 3 WTs is proposed. Accordingly, a group of emissions and couplings are Rotor-Speed-Dependent (RSD). The RSD emissions and couplings are particular characteristics of Type 3 WTs, which should be addressed in the generic multi-frequency models. Additionally, the proposed theory is verified by unique-worldwide experimental perturbation tests on a 2 MVA Type 3 WT using a 7 MVA grid emulator. Accordingly, a limited number of RSD couplings and emissions are observed in the test results, mainly in low frequencies (below 1 kHz). Therefore, addressing the RSD couplings is practical and important to extend the generic multi-frequency modelling for Type 3 WTs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Testing and Assessment of Protection Scheme Using Real-Time Hardware-in-the-Loop and IEC 61850 Standard

The main challenge of the microgrid is to design a suitable protection scheme due to the complexity of the architecture of the microgrid. The importance of the proposed protection technique is threefold. First, it presents a co-simulation platform to integrate between a simulated model on power system computer aided design (PSCAD)/real time digital simulator computer aided design (RSCAD) software’s and physical devices schweitzer engineering laboratories (SEL) 421-7 relays to protect the microgrid that includes different resources connected based on inverter interface. Second, it presents a comprehensive hardware/software setup to test the protective relays in a closed loop system and shows how to configure the protective relay’s International Electrotechnical Commission 61850 communications. Third, IEEE 1588 standard is used to provide sub nanoseconds latency between the simulated model that emulated on real time digital simulator (RTDS) and the external devices. Also, the measurement signals are synchronized between RTDS and the external devices using giga-transceiver synchronization card (GTSYNC) interface card and SEL-2488 satellite-synchronized network clock. The results showed that the co-simulation infrastructure introduces a highly dependable design, analysis, and testing environment for cyber and physical data flow in the system. Besides that, the voltages at ac/dc sides and frequency at fault condition were maintained due to the energy storage device contributions at different modes of operation.

42 ENGINEERING↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Development and Experimental Validation of a High-Power DC Distribution Testbed for Advanced Charging Infrastructure and Energy Management

This paper presents the development of a hardware testbed for DC-distributed high-power charging (HPC) stations. As DC distributed solutions emerge as a viable solution to optimize HPC site operations, challenges such as interoperability, protection, and seamless integration of distributed energy resources (DER) persist. These issues underscore the need for a robust testing facility to investigate compliance of available commercial off-the-shelf (COTS) market devices. The developed testbed features a DC-distributed charging hub including a charger, emulated energy storage system (ESS), and site level communication and controller implementation. It facilitates the testing of COTS hardware, charger prototypes, standards validation and site energy management system (SEMS) controllers at rated power. This paper details the development of the charging infrastructure platform, implementation of communication system, validation of different SEMS algorithms, and understanding improvements required for future expansion. Using the developed testbed, interoperability gaps for SEMS implementation with multi-vehicle concurrent charging via a multi-port charger are experimentally observed. Aimed at supporting the transition to large-scale EV charging infrastructure deployment and DER integration, this testbed plays a crucial role in conformity testing of COTS device interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomic Intelligent Cyber Sensor to Support Industrial Control Network Awareness

The proliferation of digital devices in a networked industrial ecosystem, along with an exponential growth in complexity and scope, has resulted in elevated security concerns and management complexity issues. This paper describes a novel architecture utilizing concepts of Autonomic computing and a SOAP based IF-MAP external communication layer to create a network security sensor. This approach simplifies integration of legacy software and supports a secure, scalable, self-managed framework. The contribution of this paper is two-fold: 1) A flexible two level communication layer based on Autonomic computing and Service Oriented Architecture is detailed and 2) Three complementary modules that dynamically reconfigure in response to a changing environment are presented. One module utilizes clustering and fuzzy logic to monitor traffic for abnormal behavior. Another module passively monitors network traffic and deploys deceptive virtual network hosts. These components of the sensor system were implemented in C++ and PERL and utilize a common internal D-Bus communication mechanism. A proof of concept prototype was deployed on a mixed-use test network showing the possible real world applicability. In testing, 45 of the 46 network attached devices were recognized and 10 of the 12 emulated devices were created with specific Operating System and port configurations. Additionally the anomaly detection algorithm achieved a 99.9% recognition rate. All output from the modules were correctly distributed using the common communication structure.

97 MATHEMATICS AND COMPUTING↗

A DDS-Based Energy Management Framework for Small Microgrid Operation and Control

The smart grid is seen as a power system with realtime communication and control capabilities between the consumer and the utility. This modern platform facilitates the optimization in energy usage based on several factors including environmental, price preferences, and system technical issues. In this paper a real-time energy management system (EMS) for microgrids or nanogrids was developed. The developed system involves an online optimization scheme to adapt its parameters based on previous, current, and forecasted future system states. The communication requirements for all EMS modules were analyzed and are all integrated over a data distribution service (DDS) Ethernet network with appropriate quality of service (QoS) profiles. In conclusion, the developed EMS was emulated with actual residential energy consumption and irradiance data from Miami, Florida and proved its effectiveness in reducing consumers’ bills and achieving flat peak load profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anticipating Optical Availability in Hybrid RF/FSO Links Using RF Beacons and Deep Learning

Radiofrequency (RF) communications offer reliable but low data rates and energy-inefficient satellite links, while free-space optical (FSO) promises high bandwidth but struggles with disturbances imposed by atmospheric effects. A hybrid RF/FSO architecture aims to achieve optimal reliability along with high data rates for space communications. Accurate prediction of dynamic ground-to-satellite FSO link availability is critical for routing decisions in low-earth orbit constellations. In this paper, we propose a system leveraging ubiquitous RF links to proactively forecast FSO link degradation prior to signal drops below threshold levels. This enables pre-calculation of rerouting to maximally maintain high data rate FSO links throughout the duration of weather effects. We implement a supervised learning model to anticipate FSO attenuation based on the analysis of RF patterns. Through the simulation of a dense lower earth orbit (LEO) satellite constellation, we demonstrate the efficacy of our approach in a simulated satellite network, highlighting the balance between predictive accuracy and prediction duration. An emulated cloud attenuation model is proposed to provide insight into the temporal profiles of RF signals and their correlation to FSO channel dynamics. Our investigation sheds light on the trade-offs between prediction horizon and accuracy arising from RF beacon numbers and proximity.

FSO availability↗

Advising Big Data Transfer Over Dedicated Connections Based on Profiling Optimization

Big data transfer in next-generation scientific applications is currently commonly carried out over dedicated channels in high-performance networks (HPNs), where transport protocols play a critical role in maximizing application-level throughput. Optimizing the performance of these protocols is challenging: i) transport protocols perform differently in various network environments, and the protocol choice is not straightforward; ii) even for a given protocol in a given environment, different parameter settings of the protocol may lead to significantly different performance and oftentimes the default setting does not yield the best performance. However, it is prohibitively time-consuming to conduct exhaustive transport profiling due to the large parameter space. In this paper, we propose a PRofiling Optimization Based DAta Transfer Advisor (ProbData) to help end users determine the most effective transport method with the most appropriate parameter settings to achieve satisfactory performance for big data transfer over dedicated connections in HPNs. ProbData employs a fast profiling scheme based on the Simultaneous Perturbation Stochastic Approximation algorithm, namely, FastProf, to accelerate the exploration of the optimal operational zones of various transport methods to improve profiling efficiency. We first present a theoretical background of the optimized profiling approach in ProbData and then detail its design and implementation. The advising procedure and performance benefits of FastProf and ProbData are illustrated and evaluated by both extensive emulations based on real-life performance measurements and experiments over various physical connections in existing production HPNs.

97 MATHEMATICS AND COMPUTING↗

Three-Dimensional Event Localization in Bulk Scintillator Crystals Using Optical Coded Apertures

Scintillator-based detectors are among the most commonly used methods for detecting ionizing radiation. Scintillators provide a reliable, cost-effective, and simple way to make large-volume detectors. Furthermore, localizing the position of the interactions in three dimensions within the crystals is useful to a wide array of fields. The most straightforward way of doing this is to pair the crystal with a position-sensitive phototransducer (PT). This allows for measurement of the shape of the light spot at the PT plane. Using this information, various methods exist to localize the gamma-ray interaction in the crystal; however, the position resolution worsens the farther the event occurs from the PT plane. To improve on the localization ability, this work uses an optical coded-aperture shadow mask between the crystal and the PT. In addition, the recorded detector response is used in reconstructing the event over the entire depth of the crystal, and the “sharpest” reconstructed image gives an event's depth. The lateral position is given from the standard coded-aperture image reconstruction. Lastly, experimental results obtained by emulating a 26-mm-thick crystal using a thin 1-mm-thick NaI(Tl) crystal and different amounts of light pipe between the crystal and the PT plane achieved ~ 1 to 2-mm resolution in all three dimensions throughout most of the 26-mm-thick crystal.

36 MATERIALS SCIENCE↗

Fast and Accurate Simulation of the Cray XMT Multithreaded Supercomputer

Irregular applications, such as data mining and analysis or graph-based computations, show unpredictable memory/network access patterns and control structures. Highly multithreaded architectures with large processor counts, like the Cray MTA-1, MTA-2 and XMT, appear to address their requirements better than commodity clusters. However, the research on highly multithreaded systems is currently limited by the lack of adequate architectural simulation infrastructures due to issues such as size of the machines, memory footprint, simulation speed, accuracy and customization. At the same time, Shared-memory MultiProcessors (SMPs) with multi-core processors have become an attractive platform to simulate large scale machines. In this paper, we introduce a cycle-level simulator of the highly multithreaded Cray XMT supercomputer. The simulator runs unmodified XMT applications. We discuss how we tackled the challenges posed by its development, detailing the techniques introduced to make the simulation as fast as possible while maintaining a high accuracy. By mapping XMT processors (ThreadStorm with 128 hardware threads) to host computing cores, the simulation speed remains constant as the number of simulated processors increases, up to the number of available host cores. The simulator supports zero-overhead switching among different accuracy levels at run-time and includes a network model that takes into account contention. On a modern 48-core SMP host, our infrastructure simulates a large set of irregular applications 500 to 2000 times slower than real time when compared to a 128-processor XMT, while remaining within 10\% of accuracy. Emulation is only from 25 to 200 times slower than real time.

Cray XMT↗

FedCSpc: A Cross-Silo Federated Learning System With Error-Bounded Lossy Parameter Compression

Cross-Silo federated learning is widely used for scaling deep neural network (DNN) training over data silos from different locations worldwide while guaranteeing data privacy. Communication has been identified as the main bottleneck when training large-scale models due to large-volume model parameters and gradient transmission across public networks with limited bandwidth. Most previous works focus on gradient compression, while limited work tries to compress parameters that can not be ignored and extremely affect communication performance during the training. Here, to bridge this gap, we propose FedCSpc: an efficient cross-silo federated learning system with an XAI-driven adaptive parameter compression strategy for large-scale model training. Our work substantially differs from existing gradient compression techniques due to the distinct data features of gradient and parameter. The key contributions of this paper are fourfold. (1) Our designed FedCSpc proposes to compress the parameter during the training using the state-of-the-art error-bounded lossy compressor – SZ3. (2) We develop an adaptive compression error bound adjustment algorithm to guarantee the model accuracy effectively. (3) We exploit an efficient approach to utilize the idle CPU resources of clients to compress the parameters. (4) We perform a comprehensive evaluation with a wide range of models and benchmarks on a GPU cluster with 65 GPUs. Results show that FedCSpc can achieve the same model accuracy as FedAvg while reducing the data volume of parameters and gradients in communication by up to 7.39× and 288×, respectively. With 32 clients on a 4 Gb size model, FedCSpc significantly outperforms FedAvg in wall-clock time in the emulated WAN environment (at the bandwidth of 1 Gbps or lower without loss of generality).

SZ3↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthesizing Virtual Oscillators to Control Islanded Inverters

Virtual oscillator control (VOC) is a decentralized control strategy for islanded microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. Compared to droop control, which is only well defined in sinusoidal steady state, VOC is a time-domain controller that enables interconnected inverters to stabilize arbitrary initial conditions to a synchronized sinusoidal limit cycle. However, the nonlinear oscillators that are elemental to VOC cannot be designed with conventional linear-control design methods. We address this challenge by applying averaging- and perturbation-based nonlinear analysis methods to extract the sinusoidal steady-state and harmonic behavior of such oscillators. The averaged models reveal conclusive links between real- and reactive-power outputs and the terminal-voltage dynamics. Similarly, the perturbation methods aid in quantifying higher order harmonics. The resultant models are then leveraged to formulate a design procedure for VOC such that the inverter satisfies standard ac performance specifications related to voltage regulation, frequency regulation, dynamic response, and harmonic content. Experimental results for a single-phase 750 VA, 120 V laboratory prototype demonstrate the validity of the design approach. They also demonstrate that droop laws are, in fact, embedded within the equilibria of the nonlinear-oscillator dynamics. This establishes the backward compatibility of VOC in that, while acting on time-domain waveforms, it subsumes droop control in sinusoidal steady state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development, Demonstration, and Control of a Testbed for Multiterminal HVDC System

This paper presents the development of a scaled four-terminal high-voltage direct current (HVDC) testbed, including hardware structure, communication architecture, and different control schemes. The developed testbed is capable of emulating typical operation scenarios including system start-up, power variation, line contingency, and converter station failure. Some unique scenarios are also developed and demonstrated, such as online control mode transition and station re-commission. In particular, a dc line current control is proposed, through the regulation of a converter station at one terminal. By controlling a dc line current to zero, the transmission line can be opened by using relatively low-cost HVDC disconnects with low current interrupting capability, instead of the more expensive dc circuit breaker. Utilizing the dc line current control, an automatic line current limiting scheme is developed. As a result, when a dc line is overloaded, the line current control will be automatically activated to regulate current within the allowable maximum value.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Steady-State Modeling of Modular Multilevel Converter Under Unbalanced Grid Conditions

This paper presents a steady-state model of MMC for the second-order phase voltage ripple prediction under unbalanced conditions, taking the impact of negative-sequence current control into account. From the steady-state model, a circular relationship is found among current and voltage quantities, which can be used to evaluate the magnitudes and initial phase angles of different circulating current components. Moreover, in order to calculate the circulating current in a point-to-point MMC-based HVdc system under unbalanced grid conditions, the derivation of equivalent dc impedance of an MMC is discussed as well. According to the dc impedance model, an MMC inverter can be represented as a series connected R-L-C branch, with its equivalent resistance and capacitance directly related to the circulating current control parameters. Experimental results from a scaled-down three-phase MMC system under an emulated single-line-to-ground fault are provided to support the theoretical analysis and derived model. In conclusion, this new models provides an insight into the impact of different control schemes on the fault characteristics and improves the understanding of the operation of MMC under unbalanced conditions.

30 DIRECT ENERGY CONVERSION↗