Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Investigation of the Semicoa SCF9550 and the International Rectifier IRHM57260SE for Single-Event Gate Rapture and Single-Event Burnout : NASA Electronic Parts and Packaging (NEPP) Program Office of Safety and Mission Assurance

Single-event-effect test results for hi-rel total-dose-hardened power MOSFETs are presented in this report. TheSCF9550 from Semicoa and the IRHM57260SE from International Rectifier were tested to NASA test condition/standards and requirements.The IRHM57260SE performed much better when compared to previous testing. These initial results confirm that parts from the Temecula line are marginally comparable to the El Segundo line. The SCF9550 from Semicoa was also tested and represents the initial parts offering from this vendor. Both parts experienced single-event gate rupture (SEGR) and single-event burnout (SEB). All of the SEGR was from gate to drain.

Single Event Gate Rupture↗

An investigation of the dynamic separation of spot welds under plane tensile pulses

We performed ultra-high-speed tests for purely opening spot welds using plane tensile pulses. A gun system generated a parallel impact of a projectile plate onto a welded plate. Induced by the interactions of the release waves, the welded plate opened purely under the plane tensile pulses. We used the laser velocity interferometer system for any reflector to measure the velocity histories of the free surfaces of the free part and the spot weld of the welded plate. We then used a scanning electron microscope to investigate the recovered welded plates. We found that the interfacial failure mode was mainly a brittle fracture and the cracks propagated through the spot nugget, while the partial interfacial failure mode was a mixed fracture comprised ductile fracture and brittle fracture. We used the measured velocity histories to evaluate the tension stresses in the free part and the spot weld of the welded plate by applying the characteristic theory. We also discussed the different constitutive behaviors of the metals under plane shock loading and under uniaxial split Hopkinson pressure bar tests. We then compared the numerically simulated velocity histories of the free surfaces of the free part and the spot weld of the welded plate with the measured results. The numerical simulations made use of the fracture stress criteria, and then the computed fracture modes of the tests were compared with the recovered results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical properties of several nickel alloys in hydrogen at elevated temperatures

Tests were performed to determine low cycle fatigue and crack growth rate properties of one iron-base and two forms of one cast nickel-base alloy. The alloys were tested in various forms and/or heat-treat conditions that are proposed for use in a high-pressure hydrogen or a hydrogen-water vapor environment. Some general conclusions can be made comparing the results of tests in a hydrogen environment with those in a hydrogen-water vapor environment. The hydrogen-water vapor environment caused a 50 percent average reduction in fatigue life, indicating extreme degradation when compared with tests conducted in air, for Incoloy 903 at 1033 K (1400 F). Crack growth rates increased significantly for all materials with increasing test temperature. A very significant increase (three orders of magnitude) in crack growth rate occurred for Incoloy 903 tested in the hydrogen-water vapor environment when compared with testing done in hydrogen along at 922 K (1200 F).

Warren, J. R.↗

Evaluation of bifacial module technologies with combined–accelerated stress testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. Furthermore, this is attributed to previous X-ray topography and modeling work showing higher stress in cells and interconnections in glass-glass modules than glass-backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. We found light-induced degradation (LID) in module types with regenerated (inactive) cells with C-AST, suggesting the possibility of LID destabilization in some field conditions. We could also distinguish potential-induced degradation (PID) on the back of the bifacial passivated emitter and rear cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass-glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while –1200 V system voltage is applied in C-AST, supporting the conclusion that this module type with glass-glass construction would be susceptible to PID in the field.

14 SOLAR ENERGY↗

Learning an Algebriac Multrigrid Interpolation Operator Using a Modified GraphNet Architecture

This work, building on previous efforts, develops a suite of new graph neural network machine learning architectures that generate data-driven prolongators for use in Algebraic Multigrid (AMG). Algebraic Multigrid is a powerful and common technique for solving large, sparse linear systems. Its effectiveness is problem dependent and heavily depends on the choice of the prolongation operator, which interpolates the coarse mesh results onto a finer mesh. Previous work has used recent developments in graph neural networks to learn a prolongation operator from a given coefficient matrix. In this paper, we expand on previous work by exploring architectural enhancements of graph neural networks. A new method for generating a training set is developed which more closely aligns to the test set. Asymptotic error reduction factors are compared on a test suite of 3-dimensional Poisson problems with varying degrees of element stretching. Results show modest improvements in asymptotic error factor over both commonly chosen baselines and learning methods from previous work.

97 MATHEMATICS AND COMPUTING↗

Viking configuration pitch damping derivatives as influenced by support interference and test technique at transonic and supersonic speeds.

Experimental studies to determine the 140-deg spherically-blunted cone configuration single degree-of-freedom damping derivative included model sting interference effects at M = 1.76 to 3.0. Minimal sting influences are noted with sting/model diameter ratios of 0.183 and effective sting lengths of 3.55 of the reference length. Increasing the ratio of sting diameter to reference length to 0.53 influences damping considerably at angles of attack from 0 to 3 deg at all Reynolds numbers but shows little or no effect at higher angles. Free-flight model wake geometries (wake neck position and size) correlate well with those from captive model tests with the small diameter sting; this adds confidence to obtaining damping derivatives through captive model testing. The damping characteristics of an early Viking configuration obtained on 11.23 and 4.35% scale models using forced and free oscillation test methods, respectively, in two different test facilities are compared. The agreement is quite good under test conditions.

Steinberg, S.↗

Flight-measured X-24A lifting body control surface hinge moments and correlation with wind tunnel predictions

Control-surface hinge-moment measurements obtained in the X-24A lifting body flight-test program are compared with results from wind-tunnel tests. The effects of variations in angle of attack, angle of sideslip, rudder bias, rudder deflection, upper-flap deflection, lower-flap deflection, Mach number, and rocket-engine operation on the control-surface hinge moments are presented. In-flight motion pictures of tufts attached to the inboard side of the right fin and the rudder and upper-flap surfaces are discussed.

Tang, M. H.↗

Advancement of proprotor technology. Task 2: Wind-tunnel test results

An advanced-design 25-foot-diameter flightworthy proprotor was tested in the NASA-Ames Large-Scale Wind Tunnel. These tests, have verified and confirmed the theory and design solutions developed as part of the Army Composite Aircraft Program. This report presents the test results and compares them with theoretical predictions. During performance tests, the results met or exceeded predictions. Hover thrust 15 percent greater than the predicted maximum was measured. In airplane mode, propulsive efficiencies (some of which exceeded 90 percent) agreed with theory.

Source record↗

Characterization, performance, and prediction of a lead-acid battery under simulated electric vehicle driving requirements

A state-of-the-art 6-V battery module in current use by the electric vehicle industry was tested at the NASA Lewis Research Center to determine its performance characteristics under the SAE J227a driving schedules B, C, and D. The primary objective of the tests was to determine the effects of periods of recuperation and long and short periods of electrical regeneration in improving the performance of the battery module and hence extendng the vehicle range. A secondary objective was to formulate a computer program that would predict the performance of this battery module for the above driving schedules. The results show excellent correlation between the laboratory tests and predicted results. The predicted performance compared with laboratory tests was within +2.4 to -3.7 percent for the D schedule, +0.5 to -7.1 percent for the C schedule, and better than -11.4 percent for the B schedule.

Ewashinka, J. G.↗

Failure characteristics of graphite-epoxy structural components loaded in compression

Failure characteristics of compressively loaded graphite-epoxy components are described. Experimental results for both strength-critical laminates and structural components with postbuckling strength are presented. Effects of low speed impact damage and circular holes on compressive strength are discussed. Delamination and shear crippling failure mechanisms that limit the performance of strength-critical laminates are described. Transverse shear and skin-stiffener separation failure mechanisms that limit the performance of components with postbuckling strength are also described. The influence of matrix properties on compressive strength improvements for impact damaged laminates is discussed. Experimental data and results from a failure analysis for strength-critical laminates with cutouts are discussed and compared with impact damage results. Typical postbuckling test results are compared with analytical predictions.

Starnes, J. H., Jr.↗

Failure characteristics of graphite-epoxy structural components loaded in compression

Failure characteristics of compressively loaded graphite-epoxy components are described. Experimental results for both strength-critical laminates and structural components with postbuckling strength are presented. Effects of low speed impact damage and circular holes on compressive strength are discussed. Delamination and shear crippling failure mechanisms that limit the performance of strength-critical laminates are described. Transverse shear and skin-stiffener separation failure mechanisms that limit the performance of components with postbuckling strength are also described. The influence of matrix properties on compressive strength improvements for impact damaged laminates is discussed. Experimental data and results from a failure analysis for strength-critical laminates with cutouts are discussed and compared with impact damage results. Typical postbuckling test results are compared with analytical predictions. Previously announced in STAR as N83-12174

Starnes, J. H., Jr.↗

Friction and Wear Characteristics of a Modified Composite Solid Lubricant Plasma Spray Coating

LCR304 is a solid lubricant coating composed of Ni-10Cr, Cr2O3, BaF2-CaF2 and Ag and developed for dimensional stability in high temperature air. This coating is a modification of PS304, which differs in that the Ni-Cr constituent contains 20wt% Cr. The tribological characteristics of LCR304 were evaluated by pin-on-disk and foil air bearing rig testing from 25 to 650 C and compared to previous test results with PS304. For both tests, the friction coefficient decreased as temperature increased from 25 to 650 C. Wear generally decreased with increasing temperature for all pin-on-disk tests. LCR304 coated components produced the least wear of Inconel X-750 counterface materials at 427 and 650 C. These results indicate that the LCR304 coating has potential as a replacement for PS304 in, for example, low cycle (minimum wear) applications where dimensional stability is imperative.

Stanford, M. K.↗

Arcing in Leo and Geo Simulated Environments: Comparative Analysis

Comprehensive tests of two solar array samples in simulated Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) environments have demonstrated that the arc inception voltage was 2-3 times lower in the LEO plasma than in the GEO vacuum. Arc current pulse wave forms are also essentially different in these environments. Moreover, the wide variations of pulse forms do not allow introducing the definition of a "standard arc wave form" even in GEO conditions. Visual inspection of the samples after testing in a GEO environment revealed considerable damage on coverglass surfaces and interconnects. These harmful consequences can be explained by the discharge energy being one order of magnitude higher in vacuum than in background plasma. The tests also revealed a potential danger of powerful electrostatic discharges that could be initiated on the solar array surface of a satellite in GEO during the ignition of an arcjet thruster.

Vayner, Boris V.↗

NASA ACC High Energy Dynamic Impact Methodology and Outcomes

High fidelity analysis methods known as Progressive Damage Analysis (PDA) methods, capable of reliably predicting the onset and progression of damage in composite materials, are being developed for HEDI event simulation. Four state-of-the-art PDA methods are being investigated: LS-DYNA MAT162, LS-DYNA MAT261, Smooth-Particle Galerkin (SPG), and EMU Peridynamics. Validation of these PDA models aims to follow a building block approach, starting with coupon- and component-level development. As part of the overall effort, material characterization testing was performed to bridge gaps between existing experimental data and the material property inputs required to predict ballistic impact behavior at the component-level. The material models were updated with the results of the coupon-level testing and were then used to predict panel behavior and damage in ballistic impact events. To assess the accuracy of the PDA methods, these pre-test predictions were compared to the results of ballistic impact testing.

Hunziker, Kenneth J.↗

Characterizing Face Sheet/Core Disbonding Using the Single Cantilever Beam Test: Results from an International Round Robin

Test results from an international round robin are presented. The single cantilever beam (SCB) test was used to characterize face sheet/core disbonding in sandwich components in an effort to help standardization. Each of the seven participating laboratories performed a set of five baseline tests using the same protocol, however, using their own specific equipment. In addition, each laboratory performed two sets of tests with altered tests conditions which included using a test fixture with a translating carriage and performing the tests with different loading and unloading speeds. The orientation of the disbond front with respect to the honeycomb core cells was varied and the effect on the fracture toughness was also studied. Additional factors that could influence test results were investigated, such as the use of a saw cut starter disbond as an alternative to Teflon® release film, and the effects of using a face sheet doubler to increase the bending stiffness. For each set of tests, summary results such as load/displacements plots, observed disbond growth location and calculated energy release rates are reported and a comparison of results between labs is presented. Critical strain energy release rate measurements from SCB tests are also compared with measurements made from an alternative test, namely the double cantilever beam with uneven bending moments (DCB-UBM) test, which has been studied extensively at the Technical University of Denmark and proposed as a mixed-mode test standard. A set of recommendations are made with respect to improving the SCB test and a path to standardization is presented.

Ronald Krueger↗

Evaluation of Bifacial Modules and PV Technologies with Combined-Accelerated Stress Testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. This is attributed to previous x-ray topography work showing higher stress in cells in glass-glass modules than glass backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. Finally, among multiple cell degradation modes that we observed such as light-induced degradation (LID), we differentiated susceptibility to potential-induced degradation (PID) on the back of the bifacial Passivated Emitter Back Cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass/glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while -1200 V system voltage is applied in C-AST, supporting the conclusion that this module type would be susceptible to PID in the field.

bifacial modules↗

Vibration analysis of the Long Duration Exposure Facility (LDEF) using SPAR

The structural modeling of the Long Duration Exposure Facility (LDEF) utilizing the SPAR system of computer programs for vibration analysis is discussed. The technical areas of interest were: (1) development of the LDEF finite element model; (2) derivation of tray effective panel stiffness matrix using finite element tray models; (3) assessment of attachment conditions and end fitting flexibility by comparing SPAR with test static displacements; (4) SPAR grouping; and (5) derivation of the LDEF frequencies and mode shapes and comparing them with tests. Special detailed finite element modeling was required to obtain good agreement between analytical and test vibration modes. An orthotropic panel in the overall model was developed. Orthotropic stiffness for this panel were obtained from finely detailed statically loaded SPAR models which included stiffness and allowed for partial relative sliding of the tray clamping attachments. Sensitivity to LDEF joint boundary conditions was determined, and static test data proved valuable in assessing modeling of local end fittings.

Edighoffer, H.↗

Nodal Modeling of Tank Pressurization and Draining using a Multi-Node-Ullage Approach

The purpose of the pressurization system in liquid rocket propulsion is to control the pressure in the gas space of the propellant tank (known as the ullage space) and the propellant mass flowrate to the engine. A mathematical model is required to predict the amount of pressurant necessary to ensure that pressure and temperature levels inside the tank remain within acceptable limits and that the propellant pressure leaving the tank satisfies the net positive suction pressure (NPSP) requirement of the pump feeding the engine. Nodal codes typically model tank pressurization and draining using a single node to represent the ullage and a single node to represent the propellant. As the tank drains, the ullage node grows and the propellant node shrinks. The heat transfer between ullage to wall and ullage to propellant is governed by natural convection. Designers of liquid propulsion systems often use empirical correlations to estimate the “Collapse Factor” which represents the ratio of pressurant required with heat transfer and the amount of pressurant required without heat transfer. A single node ullage model of tank pressurization was developed using GFSSP to compute the collapse factor reasonably well and later was used to model tank pressurization during test firing of the FASTRAC rocket engine. The predicted tank pressure compared well with the test data. In the early 1970’s, pressurization and drain tests with liquid methane were performed at NASA Lewis Research Center in a vacuum chamber. A 5 ft diameter spherical aluminum tank was tested to drain from 95% to 5% full using gaseous helium, hydrogen, nitrogen and methane as pressurant. Tests were conducted with different pressurant inlet temperatures and drain times. Measured data include pressurant requirement, amount of pressurant condensed, and ullage and wall temperatures at various heights in the ullage space at the end of draining. A single node GFSSP model was developed to simulate helium pressurization of the methane tank. Predicted helium consumption was 8-23% less than measured. The average error of the six test cases was 16%. A single ullage node with multiple solid node model was developed using Thermal Desktop. Predicted helium consumption compares with the test data within 2%. This paper describes the development of a GFSSP multi-node ullage model of the test configuration and compares the predicted pressurant consumption for both helium and autogenous pressurization using gaseous methane with experimental as well as TD predictions.

Nodal Model↗