Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A System of Agents for Supporting Optimization and Control of a Connected Community

The residential sector consumes a significant portion of the electricity sold in the United States. Above 60% of the energy used in the sector is used to operate heating, ventilation, and air conditioning (HVAC) systems and water heating (WH) systems. With the increase of intelligence in the grid and the new decision and control options enabled by the Internet of Things; control of these devices can be used to support the grid. Therefore, this article presents a scalable multiagent system for optimizing HVAC and WH systems while maintaining comfort. It allows a utility to orchestrate the shifting of energy from critical periods without direct control, but instead by using a price signal. The architecture, optimization formulation, implementation strategy and results from an implementation project are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat Transfer and Pressure Drop Characteristics of Water Flow Boiling in Internally Enhanced Tubes

Flow boiling is a critical process for many thermal conversion processes such as HVAC&R, water heating, power generation and desalination applications. The major goal of this paper is to enhance the in-tube heat transfer for flow boiling of water and further improve the efficiency of the boiler. This paper presents an experimental investigation of the heat transfer and pressure drop characteristics for water under forced convection and boiling conditions inside both smooth and enhanced tubes. The results in the smooth copper tube are compared with several correlations and used as a baseline. The two-phase heat transfer and pressure drop performance of the water flow boiling in the internally enhanced tube is investigated, and the influence of internal surface pattern on the thermal characteristics is discussed. The relations of the heat transfer coefficient with mass flux, heat flux and vapor quality are analyzed according to the results.

Yang, Cheng-Min↗

Preliminary investigation of heat transfer to water flowing in an electrically heated Inconel tube

A heat-transfer investigation was conducted with water flowing in an electrically heated Inconel tube with an inside diameter of 0.204 inch and a length-diameter ratio of 50 for ranges of Reynolds number up to 100,000 and of entrance pressure up to 200 inches of mercury gage. Correlation of average heat-transfer coefficients was obtained by use of the familiar Nusselt relation, wherein the physical properties of water were evaluated at an average bulk temperature. For conditions in which no boiling occurred, the data gave a good correlation. Runs made in the nucleate-boiling region, however, gave higher values of heat-transfer coefficient than would be predicted by the Nusselt relation.

Kaufman, Samuel J↗

Heat Rejection Concepts for Lunar Fission Surface Power Applications

This paper describes potential heat rejection design concepts for lunar surface Brayton power conversion systems. Brayton conversion systems are currently under study by NASA for surface power applications. Surface reactors may be used for the moon to power human outposts enabling extended stays and closed loop life support. The Brayton Heat Rejection System (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Space Brayton conversion system designs tend to optimize at efficiencies of about 20 to 25 percent with radiator temperatures in the 400 K to 600 K range. A notional HRS was developed for a 100 kWe-class Brayton power system that uses a pumped water heat transport loop coupled to a water heat pipe radiator. The radiator panels employ a tube and fin construction consisting of regularly-spaced circular heat pipes contained within two composite facesheets. The water heat pipes interface to the coolant through curved sections partially contained within the cooling loop. The paper evaluates various design parameters including radiator panel orientation, coolant flow path, and facesheet thickness. Parameters were varied to compare design options on the basis of H2O pump pressure rise and required power, heat pipe unit power and radial flux, radiator area, radiator panel areal mass, and overall HRS mass.

Siamidis, John↗

Installation package - SIMS prototype system 1A

This report consists of details for the installation, operation and maintenance of a prototype heating and hot water system, designed for residential or light commercial applications. This system consists of the following subsystems: air type collectors, pebble bed thermal storage, air handling unit, air to water heat exchanger, hot water preheat tank, auxiliary energy, ducting system.

Source record↗

Next Generation Refrigerants for Domestic Heat Pump Water Heaters

To select next generation refrigerants and phase out R-134a, we conducted extensive drop-in tests of multiple new refrigerants. For laboratory investigations, we performed drop-in UEF (uniform energy factor) and FHR (first hour rating) tests on two heat pump water heaters (HPWHs), one uses a 220V compressor and 40-gallon water tank, and the other uses a 120V compressor and 50-gallon tank. The alternative refrigerants/blends include R-1234yf, R-1234ze, R-515B, R-513A, and R-516A, among which R-513A is A1, non-flammable and the others are in A2L category. All the alternative refrigerants required similar optimum system charges as the baseline R-134a. They resulted in similar or better UEFs than R-134a. R-516A led to best UEFs in both the HPWHs. The resultant discharge temperatures of the new refrigerants/blends are lower than R-134a, indicating good lubricant compatibility. The 120V HPWH delivered > 60 gallons first-hour rating using R-134a. The alternatives led to reduced FHRs due to their smaller volumetric vaporization capacities using the same compressor. Except R-515B, the other refrigerants/blends delivered FHRs > 60 gallons. R-516A produced better UEFs and FHRs in both the units than the other replacements. If considering flammability, R-513A would be the best option, which has similar UEF and FHR as R-134a.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Nontargeted vs. Targeted vs. Smart Load Shifting Using Heat Pump Water Heaters

Deployment of CTA-2045–enabled devices is increasing in the U.S. market. These devices allow utilities or third-party aggregators to control appliance energy use in homes, and could also be applied to end uses in small commercial buildings. This study focuses on a field study using CTA-2045–enabled water heaters to shift electric load off the peak and toward periods when renewable resources are more prevalent (e.g., near noon for solar resources and near midnight for wind resources). The following load shifting strategies were compared to understand effects on the aggregate load-shifting capabilities of Heat Pump Water Heaters (HPWHs) and on consumer hot water supply: non-targeted (traditional), targeted (grouped, with different shifting schedules) and “smart” (adaptive control commands). The results of this study show that targeted and smart control strategies yield significantly more load-shifting potential from a population of water heaters than the non-targeted approach without sacrificing hot water supply to occupants. However, as control commands become more aggressive, aggregators may face challenges in meeting consumer hot water demand. Furthermore, the findings and lessons learned can benefit electric utilities and inform updates to manufacturer controls and communications standards. The data collected may also be useful for developing and validating HPWH models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Simulation of a Water-Cooled Heat Pump

A Fortran-language computer program for simulating the operation of a water-cooled vapor-compression heat pump in any orientation with respect to gravity has been developed by modifying a prior general-purpose heat-pump design code used at Oak Ridge National Laboratory (ORNL).

Bozarth, Duane↗

The House that NASA Built

Tech House, located at NASA's Langley Research Center, Hampton, Virginia, is a demonstration project in which aerospace and commercial building technology are combined to produce an energy-efficient home. Advanced technology offers savings to the family in utility costs and energy conservation. Solar panels on the roof of tech house provide the principal energy saving. They capture the sun's rays to heat water in pipes that run through the solar collectors. The heated water is then stored in a large, well insulated underground tank. A heat exchanger extracts beat from the water and blows it through ducts to warm the house. Tech House is well insulated for energy savings. The principal insulation is fireproof Tripolymer foam which is sprayed onto walls and ceilings in thicknesses up to six inches.

Source record↗

Solar Water Heater

As a Jet Propulsion Laboratory (JPL) scientist Dr. Eldon Haines studied the solar energy source and solar water heating. He concluded he could build a superior solar water heating system using the geyser pumping principle. He resigned from JPL to develop his system and later form Sage Advance Corporation to market the technology. Haines' Copper Cricket residential system has no moving parts, is immune to freeze damage, needs no roof-mounted tanks, and features low maintenance. It provides 50-90 percent of average hot water requirements. A larger system, the Copper Dragon, has been developed for commercial installations.

Source record↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗