Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Validation of full-wave simulations for mode conversion of waves in the ion cyclotron range of frequencies with phase contrast imaging in Alcator C-Mod

Mode conversion of fast waves in the ion cyclotron range of frequencies (ICRF) is known to result in current drive and flow drive under optimised conditions, which may be utilized to control plasma profiles and improve fusion plasma performance. To describe these processes accurately in a realistic toroidal geometry, numerical simulations are essential. Quantitative comparison of these simulations and the actual experimental measurements is important to validate their predictions and to evaluate their limitations. The phase contrast imaging (PCI) diagnostic has been used to directly detect the ICRF waves in the Alcator C-Mod tokamak. The measurements have been compared with full-wave simulations through a synthetic diagnostic technique. Recently, the frequency response of the PCI detector array on Alcator C-Mod was recalibrated, which greatly improved the comparison between the measurements and the simulations. In this study, mode converted waves for D-{sup 3}He and D-H plasmas with various ion species compositions were re-analyzed with the new calibration. For the minority heating cases, self-consistent electric fields and a minority ion distribution function were simulated by iterating a full-wave code and a Fokker-Planck code. The simulated mode converted wave intensity was in quite reasonable agreement with the measurements close to the antenna, but discrepancies remain for comparison at larger distances.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance study of polycrystalline CVD diamond detectors for fast neutron monitoring

Diamond detectors using polycrystalline CVD diamond substrates of thickness 300μm and 100μm were fabricated for fast neutron monitoring application.. The characterization of detectors was carried out using various tests such as leakage current, capacitance and alpha particle response. The performance of detectors was evaluated for fast neutrons at different neutron yields. The results presented in this work demonstrate that the diamond detectors will be suitable for monitoring fast neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced far infrared blocked impurity band detectors based on germanium liquid phase epitaxy

This research has shown that epilayers with residual impurity concentrations of 5 x 10(sup 13) cm(exp -3) can be grown by producing the purest Pb available in the world. These epilayers have extremely low minority acceptor concentrations, which is ideal for fabrication of IR absorbing layers. The Pb LPE growth of Ge also has the advantageous property of gettering Cu from the epilayer and the substrate. Epilayers have been grown with intentional Sb doping for IR absorption on lightly doped substrates. This research has proven that properly working Ge BIB detectors can be fabricated from the liquid phase as long as pure enough solvents are available. The detectors have responded at reach minimum wavenumbers. Optimization of the Sb doping concentration should further decrease the photoionization energy of these detectors. Ge BIB detectors have been fabricated that respond to 60 cm(exp -1) with low responsivity. Through reduction of the minority residual impurities, detector performance has reached responsivities of 1 A/W. These detectors have exhibited quantum efficiency and NEP values that rival conventional photoconductors and are expected to provide a much more sensitive tool for new scientific discoveries in a number of fields, including solid state studies, astronomy, and cosmology.

Olsen, C. S.↗

Optimizing Transition-Edge Sensor Design for High Count-Rate Applications

We are developing transition-edge sensor (TES) X-ray detectors optimized for high count-rate applications. These devices are fabricated on thick (300 {mu}m) Si substrates, resulting in a 20 times increase in thermal conductance to the heat sink compared to our conventional membrane isolated TES's. Operating a TES with higher heat sink conductance requires 4.5 times more bias current. This results in a 2.7 times increase in {beta}, the logarithmic derivative of resistance with respect to current. Noise measurements show a lower limit on the TES excess noise scales as (2{beta}){sup 1/2}, consistent with the near-equilibrium, non-linear expansion of the Ohmic Johnson noise. This is consistent with our membrane devices though the increased {beta} means the theoretical best attainable resolution is degraded by 25-35%. We have tested devices with different contact geometries between the absorber, and the TES and substrate. This allows us to investigate the loss of athermal phonons to the substrate, which can degrade the resolution. Results show a correlation between the stem contact area and a low-energy tail in the spectral response at 5.9 keV due to the athermal phonon loss. In several devices tested we demonstrate a resolution of 4.1-5.6 eV, coupled with detector time constants as fast as 44 {mu}s, representing an increase in detector response by 7 times compared to the membrane devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of AC-coupled low gain avalanche detectors to ionizing and non-ionizing radiation damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Directional response of several geometries for reactor-neutrino detectors

Here we have modeled six abstracted detector designs, with the goal of determining their ability to resolve the direction to an antineutrino source, including two for which we have operational data for validating our computer modeling and analytical processes. We have found that the most promising options, regardless of scale and range, have angular resolutions on the order of a few degrees, which is better than any yet achieved in practice by a factor of at least two. We examine and compare several approaches to detector geometry for their ability not only to detect the inverse beta decay (IBD) reaction, but also to determine the source direction of incident antineutrinos. The information from these detectors provides insight into reactor power and burning profile, which is especially useful in constraining the clandestine production of weapons material. In a live deployment, a nonproliferation detector must be able to isolate the subject reactor, possibly from a field of much-larger power reactors; directional sensitivity can help greatly with this task. We also discuss implications for using such detectors in longer-distance observation of reactors, from a few kilometers to hundreds of kilometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Response of Microchannel Plate and Channel Electron Multiplier Detectors to Penetrating Radiation in Space

Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area of multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Neutrino Oscillation Physics with the Daya Bay and DUNE Experiments

The team supported by this grant made significant contributions to the final results of the Daya Bay Reactor Antineutrino Experiment. This experiment utilized eight identically designed antineutrino detectors positioned at varying distances from six 2.9 GW th nuclear reactors to precisely measure the oscillation parameters that govern antineutrino disappearance at short (<2 km) baselines. Our group played a leading role in the calibration and data quality efforts, both of which have been crucial for all final results. Additionally, we co-led the development of an independent measurement of the neutrino mixing angle θ 13 and the atmospheric mass splitting using a sample of antineutrinos identified via neutron capture on hydrogen. Lastly, we laid the groundwork for a search for seasonal modulation in Daya Bay’s measured muon flux using the final dataset, a result expected to be published soon. Simultaneously, our team ramped up its participation in the Deep Underground Neutrino Experiment (DUNE). This experiment will employ a powerful neutrino beam from Fermilab in Illinois directed to the Homestake mine in South Dakota to address some of the most pressing questions in neutrino physics, including the ordering of neutrino masses and whether neutrinos violate the CP symmetry. Our work focused on the development of the pixelated and modularized Liquid Argon Time-Projection Chamber technology that is being prepared for DUNE’s Near Detector. Our group took responsibility for the development, testing, and maintenance of the firmware for the control boards of the detector’s charge readout system and played an active role in analyzing data produced by the very first fully integrated prototypes.

2x2 Demonstrator↗

Response of AC-coupled Low Gain Avalanche Detectors to Ionizing and Non-ionizing Radiation Damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

FOS: Physical sciences↗

BATSE Observations of Gamma-Ray Burst Spectra: Low-Energy Behavior of Time-Averaged Spectra - Part 3

We analyze time-averaged spectra from 86 bright gamma-ray bursts from the first 5 years of the Burst And Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory to determine whether the lowest energy data are consistent with a standard spectra form fit to the data at all energies. The BATSE Spectroscopy Detectors have the capability to observe photons as low as 5 keV. Using the gamma-ray burst locations obtained with the BATSE Large Area Detectors, the Spectroscopy Detectors' low-energy response can be modeled accurately. This, together with a postlaunch calibration of the lowest energy Spectroscopy Detector discriminator channel, which can lie in the range 5-20 keV, allows spectral deconvolution over a broad energy range, approx. 5 keV to 2 MeV. The additional coverage allows us to search for evidence of excess emission, or for a deficit, below 20 keV. While no burst has a significant (greater than or equal to 3 sigma) deficit relative to a standard spectra model, we find that 12 bursts have excess low-energy emission, ranging between 1.2 and 5.8 times the model flux, that exceeds 5 sigma in significance. This is evidence for an additional low-energy spectral component in at least some bursts, or for deviations from the power-law spectral form typically used to model gamma-ray bursts at energies below 100 keV.

Preece, R. D.↗

High efficiency proportional neutron detector with solid liner internal structures

A tube-style neutron detector, a panel-style neutron detector incorporating a plurality of tube-style neutron detectors, and a panel-style neutron detector including a plurality of anode wires are provided. A plurality of channels is provided in a neutron detector such that each channel has an inner surface of a coating layer including a neutron-absorbing material. A wire anode is provided at end of each channel so that electrons generated by a charged daughter particle generated by a neutron are collected to detect a neutron-matter interaction. Moderator units can be incorporated into a neutron detector to provide improved detection efficiencies and/or to determine neutron energy spectrum. Gas-based proportional response from the neutron detectors can be employed for special nuclear material (SNM) detection. This neutron detector can provide similar performance to .sup.3He-based detectors without requiring .sup.3He and without containing toxic, flammable, or high-pressure materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Microphotonic Focal Plane Array (TM-FPA).

The advent of high quality factor (Q) microphotonic-resonators has led to the demonstration of high-fidelity optical sensors of many physical phenomena (e.g. mechanical, chemical, and biological sensing) often with far better sensitivity than traditional techniques. Microphotonic-resonators also offer potential advantages as uncooled thermal detectors including significantly better noise performance, smaller pixel size, and faster response times than current thermal detectors. In particular, microphotonic thermal detectors do not suffer from Johnson noise in the sensor, offer far greater responsivity, and greater thermal isolation as they do not require metallic leads to the sensing element. Such advantages make the prospect of a microphotonic thermal imager highly attractive. Here, we introduce the microphotonic thermal detection technique, present the theoretical basis for the approach, discuss our progress on the development of this technology and consider future directions for thermal microphotonic imaging. Already we have demonstrated viability of device fabrication with the successful demonstration of a 20{micro}m pixel, and a scalable readout technique. Further, to date, we have achieved internal noise performance (NEP{sub Internal} < 1pW/{radical}Hz) in a 20{micro}m pixel thereby exceeding the noise performance of the best microbolometers while simultaneously demonstrating a thermal time constant ({tau} = 2ms) that is five times faster. In all, this results in an internal detectivity of D*{sub internal} = 2 x 10{sup 9}cm {center_dot} {radical}Hz/W, while roughly a factor of four better than the best uncooled commercial microbolometers, future demonstrations should enable another order of magnitude in sensitivity. While much work remains to achieve the level of maturity required for a deployable technology, already, microphotonic thermal detection has demonstrated considerable potential.

47 OTHER INSTRUMENTATION↗

Systems and methods for data storage and retrieval

A method includes directing a probe beam to a target that includes an array of data portions in a data storage medium arranged so that a beam area of the probe beam extends across a plurality of adjacent data portions, the array including a data portion subset with each data portion of the subset responsive to the probe beam to produce a response illumination, receiving the response illumination at a detector, and determining data values corresponding to the plurality of adjacent data portions based on the received response illumination. Apparatus and systems are also disclosed.

Gotthold, David W.↗

Systems and methods for data storage and retrieval

A method includes directing a probe beam to a target that includes an array of data portions in a data storage medium arranged so that a beam area of the probe beam extends across a plurality of adjacent data portions, the array including a data portion subset with each data portion of the subset responsive to the probe beam to produce a response illumination, receiving the response illumination at a detector, and determining data values corresponding to the plurality of adjacent data portions based on the received response illumination. Apparatus and systems are also disclosed.

97 MATHEMATICS AND COMPUTING↗