Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANGLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Pitch-angle diffusion of ions via nonresonant interaction with Alfvenic turbulence

The present discussion revisits the problem of nonresonant heating of ions by Alfvenic turbulence. It is shown that in the limit of weak Alfvenic turbulence it is appropriate to describe the nonresonant heating of protons as perpendicular pseudoheating. However, in a more general situation it is demonstrated that the more appropriate view of the nonresonant heating process is the pitch-angle scattering in the wave frame. The purpose of this paper is to generalize the earlier theory to the case in which the energy density of the turbulent Alfven waves is not necessarily very low. For weakly turbulent situation the present analysis confirms the earlier finding by Wu and Yoon [Phys. Rev. Lett. 99, 075001 (2007)], according to whom the nonresonant Alfven wave heating is described as leading to perpendicular pseudoheating of the protons. However, for more general situation the present paper demonstrates that pitch-angle scattering plays the principal role in the Alfven wave pseudoheating process, and thereby shows that the perpendicular heating discussed by Wu and Yoon is kinetic in nature, not attributable to fluid motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A spectral method for action-angle representation of linear waves in plasmas

Hamiltonian aspects of linear waves in plasmas are generally reviewed and discussed. Action-angle representation of linear waves is a fundamental problem, but it requires a careful mathematical consideration in the presence of continuum mode (continuous spectrum). We introduce a novel spectral technique that can treat continuous spectrum as well as discrete spectrum in a unified manner. Our method facilitates the derivation of action-angle variables, which is demonstrated for the Van Kampen mode in electrostatic plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Annealing effects of in-depth profile and band discontinuity in TiN/LaO/HfSiO/SiO{sub 2}/Si gate stack structure studied by angle-resolved photoemission spectroscopy from backside

We have investigated annealing effects on in-depth profile and band discontinuity for a metal gate/high-k gate stack structure on a Si substrate using backside angle-resolved photoemission spectroscopy with synchrotron radiation. In-depth profiles analyzed from angle-resolved photoemission spectroscopy show that La atoms diffuse through the HfSiO layer and reach interfacial SiO{sub 2} layers by rapid thermal annealing. Chemical shift of Si 2p core-level spectra suggests that there are changes in the band discontinuity at the high-k/SiO{sub 2} interface, which is well related to the V{sub th} shift based on the interface dipole model.

36 MATERIALS SCIENCE↗

A spin- and angle-resolving photoelectron spectrometer

A new type of hemispherical electron energy analyzer that permits angle and spin resolved photoelectron spectroscopy has been developed. The analyzer permits standard angle resolved spectra to be recorded with a two-dimensional detector in parallel with spin detection using a mini-Mott polarimeter. General design considerations as well as technical solutions are discussed and test results from the Au(111) surface state are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A simple method for measuring the superhydrophobic contact angle with high accuracy

A modified selected-plane method for contact angle ({theta}) measurement is proposed in this study that avoids the difficulty of finding the real contact point and image-distortion effects adjacent to the contact point. This method is particularly suitable for superhydrophobic surfaces. The sessile-drop method coupled with the tangent line is the most popular method to find the contact angle in literature, but it entails unavoidable errors in determining the air-solid base line due to the smoothness problem and substrate tilting. In addition, the tangent-line technique requires finding the actual contact point. The measurement error due to the base line problem becomes more profound for superhydrophobic surfaces. A larger {theta} deviation results from a more superhydrophobic surface with a fixed base line error. The proposed modified selected-plane method requires only four data points (droplet apex, droplet height, and two interfacial loci close to the air-solid interface), avoiding the problem of the sessile-drop-tangent method in finding the contact point and saving the trouble of the sessile-drop-fitting method for best fitting of the numerous edge points with the theoretical profile. A careful error analysis was performed, and a user-friendly program was provided in this work. This method resulted in an accurate {theta} measurement and a method that was much improved over the classical selected plane and the sessile-drop-tangent methods. The {theta} difference between this method and the sessile-drop-fitting method was found to be less than three degrees.

36 MATERIALS SCIENCE↗

Tunable ultrafast extreme ultraviolet source for time- and angle-resolved photoemission spectroscopy

We present a laser-based apparatus suitable for visible pump/extreme UV (XUV) probe time-, energy-, and angle-resolved photoemission spectroscopy utilizing high-harmonic generation from a noble gas. Tunability in a wide range of energies (currently 20-36 eV) is achieved by using a time-delay compensated monochromator, which also preserves the ultrashort duration of the XUV pulses. Using an amplified laser system at 10 kHz repetition rate, approximately 10{sup 9}-10{sup 10} photons/s per harmonic are made available for photoelectron spectroscopy. Parallel energy and momentum detection is carried out in a hemispherical electron analyzer coupled with an imaging detector. First applications demonstrate the capabilities of the instrument to easily select the probe wavelength of choice, to obtain angle-resolved photoemission maps (GaAs and URu{sub 2}Si{sub 2}), and to trace ultrafast electron dynamics in an optically excited semiconductor (Ge).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional ferroelectric domain imaging of epitaxial BiFeO{sub } thin films using angle-resolved piezoresponse force microscopy.

Here we introduce angle-resolved piezoresponse force microscopy (AR-PFM), whereby the sample is rotated by 30{sup o} increments around the surface normal vector and the in-plane PFM phase signals are collected at each angle. We obtained the AR-PFM images of BaTiO{sub 3} single crystal and cube-on-cube epitaxial (001) BiFeO{sub 3} (BFO) thin film on SrRuO{sub 3}/SrTiO{sub 3} substrate, and confirmed that the AR-PFM provides more unambiguous information on the in-plane polarization directions than the conventional PFM method. Moreover, we found eight additional in-plane polarization variants in epitaxial BFO thin films, which are formed to mitigate highly unstable charged domain boundaries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entanglement of charge transfer, hole doping, exchange interaction, and octahedron tilting angle and their influence on the conductivity of La{sub 1-x}Sr{sub x}Fe{sub 0.75}Ni{sub 0.25}O{sub 3-{delta}:} A combination of x-ray spectroscopy and diffraction

Substitution of La by Sr in the 25% Ni doped charge transfer insulator LaFeO{sub 3} leads to structural changes that inflect the electrical conductivity, which is caused by small polaron hopping via charge transfer and exchange interactions. The substitution forms electron holes and causes a structural transition from orthorhombic to rhombohedral symmetry, and then to cubic symmetry. The structural crossover is accompanied by a crossover from the Fe{sup 3+}-O{sup 2-}-Fe{sup 3+} superexchange interaction to the Fe{sup 3+}-O{sup 2-}-Fe{sup 4+} double exchange interaction in the course of substitution, as evidenced by a considerable increase in the conductivity at ambient temperature. The charge transfer and exchange interactions depend on the superexchange angle, which approaches 180 deg. upon increasing Sr concentration. An increase in superexchange angle leads to an increase in overlapping between the O 2p and the Fe/Ni 3d orbitals.

36 MATERIALS SCIENCE↗

On the Pointing Angle of Electron Beams from Laser Wakefield Accelerators

Laser wakefield accelerators offer electron beams which could be useful for many applications. However, the problem of stabilizing the electron beam parameters has not been resolved yet. Here, we propose a method to minimize the electron beam pointing and report the generation of a relativistic electron beam with a stabilized pointing angle of 2 mrad (rms). This was achieved by using asymmetric non-relativistic laser pulses interacting with low-density helium gas jet. In such a weakly-nonlinear regime, symmetric laser pulses were neither able to generate reproducible nor stable electron beams. Thus, we propose asymmetric laser pulses for generating electron beams having stable and small pointing angles from laser-plasma accelerators.

43 PARTICLE ACCELERATORS↗

The role of acceptance angle in measurements with ion energy analyzers: Study by numerical simulations

The importance of an acceptance angle in the plasma diagnostics with ion energy analyzers is investigated by means of numerical simulations. It is shown that wide acceptance angles result in low energy tails in measured ion distribution functions (IDF{sub x}). For flowing plasmas or plasmas with beams, the orientation of the analyzer's orifice gives different results due to bending of ion trajectories in the vicinity of the analyzer. It is demonstrated that the maximum in the IDF{sub x} is at energies lower than the plasma potential. Simulations are done with DIP3D, a three-dimensional particle-in-cell code.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geometric phase for collinear conical intersections. I. Geometric phase angle and vector potentials

We present a method for properly treating collinear conical intersections in triatomic systems. The general vector potential (gauge theory) approach for including the geometric phase effects associated with collinear conical intersections in hyperspherical coordinates is presented. The current study develops an introductory method in the treatment of collinear conical intersections by using the phase angle method. The geometric phase angle, {eta}, in terms of purely internal coordinates is derived using the example of a spin-aligned quartet lithium triatomic system. A numerical fit and thus an analytical form for the associated vector potentials are explicitly derived for this triatomic A{sub 3} system. The application of this methodology to AB{sub 2} and ABC systems is also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the Faraday angle by numerical methods and comparison with the Tore Supra and JET polarimeter electronics

On the Tore Supra tokamak, a far infrared polarimeter diagnostic has been routinely used for diagnosing the current density by measuring the Faraday rotation angle. A high precision of measurement is needed to correctly reconstruct the current profile. To reach this precision, electronics used to compute the phase and the amplitude of the detected signals must have a good resilience to the noise in the measurement. In this article, the analogue card's response to the noise coming from the detectors and their impact on the Faraday angle measurements are analyzed, and we present numerical methods to calculate the phase and the amplitude. These validations have been done using real signals acquired by Tore Supra and JET experiments. These methods have been developed to be used in real-time in the future numerical cards that will replace the Tore Supra present analogue ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel high resolution ion wide angle spectrometer

A novel ion wide angle spectrometer (iWASP) has been developed, which is capable of measuring angularly resolved energy distributions of protons and a second ion species, such as carbon C{sup 6+}, simultaneously. The energy resolution for protons and carbon ions is better than 10% at {approx}50 MeV/nucleon and thus suitable for the study of novel laser-ion acceleration schemes aiming for ultrahigh particle energies. A wedged magnet design enables an acceptance angle of 30 deg. ({approx}524 mrad) and high angular accuracy in the {mu}rad range. First, results obtained at the LANL Trident laser facility are presented demonstrating high energy and angular resolution of this novel iWASP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Classification procedure in limited angle tomography system

In this work we propose the use of limited angle reconstruction algorithms combined with a procedure for defect detection and feature evaluation in three dimensions. The procedure consists of the following steps: acquisition of the X-ray projections, approximated limited angle 3D image reconstruction, and image preprocessing and classification.

07 ISOTOPE AND RADIATION SOURCES↗

Time- and angle-resolved x-ray diffraction to probe structural and chemical evolution during Al-Ni intermetallic reactions

We present novel time- and angle-resolved x-ray diffraction (TARXD) capable of probing structural and chemical evolutions during rapidly propagating exothermic intermetallic reactions between Ni-Al multilayers. The system utilizes monochromatic synchrotron x-rays and a two-dimensional (2D) pixel array x-ray detector in combination of a fast-rotating diffraction beam chopper, providing a time (in azimuth) and angle (in distance) resolved x-ray diffraction image continuously recorded at a time resolution of {approx}30 {micro}s over a time period of 3 ms. Multiple frames of the TARXD images can also be obtained with time resolutions between 30 and 300 {micro}s over three to several hundreds of milliseconds. The present method is coupled with a high-speed camera and a six-channel optical pyrometer to determine the reaction characteristics including the propagation speed of 7.6 m/s, adiabatic heating rate of 4.0 x 10{sup 6} K/s, and conductive cooling rate of 4.5 x 10{sup 4} K/s. These time-dependent structural and temperature data provide evidences for the rapid formation of intermetallic NiAl alloy within 45 {micro}s, thermal expansion coefficient of 1.1 x 10{sup -6} K for NiAl, and crystallization of V and Ag{sub 3}In in later time.

36 MATERIALS SCIENCE↗

Pitch angle scattering of relativistic electrons from stationary magnetic waves: Continuous Markov process and quasilinear theory

We develop a Markov process theory of charged particle scattering from stationary, transverse, magnetic waves. We examine approximations that lead to quasilinear theory, in particular the resonant diffusion approximation. We find that, when appropriate, the resonant diffusion approximation simplifies the result of the weak turbulence approximation without significant further restricting the regime of applicability. We also explore a theory generated by expanding drift and diffusion rates in terms of a presumed small correlation time. This small correlation time expansion leads to results valid for relatively small pitch angle and large wave energy density - a regime that may govern pitch angle scattering of high-energy electrons into the geomagnetic loss cone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements

Localized measurements of the fast ion velocity distribution function and the plasma composition measurements are of significant interest for the fusion community. Collective Thomson scattering (CTS) diagnostics allow such measurements with spatial and temporal resolution. Localized measurements require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic on TEXTOR without a source of probing radiation in discharges with sawtooth oscillations, an elevation angle misalignment of 0.9 Degree-Sign was found with an accuracy of 0.25 Degree-Sign .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulated heterodyne light scattering set-up for measuring long relaxation time at small and wide angle

We present a simple, compact, and versatile experimental setup working in the heterodyne detection mode with modulation of the reference beam. The system is implemented with a collection optics based on a unimodal optical fiber coupler. This choice allows the heterodyne to be used in a wide range of scattering angles, even for very small ones, without losing the optical beating. The apparatus can be successfully used to study translational diffusive dynamics of dispersed particles at scattering angles smaller than 5 Degree-Sign and it is suitable for exploring slow relaxation processes in sub-Hertz frequency domain, for example, in glass-forming systems. It is also possible to measure the electrophoretic mobility by applying an electric field into a charged particles solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗