Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “versatile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Flexible macrocycles as versatile supports for catalytically active metal clusters

Here we present three structurally diverse clusters stabilised by the same macrocyclic polyphenol; t -butylcalix[8]arene. This work demonstrates the range of conformations the flexible ligand is capable of adopting, highlighting its versatility in metal coordination. In addition, a Ti complex displays activity for the ring-opening polymerisation of lactide

36 MATERIALS SCIENCE↗

Understanding and tuning organocatalysts for versatile condensation polymer deconstruction

Plastics are widely used for their durability and versatility, but recycling remains a major challenge, especially for mixed or contaminated waste. Mechanical recycling works well for clean, single-polymer streams like PET but has limited efficiency for complex waste streams. Chemical recycling, particularly glycolysis, is often employed to selectively deconstruct condensation polymers under mild conditions. This study explores catalyst design for glycolysis using linear free energy (Hammett) analysis to evaluate how catalyst structure influences polymer deconstruction. Polycaprolactone (PCL) is used as a model polyester due to its solubility and low deconstruction temperature. Triazabicyclodecene (TBD) paired with benzoic acid derivatives depicts a clear linear trend in depolymerization rates with Hammett values. TBD with p-aminobenzoic acid (PABA) stands out for its catalytic efficiency, thermal stability, and scalability, along with PABA's commercial availability as vitamin B-10. The TBD : PABA catalyst not only effectively breaks down PCL but also enables sequential deconstruction of polycarbonate, PET, and Nylon in mixed waste streams. These results highlight the value of Hammett-guided catalyst design and establish TBD : PABA as a promising, scalable organocatalyst for mixed plastic recycling, enabling recovery of individual polymer building blocks from blended waste and offering a practical route toward circular plastics.

Zheng, Jackie [Univ. of Tennessee, Knoxville, TN (↗

Phosphatidic acid: an emerging versatile class of cellular mediators

Abstract Lipids function not only as the major structural components of cell membranes, but also as molecular messengers that transduce signals to trigger downstream signaling events in the cell. Phosphatidic acid (PA), the simplest and a minor class of glycerophospholipids, is a key intermediate for the synthesis of membrane and storage lipids, and also plays important roles in mediating diverse cellular and physiological processes in eukaryotes ranging from microbes to mammals and higher plants. PA comprises different molecular species that can act differently, and is found in virtually all organisms, tissues, and organellar membranes, with variations in total content and molecular species composition. The cellular levels of PA are highly dynamic in response to stimuli and multiple enzymatic reactions can mediate its production and degradation. Moreover, its unique physicochemical properties compared with other glycerophospholipids allow PA to influence membrane structure and dynamics, and interact with various proteins. PA has emerged as a class of new lipid mediators modulating various signaling and cellular processes via its versatile effects, such as membrane tethering, conformational changes, and enzymatic activities of target proteins, and vesicular trafficking.

Biochemistry & Molecular Biology↗

PULSION registered: A Versatile 200 to 300 mm Bridge Tool Plasma Immersion Ion Implanter for Ultra-Shallow Doping and Nanotechology Applications

Thanks to the European Projects SEA-NET and PULLNANO, an industrial version of the IBS Plasma Ion Implantation tool has been installed in LETI for the fabrication of Ultra-Shallow Junctions for 45 and 32 nm CMOS on 200 and 300 mm wafers. In this paper, we present the main machine characteristics (layout, contamination, homogeneity, reproducibility, uptime) and we show that implanted wafers are compatible with the 32 nm nodes requirements. Then doping results (sheet resistance vs junction depth and leakage current) using several annealing technics are presented (laser, flash and spike anneals). In the second part of the paper, versatility of the tool is demonstrated with its use for other applications (3D doping, hydrogenation, solar cells...)

36 MATERIALS SCIENCE↗

A versatile electron-ion coincidence spectrometer for photoelectron momentum imaging and threshold spectroscopy on mass selected ions using synchrotron radiation

We present a photoelectron-photoion coincidence (PEPICO) spectrometer named DELICIOUS II which combines a velocity map imaging apparatus with a Wiley-McLaren time of flight analyzer for the study of gas phase samples in interaction with the synchrotron radiation (SR). This versatile system is capable of providing photoelectron images on mass-selected compounds with kinetic energy resolutions of {delta}E/E=5% and a 17 eV bandwidth, as well as threshold photoelectron spectra with a measured resolution of 0.8 meV, as demonstrated on the 3p{sup -1} ionization of argon. This instrument is also employed for threshold PEPICO experiments, allowing the selection of the parent ion's internal state with sub-meV resolution for light masses (<40 amu) and with typically 2 meV resolution for a mass of 100 amu and with a mass resolving power above 200. The continuous operation of the extraction fields and the independence from the electron's time of flight are well adapted to the quasicontinuous multibunch mode of the SR. This, together with the high transmission of both the electron and ion detection, allows a high coincidence counting rate and facilitates the subtraction of false coincidences. We illustrate the spectrometer's coincidence principle of operation with examples from the valence photoionization of an Ar+Xe mixture and of CF{sub 4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of high efficiency Versatile Arc Discharge Ion Source at CERN ISOLDE

We report here recent developments of Forced Electron Beam Induced Arc Discharge (FEBIAD) ion sources at the ISOLDE radioactive ion beam facility, hosted at the European Organization for Nuclear Research (CERN). As a result of the propositions to improve the ionization efficiency, two FEBIAD prototypes have been produced and successfully tested in 2008. Off-line studies showed that the 1+ ionization efficiencies for noble gases are 5-20 times larger than with the standard ISOLDE FEBIAD ion sources and reach 60% for radon, which allowed the identification at ISOLDE of {sup 229}Rn, an isotope that had never previously been observed in the laboratory. A factor of 3 increase is also expected for the ionization efficiency of the other elements. The experimental and theoretical methodology is presented. The theoretical model, which gives precise insights on the processes affecting the ionization, is used to design optimal sources (grouped under the name of VADIS - Versatile Arc Discharge Ion Source) for the different chemical classes of the produced isotopes, as already demonstrated for the noble gases.

43 PARTICLE ACCELERATORS↗

Plasma wave simulation based on versatile FEM solver on Alcator C-mod

The finite element method (FEM) has the potential of simulating plasma waves seamlessly from the core to the vacuum and antenna regions. We explored the possibility of using a versatile FEM solver package, COMSOL, for lower hybrid (LH) wave simulation. Special care was paid to boundary conditions to satisfy toroidal symmetry. The non-trivial issue of introducing hot plasma effects was addressed by an iterative algorithm. These techniques are verified both analytically and numerically. In the lower hybrid (LH) grill antenna coupling problem, the FEM solver successfully reproduced the solution that was obtained analytically. Propagation of LH waves on the Alcator C and Alcator C-MOD plasmas was compared with a ray-tracing code, showing good consistency. The approach based on the FEM is computationally less intensive compared to spectral domain solvers, and more suitable for the simulation of larger device such as ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Versatile Multilayer Polarimeter for the Soft X-Ray Region

As modern undulators can generate light with arbitrary polarization states, experiments exploiting this feature in the range of soft x-rays have become increasingly widespread. For the success of these experiments characterising the polarization at the sample position is vital. Therefore a versatile, multi-purpose, UHV compatible, multilayer polarimeter has been designed and developed for measuring the Stokes vector of a soft x-ray beam. This high-precision, ultra high vacuum compatible instrument is supported by a Hexapod to simplify its alignment. Furthermore, the instrument has its own independent control system and has been designed for portability so that it can be moved with relative ease between different synchrotron facilities. The polarization analysis requires the rotation of a phase retarder and a polarization analyser, both about a common axis of the photon beam. The polarimeter employs reflection / transmission multilayers as phase retarders / analysers. Several sets of multilayers are installed inside the UHV chamber so that they may be exchanged in-situ without breaking the vacuum. The polarimeter doubles-up as a reflectometer / ellipsometer that enable determination of the polarization properties of optical elements including multilayers with very small surface roughness and several hundred bi-layers. The design details of the polarimeter and the results of first experiments to characterise the polarization of a beamline will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BioRef: A versatile time-of-flight reflectometer for soft matter applications at Helmholtz-Zentrum Berlin

BioRef is a versatile novel time-of-flight reflectometer featuring a sample environment for in situ infrared spectroscopy at the reactor neutron source BER II of the Helmholtz Zentrum Berlin fuer Materialien und Energie (HZB). After two years of design and construction phase the instrument has recently undergone commissioning and is now available for specular and off-specular neutron reflectivity measurements. BioRef is especially dedicated to the investigation of soft matter systems and studies at the solid-liquid interface. Due to flexible resolution modes and variable addressable wavelength bands that allow for focusing onto a selected scattering vector range, BioRef enables a broad range of surface and interface investigations and even kinetic studies with subsecond time resolution. The instrumental settings can be tailored to the specific requirements of a wide range of applications. The performance is demonstrated by several reference measurements, and the unique option of in situ on-board infrared spectroscopy is illustrated by the example of a phase transition study in a lipid multilayer film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Electronics For The Versatile Array Of Neutron Detectors At Low Energies

A {chi}{sup 2} minimization algorithm has been developed to extract sub-sampling-time information from digitized waveforms, to be used to instrument the future Versatile Array of Neutron Detectors at Low energies. The algorithm performance has been characterized with a fast Arbitrary Function Generator, obtaining time resolution better than 1 ns for signals of amplitudes between 50 mV and 1V, with negligible walk in the whole range. The proof-of-principle measurement of the beta-delayed neutron emission from {sup 89}Br indicates a resolution of 1 ns can be achieved in realistic experimental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the versatile ion source and possible applications as injector for future projects

The versatile ion source (VIS) is an off-resonance microwave discharge ion source which generates a slightly overdense plasma (n{sub e}{approx_equal} 10{sup 17} cm{sup -3}) operating at 2.45 GHz and producing more than 50 mA of proton beams. A detailed characterization of the source, by operating between 60 and 75 kV, in terms of emittance, current extracted and proton fraction is reported below. Moreover, passive techniques (alumina coating of the plasma chamber walls, BN disks at the injection and extraction endplates) have been used to improve the performance of the source, increasing the electron density for a more efficient ionization. The know-how achieved with the VIS source may be useful for the different project, particularly for the European spallation source.

43 PARTICLE ACCELERATORS↗

Development of a versatile multiaperture negative ion source

A 60 kV ion source (9 beamlets of 15 mA each of H{sup -}) and plasma generators are being developed at Consorzio RFX and INFN-LNL, for their versatility in experimental campaigns and for training. Unlike most experimental sources, the design aimed at continuous operation. Magnetic configuration can achieve a minimum |B| trap, smoothly merged with the extraction filter. Modular design allows for quick substitution and upgrading of parts such as the extraction and postacceleration grids or the electrodes in contact with plasma. Experiments with a radio frequency plasma generator and Faraday cage inside the plasma are also described.

43 PARTICLE ACCELERATORS↗

Versatile shaping of a relativistic laser pulse from a nonuniform overdense plasma

We studied the versatile shaping of a petawatt laser pulse using its relativistic transparency in a thin overdense plasma slab. The novel concept here is to use the nonuniformity of the plasma slab in its density or thickness in the transverse direction to control the pulse shaping in both the longitudinal and transverse directions. From 2-dimensional particle-in-cell simulations, we succeeded in fabricating a front shape concave to the propagation direction, an extreme case of transverse shaping. A 1-dimensional analytic formula was then applied to predict the transverse shape, which showed good agreement with the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A versatile detector for total fluorescence and electron yield experiments

The combination of a non-coated silicon photodiode with electron repelling meshes makes a versatile detector for total fluorescence yield and electron yield techniques highly suitable for x-ray absorption spectroscopy. In particular, a copper mesh with a bias voltage allows to suppress or transmit the electron yield signal. The performance of this detection scheme has been characterized by near edge x-ray absorption fine structure studies of thermal oxidized silicon and sapphire. The results show that the new detector probes both electron yield and for a bias voltage exceeding the maximum photon energy the total fluorescence yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FLUTE: A versatile linac-based THz source

A new compact versatile linear accelerator named FLUTE is currently being designed at the Karlsruhe Institute of Technology. This paper presents the status of this 42 MeV machine. It will be used to generate strong (several 100 MV/m) ultra-short ({approx}1 ps) THz pulses (up to {approx}4-25 THz) for photon science experiments, as well as to conduct a variety of accelerator studies. The latter range from comparing different coherent THz radiation generation schemes to compressing electron bunches and studying the electron beam stability. The bunch charge will cover a wide range ({approx}100 pC-3 nC). Later we plan to also produce ultra-short x-ray pulses from the electron bunches, which, for example, could then be combined for THz pump-x-ray probe experiments.

43 PARTICLE ACCELERATORS↗

Versatile plug flow catalytic cell for in situ transmission/fluorescence x-ray absorption fine structure measurements

A novel flow-through catalytic cell has been developed for in situ x-ray absorption spectroscopy (XAS) experiments on heterogeneous catalysts under working conditions and in the presence of a liquid and a gas phase. The apparatus allows to carry out XAS measurements in both the transmission and fluorescence modes, at moderate temperature (from RT to 50-80 Degree-Sign C) and low-medium gas pressure (up to 7-8 bars). The materials employed are compatible with several chemicals such as those involved in the direct synthesis of hydrogen peroxide (O{sub 2}, H{sub 2}, H{sub 2}O{sub 2}, methanol). The versatile design of the cell allows to fit it to different experimental setups in synchrotron radiation beamlines. It was used successfully for the first time to test nanostructured Pd catalysts during the direct synthesis of hydrogen peroxide (H{sub 2}O{sub 2}) in methanol solution from dihydrogen and dioxygen.

36 MATERIALS SCIENCE↗

A versatile ultra high vacuum sample stage with six degrees of freedom

We describe the design and practical realization of a versatile sample stage with six degrees of freedom. The stage was designed for use in a Low Energy Electron Microscope, but its basic design features will be useful for numerous other applications. The degrees of freedom are X, Y, and Z, two tilts, and azimuth. All motions are actuated in an ultrahigh vacuum base pressure environment by piezoelectric transducers with integrated position sensors. The sample can be load-locked. During observation, the sample is held at a potential of −15 kV, at temperatures between room temperature and 1500 °C, and in background gas pressures up to 1 × 10{sup −4} Torr.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A versatile elevated-pressure reactor combined with an ultrahigh vacuum surface setup for efficient testing of model and powder catalysts under clean gas-phase conditions

A small-volume reaction cell for catalytic or photocatalytic testing of solid materials at pressures up to 1000 Torr has been coupled to a surface-science setup used for standard sample preparation and characterization under ultrahigh vacuum (UHV). The reactor and sample holder designs allow easy sample transfer from/to the UHV chamber, and investigation of both planar and small amounts of powder catalysts under the same conditions. The sample is heated with an infrared laser beam and its temperature is measured with a compact pyrometer. Combined in a regulation loop, this system ensures fast and accurate temperature control as well as clean heating. The reaction products are automatically sampled and analyzed by mass spectrometry and/or gas chromatography (GC). Unlike previous systems, our GC apparatus does not use a recirculation loop and allows working in clean conditions at pressures as low as 1 Torr while detecting partial pressures smaller than 10{sup −4} Torr. The efficiency and versatility of the reactor are demonstrated in the study of two catalytic systems: butadiene hydrogenation on Pd(100) and CO oxidation over an AuRh/TiO{sub 2} powder catalyst.

36 MATERIALS SCIENCE↗