Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automated Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Implementation and Validation of Reference Sensitivity Profile Calculations in TRIPOLI 4 - 14247

In current neutron transport calculations, particularly on continuous-energy Monte-Carlo codes, the major source of uncertainty is coming from nuclear data. In order to improve nuclear data evaluations, integral experiments are used. Feedback is then precisely obtained by re-estimating cross-section levels and correlations according to their sensitivity. k{sub eff}-sensitivity coefficients are traditionally obtained using deterministic codes since hands-on methods were not yet implemented in continuous energy Monte Carlo codes. In this paper, an Iterated-Fission-Probability-based method newly developed in the continuous energy Monte Carlo code TRIPOLI-4 will be used to calculate sensitivity coefficient breakdown on isotopes and reactions and results will be compared to those of ERANOS deterministic code. Objective is twofold: to show the reliability of the new TRIPOLI-4 method and to identify where and why profiles are slightly different. Sensitivity profiles, forward and adjoint fluxes are thus meticulously compared using a fine 1968-group energy structure. An OECD international benchmark (Uncertainty Analysis for Criticality Safety Assessment - UACSA - Phase III) is taken as working example to enforce validation and to compare to independent results (e.g. MCNP-6). This benchmark is constituted of two bare spheres filled with homogeneous mixture of uranium and polyethylene (respectively 2% and 50% U-235 enrichments) and gives an overview of issues encountered in thermal reactor cores. Several energy-group structures (1968G, 172G, 33G) are also tested in ERANOS to identify multi-group and implicit effects. Lessons learnt are that continuous Monte Carlo methods seem to be mature and compare well with deterministic codes. Only damper the U-238 elastic - and on certain conditions the U-238 capture - sensitivity coefficient for which difference can reach 30% between TRIPOLI-4 and ERANOS. Indeed concerning U-238, implicit effects are emphasized and multi-group theory remains limited by hypothesis; even a 1968-group structure is not refined enough to properly calculate U-238 elastic scattering k{sub eff}-sensitivity. This reference 3D continuous-energy sensitivity capability in TRIPOLI4-IFP will be extensively used in the uncertainty automated tool RIB of the French Criticality-Safety package CRISTAL. (authors)

42 ENGINEERING↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control: Preprint

This paper validates the effectiveness of an Artificial Intelligence (AI)-driven PV plant control and optimization approach, namely, the Automated Learner for Intermittency Control by Extrapolation (ALICE), in empowering PV plant as a dependable grid reliability service provider. The validation is performed in a realistic laboratory controller-hardware-in-the-loop (CHIL) environment, leveraging accurate PV plant modeling and standard industrial communication protocol. Simulation results, considering both varying weather conditions and active control scenarios, demonstrate the superior performance of ALICE in improving the grid service delivery precision and reducing the over-curtailment compared to a state-of-the-art approach, i.e., reference-control grouping based approach. Such a work could help mitigate risks and provide practical guidance during the field deployment of ALICE, while establishing a standardized testing framework for evaluating various PV active control strategies.

hardware-in-the-loop↗

A general Bayesian algorithm for the autonomous alignment of beamlines

Autonomous methods to align beamlines can decrease the amount of time spent on diagnostics, and also uncover better global optima leading to better beam quality. The alignment of these beamlines is a high-dimensional expensive-to-sample optimization problem involving the simultaneous treatment of many optical elements with correlated and nonlinear dynamics. Bayesian optimization is a strategy of efficient global optimization that has proved successful in similar regimes in a wide variety of beamline alignment applications, though it has typically been implemented for particular beamlines and optimization tasks. In this paper, we present a basic formulation of Bayesian inference and Gaussian process models as they relate to multi-objective Bayesian optimization, as well as the practical challenges presented by beamline alignment. We show that the same general implementation of Bayesian optimization with special consideration for beamline alignment can quickly learn the dynamics of particular beamlines in an online fashion through hyperparameter fitting with no prior information. We present the implementation of a concise software framework for beamline alignment and test it on four different optimization problems for experiments on X-ray beamlines at the National Synchrotron Light Source II and the Advanced Light Source, and an electron beam at the Accelerator Test Facility, along with benchmarking on a simulated digital twin. We discuss new applications of the framework, and the potential for a unified approach to beamline alignment at synchrotron facilities.

47 OTHER INSTRUMENTATION↗

Development of a 3D optical scanning-based automatic quality assurance system for proton range compensators

Purpose: A new automatic quality assurance (AutoRCQA) system using a three-dimensional scanner (3DS) with system automation was developed to improve the accuracy and efficiency of the quality assurance (QA) procedure for proton range compensators (RCs). The system performance was evaluated for clinical implementation. Methods: The AutoRCQA system consists of a three-dimensional measurement system (3DMS) based on 3DS and in-house developed verification software (3DVS). To verify the geometrical accuracy, the planned RC data (PRC), calculated with the treatment planning system (TPS), were reconstructed and coregistered with the measured RC data (MRC) based on the beam isocenter. The PRC and MRC inner surfaces were compared with composite analysis (CA) using 3DVS, using the CA pass rate for quantitative analysis. To evaluate the detection accuracy of the system, the authors designed a fake PRC by artificially adding small cubic islands with side lengths of 1.5, 2.5, and 3.5 mm on the inner surface of the PRC and performed CA with the depth difference and distance-to-agreement tolerances of [1 mm, 1 mm], [2 mm, 2 mm], and [3 mm, 3 mm]. In addition, the authors performed clinical tests using seven RCs [computerized milling machine (CMM)-RCs] manufactured by CMM, which were designed for treating various disease sites. The systematic offsets of the seven CMM-RCs were evaluated through the automatic registration function of AutoRCQA. For comparison with conventional technique, the authors measured the thickness at three points in each of the seven CMM-RCs using a manual depth measurement device and calculated thickness difference based on the TPS data (TPS-manual measurement). These results were compared with data obtained from 3DVS. The geometrical accuracy of each CMM-RC inner surface was investigated using the TPS data by performing CA with the same criteria. The authors also measured the net processing time, including the scan and analysis time. Results: The AutoRCQA system accurately detected all fake objects in accordance with the given criteria. The median systematic offset of the seven CMM-RCs was 0.08 mm (interquartile range: −0.25 to 0.37 mm) and −0.08 mm (−0.58 to 0.01 mm) in the X- and Y-directions, respectively, while the median distance difference was 0.37 mm (0.23–0.94 mm). The median thickness difference of the TPS-manual measurement at points 1, 2, and 3 was −0.4 mm (−0.4 to −0.2 mm), −0.2 mm (−0.3 to 0.0 mm), and −0.3 mm (−0.6 to −0.1 mm), respectively, while the median difference of 3DMS was 0.0 mm (−0.1 to 0.2 mm), 0.0 mm (−0.1 to 0.3 mm), and 0.1 mm (−0.1 to 0.2 mm), respectively. Thus, 3DMS showed slightly better values compared to the manual measurements for points 1 and 3 in statistical analysis (p < 0.05). The average pass rate of the seven CMM-RCs was 97.97% ± 1.68% for 1-mm CA conditions, increasing to 99.98% ± 0.03% and 100% ± 0.00% for 2- and 3-mm CA conditions, respectively. The average net analysis time was 18.01 ± 1.65 min. Conclusions: The authors have developed an automated 3DS-based proton RC QA system and verified its performance. The AutoRCQA system may improve the accuracy and efficiency of QA for RCs.

07 ISOTOPE AND RADIATION SOURCES↗

Voronoi Meshing to Accurately Capture Geological Structure in Subsurface Simulations

Mesh generation lies at the interface of geological modeling and reservoir simulation. Highly skewed or very small grid cells may be necessary to accurately capture the geometry of geological features, but the resulting poorly scaled or small grid cells can have a substantial negative impact on simulator accuracy and speed. One way to minimize numerical errors caused by gridding complex structures is to simulate on high-quality Voronoi meshes, which reduce grid orientation effects in fluid flow. This work presents a complete methodology to create Voronoi simulation grids, model fluid flow in complex geological systems, and visualize the results. A recently developed Voronoi meshing method that can automatically generate provably good unstructured meshes that conform to input surfaces creating closed volumes is used. Initially an analytical benchmark simulation is presented to validate the quality of the meshes and simulation results and demonstrate the superiority of simulation results using Voronoi meshes over flexed-hexahedral meshes on a domain with internal features. Next, meshes are created for test structures representing four of the most common geological features in the subsurface: layering, pinch-out, an interior lens that tapers to zero thickness on all sides and a fault with offset. Two benchmark flow simulations are run for each test structure. Finally, a realistic geological example for CO 2 injection into an anticline is simulated. Three realizations of the Voronoi mesh at the same resolution are generated for the simulations. Each mesh is highly refined near the injection wells and coarse in areas of less interest. These three meshes are used to model the CO 2 plume in the subsurface as it migrates to the top of the structure and then fills downward. Simulations on the meshes with randomly generated elements inside the input volumes each give slightly different fingering patterns for the viscous-unstable buoyant gas flow. The results presented in this work show a promising step towards utilizing fully automated Voronoi meshing for subsurface flow simulations in complex geology.

58 GEOSCIENCES↗

MnEdgeNet for accurate decomposition of mixed oxidation states for Mn XAS and EELS L2,3 edges without reference and calibration

Accurate decomposition of the mixed Mn oxidation states is highly important for characterizing the electronic structures, charge transfer and redox centers for electronic, and electrocatalytic and energy storage materials that contain Mn. Electron energy loss spectroscopy (EELS) and soft X-ray absorption spectroscopy (XAS) measurements of the Mn L2,3 edges are widely used for this purpose. To date, although the measurements of the Mn L2,3 edges are straightforward given the sample is prepared properly, an accurate decomposition of the mix valence states of Mn remains non-trivial. For both EELS and XAS, 2+, 3+, and 4+ reference spectra need to be taken on the same instrument/beamline and preferably in the same experimental session because the instrumental resolution and the energy axis offset could vary from one session to another. To circumvent this hurdle, in this study, we adopted a deep learning approach and developed a calibration-free and reference-free method to decompose the oxidation state of Mn L2,3 edges for both EELS and XAS. A deep learning regression model is trained to accurately predict the composition of the mix valence state of Mn. To synthesize physics-informed and ground-truth labeled training datasets, we created a forward model that takes into account plural scattering, instrumentation broadening, noise, and energy axis offset. With that, we created a 1.2 million-spectrum database with 1-by-3 oxidation state composition ground truth vectors. The library includes a sufficient variety of data including both EELS and XAS spectra. By training on this large database, our convolutional neural network achieves 85% accuracy on the validation dataset. We tested the model and found it is robust against noise (down to PSNR of 10) and plural scattering (up to t/λ = 1). We further validated the model against spectral data that were not used in training. In particular, the model shows high accuracy and high sensitivity for the decomposition of Mn 3 O 4 , MnO, Mn 2 O 3 , and MnO 2 . The accurate decomposition of Mn 3 O 4 experimental data shows the model is quantitatively correct and can be deployed for real experimental data. Our model will not only be a valuable tool to researchers and material scientists but also can assist experienced electron microscopists and synchrotron scientists in the automated analysis of Mn L edge data.

25 ENERGY STORAGE↗

Design-to-Deployment Continuum Platform for Microscopes and Computing Ecosystems

Science ecosystems with networked computing systems and physical instruments are increasingly being deployed with a goal to achieve the productivity promised by AI-supported remote automation. In support of these efforts, the virtual infrastructure twins (VITs) have been successfully utilized to develop the orchestration codes for these ecosystems without requiring physical access to expensive instruments, such as electron microscopes. Currently, the utility of such a VIT is severely limited by the computing capacity and capability of the computing system used as its host. Furthermore, codes developed on the VIT typically need to be transferred and refactored for production use, particularly, on high-performance systems with accelerators. In response, we develop a design-to-deployment continuum platform wherein a VIT runs natively on the ecosystem's own computing system, and thereby facilitates the continual in-situ testing and transition of codes for production use. Here, we describe the development and testing of software for remote microscope steering and GPU-based image reconstruction using this platform on a multi-GPU computing system networked to Nion microscopes. We demonstrate a continual transition of steering and reconstruction codes developed under VIT platform to production ecosystem deployment.

Al-Najjar, Anees [Oak Ridge National Laboratory (O↗

CAT: computer aided triage improving upon the Bayes risk through ε-refusal triage rules

Manual extraction of information from electronic pathology (epath) reports to populate the Surveillance, Epidemiology, and End Result (SEER) database is labor intensive. Systematizing the data extraction automatically using machine-learning (ML) and natural language processing (NLP) is desirable to reduce the human labor required to populate the SEER database and to improve the timeliness of the data. This enables scaling up registry efficiency and collection of new data elements. To ensure the integrity, quality, and continuity of the SEER data, the misclassification error of ML and NPL algorithms needs to be negligible. Current algorithms fail to achieve the precision of human experts who can bring additional information in their assessments. Differences in registry format and the desire to develop a common information extraction platform further complicate the ML/NLP tasks. The purpose of our study is to develop triage rules to partially automate registry workflow to improve the precision of the auto-extracted information. This paper presents a mathematical framework to improve the precision of a classifier beyond that of the Bayes classifier by selectively classifying item that are most likely to be correct. This results in a triage rule that only classifies a subset of the item. We characterize the optimal triage rule and demonstrate its usefulness in the problem of classifying cancer site from electronic pathology reports to achieve a desired precision. From the mathematical formalism, we propose a heuristic estimate for triage rule based on post-processing the soft-max output from standard machine learning algorithms. We show, in test cases, that the triage rule significantly improve the classification accuracy.

60 APPLIED LIFE SCIENCES↗

Instrument for precision long-term β-decay rate measurements

We describe an experimental setup for making precision measurements of relative β-decay rates of {sup 22}Na, {sup 36}Cl, {sup 54}Mn, {sup 60}Co, {sup 90}Sr, {sup 133}Ba, {sup 137}Cs, {sup 152}Eu, and {sup 154}Eu. The radioactive samples are mounted in two automated sample changers that sequentially position the samples with high spatial precision in front of sets of detectors. The set of detectors for one sample changer consists of four Geiger-Müller (GM) tubes and the other set of detectors consists of two NaI scintillators. The statistical uncertainty in the count rate is few times 0.01% per day for the GM detectors and about 0.01% per hour on the NaI detectors. The sample changers, detectors, and associated electronics are housed in a sealed chamber held at constant absolute pressure, humidity, and temperature to isolate the experiment from environmental variations. The apparatus is designed to accumulate statistics over many years in a regulated environment to test recent claims of small annual variations in the decay rates. We demonstrate that absent this environmental regulation, uncontrolled natural atmospheric pressure variations at our location would imprint an annual signal of 0.1% on the Geiger-Müller count rate. However, neither natural pressure variations nor plausible indoor room temperature variations cause a discernible influence on our NaI scintillator detector count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of Gamma Spectrometry Systems for ORNL TRISO Fuel PIE

Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-96: Comparison of Frame-Based and Mutual Information Registration Techniques for CT and MR Image Sets

Purpose: To compare the accuracy of CT-MR registration using a mutual information method with registration using a frame-based localizer box. Methods: Ten patients having the Leksell head frame and scanned with a modality specific localizer box were imported into the treatment planning system. The fiducial rods of the localizer box were contoured on both the MR and CT scans. The skull was contoured on the CT images. The MR and CT images were registered by two methods. The frame-based method used the transformation that minimized the mean square distance of the centroids of the contours of the fiducial rods from a mathematical model of the localizer. The mutual information method used automated image registration tools in the TPS and was restricted to a volume-of-interest defined by the skull contours with a 5 mm margin. For each case, the two registrations were adjusted by two evaluation teams, each comprised of an experienced radiation oncologist and neurosurgeon, to optimize alignment in the region of the brainstem. The teams were blinded to the registration method. Results: The mean adjustment was 0.4 mm (range 0 to 2 mm) and 0.2 mm (range 0 to 1 mm) for the frame and mutual information methods, respectively. The median difference between the frame and mutual information registrations was 0.3 mm, but was not statistically significant using the Wilcoxon signed rank test (p=0.37). Conclusion: The difference between frame and mutual information registration techniques was neither statistically significant nor, for most applications, clinically important. These results suggest that mutual information is equivalent to frame-based image registration for radiosurgery. Work is ongoing to add additional evaluators and to assess the differences between evaluators.

60 APPLIED LIFE SCIENCES↗

Milone eTape Liquid Level Sensor Laboratory Calibration with a Commercial 12.2 cm HS-Flume and 3D Printed 4 cm Micro-HS-Flumes

The NGEE Arctic Rainfall Simulator (NARS) is a variable intensity rainfall simulator (RFS) with a frame design based on the Humphry et al. (2002) RFS and a water delivery system based on the Walnut Gulch (Paige et al., 2004) RFS. The NARS uses an aluminum frame that is fully deconstructable for transportation to field locations and a water system that enables variable rain intensity. Prior to field deployment, H-flume discharge and the corresponding Milone eTape Liquid Level Sensor (eTape) resistance values were measured in the laboratory so that discharge measurements from the NGEE Arctic Rainfall Simulator could be automated. eTape resistance was measured with increasing fluid heights for the full range of the eTape to calculate sensor detection limits and resolution. The eTape was calibrated to both a commercially available 12.2 cm HS-flume and a 3D printed 4 cm Micro-HS-flume. This data package contains two .csv files, one for the eTape calibration and the other for the flume calibrations, and two .stl files to 3D print the 4 cm Micro-HS-Flume design with a 1 cm x 3.6 cm stilling well opening. The .stl files can be opened in most 3D printing or CAD programs/software. Two .kml files of the laboratory location and broader area where testing was conducted are also included in this data package.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Irradiation Assessment of a Lightweight Industrial Robot - Towards Faster, Safer and Sooner Waste Decommissioning - 20317

Robotic systems have been successfully applied in the nuclear industry for several decades as a safe approach to minimize the exposure dose of human operators. As nuclear waste management and decommissioning gathers pace, there is an emerging interest integrating modern off-the-shelf industrial robots in nuclear robotic systems which make use of complex electronics and software to improve functionality over traditional machines. The use of the industrial robots will significantly increase the pace of development of automated waste management systems at a reduced cost, and although these off-the-shelf robots are proven robust in typical industrial environments, performance in radioactive environments is less clear. This paper investigates the performance degradation of a lightweight industrial robot (KUKA iiwa 7 LBR 800) in a controlled radiation field, aiming to simulate conditions in highly radioactive nuclear waste handling facilities. The degradation of the industrial robot's performance is identified while measuring the air kerma dose-tolerance of sensitive components, via a systematic experimental methodology. The experience from this experiment has demonstrated the significant capabilities of industrial robots, which tolerated a large gamma dose of 164 Gy before a system failure. Future tests are planned, aiming to enable faster, safer and sooner waste management and decommissioning using complex robotic systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a commercial automatic treatment planning system for prostate cancers

Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle{sup 3} radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle{sup 3} uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficient online quantum circuit learning with no upfront training

Optimization is a promising candidate for studying the utility of variational quantum algorithms (VQAs). However, evaluating cost functions using quantum hardware introduces runtime overheads that limit exploration. Surrogate-based methods can reduce calls to a quantum computer, yet existing approaches require hyperparameter pre-training and have been tested only on small problems. Here, we show that surrogate-based methods can enable successful optimization at scale, without pre-training, by using radial basis function interpolation (RBF) to construct an adaptive, hyperparameter-free surrogate. Using the surrogate as an acquisition function drives hardware queries to the vicinity of the true optima. For 16-qubit random 3-regular Max-Cut instances with the Quantum Approximate Optimization Algorithm (QAOA), our method outperforms state-of-the-art approaches, without considering their upfront training costs. Furthermore, we successfully optimize QAOA circuits for 127-qubit random Ising models on an IBM processor using 10 4 −10 5 measurements. Strong empirical performance demonstrates the promise of automated surrogate-based learning for large-scale VQA applications.

97 MATHEMATICS AND COMPUTING↗

Automated electrostatic probe device of high resolution and accuracy

In this work, an automated apparatus for driving single electrostatic probes and acquiring the plasma-related data has been designed and fabricated. The voltage range of the present system is ±110 V with an adjustable voltage step as low as 3 mV. Voltage and current measurements are carried out with high resolution and high accuracy circuits, both based on 16 bit analog-to-digital converters. The code embedded in a micro-controller, schedules the operation of the device and transfers the experimental data to a personal computer. The modular design of the system makes possible its modification and thus increases its adaptability to different plasma setups. Finally, the reliable operation of the entire device is confirmed by tests in Electron Cyclotron Resonance plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements on the Diagnostic Residual Gas Analyzer at Wendelstein 7-X

Exhaust gas analysis provides key information on fusion processes, divertor operation, and wall state in fusion experiments and future reactors. The diagnostic residual gas analyzer (DRGA) concept has been developed for ITER with a focus on fast helium and hydrogen isotope detection. The first operation of the prototype DRGA (P-DRGA) at the stellarator Wendelstein 7-X showed potential for improvement in terms of magnetic sensor shielding, data acquisition automation, and potential new additions to the cluster of sensors on the P-DRGA. More recently, a Monte Carlo simulation of the flow of the mixed gas species effluent from the pressure-reducing orifice, down to about 8-m sampling tube and into the analysis region of the sensors, has been found to generally agree with previous calculations and measurements but revealed potential back-streaming effects for light gases, with impact on detection limits both for the prototype and for the ITER DRGA currently in design. For the upcoming campaign of the prototype, an enhanced soft iron shield will safeguard the gauges against magnetic stray field influence. The newly introduced shielding has been tested for its effect on magnetic stray fields and found to reduce the inside residual field by about two orders of magnitude.

Schlisio, G↗