Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COST PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report January 2015

Highlights: Mike Worley and Shane Johnson visited INL Jan. 22 for an NSUF strategy discussion; Rory Kennedy attended a NSLS-2 Beamline Advisory Team meeting at Brookhaven; Provided a final cost estimate to the NSUF Program Office in support of the NEET/NSUF proposal, “Metal-ceramic and metal-metal composites for extreme radiation and temperature environment: An in situ interface stability and mechanical behavior study by high energy x-ray diffraction with a synchrotron probe.”; Assisted in the development of conceptual designs and performed a preliminary thermal hydraulic analysis for two NEET/NSUF proposals. The challenge for both experiments is to provide high (>1000 C and up to 1600 C)) specimen temperatures in a small space (0.5" diameter ATR Outboard A-position) without overheating the coolant. Several designs were analyzed and found to be feasible, although detailed design and analysis will be required after the projects are awarded; and A single USU TEM specimen is packaged and awaiting shipment from MFC to CAES. Once at CAES, SEM, TEM and LEAP analysis will be performed. Professor Ban has requested additional sub-samples to be made to take back to his laboratory at USU for thermal diffusivity studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Appendix F – GPRA06 Geothermal Technologies Program Documentation

The primary goal of the Geothermal Technologies Program is to reduce the cost of geothermal generation technologies, including both conventional and enhanced geothermal systems (EGS). EGS are defined as geothermal systems where the reservoir requires substantial engineering manipulation to make using the reservoir economically feasible.

15 GEOTHERMAL ENERGY↗

GPRA Representation of the Geothermal Technologies Program

The primary goal of the Geothermal Program is to reduce the cost of geothermal generation technologies, including both conventional and engineered geothermal source (EGS) systems. Measuring the GPRA benefits involves projecting the market share for these technologies based on their economic and environmental characteristics.

15 GEOTHERMAL ENERGY↗

Appendix F – GPRA05 Geothermal Technologies Program Documentation

The primary goal of the Geothermal Technologies Program is to reduce the cost of geothermal generation technologies, including both conventional and enhanced geothermal systems (EGS). Estimating the GPRA benefits involves projecting the market share for these technologies based on their economic and environmental characteristics.

15 GEOTHERMAL ENERGY↗

Appendix L: GPRA05 Wind and Hydropower Technologies Program documentation

The wind energy component of the Wind and Hydropower Technologies Program seeks to reduce the cost and improve the performance of wind technology, and to reduce barriers to its use. The GPRA benefits are based primarily on model projections of the market share for wind technologies, based on their economic characteristics. This document describes the assumptions that are used by the models to calculate those benefits.

13 HYDRO ENERGY↗

Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report: The Influence of Novel Behavioral Strategies in Promoting the Diffusion of Solar Energy

This is the final report for a systematic, evidence-based project using an unprecedented series of large-scale field experiments to examine the effectiveness and cost-effectiveness of novel approaches to reduce the soft costs of solar residential photovoltaics. The approaches were based around grassroots marketing campaigns called ‘Solarize’ campaigns, that were designed to lower costs and increase adoption of solar technology. This study quantified the effectiveness and cost-effectiveness of the Solarize programs and tested new approaches to further improve the model.

14 SOLAR ENERGY↗

TA55-PMDS Programmatic Maintenance [Slides]

DOE Order 433.1B states: “The contractor must maintain real property assets in a manner that promotes operational safety, worker health, environmental compliance, property preservation and cost-effectiveness while meeting the program mission”. P950 Conduct of Maintenance serves as LANL’s Nuclear Maintenance Management Program specific to M/L 1 and M/L 2 SSC. PA-AP-01108 Maintenance Requirements for Programmatic Equipment defines the process for determining maintenance requirements, as defined in a maintenance plan, for all programmatic equipment owned by the Associate Directorate for Plutonium Science and Manufacturing (ADPSM) utilizing a formal, graded approach to maximize the reliability of permanently-installed programmatic equipment that does not perform a safety function. It bridges the gap between P950 and program equipment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Basis of Estimate Summary - Combined Radiation Environments for Survivability Testing (CREST)

The following document is Sandia National Laboratories Facilities Site and Strategic Partnerships methodology and assumptions used in the assembly of programming, planning, and budgeting level cost range for early capital acquisition needs development and communication. This basis of estimate summary is specific to the Combined Radiation Environments for Survivability Testing (CREST) Line Item proposal, and reflects updated estimates provided by the Subject Matter Experts (SME) team as indicated.

61 RADIATION PROTECTION AND DOSIMETRY↗

LANL Fuel Cell Program [Slides]

Fuel Cell R&D programs are the longest running non-weapons programs at LANL, running since 1977. The current DOE HFTO program grew out of the Los Alamos program. It is primarily polymer electrolyte membrame (PEM) technology. The cost and durability are the biggest barriers to commercialization. The program focus is on obtaining fundamental understanding to enable "knowledge-based innovation," and subsequent materials and process development.

08 HYDROGEN↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Community-Scale AHA Go Solar Initiative and Net Zero Initiative

The Saint Regis Mohawk Tribe is a sovereign, federally acknowledged Indian Tribe. The Tribal Council created the Akwesasne Housing Authority (AHA) by ordinance in July 1984 and has designated the AHA as its agency for purposes of administering the Tribe’s Indian Housing Block Grant under the Native American Housing and Self-Determination Act of 1996. The Go Solar project will install approximately 615 kilowatts (kW) of solar photovoltaic (PV) facilities to serve housing related buildings on the Tribe’s reservation and use net metering programs to reduce the energy costs for AHA and Tribal members by up to $\$$4,417,501 over the life of the project. AHA will initiate four (4) net zero buildings: two (2) new net zero low-income housing buildings located at Sunrise Acres III, which include the Veterans Supportive Housing Building and the Seniors Supportive Housing building, and one (1) older, existing net zero building used by the Akwesasne Boys & Girls Club (ABGC Building), and (1) Tribal Administration Building.

14 SOLAR ENERGY↗

Myths of German Graphite in World War II, with Original Translations

We re-examine the common narrative that a 1941 experimental error by physicists Walther Bothe and Peter Jensen led Germany to abandon graphite as a reactor moderator during World War II. We first detail the history of both German and American graphite experiments, noting that the Americans faced similar setbacks but succeeded only at the end of a costly 18-month graphite purification program. We then use Monte Carlo N-Particle simulations to reconstruct Bothe's 1941 experiment. We find the thermal absorption cross section of Bothe's Siemens electrographite to be 12.2 mb, in contrast to his reported 7.9 mb. This discrepancy arises because the neutrons in Bothe's experiment did not reach thermal equilibrium, leading to an underestimation of neutron absorption. Additionally, despite misconceptions that the Germans were unaware of boron impurities, we share evidence that Wilhelm Hanle accurately measured boron and cadmium impurities in the electrographite. To support our findings, we provide 9 excerpted and 3 complete English translations of classified wartime reports by Heisenberg, Joos, Bothe, Jensen, Höcker, Hanle, and Kremer. Our work aims to illuminate the rational constraints behind Germany's decision to forgo graphite moderation.

Park, Patrick J.↗

Effect of a reduction in blade thickness on performance of a single stage 20.32 centimeter mean diameter turbine

As part of a program to reduce the manufacturing costs of a small gas-turbine engine, the turbine blading was reduced in thickness to facilitate coining. Tests were made to determine the effect of this modification on turbine performance. The working fluid was air at nominal inlet total conditions of 535 deg F and 20.0 psia. Performance results are presented and compared for four stator-rotor combinations in terms of equivalent torque, mass flow, and efficiency at equivalent design speed and at inlet-total to exit-static pressure ratios of 1.8 to 3.8

Nusbaum, W. J.↗

Study and development of a cryogenic heat exchanger for life support systems

A prototype cryogenic heat exchanger for removal of waste heat from a spacecraft environmental control life support system was developed. The heat exchanger uses the heat sink capabilities of the cryogenic propellants and, hence, can operate over all mission phases from prelaunch to orbit, to post landing, with quiescent periods during orbit. A survey of candidate warm fluids resulted in the selection of E-2, a fluorocarbon compound, because of its low freezing point and high boiling point. The final design and testing of the heat exchanger was carried out, however, using Freon-21, which is similar to E-2 except for its low boiling point. This change was motivated by the desire for cost effectiveness of the experimental program. The transient performance of the heat exchanger was demonstrated by an analog simulation of the heat sink system. Under the realistic transient heat load conditions (20 sec ramp from minimum to maximum Freon-21 inlet temperature), the control system was able to maintain the warm fluid outlet temperature within + or - 3 F. For a 20-sec ramp from 0 F to -400 F in the hydrogen inlet temperature, at maximum heat load, the warm fluid outlet temperature was maintained within + or - 7 F.

Soliman, M. M.↗