Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

High-gradient two-beam electron accelerator

The main goal for this project was to design, build, and evaluate a detuned-cavity, collinear, two-beam accelerator structure. Testing was to be at the Yale University Beam Physics Laboratory, under terms of a sub-grant from Omega-P to Yale. Facilities available at Yale for this project include a 6-MeV S-band RF gun and associated beam line for forming and transporting a ~1 A drive beam , a 300 kV beam source for use as a test beam, and a full panoply of laboratory infrastructure and test equipment. During the first year of this project, availability and functionality of the 6-MeV drive beam and 300 kV test beam were confirmed, and the beam line was restored to a layout to be used with the two-beam accelerator project. Major efforts during the first year were also focused on computational design and simulation of the accelerator structure itself, on beam dynamics, and on beam transport. Effort during the second year was focussed on building and preparing to test the structure, including extensive cold testing. Detailed results from work under this project have been published in twelve archival journal articles, listed in Section IV of the technical report.

43 PARTICLE ACCELERATORS↗

HEAVY ION FUSION SCIENCE VIRTUALNATIONAL LABORATORY 2nd QUARTER 2009 MILESTONE REPORT: Perform beam and target experiments with a new induction bunching module, extended FEPS plasma, and improved target diagnostic and positioning equipment on NDCX

This effort contains two main components: The new induction-bunching module is expected to deliver higher fluence in the bunched beam, and the new target positioner will enable a significantly enhanced target physics repetition rate. The velocity ramp that bunches the K{sup +} beam in the neutralized drift compression section is established with a bipolar voltage ramp applied to an acceleration gap. An induction acceleration module creates this voltage waveform. The new bunching module (IBM) specially built for NDCX has approximately twice the capability (volt-seconds) as our original IBM. We reported on the beam line design for the best use of the bunching module in our FY08 Q2 report. Based on simulations and theoretical work, we chose to extend the drift compression section and use the additional volt-seconds to extend the pulse duration and keep the peak voltage swing (and velocity excursions) similar to the present module. Simulations showed that this approach, which extends the drift section, to be advantageous because it limits the chromatic aberrations in the beam spot on target. To this end, colleagues at PPPL have fabricated the meter-long extension to the ferroelectric plasma source and it was installed on the beam line with the new IBM in January 2009. Simulation results suggest a factor of two increase in energy deposition from the bunched beam. In the first WDM target run (August-November 2008) the target handling setup required opening the vacuum system to manually replace the target after each shot (which destroys the target). Because of the requirement for careful alignment of each individual target, the target shot repetition rate was no greater than 1 shot per day. Initial results of this run are reported in our FY08 4th Quarter Milestone Report. Based on the valuable experience gained in the initial run, we have designed and installed an improved target alignment and positioning system with the capability to reposition targets remotely. This capability allows us to significantly increase our shot repetition rate, and to take greater advantage of the pinhole/cone arrangement we have developed to localize the beam at final focus. In addition we have improved the capability of the optical diagnostic systems, and we have installed a new beam current transformer downstream of the target to monitor beam current transmitted through the target during an experiment. These improvements will allow us to better exploit the inherent capability of the NDCX facility for high repetition rate and thus to provide more detailed experimental data to assess WDM physics models of target behavior. This milestone has been met by demonstrating highly compressed beams with the new bunching module, which are neutralized in the longer drift compression section by the new ferro-electric plasma sources. The peak uncompressed beam intensity ({approx}600 kW/cm{sup 2}) is higher than in previous measurements, and the bunched beam current profiles are {approx}2ns. We have also demonstrated a large increase in the experimental data acquisition rate for target heating experiments. In the first test of the new remote-controlled target positioning system, we completed three successful target physics shots in less than two hours. Further improvements are expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power Density Distributions in Electron Beams

Measuring and controlling the power density distribution of electron beams used for welding is critical for producing repeatable welds and for transferring welding parameters between different machines. On any given machine, the power density distribution is controlled by defocusing the beam relative to its sharpest focused condition. However, measuring the power density distribution can be difficult due to the intense nature of welding beams and is further complicated by imperfect electron optics that can distort the beam, making it difficult to quantify. The enhanced modified Faraday cup (EMFC) diagnostic method was used here for beam analysis that utilizes computed tomography to reconstruct the beam’s power density distribution. These results were compared to the International Standards Organization (ISO) method for characterizing laser beams using a second-moment D4σ calculation. For ideal Gaussian-shaped beams, both methods would give the same result. However, for imperfect beams, the calculated D4σ diameter was shown to be about 25% larger relative to the FWe2 diameter measured by the EMFC due to the heavier weighting of data in the tails of the beam by D4σ. Finally, although both methods produce repeatable welds, it is important to understand the differences in the reported beam diameters, divergence angles, and beam parameter products when transferring parameters between machines.

36 MATERIALS SCIENCE↗

Measurement and Simulation of Interpenetration and DC Accumulation of Beam in the University of Maryland Electron Ring

The University of Maryland Electron Ring (UMER) is a facility to study the long-path length physics of a highly space-charge dominated beam. Optimizing the ring characteristics to maximize beam lifetime has required an understanding of both the longitudinal and transverse dynamics of the beam and how they are coupled. A combination of experimental and numerical evidence is presented to show that front end of the injected bunch is accelerated by longitudinal space charge forces while the back of the same bunch is similarly decelerated leading to a longitudinal expansion of the injected bunch. This continues until the head overtakes the tail of the preceding turn. A significant portion of the apparent beam current decay is actually due to the merging of the head and tail, which results in a difficult-to-measure DC component of the beam. We also present a novel measurement technique to examine this longitudinal behavior that uses a voltage pulse applied between the horizontal plates at a beam position monitor. The pulse amplitude is sufficient to deflect the beam so that it intercepts the chamber wall. The resulting notch in the beam current, which can be varied in time, allows reconstruction of the DC component. Combined with simulations of the longitudinal and transverse beam characteristics this procedure provides data that can be used to understand the underlying beam dynamics.

43 PARTICLE ACCELERATORS↗

Optimization of LANSCE proton beam performance for isotope production

The LANSCE Isotope Production Facility (IPF) utilizes a 100-MeV proton beam with average power of 23 kW for isotope production in the fields of medicine, nuclear physics, national security, environmental science and industry. Typical tolerable fractional beam loss in the 100-MeV beamline is 4 x 10 -3 . Experimental beam study was made to minimize the beam losses. Adjustments to the ion source’s extraction voltage resulted in the removal of tails in phase space. Beam based steering in beamlines led to the reduction of beam emittance growth. Readjustment of the 100-MeV quadrupole transport resulted in the elimination of excessive beam envelope oscillations and removed significant parts of the beam halo at the target. Careful beam matching in the drift tube linac (DTL) provided high beam capture (75%) in the DTL. Finally, after improvements, beam losses in the 100-MeV beamline were reduced by an order of magnitude and reached the fractional level of 5 x 10 -4 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-dependent imaging of space-charge dominated electron beams

When considered as non-neutral plasmas, space-charge dominated charged particle beams have significantly smaller Debye lengths than their beam sizes. Therefore, collective effects due to space-charge forces are very important to the beam dynamics. As an example, density perturbations generated in a space-charge dominated charge particle beam will stimulate longitudinally space-charge waves. To study the modification of transverse beam distributions by longitudinal beam dynamics, experimental studies of low-energy electron beams, with and without longitudinal density perturbations, have been undertaken at the University of Maryland's electron ring and the Long Solenoid Experiment (LSE). We have taken time-resolved beam images on these machines using two different diagnostics: Optical transition radiation, produced from an intercepting aluminized silicon screen, and a fast (<3 ns decay time) phosphor screen. Results from both techniques show that both the transverse size and transverse particle distribution of a space-charge dominated beam are affected by the longitudinal dynamics of the beam. In addition to the fast imaging measurements, longitudinal mean energy profiles of different beams have also been measured at different locations in the LSE system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collective effects on the wakefield and stopping power of an ion beam pulse in plasmas

A two-dimensional (2D) particle-in-cell simulation is carried out to study the collective effects on the wakefield and stopping power for a hydrogen ion beam pulse propagation in hydrogen plasmas. The dependence of collective effects on the beam velocity and density is obtained and discussed. For the beam velocity, it is found that the collective effects have the strongest impact on the wakefield as well as the stopping power in the case of the intermediate beam velocities, in which the stopping power is also the largest. For the beam density, it is found that at low beam densities, the collective contribution to the stopping power increase linearly with the increase of the beam density, which corresponds well to the results calculated using the dielectric theory. However, at high beam densities, our results show that after reaching a maximum value, the collective contribution to the stopping power starts to decrease significantly with the increase of the beam density. Besides, at high beam densities, the wakefield loses typical V-shaped cone structures, and the wavelength of the oscillation wakefield increases as the beam density increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy

Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA Monte Carlo code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per monitor unit using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured full width at half maximum (FWHM) of the pencil beam in air at the isocenter was energy-dependent for both particle species: in particular, for protons, the spot size ranged from 0.7 to 2.2 cm. For carbon ions, two sets of spot size are available: FWHM ranged from 0.4 to 0.8 cm (for the smaller spot size) and from 0.8 to 1.1 cm (for the larger one). The spot position was accurate to within ±1 mm over the whole 20 × 20 cm{sup 2} scan field; homogeneity in a uniform squared field was within ±5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements performed during a 24-month period show very stable beam characteristics, which are therefore suitable for performing safe and accurate patient treatments.

60 APPLIED LIFE SCIENCES↗

BEAM CONTAINMENT SYSTEM FOR NSLS-II

The shielding design for the NSLS-II will provide adequate protection for the full injected beam loss in two periods of the ring around the injection point, but the remainder of the ring is shielded for lower losses of {le} 10% full beam. This will require a system to insure that beam losses don't exceed these levels for a period of time that could cause excessive radiation levels outside the shield walls. This beam containment system will measure, provide a level of control and alarm indication of the beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators that will provide limits to (and potentially to measure) the beam miss-steering and control the loss points of the charge and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications. This will require some new ideas in beam loss detection capability and collimation. The initial planning and R&D program will be presented.

43 PARTICLE ACCELERATORS↗

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques↗

Influence of alkali-silica reaction on the shear capacity of reinforced concrete beams with minimum transverse reinforcement

A growing number of critical concrete infrastructure are affected by alkali-silica reaction (ASR) damage such as the Seabrook Nuclear Power Plant in New Hampshire, Parker arch-gravity dam in Arizona, and several highway bridges in California and Texas. ASR causes expansion and cracking and degrades the concrete mechanical properties. Despite a wealth of material level studies there is still limited large-scale experimental data regarding the effects of ASR on reinforced concrete (RC) members. Due to the brittle nature of the shear failure in RC structures, this study focuses on the shear response of full-scale ASR damaged RC beams with minimum shear reinforcement. Six RC beams were built with different levels of ASR susceptibility and conditioned in different environments during which continuous expansion monitoring was performed. The beams all contained reactive fine aggregate (sand) and two of them had additional alkali, 1.25% by weight of cement, to accelerate ASR. The highest expansion rate of the beams happened during the first 150 days and the expansions stayed constant after 240 days and 330 days for beams conditioned in outdoor and laboratory conditions, respectively, until the last measurement at 575 days. The highest expansion, 0.4%, was seen in the beams with additional alkali and conditioned outside with regular water spray. Out of the six beams, three were selected at different levels of ASR damage and two shear tests were performed on the minimally reinforced spans close to the ends of each beam. Results indicated that beams gain shear strength from ongoing cement hydration in the presence of moisture for ASR expansions less than 0.2%. Compared to one of the beams with 0.2% ASR expansion, one of the other samples with 0.4% expansion lost 6% of its shear strength, 25% of its shear stiffness, and showed about two times larger shear cracks and shear deformations at peak load. Finally, the shear reinforcement yielded at 20% less load in the beam with 0.4% expansion compared to the beam with 0.2% expansion.

42 ENGINEERING↗

Six-dimensional matching of intense beam with linear accelerating structure

Beam matching is a common technique that is routinely employed in accelerator design with the aim of minimizing beam losses and preservation of beam brightness. Despite being widely used, a full theoretical understanding of beam matching in 6D remains elusive. In this work, we present an analytical treatment of 6D beam matching of a high-intensity beam onto an RF structure. We begin our analysis within the framework of a linear model, and apply the averaging method to a set of 3D beam envelope equations. Accordingly, we obtain a matched solution that is comprised of smoothed envelopes and periodic terms, describing envelope oscillations with the period of the focusing structure. We then consider the nonlinear regime, where the beam size is comparable with the separatrix size. Stating with a Hamiltonian analysis in 6D phase space, we attain a self-consistent beam profile and show that it is significantly different from the commonly used ellipsoidal shape. Subsequently, we analyze the special case of an equilibrium with equal space charge depression between all degrees of freedom. Comparison of beam dynamics for equipartitioned, equal space charge depression, and equal emittances beams is given. Finally, we present experimental results on beam matching in the LANSCE linac.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase control with two-beam interferometry method in a terahertz dielectric wakefield accelerator

High-gradient, beam-driven wakefield acceleration in THz structures is a promising technology for future free electron lasers and colliders. In this scheme, the main beam is accelerated by the wakefield of the high current drive beam. The time separation between the main and drive beams has to be chosen carefully to ensure that the main beam is in an accelerating phase of the drive's wakefield. THz accelerating structures provide high gradient acceleration due to their small apertures, but their phase control is difficult due to the picosecond-scale period. Here, we report on a wakefield acceleration experiment in a 460 GHz dielectric wakefield accelerator (DWA). The optimum phase of the main beam during the experiment is determined with a two-beam wakefield interferometry (TBI) measurement. This is performed without the measurement of the main and drive beam bunch lengths or their separation. In TBI, the interference of the wakefields produced by the drive and main beams is measured with an integrating THz detector. The TBI signal, as a function of separation between the drive and main beams, exhibits a minimum due to destructive interference of these wakefields, which corresponds to maximum acceleration of the main beam as is confirmed by the energy spectrometer measurement. The maximum energy gain of 0.8 MeV and maximum energy loss of 1.2 MeV for the main beam have been measured, which agrees well with theoretical predictions. Published by AIP Publishing.

43 PARTICLE ACCELERATORS↗

Testing the DIII-D co/counter off-axis neutral beam injected power and ability to balance injected torque

DIII-D has undergone a major upgrade and successfully injected high power off-axis neutral beams (~4 MW) in both co-current and counter-current directions. This capability of high power co/counter steerable off-axis neutral beams on a major tokamak opens a unique parameter space of broad pressure and current profiles for high beta steady-state advanced tokamak (AT) scenarios, while retaining the ability to balance the injected torque for low rotation studies. This co/counter off-axis neutral beam capability is being used to validate physics-based energetic particle and thermal transport models for designing next-step facilities based on the steady-state AT approach. This paper reports on the critical evaluation of the transmitted power and energetic ion population produced by this heating and current drive system, which is assessed through visible imaging, neutron measurements and rotation profile measurements at balanced torque. Minimal losses of neutral beam power have been achieved by optimizing the strongly focused ion sources required to pass through the aperture. Tilting of the ion source has been guided by fast visible imaging and resulted in neutral beam injection along the design centerline with empirical characterization of each beam's divergence derived from the imaging data and used in the NUBEAM description of the beam injection. Through exclusive power injection of each neutral beam into MHD quiescent plasmas across a range of neutral beam voltage, perveance and plasma current we conclude that a modest reduction (~10%–15%) of transmitted power compared to on-axis, standard focus has been incurred. We report corrections that more accurately represent the injected power. Good ability to balance the neutral beam torque has been demonstrated by injecting the new off-axis counter injecting beam against the existing off-axis co-injected beam in 2.0 T, 1.0 MA, MHD quiescent L-mode plasmas. Furthermore, the torque balance studies verify the ability to operate with balanced injection, which is critical for achieving low torque and low rotation operation for physics studies and in ITER demonstration discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗

Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams

The aim of this work was to experimentally determine the difference in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to the open and multileaf collimator (MLC) transmitted beam components of intensity modulated radiation therapy (IMRT) beams. EPID dose response curves were measured for open and MLC transmitted (MLC{sub tr}) 10x10 cm{sup 2} beams at central axis and with off axis distance using a shifting field technique. The EPID signal was obtained by replacing the flood-field correction with a pixel sensitivity variation matrix correction. This signal, which includes energy-dependent response, was then compared to ion-chamber measurements. An EPID calibration method to remove the effect of beam energy variations on EPID response was developed for IMRT beams. This method uses the component of open and MLC{sub tr} fluence to an EPID pixel calculated from the MLC delivery file and applies separate radially dependent calibration factors for each component. The calibration procedure does not correct for scatter differences between ion chamber in water measurements and EPID response; these must be accounted for separately with a kernel-based approach or similar method. The EPID response at central axis for the open beam was found to be 1.28{+-}0.03 of the response for the MLC{sub tr} beam, with the ratio increasing to 1.39 at 12.5 cm off axis. The EPID response to MLC{sub tr} radiation did not change with off-axis distance. Filtering the beam with copper plates to reduce the beam energy difference between open and MLC{sub tr} beams was investigated; however, these were not effective at reducing EPID response differences. The change in EPID response for uniform sliding window IMRT beams with MLC{sub tr} dose components from 0.3% to 69% was predicted to within 2.3% using the separate EPID response calibration factors for each dose component. A clinical IMRT image calibrated with this method differed by nearly 30% in high MLC{sub tr} regions from an image calibrated with an open beam calibration factor only. Accounting for the difference in EPID response to open and MLC{sub tr} radiation should improve IMRT dosimetry with a-Si EPIDs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗