Engineering PapersSearch

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Cyberattack Detection and Mitigation on Central Volt‐VAr Using Circuit Law and Machine Learning

ABSTRACT In a distribution grid, voltage is maintained within a nominal range through a Volt‐VAr function that controls capacitor banks, reactive power of distributed energy resources (DER), and on‐load tap changers (OLTC). Availability of communications helps with the implementation of central Volt‐VAr control; however, it also opens the system to cyberattacks, causing voltage disturbances. Previous work has shown the adverse impacts of false data injection (FDI) on the central Volt‐VAr control; however, very few works have studied methods to detect and mitigate FDI on Volt‐VAr control. This paper addresses gaps in the detection and mitigation of FDI on the measurement packets of a central Volt‐VAr control. This work uses a two‐stage algorithm for cyberattack detection since the accuracy of a single‐stage machine learning (ML)–based detection method decreases while dealing with unseen data. The first stage is based on the verification of measurements against circuit laws, and the second stage utilizes a tree search algorithm and an ML method to detect the falsified data. This paper compares long short‐term memory (LSTM) and bidirectional LSTM (BiLSTM) as the employed ML algorithms. Finally, the mitigation algorithm replaces the falsified data with the estimated output of the ML algorithm. The effectiveness of the proposed method is tested for several cases using the IEEE 13‐bus test system in PSCAD software.

Beikbabaei, Milad [Bradley Department of Electrica

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE

Full complex amplitude control of second-harmonic generation via electrically tunable intersubband polaritonic metasurfaces

Nonlinear intersubband polaritonic metasurfaces based on coupling of the intersubband nonlinear optical response of quantum-engineered semiconductor heterostructures and electromagnetic modes of nanoresonators provide efficient frequency mixing with moderate pump intensities. The resonant nonlinear optical response, represented as a complex function, can be modulated via Stark tuning of intersubband transition energies under applied voltages. However, achieving full complex amplitude control (both phase and magnitude) remains challenging. In this work, we present and experimentally validate electrically tunable nonlinear intersubband polaritonic metasurfaces that achieve complete complex amplitude control for second-harmonic generation (SHG). Through a design featuring two in-plane flipped meta-atoms per unit cell, we achieve complete electrical control of both the amplitude and phase of the metasurface second-order nonlinear susceptibility, with a tuning range of 0 to 30 nm V −1 for the magnitude and 0-2π for the phase of the nonlinear optical response. Using these properties, we achieve complete on-off SHG modulation and beam diffraction tuning through electrically controlled amplitude and phase gratings.

Science & Technology - Other Topics

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

24 POWER TRANSMISSION AND DISTRIBUTION

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation

Optimizing Grid Regulation with Gravity Energy Storage Systems: A Comparative Analysis with Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a highinertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

ENERGY STORAGE,POWER TRANSMISSION AND DISTRIBUTION

Voltage Service Limits Smart Contract Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Generator

Modern electrical grids face growing stability risks from customer-owned generators, especially at points of common couplings (PCCs). Disruptive behavior from power-electronic sources can cause protective relays to isolate problematic generators, making measurement integrity critical. This article presents a distributed ledger technology (DLT) approach that uses smart contracts to evaluate PCC voltage measurements and trigger backup breaker operations. The approach is framed as a verifiable, multi-organization attestation and audit layer, not as a real-time control security mechanism. In the proposed architecture, voltage measurements from a hardware protective relay are anchored on a DLT through the Cyber Grid Guard (CGG) system for attestation by both the grid utility and customer-owned generator. A Voltage Service Limits (VSLs) smart contract evaluates the on-chain measurements against allowable phase-voltage limits derived from the ANSI C84.1 standard. The framework is validated in a hardware-relay-in-the-loop test bed under sustained-undervoltage, sustained-overvoltage, and transient line-to-line fault scenarios. The results show that the VSL smart contract can process these measurements and issue backup breaker actions consistent with the defined service-limit criteria, demonstrating the DLT potential as a verifiable audit layer at the PCC that complements primary protection.

cyber security

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]

Structured Neural Network Modeling for Developing Digital Twins Models of Hydropower Generation Units

Dynamic modeling is a key part in the development of digital twin (DT) for dynamic systems. This is true for hydropower systems, where whole system modeling including penstock, turbine and generators, etc is important in realizing actuate modeling for the real systems. On the other hand, in response to the large variations of the power demand due to increased penetration of renewables such as wind and solar, hydropower systems are now required to operate in a large power generation range. This situation triggers the nonlinear characteristics of the generation unit with respect to its models. As such, it is imperative to use data driven modeling such as neural networks to learn the nonlinear dynamics of the hydropower generation unit. To achieve this objective, this study constructs a modeling and learning algorithm integrated with multiple structured neural network models for the modeling of turbine shaft speed, penstock pressure, and generator power output based on the generator power control setpoint, field current, and field voltage. In addition, the study uses the hydropower data from Tacoma Public Utilities to train and validate the proposed neural network algorithm. The results have shown that this structured neural network modeling approach can learn the system dynamics effectively by using the real-time data collected from the hydropower system with the desired modeling results.

Wang, Hong

Development of an Optical Library for Coevaporated CdSe x Te 1– x

The conversion efficiency of CdTe solar cells may be improved by bandgap engineering, i.e., changing the bandgap value through the addition of Se in the absorber. The Se alloying enables a short-circuit current density improvement, as it leads to a bandgap energy value decrease. Furthermore, it has been associated with increased minority carrier lifetimes, assuring high open-circuit voltage values. An Se gradient profile control can further optimize the solar cell performance. Thus, an optical model baseline of the CdSe x Te 1–x (CST) compound was developed. Spectroscopic ellipsometry measurements were conducted to accurately extract the optical constants of ten CST layers deposited through coevaporation with x varying from 0 to 1. Using the measured dielectric function spectra from the discrete CST layers with varying x, and considering the composition-induced shift in the critical point energies, an energy-shift model was employed to develop the accurate optical library for the CST compound for any x value to provide data for future modeling and optimization. Furthermore, the library accuracy was validated through optical simulations of the quantum efficiency of a graded CST solar cell using the finite-difference time-domain method by replicating the Se profile in the absorber layer measured through secondary ion mass spectrometry.

14 SOLAR ENERGY

Grid Forming Control Tuning for a Hybrid Inverter-Based Resource Power Plant

A hybrid inverter-based resource (IBR) power plant consists of grid-following (GFL) and grid-forming inverter-based resources (GFM-IBR) connected in parallel. Here, this research focuses on how to design and tune GFM's control parameters to ensure stable operation of the hybrid power plant for weak and strong grid conditions. We consider two design cases: one where the GFL-IBR does not provide frequency support, and one where it does. It is found that the GFM's power-frequency synchronizing system can lose stability when the power-frequency droop constant is large and/or the grid is strong. Additionally, if the GFL has its frequency support enabled, oscillation stability worsens. To explain the mechanism of the interactions, we construct a feedback system for the synchronizing loop, which consists of the GFM's power-frequency droop control that generates the GFM's synchronizing angle, the GFL's phase-locked loop that measures the voltage phase angle, the GFL's frequency-power control that generates its power order, and the rest of the system. The feedback system is effective in illustrating the potential stability risks. Successful design ensures that the hybrid power plant can operate smoothly and ride through grid disturbances.

feedback systems

Testing of Participant's Power Electronics Component for Circuit Performance and Efficiency (CRADA Final Report)

The "Solar SEED Smart Controller is a charge control device to condition solar power to load voltage with or without Battery (also called a "DC Power Platform") invented by David Gibbs and T4D Labs Inc. T4D Inc. and the SEED Smart Controller invention were selected for American Made Challenges Solar Prize, which includes voucher for NREL to provide technical assistance.

14 SOLAR ENERGY

Power Module Precursors and Prognostics

This project focuses on finding and utilizing electrical properties (precursors) of power electronic devices and modules whose changes have strong correlations with different modes and levels of degradations in order to realize online and lightweight state of health evaluation and fault diagnosis. Results from this project will contribute to higher safety, reliability, and power density of power electronic components. The approaches mainly include reviewing academic literature and industry practices for state of the art precursor identification and extraction, accelerated life cycles (ALC) of various power modules to create different degradations in-house, and developing techniques for gate-driver-integratable precursor detection circuit. In FY24, the results includes two sets of definitively detected aging precursors (on-state resistance and gate threshold voltage) for two sets of power modules respectively, controlled accelerated lifetime cycling of multiple silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor (MOSFET) modules, and the development and validation of a gate voltage detection system.

ADVANCED PROPULSION SYSTEMS

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION

Advanced Computational Modeling of High-Level Waste Vitrification at the Hanford Site

The U.S. Department of Energy (DOE) has selected vitrification for stabilizing legacy tank waste at the Hanford site, where radioactive waste from plutonium production was historically stored in underground tanks. This waste will be separated into low-activity waste (LAW) and high-level waste (HLW) fractions and processed at the Waste Treatment and Immobilization Plant (WTP). At WTP, glass melters are used for the vitrification of radioactive tank waste, transforming it into a stable borosilicate glass form for safe long-term storage. The melter vessel is constructed from highly durable and heat-resistant materials, where the vitrification process occurs. The main regions that are modeled are the melt pool, plenum, cold cap, riser/discharge chamber, and surrounding structure with insulation layers. Forced convection induced by air bubblers at the base of the melter ensure uniform temperature distribution and provide heat to the cold cap layer. The cold cap is a region of reacting batch feed that floats on top of the molten glass and is where the batch-to-glass reactions occur. Joule heating provided by electrodes mounted along the vertical walls of the melter and immersed directly in the glass, generates the necessary heat for the net endothermic conversion processes that occur in the cold cap. The high temperatures, radioactivity, and opaque nature of the glass prevent direct observation inside the melters. Therefore, computational models are essential for providing insight into factors that affect melter throughput. Thermocouples in the plenum provide operators with plenum temperature measurements. Operational adjustments include bubbling rate, voltage supplied to the electrodes, feed adjustments, and glass removal rate. Different computational fluid dynamics (CFD) models have been developed, each serving a specific purpose. There are CFD models of different scale melters, as well as models that capture the two-phase flow interfaces of rising bubbles in the molten glass or models with a simplified molten glass region so that the surrounding structure and plenum can be feasibly incorporated. Pilot-scale melter models have been developed to serve as validation of the methods employed in the simulation of the full-scale WTP melters. Models incorporating resolved bubbling are used to develop momentum source terms to implement into a single phase, multi-region, steady-state flow model that is being validated by measured process parameters such as glass production rate, voltage, input power, plenum temperatures, etc. The resolved bubbling model uses the multiphase volume of fluid approach to model the system with a high-resolution interface capturing scheme to maintain sharp interfaces between the molten glass and the air phase. The suite of CFD models is continually being improved to incorporate more realistic physics and achieve faster turnaround time. For example, an incremental controller is implemented to automatically adjust electrode voltage within the simulation to a molten glass set point temperature of 1150°C. Newer models feature improved meshes to ensure conformal meshes between regions and eliminate unnecessary mesh refinement in areas that are not of interest (such as boundary layers in offgas ports). Instead of explicitly modeling the structural, refractory, and insulation layers of the melter, a thermal resistance approach is used with published correlations used for boundary conditions. The development of robust and efficient CFD models will be instrumental in enabling the WTP to successfully fulfill its mission of safely stabilizing legacy nuclear waste.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE