Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wavefront shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

NASA Tech Briefs, March 2010

Topics covered include: Software Tool Integrating Data Flow Diagrams and Petri Nets; Adaptive Nulling for Interferometric Detection of Planets; Reducing the Volume of NASA Earth-Science Data; Reception of Multiple Telemetry Signals via One Dish Antenna; Space-Qualified Traveling-Wave Tube; Smart Power Supply for Battery-Powered Systems; Parallel Processing of Broad-Band PPM Signals; Inexpensive Implementation of Many Strain Gauges; Constant-Differential-Pressure Two-Fluid Accumulator; Inflatable Tubular Structures Rigidized with Foams; Power Generator with Thermo-Differential Modules; Mechanical Extraction of Power From Ocean Currents and Tides; Nitrous Oxide/Paraffin Hybrid Rocket Engines; Optimized Li-Ion Electrolytes Containing Fluorinated Ester Co-Solvents; Probabilistic Multi-Factor Interaction Model for Complex Material Behavior; Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators; Compact Rare Earth Emitter Hollow Cathode; High-Precision Shape Control of In-Space Deployable Large Membrane/Thin-Shell Reflectors; Rapid Active Sampling Package; Miniature Lightweight Ion Pump; Cryogenic Transport of High-Pressure-System Recharge Gas; Water-Vapor Raman Lidar System Reaches Higher Altitude; Compact Ku-Band T/R Module for High-Resolution Radar Imaging of Cold Land Processes; Wide-Field-of-View, High-Resolution, Stereoscopic Imager; Electrical Capacitance Volume Tomography with High-Contrast Dielectrics; Wavefront Control and Image Restoration with Less Computing; Polarization Imaging Apparatus; Stereoscopic Machine-Vision System Using Projected Circles; Metal Vapor Arcing Risk Assessment Tool; Performance Bounds on Two Concatenated, Interleaved Codes; Parameterizing Coefficients of a POD-Based Dynamical System; Confidence-Based Feature Acquisition; Algorithm for Lossless Compression of Calibrated Hyperspectral Imagery; Universal Decoder for PPM of any Order; Algorithm for Stabilizing a POD-Based Dynamical System; Mission Reliability Estimation for Repairable Robot Teams; Processing AIRS Scientific Data Through Level 3; Web-Based Requesting and Scheduling Use of Facilities; AutoGen Version 5.0; Time-Tag Generation Script; PPM Receiver Implemented in Software; Tropospheric Emission Spectrometer Product File Readers; Reporting Differences Between Spacecraft Sequence Files; Coordinating "Execute" Data for ISS and Space Shuttle; Database for Safety-Oriented Tracking of Chemicals; Apparatus for Cold, Pressurized Biogeochemical Experiments; Growing B Lymphocytes in a Three-Dimensional Culture System; Tissue-like 3D Assemblies of Human Broncho-Epithelial Cells; Isolation of Resistance-Bearing Microorganisms; Oscillating Cell Culture Bioreactor; and Liquid Cooling/Warming Garment.

Source record↗

X-ray photonic microsystems for the manipulation of synchrotron light

In this study, photonic microsystems played an essential role in the development of integrated photonic devices, thanks to their unique spatiotemporal control and spectral shaping capabilities. Similar capabilities to markedly control and manipulate X-ray radiation are highly desirable but practically impossible due to the massive size of the silicon single-crystal optics currently used. Here we show that micromechanical systems can be used as X-ray optics to create and preserve the spatial, temporal and spectral correlation of the X-rays. We demonstrate that, as X-ray reflective optics they can maintain the wavefront properties with nearly 100% reflectivity, and as a dynamic diffractive optics they can generate nanosecond time windows with over 100-kHz repetition rates. Since X-ray photonic microsystems can be easily incorporated into lab-based and next-generation synchrotron X-ray sources, they bring unprecedented design flexibility for future dynamic and miniature X-ray optics for focusing, wavefront manipulation, multicolour dispersion, and pulse slicing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metasurface-based multi-harmonic free-electron light source

Metasurfaces are subwavelength spatial variations in geometry and material where the structures are of negligible thickness compared to the wavelength of light and are optimized for far-field applications, such as controlling the wavefronts of electromagnetic waves. Here, we investigate the potential of the metasurface near-field profile, generated by an incident few-cycle pulse laser, to facilitate the generation of high-frequency light from free electrons. In particular, the metasurface near-field contains higher-order spatial harmonics that can be leveraged to generate multiple higher-harmonic X-ray frequency peaks. We show that the X-ray spectral profile can be arbitrarily shaped by controlling the metasurface geometry, the electron energy, and the incidence angle of the laser input. Using ab initio simulations, we predict bright and monoenergetic X-rays, achieving energies of 30 keV (with harmonics spaced by 3 keV) from 5-MeV electrons using 3.4-eV plasmon polaritons on a metasurface with a period of 85 nm. As an example, we present the design of a four-color X-ray source, a potential candidate for tabletop multicolor hard X-ray spectroscopy. Our developments could help pave the way for compact multi-harmonic sources of high-energy photons, which have potential applications in industry, medicine, and the fundamental sciences.

36 MATERIALS SCIENCE↗

High Accuracy Coronagraph Flight Model For WFIRST–CGI Raw Contrast Sensitivity Analysis

A high-accuracy high-fidelity flight wavefront control (WFC) model is developed for detailed raw contrast sensitivity analysis of WFIRST-CGI. Built upon features of recently testbed validated model, it is further refined to combine a full Fresnel propagation diffraction model for high accuracy contrast truth evaluation, and an economical compact model for WFC purposes. Extensive individual raw contrast error sensitivities are evaluated systematically, both as known imperfections and as unknown calibration errors, for both spectroscopy mode and wide field-of-view mode with shaped pupil coronagraph. More than 90 distinct error items were identified, including system aberrations, optical misalignment, component manufacturing error, telescope interface related errors, etc. The result forms the basis for raw contrast error budget flow down to a sub-system level, where detailed specifications needed to aid in component design and manufacturing, mechanical alignment and instrument integration, and verification and validation operations. Evaluations are mostly automated, making it relatively easy for repeat runs of revised design or at new desired error quantity. Top error sensitivities and contrast floor contributors are discussed and several observations are noted.

Poberezhskiy, Ilya↗

Controlling X-ray deformable mirrors during inspection

The X-ray deformable mirror (XDM) is becoming widely used in the present synchrotron/free-electron laser facilities because of its flexibility in correcting wavefront errors or modification of the beam size at the sample location. Owing to coupling among the N actuators of an XDM, (N + 1) or (2N + 1) scans are required to learn the response of each actuator one by one. When the mirror has an important number of actuators (N) and the actuator response time including stabilization or the necessary metrology time is long, the learning process can be time consuming. In this paper, a fast and accurate method is presented to drive an XDM to a target shape usually with only three or four measurements during inspection. The metrology data are used as feedback to calculate the curvature discrepancy between the current and the target shapes. Three different derivative estimation methods are introduced to calculate the curvature from measured data. The mirror shape is becoming close to the target through iterative compensations. Finally, the feasibility of this simple and effective approach is demonstrated by a series of experiments.

42 ENGINEERING↗

A Variable Eddington Factor Model for Thermal Radiative Transfer with Closure Based on Data-Driven Shape Function

Here, a new variable Eddington factor (VEF) model is presented for nonlinear problems of thermal radiative transfer (TRT). The VEF model is data-driven and acts on known (a-priori) radiation-diffusion solutions for material temperatures in the TRT problem. A linear auxiliary problem is constructed for the radiative transfer equation (RTE) whose emission source and opacities are evaluated at these known material temperatures. The solution to this RTE approximates the specific intensity distribution in phase-space and time. It is applied as a shape function to define the Eddington tensor for the presented VEF model. The shape function computed via the auxiliary RTE problem will capture some degree of transport effects within the TRT problem. The VEF moment equations closed with this approximate Eddington tensor will thus carry with them these captured transport effects. In this study, the temperature data comes from multigroup P 1 , P 1/3 , and flux-limited diffusion radiative transfer models. The proposed VEF model can be interpreted as a transport-corrected diffusion reduced-order model. Numerical results are presented on the Fleck-Cummings test problem which models a supersonic wavefront of radiation. The VEF model is shown to improve accuracy by 1–2 orders of magnitude compared to the considered radiation-diffusion model solutions to the TRT problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-contrast imaging with an arbitrary aperture: Active compensation of aperture discontinuities

We present a new method to achieve high-contrast images using segmented and/or on-axis telescopes. Our approach relies on using two sequential deformable mirrors (DMs) to compensate for the large amplitude excursions in the telescope aperture due to secondary support structures and/or segment gaps. In this configuration the parameter landscape of DM surfaces that yield high-contrast point-spread functions is not linear, and nonlinear methods are needed to find the true minimum in the optimization topology. We solve the highly nonlinear Monge-Ampere equation that is the fundamental equation describing the physics of phase-induced amplitude modulation. We determine the optimum configuration for our two sequential DM system and show that high-throughput and high-contrast solutions can be achieved using realistic surface deformations that are accessible using existing technologies. We name this process Active Compensation of Aperture Discontinuities (ACAD). We show that for geometries similar to the James Webb Space Telescope, ACAD can attain at least 10{sup –7} in contrast and an order of magnitude higher for both the future extremely large telescopes and on-axis architectures reminiscent of the Hubble Space Telescope. We show that the converging nonlinear mappings resulting from our DM shapes actually damp near-field diffraction artifacts in the vicinity of the discontinuities. Thus, ACAD actually lowers the chromatic ringing due to diffraction by segment gaps and struts while not amplifying the diffraction at the aperture edges beyond the Fresnel regime. This outer Fresnel ringing can be mitigated by properly designing the optical system. Consequently, ACAD is a true broadband solution to the problem of high-contrast imaging with segmented and/or on-axis apertures. We finally show that once the nonlinear solution is found, fine tuning with linear methods used in wavefront control can be applied to further contrast by another order of magnitude. Generally speaking, the ACAD technique can be used to significantly improve a broad class of telescope designs for a variety of problems.

79 ASTRONOMY AND ASTROPHYSICS↗

Microlens Array Laser Transverse Shaping Technique for Photoemission Electron Source

A common issue encountered in photoemission electron sources used in electron accelerators is distortion of the laser spot due to non ideal conditions at all stages of the amplification. Such a laser spot at the cathode may produce asymmetric charged beams that will result in degradation of the beam quality due to space charge at early stages of acceleration and fail to optimally utilize the cathode surface. In this note we study the possibility of using microlens arrays to dramatically improve the transverse uniformity of the drive laser pulse on UV photocathodes at both Fermilab Accelerator Science \& Technology (FAST) facility and Argonne Wakefield Accelerator (AWA). In particular, we discuss the experimental characterization of the homogeneity and periodic patterned formation at the photocathode. Finally, we compare the experimental results with the paraxial analysis, ray tracing and wavefront propagation software.

43 PARTICLE ACCELERATORS↗

Wavefront preserving X-ray optics for Synchrotron and Free Electron Laser photon beam transport systems

We report in the last two decades, after the first light from the new Free Electron Lasers, either in the UV (FLASH and FERMI@Elettra) or X-ray (LCLS and SACLA), more and more new diffraction limited sources have been either constructed or planned. Third generation storage rings are upgraded to provide a more collimated, brighter, and coherent light for the next generation experimental techniques. X-ray optics are the bridge between the light sources and the experimental stations. They are the key to the success of advanced experiments but also the potential bottleneck preventing the exploitation of the full characteristics of the source. The beam degradation originated by any mirror defect (either from mirror polishing or from contamination) is amplified with a coherent source. Delivering diffraction-limited spots, including the option for variable spot sizes in and out of focus, requires the control of the surface of the optics at the 1 nm rms level, if not better. At LCLS, only very recently an almost perfectly uniform beam out of focus has been obtained in the hard X-rays. It has been obtained after two 1-m long mirrors with 0.5 nm rms shape precision (after installation). Those mirrors were not readily available just a decade ago. But, thanks to the pioneering work performed at the Osaka University, those optics are now commercially available with arbitrary tangential profiles. This new generation of mirrors permits achieving unprecedented results. However, they do not remove all road blocks to a perfect photon transport system. Instead, they highlighted the critical importance of mirror mounting, handling of the thermal deformation, and the need of advanced diagnostics to properly exploit all the new potentiality of these optics. Besides the need of “perfect” mirrors, other aspects of the beamline design and elements may impact the quality of the beam in the experimental station, from the lack of blaze gratings to the need of advanced simulation tools, just to cite two. In this article, after a brief historical excursus, we will present the current state of the art of mirrors, gratings, crystals, lenses, diagnostics, and simulation tools. The main problems yet to solve and a look ahead at what would be achievable in the next decade will give the reader an idea on the search for an almost ideal photon transport system and how the path toward experiments, not conceivable today, will unfold.

47 OTHER INSTRUMENTATION↗

Study of gas-puff Z-pinches on COBRA

Gas-puff Z-pinch experiments were conducted on the 1 MA, 200 ns pulse duration Cornell Beam Research Accelerator (COBRA) pulsed power generator in order to achieve an understanding of the dynamics and instability development in the imploding and stagnating plasma. The triple-nozzle gas-puff valve, pre-ionizer, and load hardware are described. Specific diagnostics for the gas-puff experiments, including a Planar Laser Induced Fluorescence system for measuring the radial neutral density profiles along with a Laser Shearing Interferometer and Laser Wavefront Analyzer for electron density measurements, are also described. The results of a series of experiments using two annular argon (Ar) and/or neon (Ne) gas shells (puff-on-puff) with or without an on- (or near-) axis wire are presented. For all of these experiments, plenum pressures were adjusted to hold the radial mass density profile as similar as possible. Initial implosion stability studies were performed using various combinations of the heavier (Ar) and lighter (Ne) gasses. Implosions with Ne in the outer shell and Ar in the inner were more stable than the opposite arrangement. Current waveforms can be adjusted on COBRA and it was found that the particular shape of the 200 ns current pulse affected on the duration and diameter of the stagnated pinched column and the x-ray yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tandem neural network-based controller for x-ray bimorph mirrors

Nanometer-scale shape control of x-ray mirrors is crucial for coherent x-ray beam experiments at low-emittance synchrotron beamline instruments. Piezoelectric bimorph mirrors offer adaptive control but are hindered by nonlinearities such as cross talk, creep, and hysteresis. To overcome these limitations, we present a novel feedback-free control solution, inspired by the proportional–integral–derivative (PID) scheme, driven by tandem neural networks (TNNs). Using task-specific datasets, the TNN-based system predicts actuator voltages with greater speed, accuracy, and stability than a single NN-based model. This approach is ideal for real-time applications, such as adapting beam focus to dynamic sample sizes while maintaining precise wavefront quality. Our findings highlight the potential of artificial intelligence in rapidly optimizing adaptive optics and managing nonlinear control systems.

Zhang, Runyu↗

RST Optical Telescope Integration and Test Preparation

The OTA for the Nancy Grace Roman Space Telescope includes the primary mirror, secondary mirror, and aft optics for guiding light into the Wide Field Instrument and the Coronagraph Instrument. The telescope is taking shape as the tested optical mirror assemblies are integrated. The assemblies have been thermal cycled to the cold temperatures for infrared operation, load tested to launch loads, vibration tested, and optically tested. Testing included launch-level vibration testing of the 2.4-meter light-weighted primary mirror assembly. In addition, the telescope control electronics (TCE) box has been fully assembled and the environmental testing of the TCE is progressing. Pictures and descriptions of the integration and test progress are provided, along with performance results measured at these levels of assemblies. Planning and test equipment preparation for the telescope thermal vacuum testing continues including plans to take advantage of the large dynamic range available with focus diversity phase retrieval and a Shack-Hartmann wavefront sensor for the gravity-sagged primary mirror.

Tony L Whitman↗

InAs Terahertz Metalens Emitter for Focused Terahertz Beam Generation

Metasurfaces have opened doors to combining multiple photonic functionalities in a single compact device. In particular, the ability to generate short terahertz (THz) pulses with precise wavefront engineering in a single THz metasurface redefined the role metasurfaces can play in THz systems. Here, an InAs metalens emitter which generates and focuses a THz pulse beam is demonstrated using a 130 nm thick InAs metasurface designed as a binary‐phase Fresnel zone plate. The THz beam is focused to a spot of ≈430 μm at 1 THz with a short focal length of 5 mm and large numerical aperture of 0.5. Nanoscale InAs Mie resonators comprising the metasurface enable THz generation with an amplitude as high as 20 times compared to plasmonic THz emitters and several times compared to a 1 mm thick ZnTe crystal. This InAs metasurface emitter provides a new paradigm for designing THz imaging, spectroscopy, and communication systems, where THz beam generation and shaping are performed with a single device without compromising the generation efficiency, while eliminating losses and avoiding limitations of phase matching of conventional nonlinear optics approaches.

47 OTHER INSTRUMENTATION↗

Enabling High-Contrast Imaging of Binary Stars With the Roman Space Telescope Coronagraph Instrument

A large fraction of Sun-like stars is contained in binary systems, in fact within 10 pc there are 67 FGK stars, out of which 42 belong to a multi-star system, and 28 have companion leak that is greater than 1e-9 contrast, assuming typical Hubble-quality space optics. Currently, those binary stars are not included in the Roman Space Telescope Coronagraph Instrument target list, but they could be observed if high-contrast imaging around binary star systems using Roman was possible. The Multi-Star Wavefront Control (MSWC) algorithm can be used to suppress companion star leakage. If the targets have angular separations larger than the Nyquist controllable region of the Deformable Mirror, MSWC must operate in its Super-Nyquist (SN) mode. This mode requires a target star replica within the SN region in order to provide the ability to null speckles at SN angular separations. For the case of Roman, more than half of the targets that can be observed using MSWC, including Alpha Centauri, have angular separations larger than the Nyquist controllable region of the 48x48 actuator Deformable Mirror (DM) to be used. In this paper, we describe how super-Nyquist MSWC can be implemented in Roman CGI adding a mild grating on a replica of the Wide-field Shaped Pupil mask, which would use a spare space in the Shaped Pupil Active Mechanism. We present the feasibility analysis, simulation results, and discuss the latest results on MSWC experiment from three different laboratories at NASA Ames, the Jet Propulsion Laboratory, and the Subaru telescope.

Prada, Camilo Mejia↗

Investigation of focusing and correcting aberrations with binary amplitude and polarization modulation

Here, we investigate the focusing and correcting wavefront aberration of an optical wave using binary amplitude and polarization modulation. Focusing is performed by selectively modulating the field in different zones of the pupil to obtain on-axis constructive interference at a given distance. The conventional Soret zone plate (binary amplitude profile) is expanded to a polarization Soret zone plate with twice the focusing efficiency. Binary pixelated devices that approximate the sinusoidal transmission profile of a Gabor zone plate by spatial dithering are also investigated with amplitude and polarization modulation. Wavefront aberrations are corrected by modulation of the field in the pupil plane to prevent destructive interference in the focal plane of an ideal focusing element. Polarization modulation improves the efficiency obtained by amplitude-only modulation, with a gain that depends on the aberration. Experimental results obtained with Cr-on-glass devices for amplitude modulation and liquid crystal devices operating in the Mauguin condition for polarization modulation are in very good agreement with simulations.

47 OTHER INSTRUMENTATION↗

Apodized Pupil Lyot Coronagraphs for arbitrary apertures. V. Hybrid shaped pupil designs for imaging earth-like planets with future space observatories

We introduce a new class of solutions for Apodized Pupil Lyot Coronagraphs (APLC) with segmented aperture telescopes to remove broadband diffracted light from a star with a contrast level of 10{sup 10}. These new coronagraphs provide a key advance to enabling direct imaging and spectroscopy of Earth twins with future large space missions. Building on shaped pupil (SP) apodization optimizations, our approach enables two-dimensional optimizations of the system to address any aperture features such as central obstruction, support structures, or segment gaps. We illustrate the technique with a design that could reach a 10{sup 10} contrast level at 34 mas for a 12 m segmented telescope over a 10% bandpass centered at a wavelength of λ{sub 0} = 500 nm. These designs can be optimized specifically for the presence of a resolved star and, in our example, for stellar angular size up to 1.1 mas. This would allow one to probe the vicinity of Sun-like stars located beyond 4.4 pc, therefore, fully retiring this concern. If the fraction of stars with Earth-like planets is η{sub ⊕}=0.1, with 18% throughput, assuming a perfect, stable wavefront and considering photon noise only, 12.5 exo-Earth candidates could be detected around nearby stars with this design and a 12 m space telescope during a five-year mission with two years dedicated to exo-Earth detection (one total year of exposure time and another year of overheads). Our new hybrid APLC/SP solutions represent the first numerical solution of a coronagraph based on existing mask technologies and compatible with segmented apertures, and that can provide contrast compatible with detecting and studying Earth-like planets around nearby stars. They represent an important step forward toward enabling these science goals with future large space missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

A New Integral Field Spectrograph for Broadband Coronagraph Demonstrations at the High Contrast Imaging Testbed Facility

An integral field spectrograph (IFS) camera may help fulfill the exoplanet characterization goals of a future Habitable Worlds Observatory. During the Nancy Grace Roman Space Telescope mission formulation phase, the Coronagraph Instrument Project established the laboratory performance baseline of a combined coronagraph and IFS system with the Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES; 1E-8 contrast over an 18% bandpass; 3--9 lambda/D bowtie-shaped control region). New laboratory demonstrations are needed to expand on this milestone in terms of contrast, bandpass, and field of view towards the requirements of a future mission capable of characterizing the atmospheres of Earth-like exoplanets. Here we present the design of a successor to PISCES that can observe a 20 lambda/D-diameter field of view with an instantaneous bandpass up to 30%, at a resolving power R > 70 at visible wavelengths. This instrument will interface with the existing coronagraph layout in the High Contrast Imaging Facility DST-2 vacuum chamber. The addition of a spectroscopic imaging camera at HCIT will benefit the wider coronagraph technology community by enabling other NASA-supported investigators to automatically obtain multi-wavelength measurements of speckles both inside and outside of their control region, and the instrument will support community-led demonstrations of high-order wavefront sensing and control techniques such as dark hole maintenance and linear dark field control.

coronagraph↗