At least 1,441 records · Page 80

Plasma kinetics in a nanosecond pulsed filamentary discharge sustained in Ar–H 2 O and H 2 O

The plasma kinetics of Ar–H 2 O and H 2 O at atmospheric pressure are of interest for applications in biotechnology where rare-gas plasma jets treat liquid surfaces and in water treatment where discharges are generated in bubbles or directly in liquid water. Due to evaporation resulting from heat transfer to the liquid, for many conditions the mole fraction of water in the plasma can be large—approaching nearly pure water. In this paper, results are discussed from a combined experimental and computational investigation of the chemical kinetics in a high electron density plasma filament sustained in Ar–H 2 O at atmospheric pressure. The chemical kinetics were simulated using a 0D global model, validated by measurements of the absolute OH and H densities by laser induced fluorescence (LIF) and two-photon absorption LIF. The primary sources of H and OH during the discharge pulse are dissociative excitation transfer from metastable Ar atoms and Ar dimer excimers at low water concentration and electron impact dissociation of H 2 O at high water concentration. In spite of their similar sources, the density of OH was measured to be two orders of magnitude smaller than that of H at power densities on the order of 10 5 Jm -3 . This disparity is due to electron impact dissociation of OH during the discharge pulse and rapid reactions of OH in the presence of high H and O densities in the afterglow. It is often assumed that OH is the dominant non-selective reactive species in water-containing plasmas. These results reinforce the importance of atomic species such as H and O in water containing high energy density plasmas. A numerical parametric study revealed that the lowest energy cost for H 2 O 2 production is achieved at low energy densities in pure water. Finally, the high concentration of atomic radicals, which rapidly recombine, results in an overall lower energy efficiency of reactive species production. In particular, the selectivity of H 2 O 2 production decreases with increasing power density which instead favors H 2 and O 2 production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HUNDRED THOUSAND DEGREE GAS IN THE VIRGO CLUSTER OF GALAXIES

The physical relationship between low-excitation gas filaments at {approx}10{sup 4} K, seen in optical line emission, and diffuse X-ray emitting coronal gas at {approx}10{sup 7} K in the centers of many galaxy clusters is not understood. It is unclear whether the {approx}10{sup 4} K filaments have cooled and condensed from the ambient hot ({approx}10{sup 7} K) medium or have some other origin such as the infall of cold gas in a merger, or the disturbance of an internal cool reservoir of gas by nuclear activity. Observations of gas at intermediate temperatures ({approx}10{sup 5}-10{sup 6} K) can potentially reveal whether the central massive galaxies are gaining cool gas through condensation or losing it through conductive evaporation and hence identify plausible scenarios for transport processes in galaxy cluster gas. Here we present spectroscopic detection of {approx}10{sup 5} K gas spatially associated with the H{alpha} filaments in a central cluster galaxy, M87, in the Virgo Cluster. The measured emission-line fluxes from triply ionized carbon (C IV 1549 A) and singly ionized helium (He II 1640 A) are consistent with a model in which thermal conduction determines the interaction between hot and cold phases.

79 ASTRONOMY AND ASTROPHYSICS↗

Heating events in the nascent solar system recorded by rare earth element isotopic fractionation in refractory inclusions

Equilibrium condensation of solar gas is often invoked to explain the abundance of refractory elements in planets and meteorites. This is partly motivated, by the observation that the depletions in both the least and most refractory rare earth elements (REEs) in meteoritic group II calcium-aluminum–rich inclusions (CAIs) can be reproduced by thermodynamic models of solar nebula condensation. We measured the isotopic compositions of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb in eight CAIs to test this scenario. Contrary to expectation for equilibrium condensation, we find light isotope enrichment for the most refractory REEs and more subdued isotopic variations for the least refractory REEs. This suggests that group II CAIs formed by a two-stage process involving fast evaporation of preexisting materials, followed by near-equilibrium recondensation. The calculated time scales are consistent with heating in events akin to FU Orionis– or EX Lupi–type outbursts of eruptive pre–main-sequence stars.

58 GEOSCIENCES↗

Thermal chains and entrainment in cumulus updrafts, Part 2: Analysis of idealized simulations

Research has suggested that the structure of deep convection often consists of a series of rising thermals, or “thermal chain”, which contrasts with existing conceptual models that are used to construct cumulus parameterizations. In this work, simplified theoretical expressions for updraft properties obtained in Part 1 of this study are used to develop a hypothesis explaining why this structure occurs. In this hypothesis, cumulus updraft structure is strongly influenced by organized entrainment below the updraft’s vertical velocity maximum. In a dry environment, this enhanced entrainment can locally reduce condensation rates and increase evaporation, thus eroding buoyancy. For moderate-to-large initial cloud radius R, this breaks up the updraft into a succession of discrete pulses of rising motion (i.e., a thermal chain). For small R, this leads to the structure of a single, isolated rising thermal. In contrast, moist environments are hypothesized to favor plume-like updrafts for moderate-to-large R. In a series of axisymmetric numerical cloud simulations, R and environmental relative humidity (RH) are systematically varied to test this hypothesis. Vertical profiles of fractional entrainment rate, passive tracer concentration, buoyancy, and vertical velocity from these runs agree well with vertical profiles calculated from the theoretical expressions in Part 1. Analysis of the simulations supports the hypothesized dependency of updraft structure on R and RH, that is, whether it consists of an isolated thermal, a thermal chain, or a plume, and the role of organized entrainment in driving this dependency. Additional 3-dimensional (3-D) turbulent cloud simulations are analyzed, and the behavior of these 3-D runs is qualitatively consistent with the theoretical expressions and axisymmetric simulations.

54 ENVIRONMENTAL SCIENCES↗

From Deposition to Encapsulation: Roll-to-roll manufacturing of organic light emitting devices for lighting (Final Report)

Organic light emitting devices (OLEDs) are promising solid state light sources due to their high efficiency, high color quality and flexible form factors. The key to enable low cost OLED lighting, is to rapidly fabricate thin film organic layers on a continuous flexible roll, called R2R processing. This project aims to investigate the feasibility of mass production of OLED lighting using the R2R process, from deposition to encapsulation. A high efficiency white OLED is fabricated on 10 cm-wide substrate rolls in a pilot R2R tool comprising of two different organic deposition: vacuum thermal evaporation (VTE) and organic vapor phase deposition (OVPD). A high quality encapsulation process to package OLEDs is demonstrated using an atomic layer deposition tool integrated to the R2R system without air exposure. The method to achieve ultrahigh deposition rates required by R2R processing is demonstrated by OVPD. Uniform organic semiconductor thin films grown by OVPD at rates as high as 50 Å/s are achieved. A comprehensive numerical model that is capable of simulating complex, multilayer WOLED structures is developed to provide an alternative to experimental iterations of OLED design and tests. A cost estimate on the R2R production of WOLEDs for lighting is developed. Assuming a WOLED luminance of 10 klm/m 2 , the cost of a WOLED light engine is anticipated to be $\$ 12.5$ /klm. With incremental reduction in material and driver costs and improved luminance, the cost of WOLED lighting can be reduced to $\$ 6.3$ /klm in the near term. These findings suggest OLED lighting can be volume manufactured by R2R vapor deposition methods with much reduced costs compared to current batch processing methods, potentially positioning WOLEDs for use in numerous premium lighting applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of phase state and non-ideal mixing on equilibration timescales of secondary organic aerosol partitioning

Abstract. Evidence has accumulated that secondary organic aerosols (SOAs) exhibit complex morphologies with multiple phases that can adopt amorphous semisolid or glassy phase states. However, experimental analysis and numerical modeling on the formation and evolution of SOA still often employ equilibrium partitioning with an ideal mixing assumption in the particle phase. Here we apply the kinetic multilayer model of gas–particle partitioning (KM-GAP) to simulate condensation of semi-volatile species into a core–shell phase-separated particle to evaluate equilibration timescales of SOA partitioning. By varying bulk diffusivity and the activity coefficient of the condensing species in the shell, we probe the complex interplay of mass transfer kinetics and the thermodynamics of partitioning. We found that the interplay of non-ideality and phase state can impact SOA partitioning kinetics significantly. The effect of non-ideality on SOA partitioning is slight for liquid particles but becomes prominent in semisolid or solid particles. If the condensing species is miscible with a low activity coefficient in the viscous shell phase, the particle can reach equilibrium with the gas phase long before the dissolution of concentration gradients in the particle bulk. For the condensation of immiscible species with a high activity coefficient in the semisolid shell, the mass concentration in the shell may become higher or overshoot its equilibrium concentration due to slow bulk diffusion through the viscous shell for excess mass to be transferred to the core phase. Equilibration timescales are shorter for the condensation of lower-volatility species into semisolid shell; as the volatility increases, re-evaporation becomes significant as desorption is faster for volatile species than bulk diffusion in a semisolid matrix, leading to an increase in equilibration timescale. We also show that the equilibration timescale is longer in an open system relative to a closed system especially for partitioning of miscible species; hence, caution should be exercised when interpreting and extrapolating closed-system chamber experimental results to atmosphere conditions. Our results provide a possible explanation for discrepancies between experimental observations of fast particle–particle mixing and predictions of long mixing timescales in viscous particles and provide useful insights into description and treatment of SOA in aerosol models.

54 ENVIRONMENTAL SCIENCES↗

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES↗

Evaluation Of A Turbidity Meter For Use At The Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a Turbidity Meter for Use at the Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A “go/no-go” decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a “go” decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a “no-go” determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the issuance of the initial version of this report but under the scope of the original request for technical assistance, WSE asked for this report to be revised to include the “go/no-go” CU value corresponding to 0.28 wt% solids. It was this request that led to the preparation of Revision 1 of the report. The results for the 0.28 wt% solids value were developed following the same approach as that utilized for the 0.14 wt% solids value. A sludge simulant was used to develop standards for testing both Optek units and to determine the viability of a “go/no-go” CU response for each of the units. Statistical methods were used by SRNL to develop the critical CU value for the “go/no-go” decision for these standards for each Optek unit. Since only one sludge simulant was available for this testing, the sensitivity of these results to other simulants and to actual sludge material is not known. However, limited testing with samples from the actual DWPF process (both SRAT product samples and SMECT samples) demonstrated that the use of the “go/no-go” criteria developed from the sludge simulant testing was conservative for these samples taken from the sludge batch, Sludge Batch 7b, being processed at the time of this testing. While both of the Optek units performed very reliably during this testing, there were statistically significant differences (although small on a practical scale) between the two units. Thus, testing should be conducted on any new unit of this Optek model to qualify it before it is used to support the DWPF operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Event-by-Event Evaluation of the Prompt Fission Neutron Spectrum From 239 Pu(n,f)

We have developed an improved evaluation method for the spectrum of neutrons emitted in fission of 239 Pu induced by incident neutrons with energies up to 20 MeV. The <v> covariance data, including incident energy correlations introduced by the <v> evaluation method, were used to fix the input parameters in our event-by-event model of fission, FREYA, by applying formal statistical methods. Formal estimates of uncertainties in the evaluation were developed by randomly sampling model inputs and calculating likelihood functions based on agreement with the evaluated <v>. Our approach is able to employ a greater variety of fission measurements than the relatively coarse spectral data alone. It also allows the study of numerous fission observables for more accurate model validation. The combination of an event-by-event Monte Carlo fission model with a statistical-likelihood analysis is thus a powerful tool for evaluation of fission-neutron data. Our empirical model FREYA follows the complete fission event from birth of the excited fragments through their decay via neutron emission until the fragment excitation energy is below the neutron separation energy when neutron emission can no longer occur. The most recent version of FREYA incorporates pre-equilibrium neutron emission, the emission of the first neutron before equilibrium is reached in the compound nucleus, and multi-chance fission, neutron evaporation prior to fission when the incident neutron energy is above the neutron separation energy. Energy, momentum, charge and mass number are conserved throughout the fission process. The best available values of fragment masses and total kinetic energies are used as inputs to FREYA. We fit three parameters that are not well under control from previous measurements: the shift in the total fragment kinetic energy; the energy scale of the asymptotic level density parameter, controlling the fragment 'temperature' for neutron evaporation; and the relative excitation of the light and heavy fragments, governing the number and energy of neutrons emitted from each fragment. The latter two parameters are assumed to be independent of the incident neutron energy while the first varies with incident energy. We describe our method and the subsequent spectral evaluation and present the results of several standard validation calculations that test our new evaluation. These benchmarks include critical assemblies, sensitive to criticality in fast systems; pulsed sphere measurements testing the spectra at incident neutron energies of 14 MeV; and other tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

An Investigation of Hydrometeor Latent Cooling upon Convective Cold Pool Formation, Sustainment, and Properties

Downdrafts extending from convective clouds can produce cold pools that propagate outward, sometimes initiating new convection along their leading edges. Models operating at scales requiring convective parameterizations usually lack representation of this detail, and thus fail to predict this convective regeneration and longer episodes of convective activity. Developing such parameterizations requires an improved understanding of the physical drivers of cold pools, and detailed studies of the roles of all the contributing microphysical processes have been lacking. This study utilizes a set of 12 simulations conducted within a single convective environment, but with variability in the microphysical fields produced by varying parameters influencing warm-rain or ice processes. Time-integrated microphysical budgets quantify the contribution of each hydrometeor type to the total latent cooling occurring in the downdrafts that form and sustain the cold pool. The timing of the onset of the cold pool is earlier in cases with a stronger warm rain process, but both graupel and rain were equally as likely to be the dominant hydrometeor in the downdraft first forming the cold pool. Graupel sublimation is the dominant term in sustaining the cold pool in all simulations, but the evaporation of rain has the strongest correlation to the cold pool expansion rate, depth, and intensity. Reconciling the current results with past studies elucidates the importance of considering: graupel sublimation, the latent cooling only in downdrafts contributing to the cold pool, and latent cooling in those downdrafts at altitudes that may be significantly higher than the melting level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects on precipitation, clouds, and temperature from long‐range transport of idealized aerosol plumes in WRF‐Chem simulations

Using the Weather Research and Forecasting model with Chemistry (WRF-Chem), we explored the impacts of nonlocal aerosol plumes transported at three different altitudes on a summertime convective system developed in a clean environment over the northeastern United States. Idealized aerosol plumes from forest fire and volcano emissions, which are known to be frequently transported in this region, were prescribed at three separate altitudes on the upstream boundary of WRF-Chem. The low-altitude (1.5–2.5 km) plume characteristic of forest fire emissions intersects the water clouds, resulting in optically thicker clouds and about a 30% decrease in accumulated precipitation. The precipitation response to the idealized aerosol plume is attributed to the aerosol “second indirect effect” and aerosol-induced enhancement in evaporation efficiency. Convection also significantly impacted this low-altitude aerosol plume because wet removal scavenges up to 70% of plume aerosols over regions where deep convection and precipitation occur. In stark contrast, midaltitude (5.6–6.6 km) and high-altitude (11.5–12.5 km) plumes exerted a negligible effect on clouds and precipitation. The apparent highly nonlinear sensitivity of simulated convection to the vertical positioning of nonlocal aerosol plumes is explained in terms of the dominant controls influencing this convection regime and limitations in the microphysics currently implemented in WRF-Chem.

54 ENVIRONMENTAL SCIENCES↗

Tunable internal quantum well alignment in rationally designed oligomer-based perovskite films deposited by resonant infrared matrix-assisted pulsed laser evaporation

Hybrid perovskites incorporating conjugated organic cations enable unusual charge carrier interactions among organic and inorganic structural components, but are difficult to prepare as films due to disparate component chemical/physical characteristics (e.g., solubility, thermal stability). In this work, we demonstrate that resonant infrared matrix-assisted pulsed laser evaporation (RIR-MAPLE) mitigates these challenges, enabling facile deposition of lead-halide-based perovskite films incorporating variable-length oligothiophene cations. Density functional theory (DFT) predicts suitable organic and inorganic moieties that form quantum-well-like structures with targeted luminescence or exciton separation/quenching. RIR-MAPLE-deposited films enable confirmation of these predictions by optical measurements, which further display excited state behavior transcending traditional quantum-well models—i.e., with appropriate selection of specially synthesized organic/inorganic moieties, intercomponent carrier transfer efficiently converts excitons from singlet to triplet states in organics for which intersystem crossing cannot ordinarily compete with recombination. These observations demonstrate the uniquely versatile excited-state behavior in hybrid perovskite quantum wells, and the value of integrating DFT, organic synthesis, RIR-MAPLE and spectroscopy for screening/preparing rationally devised complex structures.

36 MATERIALS SCIENCE↗

Aerosol Chemical Speciation Monitor (ACSM) Composition-Dependent Collection Efficiency (CDCE) Value-Added Product Report

Aerosol particles influence the Earth’s radiation balance directly by absorbing and scattering light and indirectly by influencing cloud formation, properties, and lifetimes. Measurements of aerosol particle optical properties, mass loading, size distributions, microphysical properties, cloud formation properties, and chemical composition are important for understanding the aerosol life cycle and for validating earth system models that predict these quantities. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Aerosol Observing System (AOS) is a highly instrumented platform that measures many of these aerosol properties in situ. The Aerodyne aerosol chemical speciation monitor (ACSM) is a baseline instrument deployed in the AOS. The ACSM provides a quantitative measurement of aerosol particle chemical composition for non-refractory (operationally defined as components that evaporate on the 600ºC vaporizer) aerosol components in real time. Standard output is the mass concentration of particulate organics, nitrate, sulfate, chloride, and ammonium. One well-known limitation to the accuracy of the ACSM data is in evaluating the fraction of the ambient aerosol particles that are detected by the instrument. This quantity is referred to as the collection efficiency (CE) and is often less than unity. This is attributed to particles rebounding after impaction onto the heated vaporizer rather than being trapped, volatilized rapidly, and detected. Other factors, such as divergence of the aerosol particle beam, may also impact CE, but the particle rebound effect is the dominant factor. Scientists will sometimes assume CE = 0.5 (i.e., one half of sampled particles are detected) for ambient particles collected during field missions. However, parameterizations have been developed that express CE as a function of the measured chemical composition, referred to as the composition-dependent collection efficiency (CDCE). The physical explanation for a CDCE, supported by laboratory studies, is that rebound from the vaporizer is a function of the particle phase, with liquid-like particles “sticking” to the vaporizer and solid-like or crystalline particles “bouncing” from the vaporizer. Thus, particles with compositions are liquids-like under the measurement conditions (e.g., certain organics, acidic particles, particles enriched in nitrate) have CE close to unity while crystalline or solid particles (e.g., deliquesced ammonium sulfate) have lower CE. This value-added product (VAP) implements the procedure described by Middlebrook et al. (2012) to correct the ACSM data for the composition-dependent collection efficiency. Applying this parameterization improves the accuracy of the ACSM data and brings them into better agreement with other co-located aerosol measurements.

54 ENVIRONMENTAL SCIENCES↗

Task 1 Steam Oxidation (NETL-US)

Some conclusions are: (1) Increased flow rates can lower chromia activity in alloys with Ti and Mn - (a) Reduced chromia activity reduces equilibrium CrO{sub 2}(OH){sub 2}(g) vapor pressures; (2) Model is very sensitive to small decreases in chromia activity at the HP turbine - (a) Upstream partial saturation of the gas phase with CrO{sub 2}(OH){sub 2}(g) can become nearly or fully saturated at the HP turbine, (b) Can radically change breakaway oxidation times from less than a year to never happening; and (3) Thus even small chromia activity reductions from Ti and Mn additions can make evaporation issues self-correcting.

36 MATERIALS SCIENCE↗

Projected Changes in Daily Variability and Seasonal Cycle of Near-Surface Air Temperature over the Globe during the Twenty-First Century

Abstract Increases in atmospheric greenhouse gases will not only raise Earth’s temperature but may also change its variability and seasonal cycle. Here CMIP5 model data are analyzed to quantify these changes in surface air temperature (Tas) and investigate the underlying processes. The models capture well the mean Tas seasonal cycle and variability and their changes in reanalysis, which shows decreasing Tas seasonal amplitudes and variability over the Arctic and Southern Ocean from 1979 to 2017. Daily Tas variability and seasonal amplitude are projected to decrease in the twenty-first century at high latitudes (except for boreal summer when Tas variability increases) but increase at low latitudes. The day of the maximum or minimum Tas shows large delays over high-latitude oceans, while it changes little at low latitudes. These Tas changes at high latitudes are linked to the polar amplification of warming and sea ice loss, which cause larger warming in winter than summer due to extra heating from the ocean during the cold season. Reduced sea ice cover also decreases its ability to cause Tas variations, contributing to the decreased Tas variability at high latitudes. Over low–midlatitude oceans, larger increases in surface evaporation in winter than summer (due to strong winter winds, strengthened winter winds in the Southern Hemisphere, and increased winter surface humidity gradients over the Northern Hemisphere low latitudes), coupled with strong ocean mixing in winter, lead to smaller surface warming in winter than summer and thus increased seasonal amplitudes there. These changes result in narrower (wider) Tas distributions over the high (low) latitudes, which may have important implications for other related fields.

54 ENVIRONMENTAL SCIENCES↗