Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Control Strategy for Energy Storage System in Sustainable Distribution System Operation

Due to the increasing penetration of distributed energy resources (DERs) required for the sustainable distribution system, new voltage control strategy is needed by utilities. Traditional voltage control strategy can not support the increasing number of DERs in a coordinated and scalable manner to meet the operational voltage regulation requirement. Supported by the power electronics converter, the energy storage system can provide fast, smooth, and flexible voltage control services. In this paper, an effective and easy to implement sensitivity-based voltage control strategy is developed for the energy storage system. The developed control strategy is validated using an industrial feeder data in Northwest Washington. The proposed strategy can mitigate the voltage unbalance issue, improve the voltage profile, and correct power factors while supporting sustainable distribution system operation.

Zhang, Yue (ORCID:0000000241469716)↗

Analysis of System and Interoperability Impact from Securing Communications for Distributed Energy Resources

As the power grid incorporates increasing amounts of distributed energy resources (DER) that provide new generation sources, new opportunities are created for improving operation of the grid while large challenges also arise for preserving grid reliability and security. To improve grid performance, DERs can be utilized to provide important support functionality, such as supporting frequency and voltage levels, especially if they are assisted by communication schemes as part of an advanced distribution management system (ADMS). Unfortunately, such connectivity and grid support functionality also creates additional cyber security risk with the potential for degradation of grid services, especially under conditions with high amounts of distributed generation. This paper will first discuss the communications needed by DERs to support system and interoperability objectives, as well as the security requirements and impact of securing these communications. Some common security mechanisms are discussed in relation to DERs, and a simulated 15-bus model of a distribution feeder is used to demonstrate aspects of the DER communications and impact to grid performance. These results help to advance understanding of the benefits, requirements, and mechanisms for securely implementing DER communications while ensuring that grid reliability is maintained.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative Model Predictive Control Scheme for Dispersed Smart Inverters at the Grid Edge

Growing number of distributed energy resources (DERs) requires cutting-edge control schemes to ensure uniform but not identical involvement of DERs to address rapid fluctuations on voltage of the grid clusters. Designing such control schemes for a grid with high penetration of DERs connected various clusters is complex and depends on physical configuration of the clusters themselves. This paper proposes a two-layered cooperative model predictive control scheme for fleet of dispersed smart inverters connected to a three-phase grid cluster located at the edge of a grid cluster. The upper layer of the controller ensures cooperative operation of fleet of smart inverters to perform voltage regulation and address voltage fluctuations in the grid cluster; while the lower level controller guarantees each individual inverter obeys the dictated references for active/reactive powers by the upper layer controller. In addition, the proposed twolayered controller has low voltage ride through (LVRT) capability to support the grid clusters during voltage sags. By employing the proposed control approach, the smart inverters will inject desired active/reactive powers based on circumstance of the entire cluster while guaranteeing proper power curtailment among the generation units. The control scheme is verified by simulation.

Fard, Amin Y.↗

Elucidating the Dynamic Nature of Fuel Cell Electrodes as a Function of Conditioning: An ex Situ Material Characterization and in Situ Electrochemical Diagnostic Study

To increase the commercialization of fuel cell electric vehicles, it is imperative to improve the activity and performance of electrocatalysts through combined efforts focused on material characterization and device-level integration. Obtaining fundamental insights into the ongoing structural and compositional changes of electrocatalysts is crucial for not only transitioning an electrode from its as-prepared to functional state, also known as 'conditioning', but also for establishing intrinsic electrochemical performances. Here, we investigated several oxygen reduction reaction (ORR) electrocatalysts via in situ and ex situ characterization techniques to provide fundamental insights into the interfacial phenomena that enable peak ORR mass activity and high current density performance. A mechanistic understanding of a fuel cell conditioning procedure is described, which encompasses voltage cycling and subsequent voltage recovery (VR) steps at low potential. In particular, ex situ membrane electrode assembly characterization using transmission electron microscopy and ultra-small angle X-ray scattering were performed to determine changes in carbon and Pt particle size and morphology, while in situ electrochemical diagnostics were performed either during or after specific points in the testing protocol to determine the electrochemical and interfacial changes occurring on the catalyst surface responsible for oxygen transport resistances through ionomer films. The results demonstrate that the voltage cycling (break-in) step aids in the removal of sulfate and fluoride and concomitantly reduces non-Fickian oxygen transport resistances, especially for catalysts where Pt is located within the pores of the carbon support. Subsequent low voltage holds at low temperature and oversaturated conditions, i.e., VR cycles, serve to improve mass activities by a factor of two to three, through a combined removal of contaminants, surface-blocking species (e.g., oxides), and rearrangement of the catalyst atomic structure (e.g., Pt-Pt and Pt-Co coordination).

30 DIRECT ENERGY CONVERSION↗

Cryogenic lifetime tests on a commercial epoxy resin high voltage bushing

High-temperature superconducting (HTS) power devices operating in liquid nitrogen frequently require high-voltage bushings to carry the current leads from the superconducting windings to the room temperature grid connections. Oak Ridge National Laboratory is collaborating with Waukesha Electric Systems, SuperPower, and Southern California Edison to develop and demonstrate an HTS utility power transformer. Previous dielectric high voltage tests in support of this program have been carried out in test cryostats with commercial epoxy resin bushings from Electro Composites Inc. (ECI). Though the bushings performed well in these short-term tests, their long-term operation at high voltage in liquid nitrogen needs to be verified for use on the utility grid. Long-term tests are being carried out on a sample 28-kV-class ECI bushing. The bushing has a monolithic cast, cycloaliphatic resin body and is fire- and shatter-resistant. The test cryostat is located in an interlocked cage and is energized at 25 kVac around the clock. Liquid nitrogen (LN) is automatically refilled every 9.5 hours. Partial discharge, capacitance, and leakage resistance tests are periodically performed to check for deviations from factory values. At present, over 2400 hours have been accumulated with no changes in these parameters. The tests are scheduled to run for four to six months.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

Aggregated DER_A Model Parameterization via Online Moving Horizon Estimation

Here, this paper introduces a methodology for parameterizing the DER_A model using a novel smooth mathematical representation, simplifying the process and preserving accuracy in modeling inverter-based generator (IBG). The methodology employs an online parameterization process that can operate in real-time. The model parameterization process is structured into five sequential steps, each targeting a specific aspect of the DER_A model through moving horizon estimation. This approach adapts to systems with varying voltage and frequency support requirements by selectively applying each step. Simulation results on systems with both known and unknown parameters validate the methodology’s effectiveness. The online moving horizon estimation technique accurately captures the dynamics of the overall system and ensures that the parameterized DER_A model closely mirrors the real system’s voltage, current, and power dynamics. The findings highlight the potential of this methodology to substantially improve and simplify the dynamic modeling of power systems, paving the way for more reliable and robust IBG and grid integration.

42 ENGINEERING↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sulfur Solutions: Advancing High Voltage and High Energy Lithium Batteries with Organosulfur Electrolytes

Achieving energy densities exceeding 350 Wh kg -1 while operating at elevated voltages (>4.5 V vs Li/Li + ) is attainable through judicious selection of electrochemical pairs at the cathode and anode. However, current state-of-the-art electrolytes exhibit limited stability when exposed to systems operating at or above 4.3 V. This limitation contributes to the degradation of electrode materials and raises critical safety concerns, impeding the commercialization of such systems. Consequently, there has been a notable surge in research efforts aimed at developing innovative electrolyte compositions capable of supporting high-voltage lithium-ion batteries (LIBs). A substantial portion of this research has focused on the family of organosulfur molecules, which possess high oxidative stability. Organosulfur salts also facilitate the formation of dense, ionically conductive solid electrolyte interfaces (SEI) and demonstrate excellent solubility. This article provides a comprehensive overview of the field of organosulfur electrolyte components for their applications in energy storage, encompassing solvents, alternative conducting salts, and additives. It emphasizes the idea that the deliberate design of electrolyte compositions is instrumental in controlling electrode passivation, with organosulfur-based structures historically proving advantageous in every aspect of the electrolyte. Crucially, it should be noted that many of these components are commercially available, holding significant implications for industrial applications.

25 ENERGY STORAGE↗

Real-time Implementation of Grid Code Compliant Grid Edge Energy Management System

Integrated distributed energy resources (DER) in a distribution system need to follow grid codes to avoid violations that result in DER/circuit segment disconnection. To comply with grid code requirements at the grid edge level, network constrained grid edge energy management system (EMS) can be deployed. The objective of grid edge EMS is to provide economic solution for active and reactive power DER setpoints at each dispatch interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system with multiple inverter based DER units. In this work, real-time simulation of grid code compliant grid edge EMS is deployed in a realistic feeder circuit segment. For real-time simulation, communication between the grid edge EMS and DERs is done exploiting IEC 61850-7-420. It enables interoperability among different DERs and grid edge EMS. No prior art has deployed IEC 61850-7-420 GOOSE communication protocol for grid edge EMS. Conversion of IEC 61850 GOOSE messages to Modbus communication protocol is also performed to communicate with grid edge EMS in commodity-off the shelf embedded boards in this work. The real-time simulation in OPAL-RT real-time digital simulator shows the out-performance of grid edge EMS by reducing the voltage violation in the distribution circuit.

Energy management system↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Diagnosing and overcoming recombination and resistive losses in non-silicon solar cells using a silicon-inspired characterization platform

This project aimed to generate the characterization tools needed for accurate and systematic loss analysis in non-silicon photovoltaic solar cell technologies and, through the use of these tools and analysis techniques, contribute to the development of a novel class of hetero-contacts to II-VI absorbers, with the final goal of demonstrating record-breaking CdSeTe devices. CdSeTe solar cells provide a prime example of the potential impact of the techniques we proposed to develop and implement: record poly-CdSeTe cells have bandgap-voltage deficits (W oc ) of approximately 550 mV, as compared with below 400 mV for all other mature PV technologies. Similarly, these record CdSeTe devices have FFs below 80%, when other mature cells are near or above 85%. Frustratingly, a systematic identification of the origin of these sub-par performances—for example recombination or resistive losses—has been lacking, thus slowing down the development of these technologies. Similarly, it is often asserted that CdSeTe cells need a better back (hole) contact. Although most believe this is true, no one knew—at the start of this project—how high the V oc and FF could be for a given cell if it had a perfect back contact. Such characterization techniques and loss analysis methods exist and are routinely performed on c-Si solar cells (e.g. injection-dependent lifetime, Suns-V oc , transfer length method, etc). Over the years, they have been instrumental in the development of silicon devices that operate at 91% of their theoretical (Auger) limit. Lifetime testing, and the associated reconstruction of the implied-J-V curve, can moreover be performed at every cell-processing step, thus allowing a direct peek into the impact of that step on cell performance. Therefore, adapting these techniques and tools to non-Si devices would greatly improve their learning rate. In this project, we developed a Suns-ERE technique—the equipment, methodology, and know-how—to measure the implied-J-V curve, the pseudo-J-V curve, and the actual J-V curve of a thin-film solar cell, allowing an accurate assessment of the quality of the bulk material and its surface passivation, the selectivity of the contact, and its resistivity. We used this technique to show that the absorber of present CdSeTe solar cells is capable of achieving 1 V Voc,, that passivation layers exist (e.g., Al2O3) that can support such high voltages, and that the barrier is identifying contact layers that are both passivating and carrier-selective. The characterization platform created in this project and the understanding generated using it will accelerate the progress of non-silicon PV technologies. In particular, the project will contribute to CdSeTe solar cells with Voc > 1 V and cell efficiency > 24%. Such cells provide a pathway to module-level efficiencies >23%. As CdSeTe presently competes with silicon on module cost (in $\$ $/W) and yet has significantly more room for efficiency gains, the potential for LCOE reduction is particularly large. For example, CdTe modules with an efficiency of 21% would allow an LCOE below $\$ $0.04kWh -1 in average US climates.

14 SOLAR ENERGY↗