Identification of volatile contaminants of space cabin materials Technical report, Nov. 1965 - Feb. 1967
Volatile contaminants of space cabin materials
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Volatile contaminants of space cabin materials
Spacecraft sterilization standards and microbial contamination of Mars
Russian and American practices and policies regarding planetary contamination in connection with COSPAR requirements
NASA and USAF experiment on mans contribution to trace contaminants in space cabin simulator at 760 mm of Hg
Metallic couples ultrahigh vacuum adhesion experiments show contaminant dispersal as major barrier
Contaminant concentration due to human habitation of space cabin simulator at 258 mm Hg and oxygen atmosphere environment
Experiments were conducted in a Mars simulation chamber (MSC) to characterize the survival of endospores of Bacillus subtilis under high UV irradiation and simulated martian conditions. The MSC was used to create Mars surface environments in which pressure (8.5 mb), temperature (-80, -40, -10, or +23 degrees C), gas composition (Earth-normal N2/O2 mix, pure N2, pure CO2, or a Mars gas mix), and UV-VIS-NIR fluence rates (200-1200 nm) were maintained within tight limits. The Mars gas mix was composed of CO2 (95.3%), N2 (2.7%), Ar (1.7%), O2 (0.2%), and water vapor (0.03%). Experiments were conducted to measure the effects of pressure, gas composition, and temperature alone or in combination with Mars-normal UV-VIS-NIR light environments. Endospores of B. subtilis, were deposited on aluminum coupons as monolayers in which the average density applied to coupons was 2.47 x 10(6) bacteria per sample. Populations of B. subtilis placed on aluminum coupons and subjected to an Earth-normal temperature (23 degrees C), pressure (1013 mb), and gas mix (normal N2/O2 ratio) but illuminated with a Mars-normal UV-VIS-NIR spectrum were reduced by over 99.9% after 30 sec exposure to Mars-normal UV fluence rates. However, it required at least 15 min of Mars-normal UV exposure to reduce bacterial populations on aluminum coupons to non-recoverable levels. These results were duplicated when bacteria were exposed to Mars-normal environments of temperature (-10 degrees C), pressure (8.5 mb), gas composition (pure CO2), and UV fluence rates. In other experiments, results indicated that the gas composition of the atmosphere and the temperature of the bacterial monolayers at the time of Mars UV exposure had no effects on the survival of bacterial endospores. But Mars-normal pressures (8.5 mb) were found to reduce survival by approximately 20-35% compared to Earth-normal pressures (1013 mb). The primary implications of these results are (a) that greater than 99.9% of bacterial populations on sun-exposed surfaces of spacecraft are likely to be inactivated within a few tens of seconds to a few minutes on the surface of Mars, and (b) that within a single Mars day under clear-sky conditions bacterial populations on sun-exposed surfaces of spacecraft will be sterilized. Furthermore, these results suggest that the high UV fluence rates on the martian surface can be an important resource in minimizing the forward contamination of Mars. c2003 Elsevier Inc. All rights reserved.
Experiments were performed to quantify the effect of contamination in the helium working gas of a typical pulse tube cryocooler operating at 60 K with 1 W of applied heating load.
The Triana observatory was built at NASA GSFC in the late 1990's, then placed into storage. After approximately ten years it was removed from storage and repurposed as the Deep Space Climate Observatory (DSCOVR). This presentation outlines the contamination control program lessons learned during the integration, test and launch of DSCOVR.
In membrane-aerated biofilm reactors (MABRs), hollow fibers are used to supply oxygen to the biofilms and bulk fluid. A pressure and concentration gradient between the inner volume of the fibers and the reactor reservoir drives oxygen mass transport across the fibers toward the bulk solution, providing the fiber-adhered biofilm with oxygen. Conversely, bacterial metabolic gases from the bulk liquid, as well as from the biofilm, move opposite to the flow of oxygen, entering the hollow fiber and out of the reactor. Metabolic gases are excellent indicators of biofilm vitality, and can aid in microbial identification. Certain gases can be indicative of system perturbations and control anomalies, or potentially unwanted biological processes occurring within the reactor. In confined environments, such as those found during spaceflight, it is important to understand what compounds are being stripped from the reactor and potentially released into the crew cabin to determine the appropriateness or the requirement for additional mitigation factors. Reactor effluent gas analysis focused on samples provided from Kennedy Space Center's sub-scale MABRs, as well as Johnson Space Center's full-scale MABRs, using infrared spectroscopy and gas chromatography techniques. Process gases, such as carbon dioxide, oxygen, nitrogen, nitrogen dioxide, and nitrous oxide, were quantified to monitor reactor operations. Solid Phase Microextraction (SPME) GC-MS analysis was used to identify trace volatile compounds. Compounds of interest were subsequently quantified. Reactor supply air was examined to establish target compound baseline concentrations. Concentration levels were compared to average ISS concentration values and/or Spacecraft Maximum Allowable Concentration (SMAC) levels where appropriate. Based on a review of to-date results, current trace contaminant control systems (TCCS) currently on board the ISS should be able to handle the added load from bioreactor systems without the need for secondary mitigation.
The current trace-contaminant (TC) removal technology for use in Extravehicular Activities (EVAs) involves the use of a packed bed of acid-impregnated granular charcoal, which is difficult to regenerate. In this paper, results are presented on the development of vacuum-regenerable TC sorbents for use in the Portable Life Support System (PLSS). The sorbents are derived from 3D-printed polymer monoliths (e.g., honeycomb structures), which are then carbonized and activated in order to develop porosity, and also to enhance the TC-sorption capacity. Results are presented on the following aspects of carbon-sorbent development: (1) precursor selection; (2) monolith fabrication; (3) shape retention and strength; (4) carbon surface and porosity characterization; (5) TC-sorption capacity and vacuum-regeneration; (6) pressure drop; and (7) sub-scale sorbent prototype. The use of predominantly microporous monolithic carbon is associated with the following benefits: (a) high TC-sorption capacity; (b) low pressure drop; (c) rapid vacuum (pressure-swing) desorption due to thin monolith walls and low pressure drop; (d) good thermal management (high thermal conductivity and low adsorption/desorption thermal effects associated with physisorption); and (e) good resistance to dusty environments.
Processing of metallic melts in microgravity containerless experiments requires control of contaminants like oxygen and water vapor to below parts-per-billion (ppb) levels.
Results are presented from pulse tube experiments designed to investigate the effect of 400 parts per million water vapour contamination of helium working gas.
A miniaturized electronic nose has been constructed at JPL in collaboration with Caltech. This array of conductometric sensors has been trained to detect and qualify the presence of vapors in the air; the compounds detected have been found as contaminants in shuttle air.
The launch of the James Webb Space Telescope (JWST) was successfully performed by Ariane 5 from French Guiana on December 25th 2021. The unique nature of the JWST mission led to various adaptations of the Ariane 5 launch system to fulfill stringent cleanliness and hygrometry requirements all along the launch preparation. JWST integration and test activities in the Final Assembly Building (BAF) had to be performed in ISO Class 7 equivalent conditions under Volatile Organic Compounds (VOC) protection and monitoring. For this purpose, a dedicated air supply system equipped with Airborne Molecular Contamination (AMC) filters was installed in the umbilical mast. The fairing itself was specially sealed to protect the inner environment, and to, guarantee ISO Class 7, the BAF Composite Hall (BAF-HC) facilities were upgraded with a removable “Air Shower Curtain” (AShC) containment enclosure between the mobile platforms around JWST. The preparation of these Ariane 5 launch system adaptations started several years before the launch campaign with close cooperation and coordination between Arianespace, ArianeGroup, the European Space Agency (ESA) and the National Aeronautics and Space Administration (NASA). This paper describes their specificities and addresses the challenges experienced to achieve the successful mission preparation.
The launch of the James Webb Space Telescope (JWST) was successfully performed by Ariane 5 from French Guiana on December 25th 2021. The unique nature of the JWST mission led to various adaptations of the Ariane 5 launch system to fulfill stringent cleanliness and hygrometry requirements all along the launch preparation. JWST integration and test activities in the Final Assembly Building (BAF) had to be performed in ISO Class 7 equivalent conditions under Volatile Organic Compounds (VOC) protection and monitoring. For this purpose, a dedicated air supply system equipped with Airborne Molecular Contamination (AMC) filters was installed in the umbilical mast. The fairing itself was specially sealed to protect the inner environment, and to, guarantee ISO Class 7, the BAF Composite Hall (BAF-HC) facilities were upgraded with a removable “Air Shower Curtain” (AShC) containment enclosure between the mobile platforms around JWST. The preparation of these Ariane 5 launch system adaptations started several years before the launch campaign with close cooperation and coordination between Arianespace, ArianeGroup, the European Space Agency (ESA) and the National Aeronautics and Space Administration (NASA). This paper describes their specificities and addresses the challenges experienced to achieve the successful mission preparation.
Controlling moisture is a critical function performed in the space suit during extra vehicular activity (EVA) missions. Currently, this function is carried out by a sublimator, which is coated with a hydrophilic material. Tests have shown that siloxane compounds can off gas from the helmet absorption pad extension (HAP-E) and helmet absorption band (HAB) when they are at elevated temperatures and initial testing indicated that siloxanes could damage the hydrophilic coating. Therefore, more representative testing was needed. Important test considerations were source and destination kinetics, system geometries, scrubbing efficacy by the activated charcoal from the Metox canister, and other benefits that derive from active condensation occurring on the hydrophilic coating during exposure. A ventilation loop that was originally constructed to test hardware for control of CO2 and trace contaminants under EVA conditions was modified to conduct the siloxane off gassing tests. A vacuum compatible acrylic chamber was installed to simulate the suit volume. A steel beaker located in the chamber contained the HAP-E and HAB materials and was heated with two band heaters. The flow exiting the chamber passed through a LiOH cannister, which contained carbon beds to simulate their function in the Metox. The flow then was directed into a smaller volume that contained a coupon, which was coated with the hydrophilic material and was maintained at 10°C (50°F). Moisture was injected upstream of the suit volume simulator to maintain the dew point between 12.7°C (55°F) and 18.3°C (65°F). The pressure was controlled to between 3.8 and 4.4 psia, and the flow was held at 6 acfm. The system was run for an equivalent of 25 ten-hour EVAs, where the HAP-E/HAB materials were changed out after each EVA. The effect of the potential off gassing on the coupon was measured after each EVA period.
A Self-Contained Oxygen Generator (SCOG) produces breathable oxygen (O 2 ) by using chemically-reactive briquettes that begin producing O 2 when mechanically ignited. Contamination with organic material of, or manufacturing defects in, the briquettes have been shown to lead to conditions that can cause an explosive failure