Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Measurement of LET distribution and dose equivalent on board the space shuttle STS-65

Space radiation dosimetry measurements have been made on board the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD)" utilizing silicon semi-conductor detectors and others are conventional detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. Using the RRMD detector, the first attempt of real-time monitoring of space radiation has been achieved successfully for a continuous period of 251.3 h, giving the temporal variations of LET distribution, particle count rates, and rates of absorbed dose and dose equivalent. The RRMD results indicate that a clear enhancement of the number of trapped particles is seen at the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent, while some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions for galactic cosmic ray particles (GCRs). Therefore, the main contribution to dose equivalent is seen to be due to GCRs in this low altitude mission (300 km). Also, the dose equivalent rates obtained by TLDs and CR-39 ranged from 146.9 to 165.2 microSv/day and the average quality factors from 1.45 to 1.57 depending on the locations and directions of detectors inside the Space-lab at this highly protected orbit for space radiation with a small inclination (28.5 degrees) and a low altitude (300 km). The LET distributions obtained by two different detectors, RRMD and CR-39, are in good agreement in the region of 15-200 keV/mm and difference of these distributions in the regions of LET < 15 keV/mm and LET > 200 keV/mm can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks.

manned↗

A simple way to measure daily lifestyle regularity

A brief diary instrument to quantify daily lifestyle regularity (SRM-5) is developed and compared with a much longer version of the instrument (SRM-17) described and used previously. Three studies are described. In Study 1, SRM-17 scores (2 weeks) were collected from a total of 293 healthy control subjects (both genders) aged between 19 and 92 years. Five items (1) Get out of bed, (2) First contact with another person, (3) Start work, housework or volunteer activities, (4) Have dinner, and (5) Go to bed were then selected from the 17 items and SRM-5 scores calculated as if these five items were the only ones collected. Comparisons were made with SRM-17 scores from the same subject-weeks, looking at correlations between the two SRM measures, and the effects of age and gender on lifestyle regularity as measured by the two instruments. In Study 2 this process was repeated in a group of 27 subjects who were in remission from unipolar depression after treatment with psychotherapy and who completed SRM-17 for at least 20 successive weeks. SRM-5 and SRM-17 scores were then correlated within an individual using time as the random variable, allowing an indication of how successful SRM-5 was in tracking changes in lifestyle regularity (within an individual) over time. In Study 3 an SRM-5 diary instrument was administered to 101 healthy control subjects (both genders, aged 20-59 years) for two successive weeks to obtain normative measures and to test for correlations with age and morningness. Measures of lifestyle regularity from SRM-5 correlated quite well (about 0.8) with those from SRM-17 both between subjects, and within-subjects over time. As a detector of irregularity as defined by SRM-17, the SRM-5 instrument showed acceptable values of kappa (0.69), sensitivity (74%) and specificity (95%). There were, however, differences in mean level, with SRM-5 scores being about 0.9 units [about one standard deviation (SD)] above SRM-17 scores from the same subject-weeks. SRM-5 scores also deviated more from a Gaussian distribution than did SRM-17 ones. In a study with a sample size of 101, the new SRM-5 instrument yielded scores with a mean of 4.11 and an SD of 1.13. Correlations between lifestyle regularity and age, and between lifestyle regularity and morningness appeared similar whether 5-item or 17-item SRM measures were used. When a gender difference in lifestyle regularity appeared, it was detected by both SRM-5 and SRM-17 measures.

Non-NASA Center↗

Modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz

A sounding rocket-borne electron detector of high time resolution is used to search for modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz and energy range 5-7 keV. Data were telemetered to ground via a 93-kHz subcarrier. A cross-correlation analysis of the data collected indicates low-level modulation near the detection threshold of the instrument. Two U-1 events are observed which are interpreted as indications of modulation. The two modulation events occur during a period of increasing flux for a region marking the boundary between two current sheets detected by the payload magnetometer. The strongest argument against interference contamination is the lack of any observable modulation at times other than those mentioned in the study.

Spiger, R. J.↗

Chopper-stabilized phase detector

Phase-detector circuit for binary-tracking loops and other binary-data acquisition systems minimizes effects of drift, gain imbalance, and voltage offset in detector circuitry. Input signal passes simultaneously through two channels where it is mixed with early and late codes that are alternately switched between channels. Code switching is synchronized with polarity switching of detector output of each channel so that each channel uses each detector for half time. Net result is that dc offset errors are canceled, and effect of gain imbalance is simply change in sensitivity.

Hopkins, P. M.↗

Reanalysis of the Apollo cosmic gamma-ray spectrum in the 0.3 to 10 MeV energy region

Additional data obtained from the Apollo 16 and 17 missions, together with collateral calculations on background radiation effects, have made possible an improved subtraction of unwanted backgrounds from the diffuse cosmic gamma ray data previously reported from Apollo 15. As a result, the 1 to 10 MeV spectrum is lowered significantly and connects smoothly with recent data at other energies. The inflection reported previously is much less pronounced and has no more than 1.5 sigma significance. Sky occultation by the Apollo 16 spacecraft shows the bulk of the 0.3 to 1 MeV radiation to be diffuse. The analysis of spurious backgrounds points to important improvements for future experiments designed for this spectral region. A light-weight satellite design can give a fourfold improvement in the signal to noise for such a measurement. Use of an anisotropic central crystal, which spins quickly compared with possible time variations in detector background, would enable sensitive limits to be set on galactic plane and point source contributions.

Dyer, C. S.↗

Jet transport performance in thunderstorm wind shear conditions

Several hours of three dimensional wind data were collected in the thunderstorm approach-to-landing environment, using an instrumented Queen Air airplane. These data were used as input to a numerical simulation of aircraft response, concentrating on fixed-stick assumptions, while the aircraft simulated an instrument landing systems approach. Output included airspeed, vertical displacement, pitch angle, and a special approach deterioration parameter. Theory and the results of approximately 1000 simulations indicated that about 20 percent of the cases contained serious wind shear conditions capable of causing a critical deterioration of the approach. In particular, the presence of high energy at the airplane's phugoid frequency was found to have a deleterious effect on approach quality. Oscillations of the horizontal wind at the phugoid frequency were found to have a more serious effect than vertical wind. A simulation of Eastern flight 66, which crashed at JFK in 1975, served to illustrate the points of the research. A concept of a real-time wind shear detector was outlined utilizing these results.

Mccarthy, J.↗

X-ray position detector

An X-ray position detector for real time operation is described. A set of proportional counters is arranged into an array which can detect and indicate the position of an X-ray interaction within the array, in the X Y plane.

Garmire, G.↗

Upstream particles observed in the earth's foreshock region

The characteristics and interrelationships of upstream suprathermal particles and plasma waves observed in the earth's foreshock region are examined on the basis of data from eight instruments, including the University of Iowa Lepedeas, and plasma wave instruments, the Berkeley high time resolution particle detectors, and the UCLA magnetometer on ISEE 1 and 2. It is found that suprathermal ions in the foreshock region travel along the magnetic field away from the bow shock. It is also found that ions observed in the foreshock region display gyrophase organization produced by ion clusters with a spatial scale of less than 1 Rg, and that dispersed ion distributions are produced primarily by direct sources at or near the bow shock.

Eastman, T. E.↗

Astrophysical applications of high angular resolution array-telescopes

The air shower array-telescopes which are currently being used to search for and study point sources of UHE gamma-rays have angular resolution similar to 1 deg, limited by either the small total area of particle detectors or poor timing resolution. As the signal to noise ratio depends sensitively on the angular resolution, it seems certain that this figure will quickly be surpassed when second generation instruments come into operation. Since the trajectories of galactic cosmic rays with E 100,000 GeV are practically straight lines on scales of 1 A.U. or less, these new instruments will be able to observe a shadow cast by the Moon (angular diameter 0.5 deg). Although the angular diameter of the Sun is practically the same, its shadow will be more complex because of its magnetic field. Thus, high angular resolution observations of the Sun afford a means of investigating the solar magnetic field, and also the charge composition of cosmic rays, including the ratio of antiprotons to protons.

Linsley, J.↗

High intensity 5 eV atomic oxygen source and Low Earth Orbit (LEO) simulation facility

An atomic oxygen exposure facility has been developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in LEO. The studies that are being undertaken using the facility will provide: absolute reaction cross sections for use in engineering design problems; formulations of reaction mechanisms; and calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in LEO to ground based investigations. The facility consists of: (1) a CW laser sustained discharge source of O atoms having a variable energy up to 5 eV and an intensity between 10(15) and 10(17) O atoms s(-1) cm(-2); (2) an atomic beam formation and diagnostics system consisting of various stages of differential pumping, a mass spectrometer detector, and a time of flight analyzer; (3) a spinning rotor viscometer for absolute O atom flux measurements; and (4) provision for using the system for calibration of actual flight instruments. Surface analysis equipment is available for the characterization of material surfaces before and after exposure to O atoms.

Cross, J. B.↗

Optical investigation of Comet Halley

The physical properties of Comet P/Halley are being monitored from the ground using state of the art optical detectors. The long time base (1982-present) of the observations provides a unique record of the development of activity in a single comet. In addition, physical properties of other comets are measured to provide a reference against which Comet Halley may be compared. Results for the past year include: (1) publication of the first results on the surface brightness profiles of dust comets; (2) charge coupled device measurements of Comet Bowell show that the activity of comets can persist at least to heliocentric distances R = 13.6 AU; (3) a study of the back-scattering phase angle dependences of 5 comets (including Halley) shows evidence for small linear phase coefficients in each case; (4) temporal monitoring of P/Halley continues.

Jewitt, David↗

IRAS observations of extended dust envelopes around evolved stars

Deconvolved IRAS profiles, with resolution 2-3 time better than detector sizes 1.5 and 3 arcmin at 60 and 100 microns, are presented for a number of evolved stars with extended emission. These include VY UMa, Mu Cep, S Sct, U Hya, Y CVn, U Ant, alpha Ori, Y Pav, UU aur, IRC + 10216, RZ Sgr, and R Lyr. Simple models suggest that extended IRAS emission results from stars which greater mass loss rates in the past, rather than from stars with large current mass loss rates.

Hawkins, George↗

The Mars Observer laser altimeter investigation

The primary objective of the Mars Observer laser altimeter (MOLA) investigation is to determine globally the topography of Mars at a level suitable for addressing problems in geology and geophysics. Secondary objectives are to characterize the 1064-nm wavelength surface reflectivity of Mars to contribute to analyses of global surface mineralogy and seasonal albedo changes, to assist in addressing problems in atmospheric circulation, and to provide geodetic control and topographic context for the assessment of possible future Mars landing sites. The principal components of MOLA are a diode-pumped, neodymium-doped yttrium aluminum garnet laser transmitter that emits 1064-nm wavelength laser pulses, a 0.5-m-diameter telescope, a silicon avalanche photodiode detector, and a time interval unit with 10-ns resolution. MOLA will provide measurements of the topography of Mars within approximately 160-m footprints and a center-to-center along-track foot print spacing of 300 m along the Mars Observer subspacecraft ground track. The elevation measurements will be quantized with 1.5 m vertical resolution before correction for orbit- and pointing induced errors. MOLA profiles will be assembled into a global 0.2 deg x 0.2 deg grid that will be referenced to Mars' center of mass with an absolute accuracy of approximately 30 m. Other data products will include a global grid of topographic gradients, corrected individual profiles, and a global 0.2 deg x 0.2 deg grid of 1064-nm surface reflectivity.

Zuber, M. T.↗

Numerical Filtering of Spurious Transients in a Satellite Scanning Radiometer: Application to CERES

The Clouds and Earth Radiant Energy System (CERES) scanning, radiometer was designed to provide high accuracy measurements of the radiances from the earth. Calibration testing of the instruments showed the presence of all undesired slow transient in the measurements of all channels at 1% to 2% of the signal. Analysis of the data showed that the transient consists of a single linear mode. The characteristic time of this mode is 0.3 to 0.4 s and is much greater than that the 8-10-ms response time of the detector, so that it is well separated from the detector response. A numerical filter was designed for the removal of this transient from the measurements. Results show no trace remaining of the transient after application of the numerical filter. The characterization of the slow mode on the basis of ground calibration data is discussed and flight results are shown for the CERES instruments aboard the Tropical Rainfall Measurement Mission and Terra spacecraft. The primary influence of the slow mode is in the calibration of the instrument and the in-flight validation of the calibration. This method may be applicable to other radiometers that are striving for high accuracy and encounter a slow spurious mode regardless of the underlying physics.

Smith, G. Louis↗

SILVER: Surface Imaging for Lunar Volatiles, Resources, and Exploration

The Surface Imaging for Lunar Volatiles, Exploration, and Resources (SILVER) instrument is a proposed imaging investigation for the 2008 Lunar Reconnaissance Orbiter (LRO) mission. SILVER and its experienced Measurement Team will prepare for and support future lunar human exploration activities, especially landing site identification and certification on the basis of potential resources. SILVER combines a high-resolution pushbroom visible imaging channel (SILVER-HR) and a wide-field-of-view (45 deg) framing imaging channel (SILVER-WF). SILVER-HR will obtain a single-detector 6 km imaging swath of 12,228 pixels at 0.5 m/pixel to image greater than 100 sq km target areas from 50 km altitude, imaging greater than 15% the lunar surface during a 1 year nominal mission. SILVER-HR has excellent stray-light rejection and its imaging detector has selectable time delay integration (TDI) with up to 128 stages for extreme low-light sensitivity, permitting direct imaging of permanently shadowed polar regions in scattered sunlight or earthshine. SILVER-WF will obtain geodetic framing images in a 2048 x 2048 format at 20m/pixel, with 60% along-track overlap stereo for imaging context and for derivation of a global digital elevation model of meter-scale lunar topography.

Pappalardo, R. T.↗

ISS Destiny Laboratory Smoke Detection Model

Smoke transport and detection were modeled numerically in the ISS Destiny module using the NIST, Fire Dynamics Simulator code. The airflows in Destiny were modeled using the existing flow conditions and the module geometry included obstructions that simulate the currently installed hardware on orbit. The smoke source was modeled as a 0.152 by 0.152 m region that emitted smoke particulate ranging from 1.46 to 8.47 mg/s. In the module domain, the smoke source was placed in the center of each Destiny rack location and the model was run to determine the time required for the two smoke detectors to alarm. Overall the detection times were dominated by the circumferential flow, the axial flow from the intermodule ventilation and the smoke source strength.

Brooker, John E.↗

A Deeper Look at the Fundamentals of Heterodyne Detection Requirements

We generally accept the experimentally observed criteria for heterodyne detections that the two waves that are mixed must (i) be collinear, (ii) have matched wave fronts and (iii) cannot be orthogonally polarized. We have not found in the literature adequate physical explanations for these requirements. The purpose of this paper is to find deeper physical understanding of the coherent heterodyne detection processes that could lead to better coherent laser radar system designs1. We find that there are a number of unresolved paradoxes in classical and quantum optics regarding the definitions and understanding of the "interference" and "coherence" properties of light, which are attributed as essentially due to inherent properties of the EM waves. A deeper exploration indicates that it is the various quantum mechanical properties of the detecting material dipoles that make light detectable (visible, or measurable) to us. Accordingly, all the properties that we generally attribute to only light, are in reality manifestations of collective properties of dipole-light interactions. "Interference" and "coherence" can be better understood in terms of this mutual interaction, followed by energy absorption by the dipoles from EM wave fields, manifesting in some measurable transformation of the detecting dipoles. Light beams do not interfere by themselves. The superposition effects due to light beams become manifest through the response characteristics of the detecting dipoles. In this paper, we will show some preliminary expe rimental results that clearly demonstrate that the heterodyning wave fronts have quantitative degradation in signal generation as the angle between them deviates from perfect collinearity. Subsequently, we will propose a hypothesis for this behavior. We will present experimental data establishing that the so called incoherent light can be detected through heterodyne mixing as long as the pulse length contained in the "incoherent" light is longer than the response time of the detector. We will also present a correspondingly better interpretation of two distinguishable coherence properties, temporal coherence and spectral coherence. Our investigation provides a deeper insight into how to rela x various system requirements for heterodyne detection and accordingly develop systems that are simpler, more reliable and lower in cost. Also, we believe that engineering of detector architecture by appropriately modifying dipole behavior using emerging nanotechnology to optimize heterodyne efficiency will be advantageous.

Roychoudhuri, Chandrasekhar↗