Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Hydroxyl Tagging Velocimetry Demonstration in an Augmented Spark Igniter

Hydroxyl tagging velocimetry (HTV) involves tagging a flow by “writing” a line of OH molecules using a laser beam to dissociate H2O molecules and capturing an image of the line after a short delay using laser-induced fluorescence. Velocity is obtained by a time-of-flight analysis of the data. In this effort, HTV was used for obtaining both instantaneous and average velocity profiles in the flow of an augmented spark igniter. Two modes of camera readout were investigated, called conventional full frame mode and dual image mode feature (DIF) mode. In DIF mode, two images are captured in quick succession and therefore the measurement is immune to vibration effects. Measurement uncertainty for the DIF case varied from 3% at the centerline to 10% at the edges of the profile in a 1000-m/s flow. For the full-frame case, measurement uncertainty varied from 3% at the centerline to 7% at the edges. This demonstration provides evidence that the HTV technique is well suited for obtaining velocity profiles in the challenging environment of either a rocket engine or rocket engine igniter.

Augmented Spark Igniter↗

A versatile optical junction using photonic band-gap guidance and self collimation

We show that it is possible to design two photonic crystal (PC) structures such that an optical beam of desired wavelength gets guided within the line defect of the first structure (photonic band gap guidance) and the same beam gets guided in the second structure by self-collimation. Using two dimensional simulation of a design made of the combination of these two structures, we propose an optical junction that allows for crossing of two optical signals of same wavelength and same polarization with very low crosstalk. Moreover, the junction can be operated at number of frequencies in a wide range. Crossing of multiple beams with very low cross talk is also possible. The proposed junction should be important in future integrated photonic circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Apparent sizes and spectral line profiles for spherical ('three-dimensional') astrophysical masers

Calculations are performed for the frequency-dependent transport of radiation in a uniform spherical maser. Coupling between the intensities at different frequencies is treated. Spherical masers are commonly utilized as idealized geometries in which to assess possible deviations (sometimes, 'three-dimensional effects') from the approximation of a linear geometry. We find that the spectral line profile rebroadens in approximately the same manner as that for a linear maser so that the relationship between the line breadth and the luminosity, beaming angle, and degree of saturation is essentially unchanged. The variation of the apparent size of a spherical maser with frequency is not found to be significant at frequencies within the line profile at which the intensity is appreciable. The 'standard approximation' is adequate for obtaining most of the basic properties of spherical masers that have been examined including the relationship between the pumping (or molecular populations) and the intensity of maser radiation. The improved methods employed here are, however, necessary to obtain variation of the apparent size with frequency in the saturated regime. These conclusions differ from those of previous investigators. The calculations here are more reliable than those of previous investigators because these are self-consistent and avoid certain inaccurate simplifications.

Emmering, Robert T.↗

Soft X-ray emission from electron-beam-heated solar flares

Using time-dependent numerical simulations and Solar Maximum Mission observations of a solar flare on 1985 January 23, a study is conducted of the ability of an electron-beam-heating model to reproduce the rise phase of a flare as observed in soft X-ray lines of Ca XIX. The electron beam is parameterized by a peak flux, a low-energy cutoff, and a spectral index, and has a time dependence similar to the observed hard X-ray burst. For a spectral index of 6, only models with a low-energy cutoff of 20 keV reproduce the observed peak emission in the Ca XIX line complex. All models with a low-energy cutoff of 15 keV produce too much emission, while all models with a 25-keV cutoff too little emission. None of the models reproduces the temporal behavior of the soft X-ray emission. The electron-beam-heated component is theorized to only represent a small fraction of the energy released in the impulsive phase of this flare.

Mariska, John T.↗

Development of attenuation and diffraction corrections for linear and nonlinear Rayleigh surface waves radiating from a uniform line source

In recent studies with nonlinear Rayleigh surface waves, harmonic generation measurements have been successfully employed to characterize material damage and microstructural changes, and found to be sensitive to early stages of damage process. A nonlinearity parameter of Rayleigh surface waves was derived and frequently measured to quantify the level of damage. The accurate measurement of the nonlinearity parameter generally requires making corrections for beam diffraction and medium attenuation. These effects are not generally known for nonlinear Rayleigh waves, and therefore not properly considered in most of previous studies. In this paper, the nonlinearity parameter for a Rayleigh surface wave is defined from the plane wave displacement solutions. We explicitly define the attenuation and diffraction corrections for fundamental and second harmonic Rayleigh wave beams radiated from a uniform line source. Attenuation corrections are obtained from the quasilinear theory of plane Rayleigh wave equations. To obtain closed-form expressions for diffraction corrections, multi-Gaussian beam (MGB) models are employed to represent the integral solutions derived from the quasilinear theory of the full two-dimensional wave equation without parabolic approximation. Diffraction corrections are presented for a couple of transmitter-receiver geometries, and the effects of making attenuation and diffraction corrections are examined through the simulation of nonlinearity parameter determination in a solid sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

β-decay spectroscopy of r-process nuclei with N = 126 at KISS

The β-decay properties of nuclei with N = 126, which are believed to act as progenitors in the rapid neutron capture (r-) process path forming the third peak (A ∼ 195) in the observed r-abundance element distribution, are considered critical for understanding the production of heavy elements such as gold and platinum at astrophysical sites. We have constructed the KEK Isotope Separation System (KISS), which consists of a gas cell based laser ion source (atomic number selection) and an isotope separation on-line (ISOL) (mass number selection), to produce pure low-energy beams of neutron-rich isotopes around N = 126 and to study their β-decay properties, which are also of interest for astrophysics. The isotopes of interest will be produced by multi-nucleon transfer reactions in heavy ion collisions (e.g. {sup 136}Xe projectile on {sup 198}Pt target). KISS will allow us to study unknown isotopes produced in weak reaction channels under low background conditions. We successfully extracted the stable {sup 56}Fe beam from KISS at the last commissioning on-line experiment with the extraction efficiency of 0.25% and beam purity of more than 98%. We can access the nuclei with N = 126 and measure their half-lives using the KISS in the case of the extraction efficiency of 0.1%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature dependence of yields from multi-foil SPES target

The temperature dependence of neutron-rich isotope yields was studied within the framework of the HRIBF-SPES Radioactive Ion Beams (RIB) project. On-line release measurements of fission fragments from a uranium carbide target at 1600 C, 1800 C and 2000 C were performed at ORNL (USA). The fission reactions were induced by a 40 MeV proton beam accelerated into a uranium carbide target coupled to a plasma ion source. The experiments allowed for tests of performance of the SPES multi-foil target prototype loaded with seven UC{sub 2}/graphite discs (ratio C/U = 4) with density about 4 g/cm{sup 3}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of the SPS Long Term Orbit Drifts

The Super Proton Synchrotron (SPS) is the last accelerator in the Large Hadron Collider (LHC) injector chain, and has to deliver the two high-intensity 450 GeV proton beams to the LHC. The transport from SPS to LHC is done through the two Transfer Lines (TL), TI2 and TI8, for Beam 1 (B1) and Beam 2 (B2) respectively. During the first LHC operation period Run 1, a long term drift of the SPS orbit was observed, causing changes in the LHC injection due to the resulting changes in the TL trajectories. This translated into longer LHC turnaround because of the necessity to periodically correct the TL trajectories in order to preserve the beam quality at injection into the LHC. Different sources for the SPS orbit drifts have been investigated: each of them can account only partially for the total orbit drift observed. In this paper, the possible sources of such drift are described, together with the simulated and measured effect they cause. Possible solutions and countermeasures are also discussed.

43 PARTICLE ACCELERATORS↗

Beam emission spectroscopy for density turbulence measurements on the MAST spherical tokamak

Beam emission spectroscopy (BES) of the energetic deuterium (D{sup 0}) heating beams can provide a means of characterizing the density turbulence in tokamak plasmas. First such measurements have been performed on the MAST spherical tokamak using a trial BES system, which shares the collection optics of the charge-exchange recombination spectroscopy system. This system, with eight spatial channels covering the outer part of the plasma cross section, uses avalanche photodiode detectors with custom preamplifiers to provide measurements at 1 MHz bandwidth with a spatial resolution of 4 cm. Simulations of the measurement, including the beam absorption and excitation, line-of-sight integration of the emission spectrum, and the characteristics of the detection system have been benchmarked against the measured absolute intensity of the Doppler shifted D{sub {alpha}} fluorescence from the 50 keV beam. This gives confidence in predictions of the performance of a two-dimensional imaging BES system planned for MAST. Correlation techniques have also provided information on the characteristics of the density turbulence at the periphery of L-mode plasmas as well as density perturbations due to coherent magnetohydrodynamic activity at the edge of H-mode plasmas. Precursor oscillations of the density in the pedestal region to edge-localized modes occurring during H-mode plasmas with a single-null diverted magnetic configuration are also observable in the raw signals from the trial BES system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi Optical Transition Radiation System for ATF2

In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes and emittances coming from the ATF Damping Ring. With an optical resolution of about 2 {micro}m an original OTR design (OTR1X) located after the septum at the entrance of the EXT line demonstrated the ability to measure a 5.5 {micro}m beam size in one beam pulse and to take many fast measurements. This gives the OTR the ability to measure the beam emittance with high statistics, giving a low error and a good understanding of emittance jitter. Furthermore the nearby wire scanners will be a definitive test of the OTR as a beam emittance diagnostic device. The multi-OTR system design proposed here is based on the existing OTR1X.

43 PARTICLE ACCELERATORS↗

Optoelectronic Tool Adds Scale Marks to Photographic Images

A simple, easy-to-use optoelectronic tool projects scale marks that become incorporated into photographic images (including film and electronic images). The sizes of objects depicted in the images can readily be measured by reference to the scale marks. The role played by the scale marks projected by this tool is the same as that of the scale marks on a ruler placed in a scene for the purpose of establishing a length scale. However, this tool offers the advantage that it can put scale marks quickly and safely in any visible location, including a location in which placement of a ruler would be difficult, unsafe, or time-consuming. The tool (see Figure 1) includes an aluminum housing, within which are mounted four laser diodes that operate at a wavelength of 670 nm. The laser diodes are spaced 1 in. (2.54 cm) apart along a baseline. The laser diodes are mounted with setscrews, which are used to adjust their beams to make them all parallel to each other and perpendicular to the baseline. During the adjustment process, the effect of the adjustments is observed by measuring the positions of the laser-beam spots on a target 80 ft (approx.24 m) away. Once the adjustments have been completed, the laser beams define three 1-in. (2.54-cm) intervals and the location of each beam is defined to within 1/16 in. (approx.1.6 mm) at any target distance out to about 80 ft (approx.24 m). The distance between the laser-beam spots as seen in an image is strictly defined only along an axis parallel to the baseline and perpendicular to the laser beam (also perpendicular to the line of sight of the camera, assuming that the camera-to-target distance is much greater than the distance between the tool and the camera lens). If a flat target surface illuminated by the laser beams is tilted with respect to the aforesaid axis, then the distance along the target surface between scale marks is proportional to the secant of the tilt angle. If one knows the tilt angle, one can correct for it. Even if one does not know the tilt angle precisely, it may not matter: For example, at a tilt of 10 , the secant is approximately 1.0154, so that the tilt error is only about 1.54 percent, which is negligibly small for a typical application in which only approximate measurements are needed.

Stevenson, Charlie↗

Electron beam generation in open hollow-cathode discharge and the characteristics of He-Xe laser on the Xe line at {lambda} = 2.026 {mu}m

An open hollow-cathode discharge, generating an electron beam, is implemented in a cell with an active volume of 6.2 L. An electron-beam current of 3.4 A at an average power of 2.5 kW is obtained in helium in the quasi-cw regime at an anode voltage of 1.5 kV. Lasing in a He-Xe mixture on the 5d[3/2]{sup 0}{sub 1}-6p[3/2]{sub 1} transition in xenon at the wavelength {lambda} = 2.026 {mu}m under electron-beam excitation is investigated. The optimal component ratio in the He : Xe mixture is 99.5 : 0.5 (p{sub He} = 4-8 Torr). The lasing power linearly increases with increasing the electron-beam power. It is shown that the discharge of this type can be used as an electron-beam source for exciting gaseous active media. (lasers)

43 PARTICLE ACCELERATORS↗

Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing

An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li–Etsion–Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-FG-BRA-07: Theranostic Gadolinium-Based AGuIX Nanoparticles for MRI-Guided Radiation Therapy

Purpose: AGuIX are gadolinium-based nanoparticles, initially developed for MRI, that have a potential role in radiation therapy as a radiosensitizer. Our goal is to demonstrate that these nanoparticles can both be used as an MRI contrast agent, as well as to obtain local dose enhancement in a pancreatic tumor when delivered in combination with an external beam irradiation. Methods: We performed in vitro cell uptake and radiosensitization studies of a pancreatic cancer cell line in a low energy (220kVp) beam, a standard clinical 6MV beam (STD) and a flattening filter free clinical 6MV beam (FFF). After injection of 40mM of nanoparticles, a biodistribution study was performed in vivo on mice with subcutaneous xenograft pancreatic tumors. In vivo radiation therapy studies were performed at the time point of maximum tumor uptake. Results: The concentration of AGuIX nanoparticles in Panc-1 pancreatic cancer cells, determined in vitro by MRI and ICPMS, peaks after 30 minutes with 0.3% of the initial concentration (5mg/g). Clonogenic assays show a significant effect (p<0.05) when the AGuIX are coupled with MV photon irradiation (DEF20%=1.31). Similar AGuIX tumor uptake is found in vivo by both MRI and ICPMS 30 minutes after intravenous injection. For long term survival studies, the choice of the radiation dose is determined with 5 control groups (3mice/group) irradiated with 0, 5, 10, 15, and 20Gy. Afterwards, 4 groups (8mice/group) are used to evaluate the effect of the nanoparticles. A Logrank test is performed as a statistical test to evaluate the effect of the nanoparticles. Conclusion: The combination of the MRI contrast and radiosensitization properties of gadolinium nanoparticles reveals a strong potential for usage with MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

GRO source candidates: (A) Nearby modest-size molecular clouds; (B) Pulsar with Wolf-Rayet companion that has lost its H-envelope

Within 100 pc of the sun there are over a hundred cirrus clouds with masses of approx. 60 solar mass and dense molecular clouds with masses of approx. 4 solar mass. If the local interstellar density of cosmic rays is also present in these clouds, the flux of neutral pion from the decay of gamma rays from the core of a cloud at a distance of 20 pc is approx. 13 x 10(exp -8) photons/sq cm/s. The flux from the more extensive cirrus cloud is approx 4 x 10(exp -7) photons/sq cm/s. A relativistic beam of particles generated by a compact stellar object and incident upon a large, close companion can be a strong gamma ray line source if more of the beam energy is used in interactions with C and O and heavier nuclei and less with H and He. This would be the case if the companion has lost its hydrogen envelope and nucleosynthesized much of its He into C, O, and Ne. Such objects are Wolf-Rayet stars and it is believed that some Wolf-Rayet stars do, in fact, have compact companions. For a beam of protons of 10(exp 37) erg/s, the flux at 1 kpc of the 4.4 MeV C-12 line could be as high as 5 x 10(exp -6) photons/sq cm/s. The fluxes of the deexcitation lines from the spallation products of O-16 are also presented.

Silberberg, R.↗

Coupling Measurements in ATF2 Extraction Line

The purpose of ATF2 is to deliver a beam with stable very small spotsizes as required for future linear colliders such as ILC or CLIC. To achieve that, precise controls of aberrations such as dispersion and coupling are necessary. Theoretically, the complete reconstruction of the beam matrix is possible from the measurements of horizontal, vertical and tilted beam sizes, combining skew quadrupole scans at several wire-scanner positions. Such measurements were performed in the extraction line (EXT) of ATF2 in May 2009. We present analysis results attempting to resolve the 4 x 4 beam matrix. We aimed to reconstruct the full beam matrix using only skew quadrupole scans at different EXT wire-scanner locations, with measurements of horizontal, vertical and two tilted beam size projections. Checking the coherence of the {sigma}{sub 13} reconstruction from the {sigma}{sub 80{sup o}} and the {sigma}{sub 100{sup o}} measurements was essential to perform this analysis. We have shown that reconstruction of the coupling element can not be performed independantly of the 4 x 4 diagonal ones since it leads to unphysical results. A more accurate and automatisable method was find, leading to physical beam matrix reconstruction, compatible with the measurements. Another analysis should be performed based on a larger number of data sets to minimise statistical errors.

43 PARTICLE ACCELERATORS↗

Specific features of formation of self-induced gratings on metal foils during scanning by a tightly focused femtosecond laser beam

Formation of self-induced gratings on a metal surface scanned by a focused femtosecond laser beam has been investigated. It is experimentally shown that application of femtosecond IR radiation allows one to form more ordered self-induced gratings as compared with the gratings formed by visible light. The dependence of the tilt of grating lines with respect to the beam polarisation direction on the distance between tracks and the beam motion direction in adjacent tracks is analysed. Formation of two-dimensional periodic gratings during double laser beam passage along the same trajectory but with a small difference in the beam polarisation directions has been found for the first time. (interaction of laser radiation with matter)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗