Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Current ISS Exercise Countermeasures: Where are we now?

Current International Space Station (ISS) crew schedules include 1.5 h/d for completion of resistive exercise and 1 h/d of aerobic exercise , 6 d/wk. While ISS post flight decrements in muscle strength, bone m ineral density, and aerobic capacity improved in some crewmembers, de conditioning was still evident even with this volume of exercise. Res ults from early ISS expeditions show maximum loss in bone mineral density of the lumbar spine and pelvis in excess of 1.5% per month, with all crewmembers demonstrating significant bone loss in one or more re gions. Similarly, post flight muscle strength losses in the hamstring and quadriceps muscle groups exceeded 30% in the immediate post miss ion period in some crewmembers. Measures of aerobic capacity early in the mission show average decrements of 15%, but with onboard aerobic exercise capability, the crew has been able to "train up" over the co urse of the mission. These findings are highly variable among crewmem bers and appear to be correlated with availability and reliability of the inflight resistive exercise device (RED), cycle ergometer, and t readmill. This suite of hardware was installed on ISS with limited op erational evaluation in groundbased test beds. As a result, onorbit hardware constraints have resulted in inadequate physical stimulus, d econditioning, and increased risk for compromised performance during intra and extravehicular activities. These issues indicate that the c urrent ISS Countermeasures System reliability or validity are not ade quate for extendedduration exploration missions. Learning Objective: A better understanding of the status of ISS exercise countermeasures , their ability to protect physiologic systems, and recommendations for exploration exercise countermeasures.

Hayes, J. C.↗

Analysis and Design of Variable Stiffness Composite Cylinders

An investigation of the possible performance improvements of thin circular cylindrical shells through the use of the variable stiffness concept is presented. The variable stiffness concept implies that the stiffness parameters change spatially throughout the structure. This situation is achieved mainly through the use of curvilinear fibers within a fiber-reinforced composite laminate, though the possibility of thickness variations and discrete stiffening elements is also allowed. These three mechanisms are incorporated into the constitutive laws for thin shells through the use of Classical Lamination Theory. The existence of stiffness variation within the structure warrants a formulation of the static equilibrium equations from the most basic principles. The governing equations include sufficient detail to correctly model several types of nonlinearity, including the formation of a nonlinear shell boundary layer as well as the Brazier effect due to nonlinear bending of long cylinders. Stress analysis and initial buckling estimates are formulated for a general variable stiffness cylinder. Results and comparisons for several simplifications of these highly complex governing equations are presented so that the ensuing numerical solutions are considered reliable and efficient enough for in-depth optimization studies. Four distinct cases of loading and stiffness variation are chosen to investigate possible areas of improvement that the variable stiffness concept may offer over traditional constant stiffness and/or stiffened structures. The initial investigation deals with the simplest solution for cylindrical shells in which all quantities are constant around the circumference of the cylinder. This axisymmetric case includes a stiffness variation exclusively in the axial direction, and the only pertinent loading scenarios include constant loads of axial compression, pressure, and torsion. The results for these cases indicate that little improvement over traditional laminates exists through the use of curvilinear fibers, mainly due to the presence of a weak link area within the stiffness variation that limits the ultimate load that the structure can withstand. Rigorous optimization studies reveal that even though slight increases in the critical loads can be produced for designs with an arbitrary variation of the fiber orientation angle, the improvements are not significant when compared to traditional design techniques that utilize ring stiffeners and frames. The second problem that is studied involves arbitrary loading of a cylinder with a stiffness variation that changes only in the circumferential direction. The end effects of the cylinder are ignored, so that the problem takes the form of an analysis of a cross-section for a short cylinder segment. Various load cases including axial compression, pressure, torsion, bending, and transverse shear forces are investigated. It is found that the most significant improvements in load-carrying capability exist for cases which involve loads that also vary around the circumference of the shell, namely bending and shear forces. The stiffness variation of the optimal designs contribute to the increased performance in two ways: lowering the stresses in the critical areas through redistribution of the stresses; and providing a relatively stiff region that alters the buckling behavior of the structure. These results lead to an in-depth optimization study involving weight optimization of a fuselage structure subjected to typical design constraints. Comparisons of the curvilinear fiber format to traditional stiffened structures constructed of isotropic and composite materials are included. It is found that standard variable stiffness designs are quite comparable in terms of weight and load-carrying capability yet offer the added advantage of tailorability of distinct regions of the structure that experience drastically different loading conditions. The last two problems presented in this work involve the nonlinear phenomenon of long tubes under bending. Though this scenario is not as applicable to fuselage structures as the previous problems, the mechanisms that produce the nonlinear effect are ideally suited to be controlled by the variable stiffness concept. This is due to the fact that the dominating influence for long cylinders under bending is the ovalization of the cross-section, which is governed mainly by the stiffness parameters of the cylindrical shell. Possible improvement of the critical buckling moments for these structures is investigated using either a circumferential or axial stiffness variation. For the circumferential case involving infinite length cylinders, it is found that slight improvements can be observed by designing structures that resist the cross-sectional deformation yet do not detract from the buckling resistance at the critical location. The results also indicate that buckling behavior is extremely dependent on cylinder length. This effect is most easily seen in the solution of finite length cylinders under bending that contain an axial stiffness variation. For these structures, the only mechanism that exhibits improved response are those that effectively shorten the length of the cylinder, thus reducing the cross-sectional deformation due to the forced restraint at the ends. It was found that the use of curvilinear fibers was not able to achieve this effect in sufficient degree to resist the deformation, but that ring stiffeners produced the desired response admirably. Thus, it is shown that the variable stiffness concept is most effective at improving the bending response of long cylinders through the use of a circumferential stiffness variation.

Tatting, Brian F.↗

Thermal Vacuum Testing of a Novel Loop Heat Pipe Design for the Swift BAT Instrument

An advanced thermal control system for the Burst Alert Telescope on the Swift satellite has been designed and an engineering test unit (ETU) has been built and tested in a thermal vacuum chamber. The ETU assembly consists of a propylene loop heat pipe, two constant conductance heat pipes, a variable conductance heat pipe (VCHP), which is used for rough temperature control of the system, and a radiator. The entire assembly was tested in a thermal vacuum chamber at NASA/GSFC in early 2002. Tests were performed with thermal mass to represent the instrument and with electrical resistance heaters providing the heat to be transferred. Start-up and heat transfer of over 300 W was demonstrated with both steady and variable condenser sink temperatures. Radiator sink temperatures ranged from a high of approximately 273 K, to a low of approximately 83 K, and the system was held at a constant operating temperature of 278 K throughout most of the testing. A novel LHP temperature control methodology using both temperature-controlled electrical resistance heaters and a small VCHP was demonstrated. This paper describes the system and the tests performed and includes a discussion of the test results.

Ottenstein, Laura↗

Application of high-alpha control system concepts to a variable-sweep fighter airplane

The use of control system design to enhance high-angle-of-attack flying qualities and departure/spin resistance has become an accepted and widely used approach for modern fighter aircraft. NASA and the Navy are currently conducting a joint research program to investigate the application of this technology to the F-14. The paper discusses the results of this program within the context of its contributions to advancing high-alpha control system technology. General topics covered include (1) analysis and design tools, (2) control system design approach, and (3) flight test approach and results.

Nguyen, L. T.↗

Environmental fatigue of an Al-Li-Cu alloy. Part 1: Intrinsic crack propagation kinetics in hydrogenous environments

Deleterious environmental effects on steady-state, intrinsic fatigue crack propagation (FCP) rates (da/dN) in peak aged Al-Li-Cu alloy 2090 are established by electrical potential monitoring of short cracks with programmed constant delta K and K(sub max) loading. The da/dN are equally unaffected by vacuum, purified helium, and oxygen but are accelerated in order of decreasing effectiveness by aqueous 1 percent NaCl with anodic polarization, pure water vapor, moist air, and NaCl with cathodic polarization. While da/dN depends on delta K(sup 4.0) for the inert gases, water vapor and chloride induced multiple power-laws, and a transition growth rate 'plateau'. Environmental effects are strongest at low delta K. Crack tip damage is ascribed to hydrogen embrittlement because of the following: (1) accelerated da/dN due to part-per-million levels of H2O without condensation; (2) impeded molecular flow model predictions of the measured water vapor pressure dependence of da/dN as affected by mean crack opening; (3) the lack of an effect of film-forming O2; (4) the likelihood for crack tip hydrogen production in NaCl, and (5) the environmental and delta K-process zone volume dependencies of the microscopic cracking modes. For NaCl, growth rates decrease with decreasing loading frequency, with the addition of passivating Li2CO3, and upon cathodic polarization. These variables increase crack surface film stability to reduce hydrogen entry efficiency. The hydrogen environmental FCP resistance of 2090 is similar to other 2000 series alloys and is better than 7075.

Piascik, Robert S.↗

Environmental fatigue of an Al-Li-Cu alloy. I - Intrinsic crack propagation kinetics in hydrogenous environments

Deleterious environmental effects on steady-state, intrinsic fatigue crack propagation (FCP) rates (da/dN) in peak aged Al-Li-Cu alloy 2090 are established by electrical potential monitoring of short cracks with programmed constant delta K and K(sub max) loading. The da/dN are equally unaffected by vacuum, purified helium, and oxygen but are accelerated in order of decreasing effectiveness of aqueous 1 percent NaCl with anodic polarization, pure water vapor, moist air, and NaCl with cathodic polarization. While da/dN depends on delta K(sup 4.0) for the inert gases, water vapor and chloride induced multiple power-laws, and a transition growth rate 'plateau'. Environmental effects are strongest at low delta K. Crack tip damage is ascribed to hydrogen embrittlement because of the following: (1) accelerated da/dN due to part-per-million levels of H2O without condensation; (2) impeded molecular flow model predictions of the measured water vapor pressure dependence of da/dN as affected by mean crack opening; (3) the lack of an effect of film-forming O2; (4) the likelihood for crack tip hydrogen production in NaCl; and (5) the environmental and delta K-process zone volume dependencies of the microscopic cracking modes. For NaCl, growth rates decrease with decreasing loading frequency, with the addition of passivating Li2CO3, and upon cathodic polarization. These variables increase crack surface film stability to reduce hydrogen entry efficiency. The hydrogen environmental FCP resistance of 2090 is similar to other 2000 series alloys and is better than 7075.

Piascik, Robert S.↗

Differences in Acceleration Training and Exercise Training on Resting Cardiovascular Variables

The relative effects of alternating exercise vs. acclamation training an mean blood pressure (BP, Finapres), cardiac output (CO, BoMed) and peripheral resistance (PR, calculated) were evaluated. Six healthy men (33$\pm$(SD)6 yr. 178$\pm$4 cm, 86$\pm$6 kg) underwent exercise training (ET, n=3): supine on a cycle ergometer (40 to 90\% Vo$_{2}$ max) during exposure to constant+1G$_{z}$ for $\sim$30 min/day for 14 days on NASA's 1.9m Human Powered Centrifuge (HPC). They also underwent oscillatory (between +1 G$ {z}$and$\sim$2.5G$_{z}$) acceleration training (AT, n=3) for $\sim$30 min/day for 14 days on the HPC. After four weeks of ambulatory deconditioning, training protocols were switched. AT increased resting CO by 9.MpmS(SE)3.2\% (p$less than$0.05) with no effect on BF, and ET decreased BP by 9.2$\pm$4.6\% (p$less than$0.08) as well as spectral power of PR by 41$\pm$9\% (p$less than$0.05). The major effect of acceleration training was to increase resting cardiac output while that of exercise mining was to decrease resting blood pressure.

Evans, J. M.↗

Augmented baroreflex heart rate gain after moderate-intensity, dynamic exercise

The occurrence of a sustained vasodilation and hypotension after acute, dynamic exercise suggests that exercise may alter arterial baroreflex mechanisms. Therefore, we assessed systemic hemodynamics, baroreflex regulation of heart rate, and cardiac vagal tone after 60 min of cycling at 60% peak oxygen consumption in 12 healthy, untrained men and women (ages 21-28 yr). We derived sigmoidal carotid-cardiac baroreflex relations by measurement of R-R interval changes induced by ramped, stepwise, R-wave-triggered changes in external neck pressure from 40 to -65 mmHg. We estimated tonic cardiac vagal control with power spectral analysis of R-R interval variability in the respiratory frequency band (0.2-0.3 Hz) during frequency- and tidal volume-controlled breathing. Both mean arterial pressure and total peripheral resistance were reduced postexercise [pressure: from 86 +/- 2 (mean +/- SE) to 81 +/- 2 mmHg; resistance: from 23 +/- 2 to 16 +/- 1 units; both P < 0.05]. Cardiac output was increased postexercise (from 3.9 +/- 0.3 to 5.5 +/- 0.5 l/min, P < 0.05). Both slope and range of the carotid-cardiac baroreflex relation were increased postexercise (slope: from 4.7 +/- 0.7 to 6.1 +/- 0.9 ms/mmHg; range: from 186 +/- 23 to 238 +/- 30 ms, P < 0.05). Respiratory R-R interval variability (cardiac vagal tone) was not changed at any time after exercise, whereas heart rate and plasma norepinephrine levels were elevated. Thus moderate-intensity, dynamic exercise increases heart rate and cardiac output, reduces peripheral vascular resistance, and augments baroreflex responsiveness. Our data suggest that augmented baroreflex heart rate gain restrains rather than contributes to postexercise hypotension, which appears to be mediated predominately by vasodilation.

NASA Discipline Cardiopulmonary↗

Vapor-modulated heat pipe report. Flight data analysis and further development of variable-conductance heat pipes

The design and testing of a heat pipe for spacecraft application is presented. The application in mind calls for heat loads up to 20 watts, a set-point temperature of 294K, and a sink that varies from -220K to nearly as high as the set-point. The overall heat pipe length is 137 cm. Two basically different mechanisms of achieving variable conductance in the pipe by vapor-flow throttling were studied. In one, the thermal resistance between the heat source and sink is due to a saturation-temperature drop corresponding to the vapor-pressure drop developed across the valve. In the other, the pressure difference across the valve induces capillary groove and wick dry out in an evaporation region, and thus results in an increased thermal resistance. This mechanism was selected for fabrication and testing. The pipe is a stainless-steel/methanol two-heat-pipe system. Results are presented and discussed. Engineering drawings and specifications of the pipe are shown.

Eninger, J. E.↗

Influence of design variables on radiation hardness of silicon MINP solar cells

Metal-insulator-N/P silicon (MINP) solar cells were fabricated using different substrate resistivity values, different N-layer designs, and different I-layer designs. A shallow junction into an 0.3 ohm-cm substrate gave best efficiency whereas a deeper junction into a 1 to 4 ohm-cm substrate gave improved radiation hardness. I-layer design variation did little to influence radiation hardness.

Anderson, W. A.↗

Effect of upright tilt on ventricular/vascular coupling in chronically instrumented primates

Studies of the hydraulic loading conditions on the heart in humans, especially pulsatile load, have primarily been limited to the supine state. Therefore, we have chosen a nonhuman primate model, the baboon, to assess left ventricular/vascular coupling in both supine and upright positions. Primate subjects were studied by catheterization under sedation and then after surgical implantation of transducers. This allowed the evaluation of postural stress in the chronically instrumented conscious baboon and then after light dissociative doses of ketamine. Basic hemodynamic variables were evaluated for baboons in supine and upright positions. Fourier analysis was applied to aortic pressure and flow to obtain input and characteristic impedance and the ratio of pulsatile (Wp) to total (Wt) left ventricular power (Wp/Wt). The aortic reflected, or backward, pressure was also calculated. Peripheral resistance increased (P = 0.01) and reflected pressure decreased (17.74 +/- 1.50 vs. 15.21 +/- 2 mmHg; P < 0.01) in upright subjects. Characteristic impedance and Wp/Wt were unchanged. Postoperatively, peripheral resistance increased (2,651 +/- 311 vs. 3,667 +/- 276; P < 0.05) and mean power and Wt decreased (P < 0.01) without changes in reflected pressure. All variables were unchanged after light dissociative doses of ketamine. Thus there is no significant change in efficiency of left ventricular/vascular coupling formulated in terms of Wp/Wt or input impedance with postural stress.

NASA Program Space Physiology and Countermeasures↗

Acoustic Panel Liner for an Engine Nacelle

An acoustic panel liner includes a face sheet, back plate, and liner core positioned there-between, which may be used in an engine nacelle. Elongated chambers contain variable amounts of septa at a calibrated depth or depths. The septa may have varying DC flow resistance. The chambers may have a hexagonal or other polygonal cross sections. The septa, such as mesh caps, may be bonded to an inner wall of a corresponding chamber. The insertion depths may be the same or different. If different, the pattern of distribution of the depths may be randomized.

Jones, Michael G.↗

Impact of Powder Variability on the Microstructure and Mechanical Behavior of Selective Laser Melted (SLM) Alloy 718

Nickel Alloy 718 has found wide use in high-temperature aerospace applications (up to 700°C), due to a combination of good mechanical properties, environmental resistance, and workability at moderate cost. These properties have led Alloy 718 to early adoption by selective laser melting (SLM) additive manufacturing. This presentation will share results from a comprehensive industry survey of 718 powder feedstock for SLM. The survey focuses on the impact of variability in powder characteristics on build quality, microstructure, tensile and high cycle fatigue in the as-fabricated and machined surface conditions. The investigation includes sixteen powder lots from eight suppliers that are produced by gas atomization or rotary atomization in argon or nitrogen. This research was previously presented and published at the 9th International Symposium on Superalloy 718 & Derivatives and was funded by NASA Space Launch System Liquid Engine Office with the Human Exploration Operations Mission Directorate.

Sudbrack, Chantal↗

Thermal conductivity of austenitic stainless steel, SRM 735, from 5 to 280 K

Thermal conductivity and electrical resistivity measurements were conducted on two lots of an austenitic stainless steel. Electrical resistivity measurements were performed on the second lot, both before and after the material was hot-swaged and reannealed to a size 1/10 the original diameter. These measurements indicate that this steel can be swaged and reannealed without an appreciable change in thermal conductivity. Electrical resistivity measurements as well as direct thermal conductivity measurements on several specimens from both lots indicate a material variability in these lots of less than 1% in thermal conductivity.

Hust, J. G.↗

A miniature fatigue test machine

The objective is to enable the student to generate statistically sound fatigue data sets on wire specimens of varying diameter, microstructure, or material. The student can then assess the effect of these parameters of fatigue resistance. The student can also be exposed to ASTM techniques for fatigue data reduction and presentation. Experiments involving variable amplitude block loading are also easily conducted.

Tipton, Steven M.↗

Intensive Exercise Training During Bed Rest Attenuates Deconditioning

Intensive exercise training during bed rest attenuates deconditioning. Med. Sci. Sports Exerc., Vol. 29, No. 2, pp. 207-215, 1997. A 30-d 6 deg head-down bed rest project was conducted to evaluate variable high-intensity, short-duration, isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent resistive isokinetic exercise (IKE) training regimens designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (adaptive) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Major findings are summarized in this paper. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volumes, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (f) attenuated the decrease in peak VO2 by 50%, (g) attenuated loss of red cell volume by 40% but had no effect on loss of plasma volume, (b) induced positive body water balance, (i) had no adverse effect on quality of sleep or concentration, and 0) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regimens and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.

Greenleaf, John E.↗

Microstructural, Strength, and Creep Characterization of Sylramic™, Sylramic™-iBN and Super Sylramic™-iBN SiC Fibers

The chemical composition, microstructure, strength, and thermal stability of polymer-derived Sylramic™ SiC fibers fabricated by Dow Corning and COI Ceramics, Inc., and nitrogen-treated Sylramic™ SiC fibers, referred to as Sylramic™-iBN and Super Sylramic™-iBN SiC fibers, were investigated and compared. The baseline Sylramic™ SiC fibers fabricated by both vendors as well as the nitrogen-treated Sylramic™ SiC fibers are composed mostly of β-SiC (~97 wt%) with small amounts of TiB2 (~2 wt%), amorphous carbon (~1 wt%) and trace amounts of B4C. Most of the amorphous carbon is segregated at the core/interior of the fibers. Both baseline and nitrogen-treated Sylramic™ SiC fibers have similar grain size and pore size distribution, except for a thin layer of in-situ grown crystalline BN (30 to 70 nm) on the surface of Sylramic™-iBN and Super Sylramic™-iBN fibers. Wide variation in strength within a batch as well as between batches is observed in both baseline and nitrogen-treated Sylramic™ SiC fibers but both types of fibers are microstructurally stable at temperatures to 1800°C in argon and nitrogen environments compared to Nicalon™-S and Tyranno®-SA SiC fibers. Under the same creep condition, Super Sylramic™-iBN fibers show better creep resistance compared to Sylramic™, Sylramic™-iBN, Hi-Nicalon™-S, and Tyranno®-SA fibers. Possible reasons for strength variability and the mechanism of in-situ BN formation on Sylramic™ SiC fibers are discussed.

SiC fibers↗

Influence of evaporation rate and chamber pressure on the FUV reflectance and physical characteristics of aluminum films

Space telescopes for studying astrophysical phenomena from the far ultraviolet (FUV) to the near infrared (NIR) require durable mirror coatings with high and uniform reflectance over a very broad spectral region. While coatings for the optical and NIR region are well developed with proven performance, the FUV band presents significant challenges, particularly below 115 nm. Recent developments in physical vapor deposition (PVD) coating processes of aluminum mirrors that are protected with a metal-fluoride overcoat to prevent oxidation (such as LiF, MgF2, or AlF3) have improved reflectance in the FUV. While the emphasis in these studies has been placed on improving the deposition conditions of the metal-fluoride overcoats, less attention has been devoted to how deposition parameters (such as vacuum conditions or deposition rates) may affect the quality of the aluminum mirrors. This paper presents characterization of Al+MgF2 coupons made by flash evaporation of aluminum followed by resistive evaporation of MgF2. Samples were manufactured under a variety of processing conditions and the relationship between processing variables and mirror FUV reflectivity is analyzed. Performance characterization was based on the measured near-normal reflectance in the FUV (90-180 nm), and normal-incidence transmittance in the visible was done to analyze the possible presence of pinholes in the mirror. We demonstrated pinhole-free Al/MgF2 mirrors deposited at room temperature with a reflectivity of 0.91 at 122 nm wavelength. This reflectivity enhancement was achieved solely through parameter optimization.

Manuel A. Quijada↗