Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Core plasma physics basis and its impacts on the FNSF

The FNSF core plasma physics is reportede on with detailed analysis to establish the basis for the reference configuration, R = 4.8 m, a = 1.2 m, Ip = 7.87 MA, and B T = 7.5 T, q 95 = 6, f BS = 0.52, β N < 2.7 established in Ref. [1]. Central solenoid (CS) and poloidal field (PF) coils are far from the plasma as in a power plant, and acceptable coil currents are determined for the rampup and flattop fiducial states. Time-dependent free-boundary plasma evolution simulations demonstrate that the FNSF plasma can be established, ramped up, and relaxed into flattop, including vertical stabilizers, internal feedback coils and feedback control on plasma current, position, and shape. A range of density (n o / = 1.3–1.5) and temperature (T o / = 2.2–2.7) profiles are examined, indicating that energy confinement of H 98 = 1.1–1.2 is required to provide 100% non-inductive plasma current in the FNSF. GLF23 theory based transport model predicted lower energy confinement of H 98 ~0.6–0.85. The EPED analysis shows that the pedestal temperature ranges from 4.0–4.7 keV for pedestal densities of 1.7–1.0 × 10 20 /m 3 . The n = 1 kink stability shows no-wall beta limits, using the pressure and current profiles associated with the transport and current drive sources, ranging from β N ~2.25–2.55 depending on l i . A conducting wall can extend these limits by 10–40% depending on li and wall location. At the lower beta’s of the reference plasma, a combination of 50 MW of NB, 30 MW of LH, 20 MW of ICRF, 20 MW of EC, and bootstrap current, are found to provide 100% of the plasma current with a stable current profile. Impacts on the FNSF of plasma physics are discussed and R&D challenges are recorded.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual magnet design study for fusion nuclear science facility [Magnet design study for fusion nuclear science facility]

The Fusion Nuclear Science Facility (FNSF) is a nuclear confinement device to provide the integrated fusion environment with fusion reactor components. The FNSF is the stepping stone to bridge the technical gaps of burning plasma and nuclear science between the International Thermal Nuclear Experimental Reactor (ITER), currently under construction in the south of France, and the demonstration power plant (DEMO). For the next-step fusion reactors, resistive copper magnet cannot be a sustainable solution due to large power consumption in coils of large size needed. Both Low temperature superconductor (LTS) and high temperature superconductor (HTS) are considered for the FNSF magnet design based on the state-of-the-art fusion superconducting magnet technology. Input parameters to FNSF magnet design include magnetic field of 7.5 T at plasma center with a major radius of 4.8 m and minor radius of 1.2 m, and a peak field of over 16 T on the TF coils. The high magnetic field can be achieved by using the high performance ternary Restack Rod Process (RRP) Nb3Sn strands for toroidal field (TF) magnets and a high aspect ratio rectangular cable-in-conduit conductor (CICC) design. The conductor design concept and TF coil winding pack composition and dimension are discussed based on the horizontal maintenance scheme. Neutron radiation limits for the LTS and HTS conductors and electrical insulation materials are reviewed based on the available materials previously tested. The material radiation limits for FNSF magnets are defined as part of the conceptual design studies. In conclusion, the global structural analysis of FNSF magnets based on the radial build was performed to validate feasibility for the plant layout toward horizontal maintenance and global structural integrity of its magnet system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electronic Characterization of Lithographically Patterned Microcoils for High Sensitivity NMR Detection

Nuclear magnetic resonance (NMR) offers a non-destructive, powerful, structure-specific analytical method for the identification of chemical and biological systems. The use of radio frequency (RF) microcoils has been shown to increase the sensitivity in mass limited samples. Recent advances in micro-receiver technology have further demonstrated a substantial increase in mass sensitivity [1]. Lithographic methods for producing solenoid microcoils possess a level of flexibility and reproducibility that exceeds previous production methods, such as hand winding microcoils. This paper presents electrical characterizations of RF microcoils produced by a unique laser lithography system that can pattern three dimensional surfaces and compares calculated and experimental results to those for wire wound RF microcoils. We show that existing optimization conditions for RF coil design still hold true for RF microcoils produced by lithography. Current lithographic microcoils show somewhat inferior performance to wire wound RF microcoils due to limitations in the existing electroplating technique. In principle, however, when the pitch of the RF microcoil is less than 100 {micro}m lithographic coils should show comparable performance to wire wound coils. In the cases of larger pitch, wire cross sections can be significantly larger and resistances lower than microfabricated conductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Suppression of probe background signals via B1 field inhomogeneity

A new approach combining a long pulse with the DEPTH sequence (Cory and Ritchey, Journal of Magnetic Resonance, 1988) greatly improves the efficiency for suppressing probe background signals arising from spinning modules. By applying a long initial excitation pulse in the DEPTH sequence, instead of a {pi}/2 pulse, the inhomogeneous B{sub 1} fields outside the coil can dephase the background coherence in the nutation frame. The initial long pulse and the following two consecutive EXORCYCLE {pi} pulses function complementarily and prove most effective in removing background signals from both strong and weak B{sub 1} fields. Experimentally, the length of the long pulse can be optimized around odd multiples of the {pi}/2 pulse, depending on the individual probe design, to preserve signals inside the coil while minimizing those from probe hardware. This method extends the applicability of the DEPTH sequence to probes with small differences in B{sub 1} field strength between the inside and outside of the coil, and can readily combine with well-developed double resonance experiments for quantitative measurement. In general, spin systems with weak internal interactions are required to attain efficient and uniform excitation for powder samples, and the principles to determine the applicability are discussed qualitatively in terms of the relative strength of spin interactions, r.f. power and spinning rate.

47 OTHER INSTRUMENTATION↗

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

The effect of finish rolling temperature and tempering on the microstructure, mechanical properties and dislocation density of direct-quenched steel

Highlights: • The effect of thermomechanical treatment and tempering on direct-quenched steel has been studied. • Dislocation density of direct-quenched and tempered martensite is evaluated using both TEM and Williamson-Hall method. • Statistical analysis has been performed to study the effect of different factors on toughness of direct-quenched martensite. - Abstract: A unique batch tempering treatment for industrial scale direct-quenched steel coils has been studied using laboratory simulations. The tempering treatment was non-isothermal with slow heating to 570 °C and slow cooling to simulate the tempering of large steel coils. The paper presents the effect of finishing rolling temperature (FRT) relative to the non-recrystallization temperature (T{sub NR}) and the effect of long time tempering on the microstructure, dislocation density and mechanical properties of direct-quenched coiled strips. Conditioning austenite below the recrystallization stop temperature resulted in a finer effective grain size distribution, which correlated strongly with the impact toughness of the final product. Furthermore low finish rolling temperature resulted in partially ferritic microstructures while higher finishing rolling temperatures led to mixtures of bainite and martensite. Dislocation densities determined with TEM and XRD showed somewhat different trends regarding the effect of tempering: intra-lath dislocation density, as measured with TEM, showed a statistically significant drop in only one case, while XRD analysis indicated a drop in all cases. Furthermore, no significant correlation between finishing rolling temperature and dislocation density existed in XRD studies. The XRD results indicate that the decrease in dislocation density corresponds to about 100 MPa lower dislocation strengthening. However, precipitation hardening and potential internal micro stress relief compensates this as yield strength remains unchanged or even increases during tempering.

36 MATERIALS SCIENCE↗

Effects of the size of nano-copper catalysts and reaction temperature on the morphology of carbon fibers

In this study, carbon fibers with different morphologies, including coiled carbon nanofibers and straight carbon fibers, were obtained by the chemical vapor deposition using a Cu-catalytic pyrolysis of acetylene at 250 deg. C. The influences of nano-copper catalyst particle size and the reaction temperature on the morphology of carbon fibers were investigated. Under the same reaction condition, coiled carbon nanofibers generally were synthesized using nano-copper catalyst with smaller particles size, and bigger copper particles are apt to produce straight carbon fibers. With decreasing of reaction temperature to 200 deg. C, straight carbon fibers were obtained, instead of coiled carbon nanofibers at 250 deg. C. The product was characterized by field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) and X-ray powder diffraction (XRD)

36 MATERIALS SCIENCE↗

Magnetic field analysis and achievable on-axis field for helical undulators.

The on- and off-axis magnetic fields for infinitely long, helical undulators were analyzed for linear and nonlinear poles. An analytical expression of the on-axis field for linear poles was derived in terms of coil current density, undulator period length, and coil dimensions. The derived expression showed that, when the undulator dimensions were scaled according to the period ratios, the on-axis fields were proportional to the periods, which is in agreement with calculations of model undulators. For undulators with nonlinear steel poles, when the undulator dimensions were scaled, the field distributions remained unchanged for a constant value of (current density x period). It was also shown that, for two scaled undulators, one with linear and one with nonlinear poles, the off-axis field components, normalized to the respective on-axis fields, had the same field distributions near the axis within the calculation errors. This implies that the derived normalized off-axis field for linear poles may be used for beam dynamic analysis in the fields of undulators with nonlinear poles within the beam chamber. Achievable on-axis fields were calculated for short-period undulators with parameters close to those for the proposed International Linear Collider (ILC) positron production undulators. The required undulator parameters for the ILC appear to be achievable depending on the Nb{sub 3}Sn superconductor packing factor in the coil and on how close the chosen operating current is to the critical current.

36 MATERIALS SCIENCE↗

Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10 -7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 superconducting magnets

As part of the Jefferson Lab 12 GeV upgrade, the Hall B CLAS12 system requires two superconducting iron-free magnets — a torus and a solenoid. The physics requirements to maximize space for the detectors guided engineers toward particular coil designs for each of the magnets which, in turn, led to the choice of using conduction cooling. The torus consists of 6 trapezoidal NbTi coils connected in series with an operating current of 3770 A. The solenoid is an actively shielded 5 T magnet consisting of 5 NbTi coils connected in series operating at 2416 A. Within the hall, the two magnets are located in close proximity to each other and are completely covered both inside and outside by particle detectors. Stringent size limitations were imposed for both magnets and introduced particular design and fabrication challenges. This paper describes the design, construction, installation, commissioning, and operation of the two magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancing the physics basis for quasi-helically symmetric stellarators

A new optimized quasi-helically symmetric configuration is described that has the desirable properties of improved energetic particle confinement, reduced turbulent transport by three-dimensional shaping and non-resonant divertor capabilities. The configuration presented in this paper is explicitly optimized for quasi-helical symmetry, energetic particle confinement, neoclassical confinement and stability near the axis. Post optimization, the configuration was evaluated for its performance with regard to energetic particle transport, ideal magnetohydrodynamic stability at various values of plasma pressure and ion temperature gradient instability induced turbulent transport. The effects of discrete coils on various confinement figures of merit, including energetic particle confinement, are determined by generating single-filament coils for the configuration. Preliminary divertor analysis shows that coils can be created that do not interfere with expansion of the vessel volume near the regions of outgoing heat flux, thus demonstrating the possibility of operating a non-resonant divertor.

Physics↗

Fast-ion physics in SPARC

Potential loss of energetic ions including alphas and radio-frequency tail ions due to classical orbit effects and magnetohydrodynamic instabilities (MHD) are central physics issues in the design and experimental physics programme of the SPARC tokamak. The expected loss of fusion alpha power due to ripple-induced transport is computed for the SPARC tokamak design by the ASCOT and SPIRAL orbit-simulation codes, to assess the expected surface heating of plasma-facing components. We find good agreement between the ASCOT and SPIRAL simulation results not only in integrated quantities (fraction of alpha power loss) but also in the spatial, temporal and pitch-angle dependence of the losses. If the toroidal field (TF) coils are well-aligned, the SPARC edge ripple is small (0.15–0.30 %), the computed ripple-induced alpha power loss is small ( ~0.25% ) and the corresponding peak surface power density is acceptable ( 244 kW m -2 ). However, the ripple and ripple-induced losses increase strongly if the TF coils are assumed to suffer increasing magnitudes of misalignment. Surface heat loads may become problematic if the TF coil misalignment approaches the centimetre level. Ripple-induced losses of the energetic ion tail driven by ion cyclotron range of frequency (ICRF) heating are not expected to generate significant wall or limiter heating in the nominal SPARC plasma scenario. Because the expected classical fast-ion losses are small, SPARC will be able to observe and study fast-ion redistribution due to MHD including sawteeth and Alfvén eigenmodes (AEs). SPARC's parameter space for AE physics even at moderate Q is shown to reasonably overlap that of the demonstration power plant ARC (Sorbom et al., Fusion Engng Des., vol. 100, 2015, p. 378), and thus measurements of AE mode amplitude, spectrum and associated fast-ion transport in SPARC would provide relevant guidance about AE behaviour expected in ARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An adjoint method for determining the sensitivity of island size to magnetic field variations

An adjoint method to calculate the gradient of island width in stellarators is presented and applied to a set of magnetic field configurations. The underlying method for calculation of the island width is that of Cary & Hanson ( Phys. Fluids B, vol. 3, issue 4, 1991, pp. 1006–1014) (with a minor modification), and requires that the residue of the island centre be small. Therefore, the gradient of the residue is calculated in addition. Both the island width and the gradient calculations are verified using an analytical magnetic field configuration introduced by Reiman & Greenside ( Comput. Phys. Commun. , vol. 43, issue 1, 1986, pp. 157–167). The method is also applied to the calculation of the shape gradient of the width of a magnetic island in a National Compact Stellarator Experiment (NCSX) vacuum configuration with respect to positions on a coil. A gradient-based optimization is applied to a magnetic field configuration studied by Hanson & Cary ( Phys. Fluids , vol. 27, issue 4, 1984, pp. 767–769) to minimize stochasticity by adding perturbations to a pair of helical coils. Although only vacuum magnetic fields and an analytical magnetic field model are considered in this work, the adjoint calculation of the island width gradient could also be applied to a magnetohydrodynamic (MHD) equilibrium if the derivative of the magnetic field, with respect to the equilibrium parameters, is known. Using the island width gradient calculation presented here, more general gradient-based optimization methods can be applied to design stellarators with small magnetic islands. Moreover, the sensitivity of the island size may itself be optimized to ensure that coil tolerances, with respect to island size, are kept as high as possible.

Physics↗

Neural network reconstruction of the DIII-D tokamak plasma boundary using a reduced set of diagnostics

This study investigates the feasibility of reconstructing the last closed flux surface in the DIII-D tokamak using neural network models trained on reduced input feature sets, addressing an ill-posed task. Two models are compared: one trained solely on coil currents and another incorporating coil currents, plasma current and loop voltage. The model trained exclusively on coil currents achieved a mean point displacement of $0.04$ m on a held-out test set, while the inclusion of plasma current and loop voltage reduced the error to $0.03$ m. This comparison highlights the trade-offs between input feature complexity and reconstruction accuracy, demonstrating the potential of machine learning algorithms to perform effectively in data-limited environments, such as those expected in fusion power plants due to diagnostic constraints imposed by the presence of blankets and shielding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Organophilic, Superparamagnetic, and Reversibly Thermoresponsive Silica-Polypeptide Core–Shell Particles

Particles with a superparamagnetic cobalt inner core, silica outer core, and covalently bound homopolypeptide shell were investigated under thermal and magnetic stimuli. The homopolypeptide was poly(ε-carbobenzyloxy- l -lysine), PCBL, which is known to exhibit a thermoreversible coil ⇔ helix transition when dissolved as a pure polymer in m- cresol. Tethering to a core particle did not prevent PCBL from undergoing this conformational transition, as confirmed by dynamic light scattering and optical rotation, but the transition was broadened compared to that of the untethered polymer. The Co@SiO 2 -PCBL hybrid particles retained the superparamagnetic properties of the cobalt inner nougat. Indeed, some response remains even after aging for >5 years. The aged PCBL shell also preserved its responsiveness to temperature, although differences in the shape of the size vs temperature transition curve were determined compared to the freshly made particles. A reversible coil ⇔ helix transition for a particle-bound polypeptide in a pure organic solvent is rare. Further to providing a convenient tool for characterizing coil ⇔ helix transitions for surface-bound polypeptides without interference from pH or the strong ionic forces that dominate behavior in aqueous systems, the Co@SiO 2 -PCBL/ m -cresol system may prove useful in studies of the effect of shell polymer conformation on colloid interactions. The stability of the magnetic core and polypeptide shell suggest a long shelf life for Co@SiO 2 -PCBL, which can, in principle, be deprotected to yield positively charged Co@SiO 2 -poly( l -lysine) particles for possible transfection or antimicrobial applications or chained magnetically to produce responsive poly(colloids).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scattering Neutrons along the Polyelectrolyte Complex/Coacervate Continuum

The coil size of narrow molecular weight distribution deuterated poly(styrenesulfonate), PSS, within a polyelectrolyte complex doped with KBr was tracked across the continuum from solid to coacervate to solution using small-angle neutron scattering. Here, while PSS alone in solution exhibited the familiar and pronounced “polyelectrolyte effect” of coil shrinkage with increasing [KBr], the radius of gyration R g of the PSS in the complex remained surprisingly constant up to 1.4 M KBr, which is close to the transition between complex and coacervate behavior. Thereafter, R g decreased with increasing KBr, remaining slightly larger than R g for PSS in KBr alone. Upturns in the scattering at low angle, seen for complexes in lower [KBr], are consistent with porosity, observed macroscopically as whitening of the bulk complex—a universal property of polyelectrolyte complexes. Reasons for this porosity, imaged by scanning electron microscopy, are discussed. At high q ranges, a correlation peak between deuterated coils of PSS was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetically Controlled Nanostructure Formation in Self-Assembled Globular Protein–Polymer Diblock Copolymers

Aqueous processing of globular protein–polymer diblock copolymers into solid-state materials and subsequent solvent annealing enables kinetic and thermodynamic control of nanostructure formation to produce block copolymer morphologies that maintain a high degree of protein fold and function. When model diblock copolymers composed of mCherry-b-poly(N-isopropylacrylamide) are used, orthogonal control over solubility of the protein block through changes in pH and the polymer block through changes in temperature is demonstrated during casting and solvent annealing. Hexagonal cylinders, perforated lamellae, lamellae, or hexagonal and disordered micellar phases are observed, depending on the coil fraction of the block copolymer and the kinetic pathway used for self-assembly. Here, good solvents for the polymer block produce ordered structures reminiscent of coil–coil diblock copolymers, while an unfavorable solvent results in kinetically trapped micellar structures. Decreasing solvent quality for the protein improves long-range ordering, suggesting that the strength of protein interactions influences nanostructure formation. Subsequent solvent annealing results in evolution of the nanostructures, with the best ordering and the highest protein function observed when annealing in a good solvent for both blocks. While protein secondary structure was found to be almost entirely preserved for all processing pathways, UV–vis spectroscopy of solid-state films indicates that using a good solvent for the protein block enables up to 70% of the protein to be retained in its functional form.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗