Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Sequential Model Predictive and Deep Reinforcement Learning-Based Controller for Distribution System Outage Mitigation under Hurricane Events

This paper proposes a proactive outage mitigation framework for power distribution networks to withstand hurricane-induced disruptions. It leverages Model Predictive Control (MPC) to identify safe lines for proactive switching during hurricanes, minimizing the risk of cascading failures and voltage violations. The switching strategies optimized by MPC are sequentially integrated with a Deep Reinforcement Learning agent using the Advantage Actor-Critic algorithm, enabling dynamic line switching to maximize connected buses and minimize voltage violations in real time. Using a probabilistic hurricane model, the framework predicts line failures and adapts to varying conditions to enhance grid resilience. Simulations on the IEEE 123-bus system demonstrate its effectiveness in maintaining high connectivity and minimizing disruptions. Real-time testing with an RTDS confirms the practicality and reliability of the proposed approach.

Selim, Alaa [University of Connecticut]↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Artificial intelligence inferred microstructural properties from voltage–capacity curves

Abstract The quantification of microstructural properties to optimize battery design and performance, to maintain product quality, or to track the degradation of LIBs remains expensive and slow when performed through currently used characterization approaches. In this paper, a convolution neural network-based deep learning approach (CNN) is reported to infer electrode microstructural properties from the inexpensive, easy to measure cell voltage versus capacity data. The developed framework combines two CNN models to balance the bias and variance of the overall predictions. As an example application, the method was demonstrated against porous electrode theory-generated voltage versus capacity plots. For the graphite|LiMn $$_2$$ 2 O $$_4$$ 4 chemistry, each voltage curve was parameterized as a function of the cathode microstructure tortuosity and area density, delivering CNN predictions of Bruggeman’s exponent and shape factor with 0.97 $$R^2$$ R 2 score within 2 s each, enabling to distinguish between different types of particle morphologies, anisotropies, and particle alignments. The developed neural network model can readily accelerate the processing-properties-performance and degradation characteristics of the existing and emerging LIB chemistries.

25 ENERGY STORAGE↗

Characteristics and mathematical modeling of apple slice drying in an electrohydrodynamic system with a needle‐plate electrode

Abstract The drying of apple slices in an electrohydrodynamic (EHD) system with a needle‐plate electrode was characterized and mathematically modeled at voltages of 30, 40, and 50 kV and with distances between needles of 5, 6, and 7 cm. The results showed that the drying rate, effective water diffusion coefficient, and rehydration ratio of the apple slices, and specific energy consumption of drying, all increased with increasing voltage. Initially, there was a period when the drying rate was approximately constant in the low‐voltage EHD, but not in the high voltage conditions. At the same voltage, the drying rate was highest when the distance between needles was 6 cm. The voltage and distance between needles had a significant ( p < .05) interactive effect on the effective water diffusion coefficient and specific energy consumption, but not on the rehydration ratio. General mathematical models for drying can be used to represent the drying behavior of apple slices. The Midilli and Kucuk model and the Logarithmic model had the best fits, with correlation coefficients of 0.998803 and 0.998267, respectively. Predictive functions for the moisture ratio of apple slices based on voltage and distance between needles were established and verified. The results indicated that the Logarithmic model could more accurately predict the moisture ratio of apple slices dried using the EHD method. Practical Applications As a new drying technology, electrohydrodynamic (EHD) drying has unequaled advantages. According to the results, using the appropriate voltage and distance between needles improves not only drying efficiency, but also the rehydration ratio of apple slices, which reflects the quality of dried products. The Logarithmic model can accurately predict the EHD drying behavior of apple slices, which is of great significance in optimizing actual production.

Li, Bowen↗

Four-Switch Buck-Boost Converter Based on Model Predictive Control with Smooth Mode Transition Capability

Four-switch buck-boost converter supports both voltage step-up and step-down functionalities, but it suffers from mode transfer challenge that would need reliable mode detection when designed to operate in multi different modes. In this paper, a novel control method based on model predictive current control is proposed for such converter with inherent smooth mode transfer capability without extra design on mode detection and transfer scheme. Modulator and mode detection are replaced by an optimization process through cost function. This largely simplifies the design and makes it easily implemented. Therefore, seamless transfer between buck and boost modes is achieved with many other system level benefits. Simulation and experimental results are provided to verify the effectiveness of proposed method for the four-switch buck-boost converter.

42 ENGINEERING↗

Data-Driven Voltage Regulation of Distribution Grid Using Nonlinear Autoregressive Model with Exogenous Inputs (NARX)

This article proposes data-driven control via a nonlinear autoregressive model with exogenous inputs (NARX) for real-time voltage regulation of a modified feeder using reactive power sources. Traditional voltage control strategies rely on rule-based heuristics or optimization techniques, which often require detailed system models and extensive computational resources. The NARX-based controller learns system dynamics from historical data and predicts optimal reactive power dispatch in real-time for voltage correction. The proposed approach is evaluated on a power system feeder model under varying load and network conditions. Simulation results demonstrate that the NARX-based controller achieves improved voltage regulation, offering higher adaptability to system fluctuations. This study highlights the potential of data-driven control for enhancing the reliability of power distribution networks.

Donge, Vrushabh [ORNL] (ORCID:0000000306062803)↗

Discharging Behavior of Hollandite α-MnO 2 in a Hydrated Zinc-Ion Battery

Hollandite, α-MnO 2 , is of interest as a prospective cathode material for hydrated zinc ion batteries (ZIBs); however, the mechanistic understanding of the discharge process remains limited. Herein, a systematic study on the initial discharge of α-MnO 2 cathode under hydrated environment was reported using density functional theory (DFT) in combination with complementary experiments, where the DFT predictions well described the experimental measurements on discharge voltages and manganese oxidation states. According to the DFT calculations, both protons (H + ) and zinc ions (Zn 2+ ) contribute to the discharging potentials of α-MnO 2 observed experimentally, where the presence of water plays an essential role during the process. This study provides valuable insights into the mechanistic understanding of the discharge of α-MnO 2 in hydrated ZIBs, emphasizing the crucial interplay among the H 2 O molecules, the intercalated Zn 2+ or H + ions, and the Mn 4+ ions on the tunnel wall to enhance the stability of discharged states and, thus, the electrochemical performances in hydrated ZIBs.

25 ENERGY STORAGE↗

A Voltage Inference Framework for Real-Time Observability in Active Distribution Grids

Active distribution grids are gaining traction to meet the growing environmental, socio-economic, and sustainability targets. Various advanced smart grid technologies facilitate the integration of Distributed Energy Resources (DERs) by supporting the bi-directional power flow. The limited observability of distribution grids, primarily related to their location at the very edge of power system infrastructure, brings challenges to optimal grid management. Moreover, only a limited number of measurements at regular intervals are usually available. This paper presents a novel inference framework, referred to as “Voltage Inference”, to overcome the observability issues. The proposed framework employs a prediction step based on the Multivariate Taylor series approximation, followed by a corrector step that minimizes the estimation error to infer the otherwise unknown voltages from the available measurements. Furthermore, numerical results on the IEEE 13-bus test feeder validate the accuracy and computational performance of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods and systems for diagnosis of failure mechanisms and for prediction of lifetime of metal batteries

Methods for diagnosing failure mechanisms and for predicting lifetime of metal batteries include monitoring rest voltage and Coulombic Efficiency over relatively few cycles to provide profiles that indicate, by the trends thereof, a particular failure mechanism (e.g., electrolyte depletion, loss of metal inventory, increased cell impedance). The methods also include cycling over relatively few cycles an anode-free cell, having the same cathode and electrolyte as the metal battery, but with a current collector instead of the anode. Discharge capacity is monitored and profiled, and a discharge capacity curve is fitted to the discharge capacity profile to discern a capacity retention per cycle. The lifetime of the metal battery is determined using the capacity retention per cycle discerned from the anode-free cell. Related systems include a metal-based battery and an anode-free cell or a battery cell reconfigurable between a metal-based and an anode-free cell.

Li, Bin↗

First-principles investigation of high capacity, rechargeable CF x cathode batteries based on graphdiyne and “holey” graphene carbon allotropes

Batteries composed of CF x cathodes have high theoretical specific capacities (>860 mA h g -1 ). Attempts at realizing such batteries coupled with Li anodes have failed to deliver on this promise, however, due to a discharge voltage plateau below the theoretical maximum lowering the realized energy density and difficulties with recharging the system. Here, in this study, we use first-principles calculations to investigate novel carbon allotropes for these battery systems: graphdiyne and “holey” graphene. We first identify stable flourination structures and calculate their band gaps. We demonstrate that the holes in these carbon allotropes can induce the formation of an amorphous LiF network within the carbon and that this formation may, in fact, be kinetically favored. For structures where amorphous LiF forms within the carbon, we predict it is easier to recharge and higher discharge voltages can be achieved. If the LiF forms outside the carbon product, however, it will be crystalline in form and lead to lower discharge voltages and more difficulty in recharging the systems. Finally, we simulate XPS spectra of representative cases, demonstrating an experimental pathway for determining the reaction pathway of these systems. Our work suggests CF x allotropes with holes in them as potential targets for high capacity, rechargeable cathodes for Li batteries, provided they lead to the formation of amorphous LiF within the C structure.

25 ENERGY STORAGE↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Efficiency Model Predictive Control for Star-Connected Cascaded H-Bridge STATCOM Under Unbalanced Conditions

This paper presents a high-efficiency model predictive control (HMPC), which is enabled by a sorting approach based on dc capacitor voltages to significantly reduce the exponentially-increasing switching states in cascaded Hbridge (CHB) converters. In addition, a generic discrete-time prediction model for star-connected CHB static synchronous compensator is proposed to address the issues due to either grid and/or load unbalances. Both simulation and hardware-in-loop experimental results are presented to validate the feasibility and effectiveness of the proposed HMPC strategy.

Li, Yufei↗

Capacitance of Carbon Nanotube/Graphene Composite Electrodes with [BMIM + ][BF$_4^–$]/Acetonitrile: Fixed Voltage Molecular Dynamics Simulations

The capacitance of nanoporous carbon electrode materials is dictated by the physical interactions with electrolyte ions and molecules at the accessible interior electrode surface. While significant progress has been made in designing and synthesizing carbon materials with well-defined and relatively homogeneous nanoporosity, the majority of materials remain heterogeneous, and the resulting properties reflect an average over this distribution. In this regard, computer simulations can be a valuable tool to predict or validate structure/property relationships by systematically investigating well-defined, model electrode morphologies. In this work, we utilize fixed-voltage molecular dynamics simulations to predict structure/capacitance relationships for five different model morphologies of carbon nanotube/graphene (CNT/G) composite electrodes with 1-butyl-3-methylimidazolium tetrafluoroborate/acetonitrile electrolyte. The CNT/G electrode models are inspired by experimental “layer-by-layer” syntheses and strike a balance between realism and computational tractability. Comparison between different model electrode architectures elucidates important structure/property relationships. We find that CNT/graphene contact points serve as “hot spots” with significantly enhanced charge separation relative to the rest of the electrode. Furthermore, we demonstrate a specific nanoconfinement motif that provides substantial 3–4$\times$ enhancement of local capacitance, resulting in a ~40% increase of the total electrode differential capacitance. Because the accessible surface area of the model CNT/G electrodes is precisely determined, a comparison of per-area capacitance across systems is unambiguous. Our results thus complement a prior computational demonstration of capacitance enhancement in nanoconfinement while elucidating additional interaction motifs at CNT/G electrochemical interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling salt adsorption in electrical double layer for capacitive deionization

Abstract This work presents an electrical double layer (EDL) model for capacitive deionization (CDI) by intercorrelating the salt adsorption, the electrode voltage, and the surface charge density. The counterion condensation is considered a crucial contribution to salt adsorption because of the high surface charge density in the charged micropores. The counterions condense when the surface charge density exceeds a critical value, which is predicted by the counterion condensation theory. The EDL model accurately correlates the NaCl salt adsorption and electrode voltage with various surface charge densities and well predicts the salt adsorption in a wide range of external salt concentrations. The EDL model reproduces the non‐monotonic relationship between the salt adsorption and the specific surface area observed in experiments and provides an explanation from the modeling perspective. Exhibiting superior accuracy and predictability for salt adsorption, the EDL model could serve as an enabling tool contributing to the development of CDI processes.

Lin, Yu‐Jeng↗