Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Solution growth of a deuterated trans -stilbene crystal for fast neutron detection

The paper reports results on growth and characterization of the first deuterated analog of the trans -stilbene crystal. The high optical quality stilbene-d12 single crystal was grown by application of the solution technique using specially synthesized raw material and an aromatic solvent (anisole). Optical, physical, and scintillation properties of the new material are compared to those of the regular trans -stilbene crystal. In conclusion, the new deuterated material is promising for use in fast neutron spectroscopy without the need for time-of-flight measurements.

36 MATERIALS SCIENCE↗

INSTRUMENT PERFORMANCE IN KEPLER's FIRST MONTHS

The Kepler Mission relies on precise differential photometry to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on timescales up to {approx}2 days and systematic error removal to better than 20 ppm. To this end, the spacecraft and photometer underwent 67 days of commissioning, which included several data sets taken to characterize the photometer performance. Because Kepler has no shutter, we took a series of dark images prior to the dust cover ejection, from which we measured the bias levels, dark current, and read noise. These basic detector properties are essentially unchanged from ground-based tests, indicating that the photometer is working as expected. Several image artifacts have proven more complex than when observed during ground testing, as a result of their interactions with starlight and the greater thermal stability in flight, which causes the temperature-dependent artifact variations to be on the timescales of transits. Because of Kepler's unprecedented sensitivity and stability, we have also seen several unexpected systematics that affect photometric precision. We are using the first 43 days of science data to characterize these effects and to develop detection and mitigation methods that will be implemented in the calibration pipeline. Based on early testing, we expect to attain Kepler's planned photometric precision over 80%-90% of the field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscale Particulate Classifiers (MiPAC) Being Developed

The NASA Glenn Research Center is developing microscale sensors to characterize atmospheric-borne particulates. The devices are fabricated using MEMS (microelectromechanical systems) technologies. These technologies are derived from those originally developed in support of the semiconductor processing industry. The resulting microsensors can characterize a wide range of particles and are, therefore, suitable to a broad range of applications. This project is supported under a collaborative program called the Glennan Microsystems Initiative. The initiative comprises members of NASA Glenn Research Center, various university affiliates from the State of Ohio, and a number of participating industrial partners. Funding is jointly provided by NASA, the State of Ohio, and industrial members. The work described here is a collaborative arrangement between researchers at Glenn, the University of Minnesota, The National Institute of Standards and Technology (NIST), and the Cleveland State University. Actual device fabrication is conducted at Glenn and at the laboratories of Case Western Reserve University. Case Western is also located in Cleveland, Ohio, and is a participating member of the initiative. The principal investigator for this project is Paul S. Greenberg of Glenn. Two basic types of devices are being developed, and target different ranges of particle sizes. The first class of devices, which is used to measure nanoparticles (i.e., particles in the range of 0.002 to 1 mm), is based on the technique of Electrical Mobility Classification. This technique also affords the valuable ability of measuring the electrical charge state of the particles. Such information is important in the understanding of agglomeration mechanisms and is useful in the development of methods for particle repulsion. The second type of device being developed, which utilizes optical scattering, is suitable for particles larger than 1 mm. This technique also provides information on particle shape and composition. Applications for these sensors include fundamental planetary climatology, monitoring and filtration in spacecraft, human habitation modules and related systems, characterization of particulate emissions from propulsion and power systems, and as early warning sensors for both space-based and ter-restrial fire detection. These devices are also suitable for characterizing biological compounds such as allergens, infectious agents, and biotoxic agents.

Greenberg, Paul S.↗

Using the HHT to Search for Gravitational Waves

Gravitational waves are a consequence of Einstein's theory of general relativity applied to the motion of very dense and massive objects such as black holes and neutron stars. Their detection will reveal a wealth of information about these mysterious objects that cannot be obtained with electromagnetic probes. Two projects are underway to attempt the detection of gravitational waves: NASA's Laser Interferometer Space Antenna (LISA), a space based mission being designed to search for waves from supermassive black holes at the centers of galaxies, and the NSF's Laser Interferometer Gravitational Wave Observatory (LIGO), a ground based facility that is now searching for waves from supernovae. pulsars, and the coalescence of black hole and neutron star systems. Because general relativity is an inherently non-linear theory, many of the predicted source waveforms show strong frequency modulation. In addition, the LIGO and LISA detectors are highly sensitive devices that produce a variety of non-linear transient noise features. Thus the unique capabilities of the HHT. the extraction of intrawave modulation and the characterization of non-linear and non-stationary signals, have a natural application to both signal detection and experimental characterization of the detectors. In this talk I will give an overview of the status of the field. including some of the expected sources of gravitational waves, and I will also describe the LISA and LIGO detectors. Then I will describe some applications of the HHT to waveform detection and detector noise characterization.

Camp, Jordan↗

Characterization of dangling bond defects at the crystalline Si/SiO x interface in a polycrystalline Si passivating contact solar cell at room temperature with electrically detected magnetic resonance spectroscopy

Monocrystalline silicon solar cells can achieve photoconversion efficiencies exceeding 26%; however, performance-limiting defects that trap carriers continue to be a challenge. In this work, we have characterized Si solar cells with tunneling SiO x /polycrystalline-Si (poly-Si) passivating contacts (TOPCon) on As-doped Czochralski Si wafers with electrically detected magnetic resonance (EDMR) spectroscopy. We fabricated 2 × 20 mm 2 TOPCon-like mini solar cells with edge passivation alongside larger 4 cm 2 sister cells and obtained similar device characteristics. We performed EDMR spectroscopy at 300 K on two minicells with different degrees of surface passivation based on the recombination parameter, J o , values of 40 and 310 fA/cm2. We optimized the resolution and the signal-to-noise ratio of the EDMR response of the minicells by varying the forward bias voltage and the magnetic field modulation amplitude. We detect two distinct signals with EDMR spectroscopy, an axial-like signal at g = 2.009, 2.0087, and 2.0015, and an isotropic signal at g = 2.0024, which we attribute to Si dangling bonds (P b0 and P b centers) and boron–oxygen related defects, respectively, at or near the c-Si/SiO x interface. The EDMR signals were lower for the cell with a lower value of J o , while the ratio of the two defect populations was very similar. The EDMR signal increases with forward bias but drops to zero at bias voltages >0.5 V, consistent with interface defects within or near the boron-doped emitter depletion region. Our study demonstrates a method to fabricate minicells that can be characterized with EDMR spectroscopy to detect industrially relevant defects in TOPCon cells.

14 SOLAR ENERGY↗

Shear Stress Sensing using Elastomer Micropillar Arrays

The measurement of shear stress developed as a fluid moves around a solid body is difficult to measure. Stresses at the fluid-solid interface are very small and the nature of the fluid flow is easily disturbed by introducing sensor components to the interface. To address these challenges, an array of direct and indirect techniques have been investigated with various advantages and challenges. Hot wire sensors and other indirect sensors all protrude significantly into the fluid flow. Microelectromechanical systems (MEMS) devices, although facilitating very accurate measurements, are not durable, are prone to contamination, and are difficult to implement into existing model geometries. One promising approach is the use of engineered surfaces that interact with fluid flow in a detectable manner. To this end, standard lithographic techniques have been utilized to generate elastomeric micropillar arrays of various lengths and diameters. Micropillars of controlled length and width were generated in polydimethylsiloxane (PDMS) elastomer using a soft-lithography technique. The 3D mold for micropillar replication was fabricated using laser ablative micromachining and contact lithography. Micropillar dimensions and mechanical properties were characterized and compared to shear sensing requirements. The results of this characterization as well as shear stress detection techniques will be discussed.

Wohl, Christopher J.↗

Characterizing the best cosmic telescopes with the millennium simulations

Certain configurations of massive structures projected along the line of sight (LOS) maximize the number of detections of gravitationally lensed z ∼ 10 galaxies. We characterize such LOSs with the étendue σ{sub μ}, the area in the source plane magnified over some threshold μ. We use the Millennium I and Millennium XXL cosmological simulations to determine the frequency of high σ{sub μ} beams on the sky, their properties, and efficient selection criteria. We define the best beams as having σ{sub μ>3} > 2000 arcsec{sup 2}, for a z ∼ 10 source plane, and predict 477 ± 21 such beams on the sky. The total mass in the beam and σ{sub μ>3} are strongly correlated. After controlling for total mass, we find a significant residual correlation between σ{sub μ>3} and the number of cluster-scale halos (>10{sup 14} M {sub ☉} h {sup –1}) in the beam. Beams with σ{sub μ>3} > 2000 arcsec{sup 2}, which should be best at lensing z ∼ 10 galaxies, are 10 times more likely to contain multiple cluster-scale halos than a single cluster-scale halo. Beams containing an A1689-like massive cluster halo often have additional structures along the LOS, including at least one additional cluster-scale (M {sub 200} > 10{sup 14} M {sub ☉} h {sup –1}) halo 28% of the time. Selecting beams with multiple, massive structures will lead to enhanced detection of the most distant and intrinsically faint galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources

Examinations of bremsstrahlung and energetic electron beams from a novel laser plasma source motivate and assist characterization of a backthinned, backilluminated direct detection x-ray charge-coupled device (CCD), a topology that is uncommon in hard x-ray work. Behavior toward pseudomonochromatic ({sup 55}Fe) and multichromatic ({sup 241}Am) sources is briefly reviewed under optimized noise conditions. Results collectively establish the previously unknown functional depth structure. Several modes of usage are illustrated in {approx}4-20 keV x-ray laser plasma source investigations, where the significance of the characterization is briefly discussed. The spectral redistribution associated with this CCD topology is unfavorable, yet appropriate analysis ensures that sufficient spectral information remains for quantitative determination of broadband x-ray flux and spectra in essentially single laser shot measurements. The energy dependence of nascent electron cloud radii in silicon is determined using broadband x-rays from the laser plasma source, turning the narrow depletion depth to advantage. Finally, the characterization is used to quantify recent x-ray spectral explorations of the water jet laser plasma source operating under aspirator vacuum. These results will have key value for establishment of laboratory based ultrafast extended x-ray absorption fine structure experiments using microbolometric detectors.

43 PARTICLE ACCELERATORS↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensing strategies for toxic vapor detection

This work was motivated by the recommendations of the American Conference of Governmental Industrial Hygienists (ACGIH) that threshold limits for hydrazine, H2N-NH2 in air be lowered from 100 to 10 parts-per-billion (ppb) concentration levels. Hydrazine is one of the high-energy propellants used in large volumes in Space Shuttle, Titan, payloads, and other aerospace operations. Since analytical methods presently available for hydrazine detection and/or determination do not satisfy such low levels of detection, the ultimate goal of this research is the development and characterization of a portable and compact chemical sensor ideally capable to detect (in real time) 1 ppb of hydrazine, continuously and reversibly. The laboratory prototype developed as part of this project is comprised of: (1) a reactor part in which H2N-NH2 reacts, generating chemiluminescence emission, with tris(2,2'-bipyridine)ruthenium(III), which is immobilized on an ion-exchange polymeric materials of a perfluorinated hydrocarbon containing sulfonate groups as exchange centers (Nafion); (2) an electrochemical three-electrode cell posed at a potential at which the immobilized ruthenium complex could be reoxidized to the 3-oxidation state (as to provide reversible and continuous detection); and (3) a low power consumption photomultiplier tube to collect and quantitatively integrate the emitted photons with the help of auxiliary electronics and readout device.

Mottola, Horacio A.↗

SU-E-J-149: Secondary Emission Detection for Improved Proton Relative Stopping Power Identification

Purpose: This research investigates application of secondary prompt gamma (PG) emission spectra, resulting from nuclear reactions induced by protons, to characterize tissue composition along the particle path. The objective of utilizing the intensity of discrete high-energy peaks of PG is to improve the accuracy of relative stopping power (RSP) values available for proton therapy treatment planning on a patient specific basis and to reduce uncertainty in dose depth calculations. Methods: In this research, MCNP6 was used to simulate PG emission spectra generated from proton induced nuclear reactions in medium of varying composition of carbon, oxygen, calcium and nitrogen, the predominant elements found in human tissue. The relative peak intensities at discrete energies predicted by MCNP6 were compared to the corresponding atomic composition of the medium. Results: The results have shown a good general agreement with experimentally measured values reported by other investigators. Unexpected divergence from experimental spectra was noted in the peak intensities for some cases depending on the source of the cross-section data when using compiled proton table libraries vs. physics models built into MCNP6. While the use of proton cross-section libraries is generally recommended when available, these libraries lack data for several less abundant isotopes. This limits the range of their applicability and forces the simulations to rely on physics models for reactions with natural atomic compositions. Conclusion: Current end-of-range proton imaging provides an average RSP for the total estimated track length. The accurate identification of tissue composition along the incident particle path using PG detection and characterization allows for improved determination of the tissue RSP on the local level. While this would allow for more accurate depth calculations resulting in tighter treatment margins, precise understanding of proton beam behavior in tissue of various compositions is necessary requiring detailed simulations with a high degree of accuracy.

60 APPLIED LIFE SCIENCES↗

Abnormal fault-recovery characteristics of the fault-tolerant multiprocessor uncovered using a new fault-injection methodology

An investigation was made in AIRLAB of the fault handling performance of the Fault Tolerant MultiProcessor (FTMP). Fault handling errors detected during fault injection experiments were characterized. In these fault injection experiments, the FTMP disabled a working unit instead of the faulted unit once in every 500 faults, on the average. System design weaknesses allow active faults to exercise a part of the fault management software that handles Byzantine or lying faults. Byzantine faults behave such that the faulted unit points to a working unit as the source of errors. The design's problems involve: (1) the design and interface between the simplex error detection hardware and the error processing software, (2) the functional capabilities of the FTMP system bus, and (3) the communication requirements of a multiprocessor architecture. These weak areas in the FTMP's design increase the probability that, for any hardware fault, a good line replacement unit (LRU) is mistakenly disabled by the fault management software.

Padilla, Peter A.↗

Metrics for Developing an Endorsed Set of Radiographic Threat Surrogates for JINII/CAARS

CAARS (Cargo Advanced Automated Radiography System) is developing x-ray dual energy and x-ray backscatter methods to automatically detect materials that are greater than Z=72 (hafnium). This works well for simple geometry materials, where most of the radiographic path is through one material. However, this is usually not the case. Instead, the radiographic path includes many materials of different lengths. Single energy can be used to compute {mu}y{sub l} which is related to areal density (mass per unit area) while dual energy yields more information. This report describes a set of metrics suitable and sufficient for characterizing the appearance of assemblies as detected by x-ray radiographic imaging systems, such as those being tested by Joint Integrated Non-Intrusive Inspection (JINII) or developed under CAARS. These metrics will be simulated both for threat assemblies and surrogate threat assemblies (such as are found in Roney et al. 2007) using geometrical and compositional information of the assemblies. The imaging systems are intended to distinguish assemblies containing high-Z material from those containing low-Z material, regardless of thickness, density, or compounds and mixtures. The systems in question operate on the principle of comparing images obtained by using two different x-ray end-point energies--so-called 'dual energy' imaging systems. At the direction of the DHS JINII sponsor, this report does not cover metrics that implement scattering, in the form of either forward-scattered radiation or high-Z detection systems operating on the principle of backscatter detection. Such methods and effects will be covered in a later report. The metrics described here are to be used to compare assemblies and not x-ray radiography systems. We intend to use these metrics to determine whether two assemblies do or do not look the same. We are tasked to develop a set of assemblies whose appearance using this class of detection systems is indistinguishable from the real threats. To check such an indistinguishability, we must define metrics that are broad enough to cover systems of different source spectra and detector spectral response; in other words, the best metrics should capture physical properties of the assemblies and not the source and detectors employed. In fact, one requirement for the metrics is that, as the detection circumstances change, the similarity or difference of the metrics of two assemblies should be maintained. This report describes the set of two simple 'dual energy' metrics that we have selected. A second report (Wurtz, et al. 2009) goes on to demonstrate several characteristics of the metrics, including how sensitive they are (or are not) to changes in the detection systems, shielding, etc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular characterization of a new monopartite dsRNA mycovirus from mycorrhizal Thelephora terrestris (Ehrh.) and its detection in soil oribatid mites (Acari: Oribatida)

A novel dsRNA virus was identified in the mycorrhizal fungus Thelephora terrestris (Ehrh.) and sequenced. This virus, named Thelephora terrestris virus 1 (TtV1), contains two reading frames in different frames but with the possibility that ORF2 could be translated as a fusion polyprotein after ribosomal -1 frameshifting. Picornavirus 2A-like motif, nudix hydrolase, phytoreovirus S7, and RdRp domains were found in a unique arrangement on the polyprotein. A new genus named Phlegivirus and containing TtV1, PgLV1, RfV1 and LeV is therefore proposed. Twenty species of oribatid mites were identified in soil material in the vicinity of T. terrestris. TtV1 was detected in large amounts in Steganacarus (Tropacarus) carinatus (C.L. Koch, 1841) and in much smaller amounts in Nothrus silvestris (Nicolet). This is the first description of mycovirus presence in oribatid mites. - Highlights: • A novel dsRNA virus was identified in the mycorrhizal fungus Thelephora terrestris. • A new virus genus Phlegivirus is proposed. • The mycovirus was firstly detected in oribatid mites.

60 APPLIED LIFE SCIENCES↗

Point source polarimetry with the Gemini Planet Imager: Sensitivity characterization with T5.5 dwarf companion HD 19467 B

Detecting polarized light from self-luminous exoplanets has the potential to provide key information about rotation, surface gravity, cloud grain size, and cloud coverage. While field brown dwarfs with detected polarized emission are common, no exoplanet or substellar companion has yet been detected in polarized light. With the advent of high contrast imaging spectro-polarimeters such as GPI and SPHERE, such a detection may now be possible with careful treatment of instrumental polarization. In this paper, we present 28 minutes of H-band GPI polarimetric observations of the benchmark T5.5 companion HD 19467 B. We detect no polarization signal from the target, and place an upper limit on the degree of linear polarization of p{sub CL99.73%}⩽2.4%. We discuss our results in the context of T dwarf cloud models and photometric variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Point Source Polarimetry with the Gemini Planet Imager: Sensitivity Characterization with T5.5 Dwarf Companion HD 19467 B

Detecting polarized light from self-luminous exoplanets has the potential to provide key information about rotation, surface gravity, cloud grain size, and cloud coverage. While field brown dwarfs with detected polarized emission are common, no exoplanet or substellar companion has yet been detected in polarized light. With the advent of high contrast imaging spectro-polarimeters such as GPI and SPHERE, such a detection may now be possible with careful treatment of instrumental polarization. In this paper, we present 28 minutes of H-band GPI polarimetric observations of the benchmark T5.5 companion HD 19467 B. We detect no polarization signal from the target, and place an upper limit on the degree of linear polarization of pCL99:73% less than 1:7%. We discuss our results in the context of T dwarf cloud models and photometric variability.

Gemini Planet Imager↗

The NREL Sensor Laboratory: Status and Future Directions for Hydrogen Detection

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for the national and international hydrogen community to ensure the availability and proper use of hydrogen sensors. Since then, the Sensor Laboratory has provided unbiased verification of hydrogen sensor performance for sensor developers, end-users, and regulatory agencies and has also provided active support for numerous code and standards development organizations. Although sensor performance assessment remains a core capability, the mission of the NREL Sensor Laboratory has expanded toward a more holistic approach regarding the role of hydrogen detection and its implementation strategy for both assurance of facility safety as well as for process control applications. Active monitoring for detection of unintended releases has been identified by the NFPA 2 Storage Task Group as a viable approach for improving facility safety and lowering setbacks. The current research program for the Sensor Laboratory addresses both conventional and advanced developing detection strategies in response to the emerging large-scale markets, such as those envisioned by H2@Scale. These emerging hydrogen applications may require alternative detection strategies that supplement and may ultimately supplant the use of traditional sensors for monitoring hydrogen releases. Research focus areas for the NREL Sensor Laboratory now encompasses the characterization of released hydrogen behavior to optimize detection strategies for both indoor and outdoor applications, advanced methods of hydrogen leak detection such as hydrogen wide area monitoring approaches for large scale and distributed applications, the incorporation of active monitoring as a risk reduction strategy to improve safety at hydrogen facilities, and continuing support of hydrogen safety codes and standards. In addition to assurance of safety, detection will be critical for process control applications, such as hydrogen fuel quality verification for fuel cell vehicle applications and for monitoring and controlling of hydrogen-natural gas blend composition.

codes and standards↗

EVALUATION OF BALLISTIC DAMAGE IN AN ENCAPSULATED CERAMIC PANEL VIA X-RAY COMPUTED TOMOGRAPHY

X-ray computed tomography (XCT) is an important non-destructive evaluation technique for revealing the spatial distribution of ballistically-induced damage in ceramics. The level of detection and resolution of damage depends on the size of the sample and the parameters of the XCT approach (e.g., focal spot size, magnification, etc.). Previous and ongoing work in this area includes assessment of ballistically induced damage in both individual ceramic targets and ceramic armor panels. Ballistic damage in an encapsulated ceramic armor panel with a metal backing has been scanned and extensively evaluated using XCT 2-D and 3-D analysis. The purpose of using XCT evaluation in this study was to better characterize and understand all of the detectable damage. This information can be used to correlate damage features and types with the physical processes of damage initiation and growth. XCT scans and analyses of damage in the panel will be shown and discussed. This will include virtual 3-D solid visualizations and some quantitative analysis of damage features.

36 MATERIALS SCIENCE↗