System code evaluation of near-term accident tolerant claddings during pressurized water reactor station blackout accidents

Following the Fukushima Daiichi nuclear accident in 2011, researches on Accident-tolerant fuels (ATFs) are currently of high interest in not only the nuclear industry but also governmental and international organizations. In this work, a quantitative evaluation of the performance of monolithic FeCrAl cladding and Cr-coated Zircaloy cladding has been performed for Pressurized Water Reactor (PWR) Station Blackout (SBO) accidents. A generic PWR model has been built in system thermal-hydraulics code TRACE based on the Surry Nuclear Power Station with counter-current natural circulation modelling capability for hotleg and steam generator U-tube components during the accidents. The base model results are then compared to MELCOR and RELAP simulations to verify the system component implementation in TRACE. Two PWR SBO scenarios were investigated, including: short-term SBO and long-term SBO with early reactor coolant pump (RCP) seal failure. These scenarios are defined to be very similar to the accidents studied in the State-of-the-Art Reactor Consequence Analysis (SOARCA) project. TRACE code is modified to reflect the oxidation kinetics of FeCrAl and Cr-coating. Larson-Miller creep rupture model is also implemented in TARCE using its built-in control systems to simulate the creep rupture of hotlegs. Additionally, the comparison between the TRACE models with and without the counter-current flow modeling resulted in significant difference when comparing ATF cladding to Zircaloy for short term SBO, while it marginal impacted the performance during long term SBO with RCP seal failure. For short term SBO, both ATF cladding underwent hot leg creep rupture ~20 min after Zircaloy cladding. While Zircaloy and Cr-coated cladding had generated significant amount of hydrogen gas (>10 kg) before the creep rupture event, FeCrAl cladding had only generated <0.5 kg of hydrogen gas. For long term SBO with RCP seal failure, significant hydrogen generation and fuel melting was predicted before hot leg creep rupture for the ATF cladding while providing only 10–20 min additional coping time compared to Zircaloy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release on the Virtual Test Bed of a Molten Salt Reactor Experiment SAM-Pronghorn Coupled Model using the Domain Overlapping Approach

The nuclear industry is taking leaps in innovations with companies seeking a sustainable energy future through advanced nuclear reactors. The Department of Energy (DOE)’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program seeks to substantiate and bolster the deployment of advanced reactors through flexible multifidelity, multiphysics simulations of advanced nuclear reactors. Applications like SAM for one-dimensional systems thermalhydraulics, and Pronghorn for multidimensional coarse mesh thermal-hydraulics, are geared to support innovations in industry by facilitating design, optimization, and licensing of advanced nuclear reactors. Coupling systems thermal-hydraulics and computational fluid dynamics codes can be difficult as the pressure coupling converges slowly; however, it is important to obtain the desired accuracy in each part of the primary loop. The authors of this model created an Overlapping-Domain Coupling (ODC) approach to coupling SAM and Pronghorn. Leveraging this coupling technique, a Molten Salt Reactor Experiment (MSRE) model was developed and released to the NEAMS/National Reactor Innovation Center (NRIC) Virtual Test Bed (VTB). The MSRE was chosen to be modeled because of the wealth of experimental data available and because of the strong physics coupling between the core and primary circuit. This paper contextualizes the history of the MSRE, describes the thermal hydraulics models used, and detail the implementation of multidimensional thermal-hydraulics and system codes based on the ODC method for the MSRE model. Finally, this paper presents how other modelers could apply the SAM Pronghorn ODC for other advanced reactor models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status Report on Thermal Extraction Modeling within HYBRID

Idaho National Laboratory continues to be at the forefront of advanced reactor systems and integrated energy systems (IES) research. The HYBRID modeling repository is the computational modeling repository used to evaluate potential IES configurations. To support IES analysis, it is necessary to develop models that can evaluate a range of thermal integration points within given energy conversion systems. This work includes as many technologies as possible anticipating that many technologies will be deployed to broadly reduce climate impacts of energy intensive processes. To provide this analysis, a new balance of plant model has been generated. This report will discuss progress on this new main model and discuss nominal conditions for the primary reactor types contained within HYBRID.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using Models to Predict the Hygrothermal Performance of Equipment and Piping Insulation

The development of hygrothermal models began in earnest in the 1990s, with the initial emphasis on the performance of building envelope systems. Numerous large-scale building envelope failures associated with water intrusion drove this development. The physical principles of moisture transfer that apply to building envelopes are equally valid for equipment and piping insulation systems. The main advantage of modeling is that carefully characterized models can predict the long-term hygrothermal performance of any system under different climatic and interior conditions. Thermal insulations are commonly used on outdoor equipment and piping for different applications, such as thermal energy conservation and freeze protection. The insulated equipment usually experiences moisture intrusion due to many factors, such as the duration and frequency of moisture exposure, equipment operating temperature, insulation type, exposure temperature, weather conditions, equipment thermal cycling, and weatherproofing condition. Hygrothermal models have been employed to estimate the moisture pickup of insulated equipment and piping systems, as well as the moisture redistribution and subsequent change in thermal performance as these systems become contaminated with moisture. The hygrothermal model provides insights on the parameters influencing the time of wetness, the lateral redistribution of moisture along the pipe away from the leak, and the ease by which water escapes the insulation/jacketing systems. It has been shown that the moisture leak effect decreases rapidly with distance from the leak and that one- and two-dimensional hygrothermal simulations help to identify solutions to reduce conditions that support corrosion under insulation (CUI).

Shrestha, Som↗

Electric-Drive Vehicle Power Electronics Thermal Management: Current Status, Challenges, and Future Directions

Effective thermal management of traction-drive power electronics is critical to the advancement of electric-drive vehicles and is necessary for increasing power density and improving reliability. Replacing traditional silicon devices with more efficient, higher temperature, higher voltage, and higher frequency wide-bandgap (WBG) devices will enable increased power density but will result in higher device heat fluxes. Compact packaging of high-temperature WBG devices near low-temperature-rated components creates thermal management challenges that need to be addressed for future power-dense systems. This paper summarizes the thermal performance of on-road automotive power electronics thermal management systems and provides thermal performance and pumping-power metrics for select vehicles. Thermal analyses reveal that the package/conduction resistance dominates the total thermal resistance (for existing automotive systems). We model advanced packaging concepts and compare the results with existing packaging designs to quantify their thermal performance enhancements. Double-side-cooled configurations that do not use thermal interface materials are package concepts predicted to provide a low junction-to-fluid thermal resistance (compared to current packages). Dielectric-fluid-cooled concepts enable a redesign of the package to reduce the package resistance, can be implemented in single- and two-phase cooling approaches, and allow for cooling of passive components (e.g., capacitors) and bus bars.

33 ADVANCED PROPULSION SYSTEMS↗

High temporal resolution generation expansion planning for the clean energy transition

As power systems integrate increasing quantities of wind, solar and energy storage resources, it is important to revisit power system capacity expansion modeling methods and assumptions that have been utilized in thermal- dominated systems. We conduct a series of case study analyses using a simplified representation of the Electric Reliability Council of Texas (ERCOT) system to demonstrate how least-cost capacity expansion outcomes are impacted by changes in model resolution across two temporal dimensions: 1) the number of considered representative periods, and 2) the system dispatch interval. First, we find that the least-cost generation portfolio can differ significantly for small changes in the number of representative days, but largely converges to the 365-day result once 104 representative days are considered. Furthermore, systems with wind, solar and storage resources were more sensitive to changes in the number of representative days than a thermal-dominated system. Second, we find that considering five-minute dispatch resolution consistently results in least-cost generation portfolios with less solar capacity and more energy storage capacity than corresponding scenarios with hourly dispatch intervals. This suggests that hourly dispatch representation fails to capture the intra-hour volatility of solar generation, and therefore also overlooks opportunities for storage resources to provide system value by balancing this volatility. Collectively these results indicate that capacity expansion modelers should revisit conventional approaches to temporal representation when conducting analyses of deeply decarbonized power systems to ensure that such analyses are robust and actionable. To our knowledge, this is the first study to analyze capacity expansion outcomes with five-minute dispatch resolution in this manner.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of low-exergy heating and cooling systems and topology optimization for deep energy savings at the urban district level

District energy systems have the potential to achieve deep energy savings by leveraging the density and diversity of loads in urban districts. However, planning and adoption of district thermal energy systems is hindered by the analytical burden and high infrastructure costs. It is hypothesized that network topology optimization would enable wider adoption of advanced (ambient temperature) district thermal energy systems, resulting in energy savings. In this study, energy modeling is used to compare the energy performance of “conventional” and “advanced” district thermal energy systems at the urban district level, and a partial exhaustive search is used to evaluate a heuristic for the topology optimization problem. For the prototypical district considered, advanced district thermal energy systems mated with low-exergy building heating and cooling systems achieved a source energy use intensity that was 49% lower than that of conventional systems. The minimal spanning tree heuristic was demonstrated to be effective for the network topology optimization problem in the context of a prototypical district, and contributes to mitigating the problem’s computational complexity. The work presented in this paper demonstrates the potential of advanced district thermal energy systems to achieve deep energy savings, and advances to addressing barriers to their adoption through topology optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Response of a Lithium Vapor Divertor to Cyclical Operation

The lithium vapor divertor concept is being developed as a method to achieve detached divertor conditions in a tokamak while minimizing impurity radiation losses from the core plasma. SOLPS-ITER modeling has previously been used to identify some of the geometric constraints and required lithium evaporation rate of a lithium vapor divertor in a medium-sized tokamak during steady-state operation. Here an updated conceptual design based on these operating requirements is introduced and the thermal response of the system is modeled during cyclical operation, consistent with operation in a short-pulse tokamak. Controllability of the temperature of the lithium capillary porous system (CPS) is achieved by adopting a design where there is no line-of-sight for radiation from the plasma to reach the heated CPS surface. Operational strategies to minimize the amount of lithium evaporated between plasma discharges while achieving steady evaporation rates during plasma discharges are discussed and modeled here. The optimal feedforward control strategy demonstrated in this work is to ramp up the temperature of the evaporator as quickly as possible immediately before a plasma discharge and then reduce the heating to match the desired steady-state net evaporation rate just before the plasma discharge begins, allowing the thermal inertia of the system to stabilize the evaporation rate during the first second of the plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation and Verification of TEDS Facility HYBRID Modeling

The HYBRID modeling repository is an in-house developed library of models for selected integrated energy systems (IES) modelling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Here, validation and verification (V&V) capabilities are demonstrated using the Thermal Energy Distribution System (TEDS) at INL. Building upon prior work, the TEDS model has been updated and verified so that it better represents the installed system configuration and the operating control system. The model control system was changed to allow replication of actual experimental procedures. Experimental operations focusing primarily on thermocline tank performance were devised and performed. Several anomalies were found in the operation data of the experiment facility. V&V activities calibrating a selected input parameter are demonstrated on a single component as well as with a single parameter within the thermocline. Calibrating is then demonstrated on multiple components and a multi-parameter metric for the entire system. The validation methodology is successfully applied to validate the model with experimental data. It is also used to confirm a hypothesis behind one of the anomalies in experimental performance.

25 ENERGY STORAGE↗

Uncertainty Quantification and Sensitivity Analysis of Non-Nuclear Advanced Controls Testbed Reactor Mockup

The research presented in this report describes our progress in applying stochastic methods and uncertainty quantification, parametric study, and variance-based sensitivity analysis (also known as Sobol sensitivity analysis) to a full-core model of a nuclear thermal propulsion (NTP) system simulated with Griffin, with the goal of developing a reduced order (surrogate) model which can be rapidly sampled while perturbing multiple input parameters. In this NTP system, reactivity and power feedback affect the rotation of control drums, which are controlled by a hybrid proportional, integral and derivative (PID) controller, actuated by the power demand and reactivity feedback from the numerical model. This model uses reactor kinetic feedback (mean generation time and $\beta$ from a transient Griffin simulation executed with the improved quasi-static method to provide the kinetic parameters) as inputs to functions which control the CD rotation angle. Using a number of stochastic method approaches, we developed a dual purpose training-surrogate model of the NTP system using polynomial regression. The trained model can be rapidly sampled while simultaneously perturbing various input parameters of the model, such as coefficients on the PID control, or temperature (directly affect the neutron cross section). The surrogate model delivers accurate results orders-of-magnitude faster (minutes, not days) than the base model. Once the base model has been trained, distributions of the uncertain parameters can be changed at will to investigate the effects of perturbing multiple inputs and their effect on the output. For example, coefficients used in the PID control system may vary due to some physical interference, or there may be uncertainty in the temperature of the neutron cross sections in various regions of the reactor. A distribution can be placed on these parameters and operational boundaries can be determined. The goal of this work is to support development of an advanced control system to operate CDs in a functioning NTP system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Species Transport Framework Development in SAM for System-Level Tritium Source Term Analysis

The SAM code is under development as a modern system-level modeling and simulation tool for advanced non–light water reactor safety analyses, with recent efforts to add capabilities to evaluate radiological source term risks in these novel reactor concepts. By leveraging the established system-level multiphysics thermal-hydraulic models in SAM, a framework for tightly coupled species transport modeling has been integrated into the code for engineering-scale source term evaluation. This species transport framework was first applied to the simulation of tritium, which is a well-known source term in conventional light water reactors. Tritium poses a unique risk in salt-cooled reactors, especially those with lithium-bearing salts such as the fluoride salt–cooled high-temperature reactor (FHR) concept, as tritium is generated in the salt coolant in significant quantities due to neutron interactions. A compounding factor is the increased mobility of tritium at high temperatures, which is able to permeate through metals while also potentially being retained in graphite pebbles and structures. Engineering-scale models for the tritium transport pathways in a FHR have been developed using the new species transport framework in SAM. The capabilities are assessed through analytical verification problems and validated with data from a graphite retention experiment. In conclusion, the system-level model is demonstrated by performing an initial estimate of baseline tritium generation and flows in a generic reference SAM FHR model, setting a foundation for future studies of source term transient analysis with the potential for further multiscale and multiphysics integration.

SAM↗

Implementation of a Drift Flux Model into SAM with Development of a Verification and Validation Test Suite for Modeling of Noncondensable Gas Mixtures

The advanced thermal-hydraulic system code, System Analysis Module (SAM), was originally developed for the modeling of single-phase flow in advanced reactors. It has since been expanded to include a four-equation drift flux model for the modeling of two-phase flows containing a noncondensable gas. The model was expanded to support the modeling of molten salt reactor (MSR) designs in which the fuel is directly dissolved in the circulating coolant. These designs have shown that circulating gas bubbles can play an important role in the management of fission products and the operational behavior of the reactor. A drift flux model was implemented to more accurately capture the localized behavior of the void in the core and its impact on the mass transfer of fission products. A thorough assessment of the new model was performed by developing a verification and validation test suite. Verification problems were designed to test all major terms in the new governing equations. The new model converged to the correct solution at the expected order of accuracy for all verification cases. The validation cases included a wide range of flow and void conditions in different pipe geometries. Although higher void experiments show a slight underprediction of void by the drift flux model, experiments that aim to reproduce Molten Salt Reactor Experiment (MSRE) experimental conditions show good agreement with the model. The gas transport model was activated for a SAM model of the MSRE to demonstrate that it can be used in a more complex model. Finally, this gas transport model will be used along with an interfacial area transport equation being implemented in SAM for the prediction of mass transport behavior in MSR conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Model predictive control for optimal dispatch of chillers and thermal energy storage tank in airports

Cost of energy consumption is one of the biggest operational cost for airports, and it is increasing from time to time as airports expand to support growing number of passengers. Various factors affect the energy consumption including efficiency of airport Heating Ventilation and Air conditioning (HVAC) systems, which in turn depends on the efficiency of individual subsystems. Here, in this paper, we present an optimal scheduling method for the central plant system at Dallas Fort Worth airport, involving chillers, pumps, and a thermal energy storage (TES) system. A model predictive control (MPC) problem is formulated to minimize both energy and demand charge costs while satisfying the cooling needs of the airport. The proposed Mixed-Integer Nonlinear Programming (MINLP) formulation includes performance curve based models for chillers and pumps and a simplified state of charge model for TES. The formulation also includes predictions of cooling load and chilled water return temperature. Simulation results for a month in summer show savings around 10% compared to the baseline. Initial recommendations based on insights from simulation results to the manual operation procedures resulted in significant savings. Field test results show a 7% chiller efficiency improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theory of thermal properties of magnetic materials with unknown entropy

Theoretical approaches to study thermal properties of magnetic materials typically require accurate models of magnetic interactions in order to define the entropy. Here we introduce a complementary approach for examining thermal properties in magnetic systems where an accepted model for such interactions does not exist. In place of a specific model for magnetic interactions, the approach integrates measurements of temperature dependent magnetization of the studied material into a first principles computational scheme. The approach calculates system pressure from thermally disordered microstates that properly incorporate vibrational and spin subsystems at each temperature as well as the coupling between these subsystems. We apply the approach to calculate phonon modes and to investigate the anomalously low thermal expansion of the classical Invar alloy, Fe 0.65 Ni 0.35 . Here, the calculated phonon dispersions for Invar are in excellent agreement with measured data. The Invar thermal expansion is shown to remain small between 50 K and room temperature, consistent with the experimentally observed low thermal expansion value in this same temperature range. This anomalously small thermal expansion is directly connected to a small positive contribution from lattice thermal disorder that is nearly canceled by a large negative magnetic disorder contribution. By contrast, calculations for bcc Fe show a much larger thermal expansion, consistent with experiment, which is dominated by a large contribution from lattice thermal disorder that is reduced only slightly by a small negative contribution from that of magnetism. These findings give insights into the unusual nature of magnetism and spin-lattice coupling in Invar and Fe. In addition, they give promising preliminary support to the presented new methodology as a complementary way to investigate thermal properties of magnetic materials. The success achieved on Invar and Fe motivates future testing of the approach on other magnetic materials.

36 MATERIALS SCIENCE↗

GridLAB-D Technical Support Document: Residential Equivalent Thermal Parameter Model

GridLAB-D is a power distribution systems simulation and analysis tool developed by Pacific Northwest National Laboratory. Although GridLAB-D and its underlying residential load model has been used in a variety of power systems analyses, comprehensive documentation of the derivation of the residential house model has not been formally published. The purpose of this technical support document is to serve as a comprehensive resource for the thermal dynamics modeling and house definition implemented in GridLAB-D. It covers model derivation, parameter definitions, and implementation steps in the codebase.