Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In vivo nuclear magnetic resonance imaging

A number of physiological changes have been demonstrated in bone, muscle and blood after exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long duration space missions is an important NASA goal. The advent of tomographic nuclear magnetic resonance imaging (NMR or MRI) gives NASA a way to greatly extend early studies of this phenomena in ways not previously possible; NMR is also noninvasive and safe. NMR provides both superb anatomical images for volume assessments of individual organs and quantification of chemical/physical changes induced in the examined tissues. The feasibility of NMR as a tool for human physiological research as it is affected by microgravity is demonstrated. The animal studies employed the rear limb suspended rat as a model of mucle atrophy that results from microgravity. And bedrest of normal male subjects was used to simulate the effects of microgravity on bone and muscle.

Leblanc, A.↗

Hybrid-dual-fourier tomographic algorithm for a fast three-dimensionial optical image reconstruction in turbid media

A reconstruction technique for reducing computation burden in the 3D image processes, wherein the reconstruction procedure comprises an inverse and a forward model. The inverse model uses a hybrid dual Fourier algorithm that combines a 2D Fourier inversion with a 1D matrix inversion to thereby provide high-speed inverse computations. The inverse algorithm uses a hybrid transfer to provide fast Fourier inversion for data of multiple sources and multiple detectors. The forward model is based on an analytical cumulant solution of a radiative transfer equation. The accurate analytical form of the solution to the radiative transfer equation provides an efficient formalism for fast computation of the forward model.

Alfano, Robert R.↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

Single scan operation of television X-ray fluoroscopic systems allow both analog and digital reconstruction of tomographic sections from single plan images. This type of system combined with a minimum of statistical processing showed excellent capabilities for delineating small changes in differential X-ray attenuation. Patient dose reduction is significant when compared to normal operation or film recording. Flat screen, low light level systems were both rugged and light in weight, making them applicable for a variety of special purposes. Three dimensional information was available from the tomographic methods and the recorded data was sufficient when used with appropriate computer display devices to give representative 3D images.

Baily, N. A.↗

Optical Imaging Methods for Volumetric Additive Manufacturing

Tomographic volumetric additive manufacturing (VAM) is a technique that enables light-induced curing of photoresins into complex 3D end use objects within a single step. This is made possible through projecting tomographically patterned light energy into a photo-curable resin volume within a rotating container. In order to monitor, quantify, and control curing during tomographic VAM, researchers need to visualize the curing parts in real-time. This may enable advancements toward dynamic, controlled and closedloop VAM methods in the future, as some researchers have shown. Herein we briefly review various optical imaging methods used to monitor printing in real-time, as well as provide some perspectives for future needs and considerations for imaging methods in VAM.

36 MATERIALS SCIENCE↗

CodEx: A Modular Framework for Joint Temporal De-Blurring and Tomographic Reconstruction

In many computed tomography (CT) imaging applications, it is important to rapidly collect data from an object that is moving or changing with time. Tomographic acquisition is generally assumed to be step-and-shoot, where the object is rotated to each desired angle, and a view is taken. However, step-and-shoot acquisition is slow and can waste photons, so in practice fly-scanning is done where the object is continuously rotated while collecting data. However, this can result in motion-blurred views and consequently reconstructions with severe motion artifacts. In this paper, we introduce CodEx, a modular framework for joint de-blurring and tomographic reconstruction that can effectively invert the motion blur introduced in sparse view fly-scanning. The method is a synergistic combination of a novel acquisition method with a novel non-convex Bayesian reconstruction algorithm. CodEx works by encoding the acquisition with a known binary code that the reconstruction algorithm then inverts. Using a well chosen binary code to encode the measurements can improve the accuracy of the inversion process. The CodEx reconstruction method uses the alternating direction method of multipliers (ADMM) to split the inverse problem into iterative deblurring and reconstruction sub-problems, making reconstruction practical to implement. Here we present reconstruction results on both simulated and binned experimental data to demonstrate the effectiveness of our method.

42 ENGINEERING↗

From irregular to regular eutectic growth in the Al-Al 3 Ni system: In situ observations during directional solidification

Here we investigate the irregular eutectic growth dynamics of the Al-Al 3 Ni alloy, in which one of the solid phases (Al 3 Ni) grows faceted from the liquid. Leveraging in situ optical microscopy and synchrotron transmission x-ray microscopy, we address the question of the degree of coupling between Al and Al 3 Ni at the growth front and that of the shape of the microstructures left behind in the bulk solid during directional solidification. Real-time optical observations bring evidence for a morphological transition from a eutectic-grain dependent, irregular eutectic growth at low solidification velocity V (typically 1 μm s -1 ), to a weakly anisotropic, regular growth at higher V ( reaching 10 μm s -1 ). Unprecedented x-ray nano-imaging of the solid–liquid interface, and 3D characterization of the growth patterns, were made possible by a new DS setup at Brookhaven National Laboratory’s NSLS-II. At low V, the leading tips of partly faceted Al 3 Ni crystals are observed to grow not far ahead of the Al growth front. Correlating in situ images and postmortem 3D tomographic reconstructions reveals that the presence of faceted and non-faceted regions of Al 3 Ni crystals in the solid is a direct consequence of coupling and decoupling during DS, respectively. Upon increasing V, the lead distance of Al 3 Ni vanishes, and the shape of Al 3 Ni ceases to be governed by faceted growth. These observations cast light onto the basic mechanisms (faceted growth, diffusive coupling, and the dynamics of trijunctions) governing a faceted to rod-like transition upon increasing V in the Al 3 Ni system, with broad implications to a large class of irregular eutectics.

36 MATERIALS SCIENCE↗

Muon detectors, systems and methods

A muon detector system capable of determining muon direction and flight trajectory or path is disclosed. The muon detector system includes scintillators for determining muon direction, and an array of muon detectors arranged in orthogonal layers for determining flight trajectory. The system can be used for tomographic and telescopic mode imaging, and may be used for imaging concealed and/or subterranean objects.

Bonal, Nedra D.↗

Composition and Structure of the EGS Collab Test Bed 1 Based Upon Electrical Resistivity Tomography, Core Compositions, and Wireline Logging

The nature of core from the EGS Collab project was characterized with high resolution XRF analyses on selected core intervals and wireline geophysical logs. Electrical resistivity profiles from the wireline geophysical surveys are consistent with the electrical resistivity tomographic three-dimensional images, and the XRF profiles show elevated levels of sulfur in the vicinity of the interpreted conductivity anomalies. The compositional and wireline logging data are consistent with interpretations from the electrical resistivity tomography data. Based upon these observations the best candidate for the source of the high electrical conductivities is the presence of significant amounts of sulfides within the unit.

Roggenthen, William↗

Recent Advances in Radar Polarimetry and Polarimetric SAR Interferometry

The development of Radar Polarimetry and Radar Interferometry is advancing rapidly, and these novel radar technologies are revamping Synthetic Aperture Radar Imaging decisively. In this exposition the successive advancements are sketched; beginning with the fundamental formulations and high-lighting the salient points of these diverse remote sensing techniques. Whereas with radar polarimetry the textural fine-structure, target-orientation and shape, symmetries and material constituents can be recovered with considerable improvements above that of standard amplitude-only Polarization Radar ; with radar interferometry the spatial (in depth) structure can be explored. In Polarimetric-Interferometric Synthetic Aperture Radar (POL-IN-SAR) Imaging it is possible to recover such co-registered textural plus spatial properties simultaneously. This includes the extraction of Digital Elevation Maps (DEM) from either fully Polarimetric (scattering matrix) or Interferometric (dual antenna) SAR image data takes with the additional benefit of obtaining co-registered three-dimensional POL-IN-DEM information. Extra-Wide-Band POL-IN-SAR Imaging - when applied to Repeat-Pass Image Overlay Interferometry - provides differential background validation and measurement, stress assessment, and environmental stress-change monitoring capabilities with hitherto unattained accuracy, which are essential tools for improved global biomass estimation. More recently, by applying multiple parallel repeat-pass EWB-POL-D(RP)-IN-SAR imaging along stacked (altitudinal) or displaced (horizontal) flight-lines will result in Tomographic (Multi- Interferometric) Polarimetric SAR Stereo-Imaging , including foliage and ground penetrating capabilities. It is shown that the accelerated advancement of these modern EWB-POL-D(RP)-IN-SAR imaging techniques is of direct relevance and of paramount priority to wide-area dynamic homeland security surveillance and local-to-global environmental ground-truth measurement and validation, stress assessment, and stress-change monitoring of the terrestrial and planetary covers. In addition, various closely related topics of (i) acquiring additional and protecting existing spectral windows of the Natural Electromagnetic Spectrum (NES) pertinent to Remote Sensing; (ii) mitigating against common "Radio Frequency Interference (RFI)" and intentional Directive Jamming of Airborne & Space borne POL-IN-SAR Imaging Platforms are appraised.

Boerner, Wolfgang-Martin↗

A hybrid machine-learning approach for analysis of methane hydrate formation dynamics in porous media with synchrotron CT imaging

Fast multi-phase processes in methane hydrate bearing samples pose a challenge for quantitative micro-computed tomography study and experiment steering due to complex tomographic data analysis involving time-consuming segmentation procedures. This is because of the sample's multi-scale structure, which changes over time, low contrast between solid and fluid materials, and the large amount of data acquired during dynamic processes. Here, a hybrid approach is proposed for the automatic segmentation of tomographic data from time-resolved imaging of methane gas-hydrate formation in sandy granular media, which includes a deep-learning 3D U-Net model. To prepare a training dataset for the 3D U-Net, a technique to automate data labeling based on sample-specific information about the mineral matrix immobility and occasional fluid movement in pores is proposed. Automatic segmentation allowed for studying properties of the hydrate growth in pores, as well as dynamic processes such as incremental flow and redistribution of pore brine. Results of the quantitative analysis showed that for typical gas-hydrate stability parameters (100 bar methane pressure, 7°C temperature) the rate of formation is slow (less than 1% per hour), after which the surface area of contact between brine and gas increases, resulting in faster formation (2.5% per hour). Hydrate growth reaches the saturation point after 11 h of the experiment. Finally, the efficacy of the proposed segmentation scheme in on-the-fly automatic data analysis and experiment steering with zooming to regions of interest is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Experimental distinction of the molecularly induced Balmer emission contribution and its application for inferring molecular divertor density with 2D filtered camera measurements during detachment in JET L-mode plasmas

A previously presented model for generating 2D estimates of the divertor plasma conditions at JET from deuterium Balmer line intensity ratios, obtained from tomographic reconstructions of divertor camera images, was amended to consider also the Balmer emission arising from molecular processes. Utilizing the AMJUEL and H2VIBR atomic and molecular databases of EIRENE enabled also inference of the molecular divertor density from the distinguished molecularly induced emission. Analysis of a JET L-mode density scan suggests the molecularly induced emission accounting for up to 60%–70% and 10%–20% of the Balmer Dα and Dγ intensities, respectively, at the onset of detachment, while electron-ion recombination becomes increasingly dominant with deepening detachment. Similar observations were made by post-processing EDGE2D-EIRENE simulations, which indicated significant roles of molecular D$^{+}_{2}$ ions and vibrational excitation of the D 2 molecules as precursors for the molecularly induced emission. The experimentally inferred molecular density at the outer strike point was found to increase monotonously with decreasing strike point temperature, reaching approximately 30%–50% of the local electron density at n mol, osp = 1–2 X 10 20 m -3 at T e,osp ≈ 0.7 eV. A further steep increase by a factor of 3–5 was observed with decrease of T e,osp to 0.5 eV. The observations are in qualitative and reasonable quantitative agreement with EDGE2D-EIRENE predictions of n mol, osp within the uncertainties of the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Challenges in solving structures from radiation-damaged tomograms of protein nanocrystals assessed by simulation

Structure-determination methods are needed to resolve the atomic details that underlie protein function. X-ray crystallography has provided most of our knowledge of protein structure, but is constrained by the need for large, well ordered crystals and the loss of phase information. The rapidly developing methods of serial femtosecond crystallography, micro-electron diffraction and single-particle reconstruction circumvent the first of these limitations by enabling data collection from nanocrystals or purified proteins. However, the first two methods also suffer from the phase problem, while many proteins fall below the molecular-weight threshold required for single-particle reconstruction. Cryo-electron tomography of protein nanocrystals has the potential to overcome these obstacles of mainstream structure-determination methods. Here, a data-processing scheme is presented that combines routines from X-ray crystallography and new algorithms that have been developed to solve structures from tomograms of nanocrystals. This pipeline handles image-processing challenges specific to tomographic sampling of periodic specimens and is validated using simulated crystals. The tolerance of this workflow to the effects of radiation damage is also assessed. The simulations indicate a trade-off between a wider tilt range to facilitate merging data from multiple tomograms and a smaller tilt increment to improve phase accuracy. Since phase errors, but not merging errors, can be overcome with additional data sets, these results recommend distributing the dose over a wide angular range rather than using a finer sampling interval to solve the protein structure.

59 BASIC BIOLOGICAL SCIENCES↗

Seeing the whole picture: Methods for getting the most from micro X-ray computed tomography of TRISO nuclear fuel particles

Tristructural isotropic (TRISO) coated fuel particles are a nuclear fuel form under extensive study for use in advanced nuclear reactor concepts. TRISO fuels are subjected to high temperature neutron irradiations and then examined to assess their performance by determining fission product retention and studying morphological changes. Micro X-ray computed tomography is one method of nondestructively studying the effects of TRISO performance. This work addresses the need for image processing to remove X-ray tomographic reconstruction artifacts that prevent the study of TRISO features, as the TRISO particles’ high Z kernel can introduce metal artifacts that degrade the image quality in the surrounding low Z coating layers. These metal artifacts were reduced by imaging the TRISO particles with both high- and low-energy X-rays and applying a mask to the radiographs obtained with low-energy X-rays to digitally remove the dense fuel kernel region. These masked radiographs were then used to produce a tomographic reconstruction which was combined with the tomographic reconstruction of the high-energy data. This enabled the relatively-low-density TRISO buffer layer to be examined in more detail, providing information on irradiation induced dimensional changes of the coatings. This methodology, which helps see the full picture of a TRISO particle, is not limited to nuclear fuels but can be applied to systems that contain highly attenuating material surrounded by less dense materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility Study: High-k Temperature (HiT) Fluctuation Diagnostic

The objective of the proposed research was to explore the feasibility of making measurements of high-k (electron-scale, ETG-relevant) electron temperature fluctuations in the core plasma of tokamaks and stellarators. We found that soft X-ray imaging combined with our novel pseudolocal tomographic algorithm enables local measurements of low-k (ion-scale, ITG/TEM and KBM/MTM relevant) electron temperature fluctuations in spherical tokamaks. The design parameters needed to consider deploying this new diagnostic are presented, and predictions for what the diagnostic would measure in L-mode and H-mode plasmas at NSTX-U, a high performance spherical tokamak in the USA, suggest that the new diagnostic can be used to study turbulence and transport over a wide range of plasma parameters, such as collisionality and plasma beta.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗